Said Abboudi has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Abdel Illah Nabil Korti
Laboratory of Energy and Thermal Applied (ETAP), Faculty of Technology University of Tlemcen Tlemcen Algeria
5 shared publications Abdeslam Omara
FEMTO-ST, UMR 6174 CNRS, CREST Department , University of Technology of Belfort-Montbéliard (UTBM) , Site de Sévenans, Belfort Cedex, France
2 shared publications- Hamidou Benzenine
Smart Structures Laboratory, Faculty of Science and Technology, University Belhadj Bouchaib, Ain Temouchent, Algeria
2 shared publications - Rachid Saim
Abou Bekr Belkaid University
2 shared publications - Rafic Younes
Lebanese University
2 shared publications - Abdelaziz Begag
Abou Bekr Belkaid University
1 shared publication
Latest Publications
- 1 September 2025
- Published by International Centre for Applied Thermodynamics (ICAT) in International Journal of Thermodynamics
- Vol. 28 (3) , 142-151
Impact of Conical and Fusiform Turbulators on Heat Transfer Enhancement and Pressure Drop Inside a Double-Tube Heat Exchanger
This study focuses on enhancing heat transfer in a concentric double-tube heat exchanger by incorporating internal turbulators of two distinct geometries: conical and fusiform. The study numerically investigates the impact of these turbulators, placed within the inner tube, on turbulent flow and thermal performance over a Reynolds number range of 4000 to 12,000. A numerical study was carried out using ANSYS Fluent 16.0 software, where the governing equations were solved by the finite volume method. The Realizable k–ε turbulence model was used to capture the effects of turbulence on the flow field. Key performance indicators such as the Nusselt number and pressure drop were analyzed for both configurations. The results reveal that fusiform turbulators provide superior thermal enhancement, increasing the average Nusselt number by up to 34% compared to a smooth tube. However, this enhancement is accompanied by a significant increase in pressure drop across all tested cases, underlining the trade-off between heat transfer improvement and flow resistance. These findings demonstrate the effectiveness of fusiform geometries in improving the thermohydraulic efficiency of tubular heat exchangers.
- 1 September 2025
- Published by International Centre for Applied Thermodynamics (ICAT) in International Journal of Thermodynamics
- Vol. 28 (3) , 142-151
Impact of Conical and Fusiform Turbulators on Heat Transfer Enhancement and Pressure Drop Inside a Double-Tube Heat Exchanger
This study focuses on enhancing heat transfer in a concentric double-tube heat exchanger by incorporating internal turbulators of two distinct geometries: conical and fusiform. The study numerically investigates the impact of these turbulators, placed within the inner tube, on turbulent flow and thermal performance over a Reynolds number range of 4000 to 12,000. A numerical study was carried out using ANSYS Fluent 16.0 software, where the governing equations were solved by the finite volume method. The Realizable k–ε turbulence model was used to capture the effects of turbulence on the flow field. Key performance indicators such as the Nusselt number and pressure drop were analyzed for both configurations. The results reveal that fusiform turbulators provide superior thermal enhancement, increasing the average Nusselt number by up to 34% compared to a smooth tube. However, this enhancement is accompanied by a significant increase in pressure drop across all tested cases, underlining the trade-off between heat transfer improvement and flow resistance. These findings demonstrate the effectiveness of fusiform geometries in improving the thermohydraulic efficiency of tubular heat exchangers.
- Open Access
- 1 June 2025
- Published by National University of Architecture and Construction of Armenia in Journal of Architectural and Engineering Research
- Vol. 8, 49-61
Thermal Performance Evaluation of Traditional Buildings Flat Roofs in a Hot and Arid Climate of Algeria
This investigation aims to apply the analytical method of admittance for determining the thermal performance of composite flat roofs in traditional houses located in the southern region of Algeria, characterized by hot and arid climate conditions. The effect of adding insulation to the composition of flat roofs in traditional houses is studied by varying its, type, location and thickness. In this study, nine configurations of composite flat roof systems were manufactured using multiple layers with five types of insulations. Moreover, different dynamical thermal parameters are analyzed in this study, namely time lag (TL), decrement factor (DF), admittance (Y), transmittance (U), and surface factor (SF). The main results revealed that the roof configuration of R8 with insulation based on formaldehyde board presents a high value of TL (9.94 hours) and the lowest value of DF (0.1). In contrast, the configurations without insulation addition (R1, R2, and R3) display the lowest values of TL (4.91, 4.74, and 4.81, respectively) and the highest values of DF (0.59, 063, and 0.62, respectively). This research is useful for clearly understanding the thermal performance of composite flat roofs for the improvement of the energetic efficiency of traditional buildings.
- 1 June 2025
- Published by National University of Architecture and Construction of Armenia in Journal of Architectural and Engineering Research
- Vol. 8, 49-61
Open AccessThermal Performance Evaluation of Traditional Buildings Flat Roofs in a Hot and Arid Climate of Algeria
This investigation aims to apply the analytical method of admittance for determining the thermal performance of composite flat roofs in traditional houses located in the southern region of Algeria, characterized by hot and arid climate conditions. The effect of adding insulation to the composition of flat roofs in traditional houses is studied by varying its, type, location and thickness. In this study, nine configurations of composite flat roof systems were manufactured using multiple layers with five types of insulations. Moreover, different dynamical thermal parameters are analyzed in this study, namely time lag (TL), decrement factor (DF), admittance (Y), transmittance (U), and surface factor (SF). The main results revealed that the roof configuration of R8 with insulation based on formaldehyde board presents a high value of TL (9.94 hours) and the lowest value of DF (0.1). In contrast, the configurations without insulation addition (R1, R2, and R3) display the lowest values of TL (4.91, 4.74, and 4.81, respectively) and the highest values of DF (0.59, 063, and 0.62, respectively). This research is useful for clearly understanding the thermal performance of composite flat roofs for the improvement of the energetic efficiency of traditional buildings.
- Open Access
- 4 January 2025
- Published by Arab Academy for Science, Technology, and Maritime Transport (AASTMT) in Renewable Energy and Sustainable Development
- Vol. 11 (1) , 27-63
Numerical analysis of baffles on geothermal energy in a U-shaped heat exchanger
Numerical analysis of baffles on geothermal energy in a U-shaped heat exchanger
- 4 January 2025
- Published by Arab Academy for Science, Technology, and Maritime Transport (AASTMT) in Renewable Energy and Sustainable Development
- Vol. 11 (1) , 27-63
Open AccessNumerical analysis of baffles on geothermal energy in a U-shaped heat exchanger
Numerical analysis of baffles on geothermal energy in a U-shaped heat exchanger
- Open Access
- 26 October 2023
- Published by Centre de Developpement des Energie Renouvelables in Journal of Renewable Energies
- Vol. 12 (1) , 117-124
Simulation des transferts thermiques transitoires à travers un mur multicouche soumis à des conditions de flux solaire et de convection
On propose une étude numérique, par différences finies, du transfert de chaleur dans un mur multicouche (à deux ou trois couches) soumis à une condition de rayonnement solaire sur le côté extérieur et prenant en compte les échanges de chaleur par convection sur ses deux faces. L’exploitation du code numérique est développée sur des cas relatifs au problème posé dans l’habitat. Les résultats numériques sont présentés sur des exemples de matériaux utilisés dans le domaine du bâtiment dans des conditions réelles de fonctionnement (flux solaire, pertes convectives, etc…). On analyse également, l’influence, sur le transfert de chaleur, de quelques paramètres clés du système comme le choix des matériaux, l’optimisation de leur épaisseur et également la nature variable du flux solaire. Une proposition optimale sera dégagée de cette étude en fonction des objectifs recherchés.
- 26 October 2023
- Published by Centre de Developpement des Energie Renouvelables in Journal of Renewable Energies
- Vol. 12 (1) , 117-124
Open AccessSimulation des transferts thermiques transitoires à travers un mur multicouche soumis à des conditions de flux solaire et de convection
On propose une étude numérique, par différences finies, du transfert de chaleur dans un mur multicouche (à deux ou trois couches) soumis à une condition de rayonnement solaire sur le côté extérieur et prenant en compte les échanges de chaleur par convection sur ses deux faces. L’exploitation du code numérique est développée sur des cas relatifs au problème posé dans l’habitat. Les résultats numériques sont présentés sur des exemples de matériaux utilisés dans le domaine du bâtiment dans des conditions réelles de fonctionnement (flux solaire, pertes convectives, etc…). On analyse également, l’influence, sur le transfert de chaleur, de quelques paramètres clés du système comme le choix des matériaux, l’optimisation de leur épaisseur et également la nature variable du flux solaire. Une proposition optimale sera dégagée de cette étude en fonction des objectifs recherchés.
- Open Access
- 28 February 2022
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 40 (1) , 157-166
Numerical Study of Laminar Fluid Flow Around Two Heated Wall-Mounted Perforated Cubes in Tandem Arrangement
In this study, the forced convection of a stationary laminar flow over two heated wall-mounted perforated cubes are presented. These two cubes are placed in a tandem arrangement on a flat plate. The equations of continuity, momentum and energy are solved using the finite volume method based on the Rhie and Chow method for velocity-pressure coupling. The influence of the perforation volume of the cubes is studied and compared with the case of obstacles without holes for a constant heat flux subjected to the solid part. The results of mean Nusselt number and drag coefficients are presented at the levels of the two obstacles and the plane plate for different Reynolds numbers and different distances between them. The results showed that the insertion of holes in the cubes improves heat transfer from the diameter D/H=0.62, and this transfer rises with increasing diameter of the perforation of the cubes. The results showed also a decrease in the drag coefficient for the first obstacle with rising volume of the perforation.
- 28 February 2022
- Published by International Information and Engineering Technology Association in International Journal of Heat and Technology
- Vol. 40 (1) , 157-166
Open AccessNumerical Study of Laminar Fluid Flow Around Two Heated Wall-Mounted Perforated Cubes in Tandem Arrangement
In this study, the forced convection of a stationary laminar flow over two heated wall-mounted perforated cubes are presented. These two cubes are placed in a tandem arrangement on a flat plate. The equations of continuity, momentum and energy are solved using the finite volume method based on the Rhie and Chow method for velocity-pressure coupling. The influence of the perforation volume of the cubes is studied and compared with the case of obstacles without holes for a constant heat flux subjected to the solid part. The results of mean Nusselt number and drag coefficients are presented at the levels of the two obstacles and the plane plate for different Reynolds numbers and different distances between them. The results showed that the insertion of holes in the cubes improves heat transfer from the diameter D/H=0.62, and this transfer rises with increasing diameter of the perforation of the cubes. The results showed also a decrease in the drag coefficient for the first obstacle with rising volume of the perforation.
- Open Access
- 7 December 2021
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 89 (2) , 114-127
Numerical Analysis of The Thermo-Convective Behaviour of an Al2O3-H2O Nanofluid Flow Inside a Channel with Trapezoidal Corrugations
In this present article, a study of the dynamic and thermal behavior of the Al2O3-water nanofluid flow through a channel provided with trapezoidal undulations, under the action of a constant heat flux. To do this, the effect of various volume fractions (0-4%) and that of the nanoparticle diameter (30, 40, 60 nm) on the heat transfer and pressure drop within the channel was analyzed, for a range of Reynolds numbers between 100 to 1000. The equations governing the fluid flow, namely the equations of continuity, momentum and energy were integrated and discretized based on the finite volume method (FVM). The obtained results indicated that using nanofluids with a high-volume fraction and a small nanoparticle diameter makes it possible to improve the performance of the system in terms of heat transfer, pressure drop and friction factor.
- 7 December 2021
- Published by Akademia Baru Publishing in Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
- Vol. 89 (2) , 114-127
Open AccessNumerical Analysis of The Thermo-Convective Behaviour of an Al2O3-H2O Nanofluid Flow Inside a Channel with Trapezoidal Corrugations
In this present article, a study of the dynamic and thermal behavior of the Al2O3-water nanofluid flow through a channel provided with trapezoidal undulations, under the action of a constant heat flux. To do this, the effect of various volume fractions (0-4%) and that of the nanoparticle diameter (30, 40, 60 nm) on the heat transfer and pressure drop within the channel was analyzed, for a range of Reynolds numbers between 100 to 1000. The equations governing the fluid flow, namely the equations of continuity, momentum and energy were integrated and discretized based on the finite volume method (FVM). The obtained results indicated that using nanofluids with a high-volume fraction and a small nanoparticle diameter makes it possible to improve the performance of the system in terms of heat transfer, pressure drop and friction factor.
- 18 December 2019
- Published by Taylor & Francis in Numerical Heat Transfer, Part B: Fundamentals
- Vol. 77 (3) , 257-270
Effect of the presence of a shoulder on the thermal and dynamic structure of a laminar flow in an air-plane solar collector
A numerical study of the forced convection of a two-dimensional laminar air flow through a rectangular pipe with a shoulder is presented. The profiles and contours of velocity and temperature were analyzed in detail. The effects of the location of this shoulder on the insulation and on the absorber, and its height on the variations of the temperature and the velocity at the exit of the collector were also studied and compared with the case without shoulder, for a flow rate varying between 20 and 80 m3/h. The results show that the use of a shoulder placed on the insulator or on the absorber contributes to increasing the dynamic and thermal performance of the flow compared to the simple case; an average temperature gain of 25.52 °C at 56.6 °C is obtained for the low and high flow rates, respectively. The study also revealed that the use of the largest height h3 rated absorber can significantly increase the velocity (of the order of 222%) compared to the simple case. In addition, this location allows to direct the flow at the entrance of the drying chamber downwards, which leads to better evacuation of moist air at the chimney outlet.
- 18 December 2019
- Published by Taylor & Francis in Numerical Heat Transfer, Part B: Fundamentals
- Vol. 77 (3) , 257-270
Effect of the presence of a shoulder on the thermal and dynamic structure of a laminar flow in an air-plane solar collector
A numerical study of the forced convection of a two-dimensional laminar air flow through a rectangular pipe with a shoulder is presented. The profiles and contours of velocity and temperature were analyzed in detail. The effects of the location of this shoulder on the insulation and on the absorber, and its height on the variations of the temperature and the velocity at the exit of the collector were also studied and compared with the case without shoulder, for a flow rate varying between 20 and 80 m3/h. The results show that the use of a shoulder placed on the insulator or on the absorber contributes to increasing the dynamic and thermal performance of the flow compared to the simple case; an average temperature gain of 25.52 °C at 56.6 °C is obtained for the low and high flow rates, respectively. The study also revealed that the use of the largest height h3 rated absorber can significantly increase the velocity (of the order of 222%) compared to the simple case. In addition, this location allows to direct the flow at the entrance of the drying chamber downwards, which leads to better evacuation of moist air at the chimney outlet.
- Open Access
- 16 October 2019
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 23 (11) , 4949-4959
Unsaturated Soil Hydraulic Properties Identification using Numerical Inversion and In-Situ Experiments from Mnasra Area, Morocco
- 16 October 2019
- Published by Elsevier in KSCE Journal of Civil Engineering
- Vol. 23 (11) , 4949-4959
Open AccessUnsaturated Soil Hydraulic Properties Identification using Numerical Inversion and In-Situ Experiments from Mnasra Area, Morocco
- Open Access
- 1 January 2018
- Published by Walter de Gruyter GmbH in Mechanics and Mechanical Engineering
- Vol. 22 (1) , 253-272
Applying CFD for Studying the Dynamic and Thermal Behavior of an Indirect Solar Dryer: Paramertric Analysis
In this work, an indirect solar dryer integrated thermal storage for drying figs. (Ficuscarica) is studied numerically. Unsteady turbulent airflow and heat transfer through a two-dimensional model is carried out for a typical day of August under the climatic conditions of Tlemcen (Algeria). Effects of air inlet size and thickness of the packed bed on the dynamic and thermal behaviors of the dryer with and without packed bed have been discussed. The study shows that: (1) Increase the inlet size from 0.04 m to 0.10 m can accelerate the extraction of air by about 13% and reduce the maximum crops temperature by about 14%. (2) The packed bed can reduce the mass flow rate extracted by 22% and the fluctuations of air temperature by 1.3%. (3) A packed bed with a thickness of 0.15 m can extend the operating time of the dryer up to 23%.
- 1 January 2018
- Published by Walter de Gruyter GmbH in Mechanics and Mechanical Engineering
- Vol. 22 (1) , 253-272
Open AccessApplying CFD for Studying the Dynamic and Thermal Behavior of an Indirect Solar Dryer: Paramertric Analysis
In this work, an indirect solar dryer integrated thermal storage for drying figs. (Ficuscarica) is studied numerically. Unsteady turbulent airflow and heat transfer through a two-dimensional model is carried out for a typical day of August under the climatic conditions of Tlemcen (Algeria). Effects of air inlet size and thickness of the packed bed on the dynamic and thermal behaviors of the dryer with and without packed bed have been discussed. The study shows that: (1) Increase the inlet size from 0.04 m to 0.10 m can accelerate the extraction of air by about 13% and reduce the maximum crops temperature by about 14%. (2) The packed bed can reduce the mass flow rate extracted by 22% and the fluctuations of air temperature by 1.3%. (3) A packed bed with a thickness of 0.15 m can extend the operating time of the dryer up to 23%.
- 16 September 2017
- Published by Walter de Gruyter GmbH in International Journal of Food Engineering
- Vol. 13 (11)
Applying CFD for Studying the Dynamic and Thermal Behavior of Solar Chimney Drying System with Reversed Absorber
This article provides numerical study of the solar chimney (SC) assembled with a reversed absorber and packed bed for the indirect-mode solar dryer. The present study was designed to determine the effects of using the SC in three configuration and physical proprieties of the packed (thickness and porosity) on the dynamic and thermal behavior of airflow. The results reveal that (1) using SC without storage material can increase the maximum mass flow rate up to 5%. However, integrating a storage material in the SC can improve the mass flow rate up to 32% during nighttime; (2) the use of a packed bed can decrease the crops temperature fluctuation until about 76% and increase the operating time of the solar dryer up to 12.5 hours rather than 10 hours in the case without packed bed; (3) increasing the porosity from 0.1 to 0.8 can increase the maximum temperature by about 10°C.
- 16 September 2017
- Published by Walter de Gruyter GmbH in International Journal of Food Engineering
- Vol. 13 (11)
Applying CFD for Studying the Dynamic and Thermal Behavior of Solar Chimney Drying System with Reversed Absorber
This article provides numerical study of the solar chimney (SC) assembled with a reversed absorber and packed bed for the indirect-mode solar dryer. The present study was designed to determine the effects of using the SC in three configuration and physical proprieties of the packed (thickness and porosity) on the dynamic and thermal behavior of airflow. The results reveal that (1) using SC without storage material can increase the maximum mass flow rate up to 5%. However, integrating a storage material in the SC can improve the mass flow rate up to 32% during nighttime; (2) the use of a packed bed can decrease the crops temperature fluctuation until about 76% and increase the operating time of the solar dryer up to 12.5 hours rather than 10 hours in the case without packed bed; (3) increasing the porosity from 0.1 to 0.8 can increase the maximum temperature by about 10°C.