Mohammad Amin Bahmani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mohammad Amin Bahmani has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Torbjorn Thiringer
Division of Electric Power Engineering, Chalmers University of Technology, Gothenburg, Sweden
6 shared publications A. Karimi
2 shared publicationsE. Agheb
NTNU 1 Department of Electrical Power Engineering Trondheim N-7491, Norway
2 shared publicationsH. K. Høidalen
Department of Electrical Power Engineering, NTNU 2 , Trondheim N-7491, Norway
2 shared publicationsK. Niayesh
2 shared publications- Mohammad Kharezy
SP Technical Research Institute of Sweden, Borås, Sweden
2 shared publications
Latest Publications
- 21 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (5) , 4225-4233
Design Methodology and Optimization of a Medium-Frequency Transformer for High-Power DC–DC Applications
The medium-frequency power transformer (MFPT) is one of the key elements of an isolated bi-directional dc-dc converters in applications such as future all-dc offshore wind farms, traction, and solid state transformers. This paper describes a design methodology taking into account loss calculation, isolation requirements, and thermal management. Incorporating this design methodology, an optimization process with a wide range of parameter variations is applied on a design example to find the highest power density while the efficiency, isolation, thermal, and leakage inductance requirements are all met.
- 21 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 52 (5) , 4225-4233
Design Methodology and Optimization of a Medium-Frequency Transformer for High-Power DC–DC Applications
The medium-frequency power transformer (MFPT) is one of the key elements of an isolated bi-directional dc-dc converters in applications such as future all-dc offshore wind farms, traction, and solid state transformers. This paper describes a design methodology taking into account loss calculation, isolation requirements, and thermal management. Incorporating this design methodology, an optimization process with a wide range of parameter variations is applied on a design example to find the highest power density while the efficiency, isolation, thermal, and leakage inductance requirements are all met.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3043-3050
Optimization and experimental validation of medium-frequency high power transformers in solid-state transformer applications
High power isolated DC-DC converters are likely to provide solutions for many technical challenges associated with power density, efficiency and reliability in potential applications such as offshore wind farms, inter-connection of DC grids, MVDC in data centers and in future solid state transformer applications. The high power medium frequency transformer (HPMFT) is one of the key elements of such a converter to realize the voltage adaption, isolation requirements, as well as high power density. This paper describes a design and optimization methodology taking into account the loss calculation, isolation requirements and thermal management. Incorporating this design methodology, an optimization process with a wide range of parameter variations is applied on a 50 kW, 1 / 3 kV, 5 kHz transformer to find the highest power density while the efficiency, isolation, thermal and leakage inductance requirements are all met. The optimized transformers are then manufactured and will be presented in this paper.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3043-3050
Optimization and experimental validation of medium-frequency high power transformers in solid-state transformer applications
High power isolated DC-DC converters are likely to provide solutions for many technical challenges associated with power density, efficiency and reliability in potential applications such as offshore wind farms, inter-connection of DC grids, MVDC in data centers and in future solid state transformer applications. The high power medium frequency transformer (HPMFT) is one of the key elements of such a converter to realize the voltage adaption, isolation requirements, as well as high power density. This paper describes a design and optimization methodology taking into account the loss calculation, isolation requirements and thermal management. Incorporating this design methodology, an optimization process with a wide range of parameter variations is applied on a 50 kW, 1 / 3 kV, 5 kHz transformer to find the highest power density while the efficiency, isolation, thermal and leakage inductance requirements are all met. The optimized transformers are then manufactured and will be presented in this paper.
- 26 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 31 (2) , 857-866
Comparative Study of a Multi-MW High-Power Density DC Transformer With an Optimized High-Frequency Magnetics in All-DC Offshore Wind Farm
In this paper, the design of a 1/30 kV, 10 MW modular isolated dc-dc converter is presented. The design and optimization of a high-frequency transformer as the key part of such a converter is addressed. Efficiency curves for different semiconductors and frequencies are presented in order to find an optimum frequency-enabling adequate transformer volume reduction with a suitable compromise with the converter efficiency. It was found that for this voltage level and size, it is no point to go above 6 kHz from the transformer perspective since the isolation requirement that leads to that the size is not reduced much more for even higher frequencies. At 5 kHz, the efficiency of the transformer having a nanocrystalline core reached 99.7% while the power density was about 22 kW/l. For the entire dc-dc converter, an efficiency of 98.5% was reached at 5 kHz switching frequency using SiC metal-oxide semiconductor field-effect transistors as switching elements while the efficiency when using insulated-gate bipolar transistors reached 97.2% at the same frequency.
- 26 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 31 (2) , 857-866
Comparative Study of a Multi-MW High-Power Density DC Transformer With an Optimized High-Frequency Magnetics in All-DC Offshore Wind Farm
In this paper, the design of a 1/30 kV, 10 MW modular isolated dc-dc converter is presented. The design and optimization of a high-frequency transformer as the key part of such a converter is addressed. Efficiency curves for different semiconductors and frequencies are presented in order to find an optimum frequency-enabling adequate transformer volume reduction with a suitable compromise with the converter efficiency. It was found that for this voltage level and size, it is no point to go above 6 kHz from the transformer perspective since the isolation requirement that leads to that the size is not reduced much more for even higher frequencies. At 5 kHz, the efficiency of the transformer having a nanocrystalline core reached 99.7% while the power density was about 22 kW/l. For the entire dc-dc converter, an efficiency of 98.5% was reached at 5 kHz switching frequency using SiC metal-oxide semiconductor field-effect transistors as switching elements while the efficiency when using insulated-gate bipolar transistors reached 97.2% at the same frequency.
- 14 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 30 (10) , 5738-5745
Accurate Evaluation of Leakage Inductance in High-Frequency Transformers Using an Improved Frequency-Dependent Expression
Moving toward higher power density in magnetic components, which is often realized by increasing the operating frequency, leads to the need for development of more accurate design tools, for example, more accurate expressions for core losses, winding losses, and leakage inductance calculations. This paper presents a new analytical expression intended to accurately evaluate the leakage inductance of transformers in the high-frequency range in which the behavior of the magnetic field within the windings is altered. Unlike conventional expressions, which usually overestimate the leakage inductance at higher frequencies, this expression accounts for high-frequency behavior of the magnetic field and provides high accuracy when operating at high frequencies. These high accuracy and applicability makes the derived expression of interest for designers to avoid time consuming finite-element simulations without compromising with accuracy. The expression is validated by 2-D finite-element method simulation, as well as by measurements.
- 14 November 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 30 (10) , 5738-5745
Accurate Evaluation of Leakage Inductance in High-Frequency Transformers Using an Improved Frequency-Dependent Expression
Moving toward higher power density in magnetic components, which is often realized by increasing the operating frequency, leads to the need for development of more accurate design tools, for example, more accurate expressions for core losses, winding losses, and leakage inductance calculations. This paper presents a new analytical expression intended to accurately evaluate the leakage inductance of transformers in the high-frequency range in which the behavior of the magnetic field within the windings is altered. Unlike conventional expressions, which usually overestimate the leakage inductance at higher frequencies, this expression accounts for high-frequency behavior of the magnetic field and provides high accuracy when operating at high frequencies. These high accuracy and applicability makes the derived expression of interest for designers to avoid time consuming finite-element simulations without compromising with accuracy. The expression is validated by 2-D finite-element method simulation, as well as by measurements.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 29 (8) , 4231-4246
An Accurate Pseudoempirical Model of Winding Loss Calculation in HF Foil and Round Conductors in Switchmode Magnetics
When operating higher up in frequency, the copper losses in transformer windings will significantly rise due to enhanced skin and proximity effect. This leads to a high need to develop new methods to accurately evaluate winding losses at higher frequencies. This paper investigates the effect of different geometrical parameters at a wide range of frequencies in order to propose a pseudoempirical formula for winding loss calculation in high-frequency transformers. A comprehensive analysis of the edge effect and ac resistance is done by performing more than 12 300 2-D finite element simulations on foil and round conductors. Unlike previous studies which mostly focused on specific case studies with limited applications, this model provides very high accuracy, especially where the most common analytical models drastically underestimate the winding losses, with a wide-range applicability which could be of interest for designers to avoid time consuming FEM simulation without compromising with the accuracy. Several transformers are built and the model is experimentally verified with a good agreement.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 29 (8) , 4231-4246
An Accurate Pseudoempirical Model of Winding Loss Calculation in HF Foil and Round Conductors in Switchmode Magnetics
When operating higher up in frequency, the copper losses in transformer windings will significantly rise due to enhanced skin and proximity effect. This leads to a high need to develop new methods to accurately evaluate winding losses at higher frequencies. This paper investigates the effect of different geometrical parameters at a wide range of frequencies in order to propose a pseudoempirical formula for winding loss calculation in high-frequency transformers. A comprehensive analysis of the edge effect and ac resistance is done by performing more than 12 300 2-D finite element simulations on foil and round conductors. Unlike previous studies which mostly focused on specific case studies with limited applications, this model provides very high accuracy, especially where the most common analytical models drastically underestimate the winding losses, with a wide-range applicability which could be of interest for designers to avoid time consuming FEM simulation without compromising with the accuracy. Several transformers are built and the model is experimentally verified with a good agreement.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21645256,p. 358-363
A high accuracy regressive-derived winding loss calculation model for high frequency applications
When operating higher up in frequency, the copper losses in transformer windings will significantly rise due to enhanced skin and proximity effect. This leads to a high need to propose and develop new methods to accurately evaluate winding losses at higher frequencies. This paper investigates the effect of different geometrical parameters at a wide range of frequencies in order to propose a pseudo-empirical formula for winding loss calculation in high frequency transformers. A comprehensive analysis of the edge effect and AC resistance is done by performing more than 12300 2-D finite element simulations on foil and round conductors. Unlike previous studies which mostly focused on specific case studies with limited applications, this model provides very high accuracy, especially where the most common analytical models drastically underestimate the winding losses. Moreover the model has a wide-range applicability which could be of interest for designers to avoid time consuming FEM simulation without compromising with the accuracy.
- 1 April 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21645256,p. 358-363
A high accuracy regressive-derived winding loss calculation model for high frequency applications
When operating higher up in frequency, the copper losses in transformer windings will significantly rise due to enhanced skin and proximity effect. This leads to a high need to propose and develop new methods to accurately evaluate winding losses at higher frequencies. This paper investigates the effect of different geometrical parameters at a wide range of frequencies in order to propose a pseudo-empirical formula for winding loss calculation in high frequency transformers. A comprehensive analysis of the edge effect and AC resistance is done by performing more than 12300 2-D finite element simulations on foil and round conductors. Unlike previous studies which mostly focused on specific case studies with limited applications, this model provides very high accuracy, especially where the most common analytical models drastically underestimate the winding losses. Moreover the model has a wide-range applicability which could be of interest for designers to avoid time consuming FEM simulation without compromising with the accuracy.
- 1 May 2012
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 4 (3) , 033113
Core loss behavior in high frequency high power transformers—II: Arbitrary excitation
High frequency high power transformers used in power electronic converters are frequently subjected to non-sinusoidal excitations. The main purpose of this paper is to study the effects of some general arbitrary waveforms on magnetic core loss in these transformers. First, using well-known empirical equations, general expressions were derived based on the parameters of the waveforms. Second, the impacts of different orders of voltage harmonics were investigated. Finally, capabilities of nanocrystalline and amorphous magnetic materials were compared. It is shown that the loss inside the core is highly sensitive to the rise time and duty cycle of trapezoidal and rectangular waveforms, respectively. Furthermore, although amorphous materials have higher saturation flux density, the total core loss inside the transformer designed using nanocrystalline material is considerably lower than the similar transformer with amorphous materials.
- 1 May 2012
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 4 (3) , 033113
Core loss behavior in high frequency high power transformers—II: Arbitrary excitation
High frequency high power transformers used in power electronic converters are frequently subjected to non-sinusoidal excitations. The main purpose of this paper is to study the effects of some general arbitrary waveforms on magnetic core loss in these transformers. First, using well-known empirical equations, general expressions were derived based on the parameters of the waveforms. Second, the impacts of different orders of voltage harmonics were investigated. Finally, capabilities of nanocrystalline and amorphous magnetic materials were compared. It is shown that the loss inside the core is highly sensitive to the rise time and duty cycle of trapezoidal and rectangular waveforms, respectively. Furthermore, although amorphous materials have higher saturation flux density, the total core loss inside the transformer designed using nanocrystalline material is considerably lower than the similar transformer with amorphous materials.
- 1 May 2012
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 4 (3) , 033112
Core loss behavior in high frequency high power transformers—I: Effect of core topology
This two-part paper presents an overview of core loss computations performed in both time and frequency domains in order to evaluate their behavior in single phase transformers with different core topologies. Moreover, the effects of non-sinusoidal waveforms on well-known core loss calculation methods are investigated with both analytically and finite element calculations. Three well-known configurations of transformers utilized in high frequency high power applications are investigated, namely, the core type, the shell type, and the matrix transformer. Based on the results obtained from a large number of FEM simulations for different operating conditions, the efficiencies of the transformers are compared in terms of distribution of magnetic flux density, loss density, total core loss, and weight. The analysis shows that for lower range of frequency and power, the shell type core could be the favorable option, and on the other hand, core type seems to be an appropriate solution for higher values of the operating frequency and nominal power.
- 1 May 2012
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 4 (3) , 033112
Core loss behavior in high frequency high power transformers—I: Effect of core topology
This two-part paper presents an overview of core loss computations performed in both time and frequency domains in order to evaluate their behavior in single phase transformers with different core topologies. Moreover, the effects of non-sinusoidal waveforms on well-known core loss calculation methods are investigated with both analytically and finite element calculations. Three well-known configurations of transformers utilized in high frequency high power applications are investigated, namely, the core type, the shell type, and the matrix transformer. Based on the results obtained from a large number of FEM simulations for different operating conditions, the efficiencies of the transformers are compared in terms of distribution of magnetic flux density, loss density, total core loss, and weight. The analysis shows that for lower range of frequency and power, the shell type core could be the favorable option, and on the other hand, core type seems to be an appropriate solution for higher values of the operating frequency and nominal power.
- 5 December 2009
- Published by Springer Nature in International Journal of Material Forming
- Vol. 3 (3) , 205-208
Magnetic field enhancement in electromagnetic forming systems using anisotropic materials
- 5 December 2009
- Published by Springer Nature in International Journal of Material Forming
- Vol. 3 (3) , 205-208
Magnetic field enhancement in electromagnetic forming systems using anisotropic materials