Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Claudinei Rodrigues de Aguiar has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Impact of Ionospheric Scintillations on GNSS Availability and Precise Positioning

    by C. R. Aguiar, J. F. G. Monico, A. O. Moraes

    For many applications where accuracy, availability, and integrity are essential, such as geodetic positioning and civil aviation, Global Navigation Satellite Systems (GNSS) are indispensable. However, GNSS signal dependability is severely hampered by ionospheric disturbances, especially equatorial plasma bubbles (EPBs), particularly in equatorial latitudes. To better understand how ionospheric irregularities impact GNSS signals across several constellations (GPS, GLONASS, Galileo, BeiDou, and Satellite‐Based Augmentation Systems) and frequencies, this study examines ionospheric amplitude scintillation. The objective is to comprehend how these anomalies simultaneously affect GNSS performance in high scintillation activity conditions. The research focuses on the effects of amplitude scintillation during periods of high solar activity by analyzing data from four stations across Brazil. The analysis identified the most critical hours for scintillation events, between 20:00 and 23:59 LST, where up to 13 satellites were simultaneously affected at PRU2, resulting in a notable drop in positioning accuracy. This was further reflected in the degradation of Position Dilution of Precision values, which exceeded 5 in approximately 38% of the cases at Presidente Prudente and São José dos Campos, indicating reduced confidence in positioning accuracy during severe scintillation events. Additionally, the study confirms that lower‐frequency signals (L2, G2, B2) are more susceptible to scintillation than higher‐frequency signals (L1, G1, E1). Despite multi‐constellation capabilities, the simultaneous impact of EPBs on multiple GNSS signals leads to degraded satellite availability and positioning accuracy, especially in regions with high electron density. These findings highlight the need for improved mitigation strategies in multi‐constellation systems to enhance GNSS reliability in equatorial regions.


  • Open Access

    Vigilância da qualidade da água tratada usando o Sistema de Informação Geográfica (SIG) no Município de Belém, Pará, ¨Brasil

    by Fábio Sergio Lima Brito, Karoline da Costa Barros, Claudinei Rodrigues de Aguiar

    A água potável e segura é um direito humano imprescindível para todos os segmentos da sociedade. Nesse sentido, o programa de vigilância da qualidade da água para consumo humano (VIGIAGUA) visa promover a saúde coletiva e preventiva da população de forma que se diminuam os agravos de doenças relacionadas à transmissão hídrica, por intermédio da gestão de riscos referentes ao sistema de abastecimento de água. Nesse contexto, o presente trabalho teve por objetivo espacializar e analisar os dados de qualidade da água tratada do município de Belém, situada na região amazônica do Estado do Pará-Brasil, usando a ferramenta de Sistema de Informação Geográfica (SIG). A metodologia foi dividida em três principais etapas: inicialmente, foram consultados os dados do Sistema de Informação de Vigilância de Qualidade da Água (SISAGUA); posteriormente, foi avaliada as metas de atendimento com a cobertura do sistema de abastecimento de água e verificação do cumprimento ao plano de amostragem exigidos pelo VIGIAGUA. Além disso, foram elaborados mapas temáticos comparando os resultados com os padrões de potabilidade exigidos pela legislação vigente. Os resultados para os parâmetros básicos apontaram que a turbidez estava em conformidade com o valor de 5 uT para águas provenientes de captação de águas superficiais e 1 uT para águas subterrâneas, conforme o requerido pela Portaria de n° 888, de 4 de maio de 2021, do Ministério da Saúde (MS). Por outro lado, as variáveis de cloro residual livre, coliformes totais e Escherichia coli apresentaram desempenho “PÉSSIMO” em virtude da alteração da água distribuída à população. Portanto, esse cenário de vulnerabilidade coloca em risco a saúde da população devido à contaminação física, química e microbiológica da água do sistema de abastecimento público do município de Belém, apontando a necessidade de políticas públicas emergenciais para que o padrão de potabilidade seja atendido.

  • Open Access

    Analysis of The Urbanization Expansion Process After the Implementation of the Federal University of Fronteira Sul Campus in The City of Realeza-PR

    by Fábio Onetta, Josiane Carine Hammes, Emilin Regina Gomes Dobrovolski, Claudinei Rodrigues de Aguiar

    Objective: This study uses remote sensing to map the urban expansion of Realeza-PR with the implementation of the Federal University of Fronteira Sul (UFFS) campus, and changes in land use and occupation. Theoretical Framework: Currently, 54% of the world's population is urban, with a forecast of 68% by 2050. To mitigate the impacts of urbanization, urban planning is increasingly on the agenda. Universities are important drivers of the process of physical growth and economic and social development. Method: Bibliographic sources and maps produced and processed in QGIS software were used to identify land use classes based on images from 2009, 2017 and 2024 from the RapidEye satellite. Results and Discussion: Between 2010 and 2022, there was a population increase of 17.80% in the municipality. The images showed urban expansion directed towards the south of the city, where the UFFS was installed, with, between 2009 and 2017, a reduction of 1.74 km² in forest areas and 5.67 km² in soil areas, and an increase of 1.08 km² of asphalt areas, 0.72 km² of grass and 2.15 km² of buildings. Research Implications: The study reveals the impact of the campus on the urban expansion of Realeza, highlighting the effectiveness of QGIS and satellite images for an accurate diagnosis of land use. Originality/Value: This study evaluates the impact of implementing a higher education institution on the urban development of small and medium-sized municipalities, and in the Brazilian context no similar relevant works were found.

  • Open Access

    Editorial

    by Claudinei Rodrigues de Aguiar

  • Open Access

    Editorial

    by Claudinei Rodrigues de Aguiar

  • Open Access

    Editorial

    by Claudinei Rodrigues de Aguiar

  • Open Access

    Editorial

    by Claudinei Rodrigues de Aguiar

  • Open Access

    Editorial

    by Claudinei Rodrigues de Aguiar

  • Open Access

    Assessment of global and regional ionospheric maps over Brazil using simulated kinematic precise point positioning. 

    by Loram Siqueira, Joao Francisco Galera Monico, Claudinei Rodrigues de Aguiar

    Precise point positioning (PPP) is an available solution for one-frequency receivers if the ionosphere delay is informed during the data processing. Such information may be retrieved from the ionospheric maps, which can have a global or regional coverage. IGS has traditionally being providing them globally, throughout different analyses centers. On the other hand, regional products have been increasingly catching the interest of the scientific community.  Regional Ionosphere Maps (RIM) will use local active GNSS networks with multi-frequency receivers to model and represent the ionospheric delays. Because of the larger amount of information from a specific region, which may lack in the global products, the representation can be better and show improvements for areas where the ionosphere is more active. For the South American area, studies have been conducted using active networks. GIB (Brazilian Ionospheric Grid) was developed in 2010 and computes regional maps using GPS data from the Brazilian Continuous Monitoring Stations (RBMC). More recently (2018) the Meteorología espacial, Atmosfera terrestre, Geodesia, Geodinámica, diseño Instrumental y Astrometría (MAGGIA) made available its regional product covering the same area using GNSS data from Brazil, Uruguay and Argentina. Presently we are verging to the beginning of the next solar cycle and understanding the availability of global and regional products for ionosphere correction, and its level of accuracy will be a crucial information to be hold. In this contribution, an evaluation of four products was performed using kinematic PPP for the day 80 of 2021, of course with a reduced amount of data. The global products (CODE and GFZ) used the IGS network on its construction. A reference station from RBMC, with known coordinates was used as the ground truth to determine the accuracy of each product using a simulated PPP kinematics. with residuals and needed system transformation the accuracy and precision for each product was acquired. Overall results show that the MAGGIA product presents the best accuracy, followed by the GFZ, IGS and GIB. For this analysis it was possible to conclude that two elements play an important role when creating ionosphere maps: not only the regional characterization but also using multi constellation GNSS data will play a key role in the products quality. MAGGIA and GIB, both regional products, obtained the best and the worse results, respectively and the major difference being the use of only one GNSS constellation (GIB) and multiple GNSS constellations (MAGGIA) for its calculation.

  • Open Access

    The GNSS NavAer INCT Project Overview and Main Results

    by João Francisco Galera Monico, Eurico Rodrigues de Paula, Alison de Oliveira Moraes, Emanoel Costa, Milton Hirokazu Shimabukuro, Daniele Barroca Marra Alves, Jonas Rodrigues de Souza, Paulo de Oliveira Camargo, Fabricio dos Santos Prol, Bruno César Vani, et al.