Jasmine Y. Liang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jasmine Y. Liang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Gregory J. Welk
1 shared publication- Hsiang-Chin Hsu
Department of Emergency Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan
1 shared publication Jeni Lansing
1 shared publicationLi-Shan Chou
1 shared publication- Li-Shan Chou
Department of Kinesiology, Iowa State University, Ames, IA, USA
1 shared publication Mingyue Zhang
1 shared publication
Latest Publications
- Open Access
- 22 November 2024
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 5, e16
Center of mass acceleration during walking: comparison between IMU and camera-based motion capture methodologies
Placing an inertial measurement unit (IMU) at the 5th lumbar vertebra (L5) is a frequently employed method to assess the whole-body center of mass (CoM) motion during walking. However, such a fixed position approach does not account for instantaneous changes in body segment positions that change the CoM. Therefore, this study aimed to assess the congruence between CoM accelerations obtained from these two methods. The CoM positions were calculated based on trajectory data from 49 markers placed on bony landmarks, and its accelerations were computed using the finite-difference algorithm. Concurrently, accelerations were obtained with an IMU placed at L5, a proxy CoM position. Data were collected from 16 participants. Bland–Altman Limits of Agreement and Statistical Parametric Mapping approaches were used to examine the similarity and differences between accelerations directly obtained from the IMU and those derived from position data of the L5 marker (ML5) and whole-body CoM during a gait cycle. The correlation was moderate between IMU and CoM accelerations (r = 0.58) and was strong between IMU and ML5 or between CoM and ML5 accelerations (r = 0.76). There were significant differences in magnitudes between CoM and ML5 and between CoM and IMU accelerations along the anteroposterior and mediolateral directions during the early loading response, mid-stance, and terminal stance to pre-swing. Such comprehensive understanding of the similarity or discrepancy between CoM accelerations acquired by a single IMU and a camera-based motion capture system could further improve the development of wearable sensor technology for human movement analysis.
- 22 November 2024
- Published by Cambridge University Press (CUP) in Wearable Technologies
- Vol. 5, e16
Open AccessCenter of mass acceleration during walking: comparison between IMU and camera-based motion capture methodologies
Placing an inertial measurement unit (IMU) at the 5th lumbar vertebra (L5) is a frequently employed method to assess the whole-body center of mass (CoM) motion during walking. However, such a fixed position approach does not account for instantaneous changes in body segment positions that change the CoM. Therefore, this study aimed to assess the congruence between CoM accelerations obtained from these two methods. The CoM positions were calculated based on trajectory data from 49 markers placed on bony landmarks, and its accelerations were computed using the finite-difference algorithm. Concurrently, accelerations were obtained with an IMU placed at L5, a proxy CoM position. Data were collected from 16 participants. Bland–Altman Limits of Agreement and Statistical Parametric Mapping approaches were used to examine the similarity and differences between accelerations directly obtained from the IMU and those derived from position data of the L5 marker (ML5) and whole-body CoM during a gait cycle. The correlation was moderate between IMU and CoM accelerations (r = 0.58) and was strong between IMU and ML5 or between CoM and ML5 accelerations (r = 0.76). There were significant differences in magnitudes between CoM and ML5 and between CoM and IMU accelerations along the anteroposterior and mediolateral directions during the early loading response, mid-stance, and terminal stance to pre-swing. Such comprehensive understanding of the similarity or discrepancy between CoM accelerations acquired by a single IMU and a camera-based motion capture system could further improve the development of wearable sensor technology for human movement analysis.
- Open Access
- 30 April 2024
- Published by Elsevier in Archives of Gerontology and Geriatrics Plus
- Vol. 1 (3)
Estimation of STEADI performance using inertial measurement unit
- 30 April 2024
- Published by Elsevier in Archives of Gerontology and Geriatrics Plus
- Vol. 1 (3)
Open AccessEstimation of STEADI performance using inertial measurement unit
- 6 September 2018
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 37 (5) , 544-552
Collegiate baseball players with more optimal functional movement patterns demonstrate better athletic performance in speed and agility
Sports injuries are common among baseball players and may result in abnormal movement patterns, increased risks of future injury, and unsatisfactory performance. The Functional Movement Screen (FMS™) has been developed to detect abnormal functional movement patterns and can be used for predicting risks of sports injury. However, whether FMS™ scores are associated with athletic performance remains unclear. The goal of this study was to determine the association between functional movements and athletic performance in elite baseball players. Core stability, muscular strength and flexibility of the lower extremities, and FMS™, as well as athletic performance in sprinting, agility, and balance tests were assessed in 52 male collegiate Division I baseball players placed into two groups based on FMS™ scores. The high-scoring group demonstrated better athletic performance than the low-scoring group, with a shorter duration of the agility test. No group differences were found in core stability, muscular strength, or muscle flexibility, except for rectus femoris flexibility. Thus, the FMS™ score is associated with sprinting and agility performance in elite baseball players. These findings indicate that the FMS™ may have a role in predicting athletic performance and thereby help determine the goals of training regimens or return-to-play strategies.
- 6 September 2018
- Published by Taylor & Francis in Journal of Sports Sciences
- Vol. 37 (5) , 544-552
Collegiate baseball players with more optimal functional movement patterns demonstrate better athletic performance in speed and agility
Sports injuries are common among baseball players and may result in abnormal movement patterns, increased risks of future injury, and unsatisfactory performance. The Functional Movement Screen (FMS™) has been developed to detect abnormal functional movement patterns and can be used for predicting risks of sports injury. However, whether FMS™ scores are associated with athletic performance remains unclear. The goal of this study was to determine the association between functional movements and athletic performance in elite baseball players. Core stability, muscular strength and flexibility of the lower extremities, and FMS™, as well as athletic performance in sprinting, agility, and balance tests were assessed in 52 male collegiate Division I baseball players placed into two groups based on FMS™ scores. The high-scoring group demonstrated better athletic performance than the low-scoring group, with a shorter duration of the agility test. No group differences were found in core stability, muscular strength, or muscle flexibility, except for rectus femoris flexibility. Thus, the FMS™ score is associated with sprinting and agility performance in elite baseball players. These findings indicate that the FMS™ may have a role in predicting athletic performance and thereby help determine the goals of training regimens or return-to-play strategies.