Susanne Röger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Susanne Röger has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
Martin Borggrefe
1st Department of Medicine - Cardiology, University Medical Centre Mannheim, D-68167 Mannheim, Germany
8 shared publications- Jürgen Kuschyk
First Department of Medicine, University Medical Center Mannheim, Germany (J.K.).
5 shared publications - Ibrahim Akin
Section of Invasive Cardiology and Electrophysiology, Department of Internal medicine I, University Medical Center Mannheim, Theodor-Kutzer Ufer 1-3, 68167 Mannheim, Germany
3 shared publications Jürgen Kuschyk
First Department of Medicine, Faculty of Medicine, University Medical Centre Mannheim (UMM), University of Heidelberg, Mannheim, Germany
3 shared publications- Benny Rousso
Impulse Dynamics, Hod Hasharon, Israel
2 shared publications Boris Rudic
First Department of Medicine, Faculty of Medicine, University Medical Centre Mannheim (UMM), University of Heidelberg, Mannheim, Germany
2 shared publications
Latest Publications
- Open Access
- 27 February 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (5) , 761-768
Incidence, mechanisms, and clinical impact of inappropriate shocks in patients with a subcutaneous defibrillator
Aims: Inappropriate shocks (IAS) remain a challenge for patients and physicians after implantation of the subcutaneous implantable cardioverter-defibrillator (S-ICD). The aims were to assess and characterize different patterns of IAS. Methods and results: Two hundred and thirty-nine patients were implanted with an S-ICD between 2010 and 2018 for primary and secondary prevention. Follow-up data of at least 6 months were analysed. During a mean follow-up of 34.9 ± 16.0 months, a total of 73 shocks occurred in 38 patients (6%). Forty-three (59%) shocks were considered appropriate due to ventricular tachycardia/ventricular fibrillation, while 30 (41%) were inappropriate and occurred in 19 patients (8%). Myopotentials/noise was the most frequent cause of inappropriate shocks (n = 8), followed by T-wave oversensing (n = 6) and undersensing of the QRS, resulting in adaptation of the automatic gain control and inappropriate shock (n = 5). Seventy-four percent of all IAS occurred on the primary vector, while no IAS occurred on the alternate vector. In seven of eight patients (88%), IAS related to myopotentials have occurred on the primary sensing vector. Multivariate analysis identified taller patients, primary sensing vector and first-generation S-ICD device as predictors for IAS. SMART pass effectively reduced the occurrence of IAS in the second-generation S-ICD system. Conclusion: Inappropriate therapies are less frequently observed on the alternate vector. The primary vector seems to be unfavourable with regard to oversensing caused by myopotentials. Inappropriate shocks were associated with an increased rate of rehospitalization but not mortality. These observations have implications for the prevention of inappropriate S-ICD shocks.
- 27 February 2020
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 22 (5) , 761-768
Open AccessIncidence, mechanisms, and clinical impact of inappropriate shocks in patients with a subcutaneous defibrillator
Aims: Inappropriate shocks (IAS) remain a challenge for patients and physicians after implantation of the subcutaneous implantable cardioverter-defibrillator (S-ICD). The aims were to assess and characterize different patterns of IAS. Methods and results: Two hundred and thirty-nine patients were implanted with an S-ICD between 2010 and 2018 for primary and secondary prevention. Follow-up data of at least 6 months were analysed. During a mean follow-up of 34.9 ± 16.0 months, a total of 73 shocks occurred in 38 patients (6%). Forty-three (59%) shocks were considered appropriate due to ventricular tachycardia/ventricular fibrillation, while 30 (41%) were inappropriate and occurred in 19 patients (8%). Myopotentials/noise was the most frequent cause of inappropriate shocks (n = 8), followed by T-wave oversensing (n = 6) and undersensing of the QRS, resulting in adaptation of the automatic gain control and inappropriate shock (n = 5). Seventy-four percent of all IAS occurred on the primary vector, while no IAS occurred on the alternate vector. In seven of eight patients (88%), IAS related to myopotentials have occurred on the primary sensing vector. Multivariate analysis identified taller patients, primary sensing vector and first-generation S-ICD device as predictors for IAS. SMART pass effectively reduced the occurrence of IAS in the second-generation S-ICD system. Conclusion: Inappropriate therapies are less frequently observed on the alternate vector. The primary vector seems to be unfavourable with regard to oversensing caused by myopotentials. Inappropriate shocks were associated with an increased rate of rehospitalization but not mortality. These observations have implications for the prevention of inappropriate S-ICD shocks.
- 31 December 2019
- Published by Rutgers University Press
- p. 271-286
CHAPTER 23. Iatrogenic Aspects in Cardiac Device
CHAPTER 23. Iatrogenic Aspects in Cardiac Device was published in Iatrogenicity on page 271.
- 31 December 2019
- Published by Rutgers University Press
- p. 271-286
CHAPTER 23. Iatrogenic Aspects in Cardiac Device
CHAPTER 23. Iatrogenic Aspects in Cardiac Device was published in Iatrogenicity on page 271.
- Open Access
- 26 April 2018
- Published by Wiley in Clinical Cardiology
- Vol. 41 (4) , 518-524
Long‐term results of combined cardiac contractility modulation and subcutaneous defibrillator therapy in patients with heart failure and reduced ejection fraction
Background: Cardiac contractility modulation (CCM) is an electrical‐device therapy for patients with heart failure with reduced ejection fraction (HFrEF). Patients with left ventricular ejection fraction (LVEF) ≤35% also have indication for an implantable cardioverter‐defibrillator (ICD), and in some cases subcutaneous ICD (S‐ICD) is selected.Hypothesis: CCM and S‐ICD can be combined to work efficaciously and safely.Methods: We report on 20 patients with HFrEF and LVEF ≤35% who received CCM and S‐ICD. To exclude device interference, patients received intraoperative crosstalk testing, S‐ICD testing, and bicycle exercise testing while CCM was activated. Clinical and QOL measures before CCM activation and at last follow‐up were analyzed. S‐ICD performance was evaluated while both CCM and S‐ICD were active.Results: Mean follow‐up was 34.3 months. NYHA class improved from 2.9 ± 0.4 to 2.1 ± 0.7 (P < 0.0001), Minnesota Living With Heart Failure Questionnaire score improved from 50.2 ± 23.7 to 29.6 ± 22.8 points (P < 0.0001), and LVEF improved from 24.4% ± 8.1% to 30.9% ± 9.6% (P = 0.002). Mean follow‐up time with both devices active was 22 months. Three patients experienced a total of 6 episodes of sustained ventricular tachycardia, all successfully treated with first ICD shock. One case received an inappropriate shock unrelated to the concomitant CCM. One patient received an LVAD, so CCM and S‐ICD were discontinued.Conclusions: CCM and S‐ICD can be successfully combined in patients with HFrEF. S‐ICD and CCM remain efficacious when used together, with no interference affecting their function.
- 26 April 2018
- Published by Wiley in Clinical Cardiology
- Vol. 41 (4) , 518-524
Open AccessLong‐term results of combined cardiac contractility modulation and subcutaneous defibrillator therapy in patients with heart failure and reduced ejection fraction
Background: Cardiac contractility modulation (CCM) is an electrical‐device therapy for patients with heart failure with reduced ejection fraction (HFrEF). Patients with left ventricular ejection fraction (LVEF) ≤35% also have indication for an implantable cardioverter‐defibrillator (ICD), and in some cases subcutaneous ICD (S‐ICD) is selected.Hypothesis: CCM and S‐ICD can be combined to work efficaciously and safely.Methods: We report on 20 patients with HFrEF and LVEF ≤35% who received CCM and S‐ICD. To exclude device interference, patients received intraoperative crosstalk testing, S‐ICD testing, and bicycle exercise testing while CCM was activated. Clinical and QOL measures before CCM activation and at last follow‐up were analyzed. S‐ICD performance was evaluated while both CCM and S‐ICD were active.Results: Mean follow‐up was 34.3 months. NYHA class improved from 2.9 ± 0.4 to 2.1 ± 0.7 (P < 0.0001), Minnesota Living With Heart Failure Questionnaire score improved from 50.2 ± 23.7 to 29.6 ± 22.8 points (P < 0.0001), and LVEF improved from 24.4% ± 8.1% to 30.9% ± 9.6% (P = 0.002). Mean follow‐up time with both devices active was 22 months. Three patients experienced a total of 6 episodes of sustained ventricular tachycardia, all successfully treated with first ICD shock. One case received an inappropriate shock unrelated to the concomitant CCM. One patient received an LVAD, so CCM and S‐ICD were discontinued.Conclusions: CCM and S‐ICD can be successfully combined in patients with HFrEF. S‐ICD and CCM remain efficacious when used together, with no interference affecting their function.
- Open Access
- 15 March 2018
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 18 (1) , 1-13
Therapy optimization in patients with heart failure: the role of the wearable cardioverter-defibrillator in a real-world setting
The wearable cardioverter-defibrillator (WCD) has emerged as a valuable tool to temporarily protect patients at risk for sudden cardiac death (SCD). The aim of this study was to determine the value of the WCD for therapy optimization of heart failure patients. One hundred five consecutive patients that received WCD between 4/2012 and 9/2016 were included in the study. All patients were followed for clinical outcome and echocardiographic parameters during WCD therapy and had continued follow-up after WCD therapy, irrespective of subsequent implantable cardioverter-defibrillator (ICD) implantation. The most common indication for WCD were newly diagnosed ischemic (ICM) or non-ischemic cardiomyopathy (NICM) with left ventricular ejection fraction (LVEF) ≤35%. Mean WCD wear time was 68.8 ± 50.4 days with a mean daily use of 21.5 ± 3.5 h. Five patients (4.8%) received a total of five appropriate WCD shocks. During WCD wear, patients with ICM and NICM showed significant improvement in LVEF, reducing the proportion of patients with a need for primary preventive ICD implantation to 54.8% (ICM) and 48.8% (NICM). An ICD was finally implanted in 51.4% of the study patients (24 trans-venous ICDs, 30 subcutaneous ICDs). After discontinuation of WCD therapy, all patients were followed for a mean of 18.6 ± 12.3 months. 5.6% of patients with implanted ICDs received appropriate therapies. No patient with subcutaneous ICD needed change to a trans-venous device. None of the patients without an implanted ICD suffered from ventricular tachyarrhythmias and no patient died suddenly. In patients with NICM a significant LVEF improvement was observed during long-term follow-up (from 34.8 ± 11.1% to 41.0 ± 10.2%). WCD therapy successfully bridged all patients to either LVEF recovery or ICD implantation. Following WCD, ICD implantation could be avoided in almost half of the patients. In selected patients, prolongation of WCD therapy beyond 3 months might further prevent unnecessary ICD implantation. The WCD as an external monitoring system contributed important information to optimize device selection in patients that needed ICD implantation.
- 15 March 2018
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 18 (1) , 1-13
Open AccessTherapy optimization in patients with heart failure: the role of the wearable cardioverter-defibrillator in a real-world setting
The wearable cardioverter-defibrillator (WCD) has emerged as a valuable tool to temporarily protect patients at risk for sudden cardiac death (SCD). The aim of this study was to determine the value of the WCD for therapy optimization of heart failure patients. One hundred five consecutive patients that received WCD between 4/2012 and 9/2016 were included in the study. All patients were followed for clinical outcome and echocardiographic parameters during WCD therapy and had continued follow-up after WCD therapy, irrespective of subsequent implantable cardioverter-defibrillator (ICD) implantation. The most common indication for WCD were newly diagnosed ischemic (ICM) or non-ischemic cardiomyopathy (NICM) with left ventricular ejection fraction (LVEF) ≤35%. Mean WCD wear time was 68.8 ± 50.4 days with a mean daily use of 21.5 ± 3.5 h. Five patients (4.8%) received a total of five appropriate WCD shocks. During WCD wear, patients with ICM and NICM showed significant improvement in LVEF, reducing the proportion of patients with a need for primary preventive ICD implantation to 54.8% (ICM) and 48.8% (NICM). An ICD was finally implanted in 51.4% of the study patients (24 trans-venous ICDs, 30 subcutaneous ICDs). After discontinuation of WCD therapy, all patients were followed for a mean of 18.6 ± 12.3 months. 5.6% of patients with implanted ICDs received appropriate therapies. No patient with subcutaneous ICD needed change to a trans-venous device. None of the patients without an implanted ICD suffered from ventricular tachyarrhythmias and no patient died suddenly. In patients with NICM a significant LVEF improvement was observed during long-term follow-up (from 34.8 ± 11.1% to 41.0 ± 10.2%). WCD therapy successfully bridged all patients to either LVEF recovery or ICD implantation. Following WCD, ICD implantation could be avoided in almost half of the patients. In selected patients, prolongation of WCD therapy beyond 3 months might further prevent unnecessary ICD implantation. The WCD as an external monitoring system contributed important information to optimize device selection in patients that needed ICD implantation.
- 9 February 2017
- Published by Springer Nature in Herzschrittmachertherapie + Elektrophysiologie
- Vol. 28 (1) , 64-66
Lebensrettender Schock durch einen subkutanen ICD während eines Fallschirmsprungs
- 9 February 2017
- Published by Springer Nature in Herzschrittmachertherapie + Elektrophysiologie
- Vol. 28 (1) , 64-66
Lebensrettender Schock durch einen subkutanen ICD während eines Fallschirmsprungs
- 1 January 2017
- Published by Elsevier in Journal of Cardiology
- Vol. 69 (1) , 326-332
Cardiac contractility modulation in heart failure patients: Randomized comparison of signal delivery through one vs. two ventricular leads
- 1 January 2017
- Published by Elsevier in Journal of Cardiology
- Vol. 69 (1) , 326-332
Cardiac contractility modulation in heart failure patients: Randomized comparison of signal delivery through one vs. two ventricular leads
- 1 November 2014
- Published by Elsevier in Journal of Electrocardiology
- Vol. 47 (6) , 936-940
Long term impact of cardiac contractility modulation on QRS duration
- 1 November 2014
- Published by Elsevier in Journal of Electrocardiology
- Vol. 47 (6) , 936-940
Long term impact of cardiac contractility modulation on QRS duration
- Open Access
- 4 April 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (8) , 1205-1209
Cardiac contractility modulation: first experience in heart failure patients with reduced ejection fraction and permanent atrial fibrillation
Cardiac contractility modulation (CCM) is an electrical therapy for heart failure (HF) with reduced ejection fraction. Sinus rhythm is deemed necessary for effective treatment because the current CCM signal delivery algorithm requires sequential sensing of a p wave, followed by depolarizations at each ventricular lead. In case of atrial fibrillation (AF) CCM is inhibited. This study demonstrates the feasibility of CCM therapy in patients with permanent AF by circumventing the requirement for sensing of a natural p wave. Five CCM patients with AF received a pacemaker or implantable cardioverter/defibrillator (ICD) upgrade to cardiac resynchronization therapy (CRT) with low atrial sensitivity, which resulted in compulsory atrial stimulation followed by biventricular pacing. The CCM system recognized the atrial stimuli as p waves, which led to CCM signal delivery. Three patients developed permanent AF after a mean follow-up of 40 months of CCM therapy. Two patients had permanent AF at the time of CCM device implantation. All pacemaker or ICD devices were successfully upgraded to CRT. Cardiac resynchronization therapy stimulation rates of ≥96% and CCM stimulation rates between 60% and 95% were achieved. Clinical condition of the patients improved (mean NYHA class −0.7, left ventricular ejection fraction +2%, Minnesota living with HF questionnaire −15.6 points). CCM signal delivery is feasible in HF patients with permanent AF by sequential atrial-ventricular pacing, so that the atrial pacing spike is interpreted as a p wave by the CCM signal delivery algorithm. This experimental approach can be considered in individual cases. A new CCM algorithm, which does not require an atrial electrode, is desirable.
- 4 April 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (8) , 1205-1209
Open AccessCardiac contractility modulation: first experience in heart failure patients with reduced ejection fraction and permanent atrial fibrillation
Cardiac contractility modulation (CCM) is an electrical therapy for heart failure (HF) with reduced ejection fraction. Sinus rhythm is deemed necessary for effective treatment because the current CCM signal delivery algorithm requires sequential sensing of a p wave, followed by depolarizations at each ventricular lead. In case of atrial fibrillation (AF) CCM is inhibited. This study demonstrates the feasibility of CCM therapy in patients with permanent AF by circumventing the requirement for sensing of a natural p wave. Five CCM patients with AF received a pacemaker or implantable cardioverter/defibrillator (ICD) upgrade to cardiac resynchronization therapy (CRT) with low atrial sensitivity, which resulted in compulsory atrial stimulation followed by biventricular pacing. The CCM system recognized the atrial stimuli as p waves, which led to CCM signal delivery. Three patients developed permanent AF after a mean follow-up of 40 months of CCM therapy. Two patients had permanent AF at the time of CCM device implantation. All pacemaker or ICD devices were successfully upgraded to CRT. Cardiac resynchronization therapy stimulation rates of ≥96% and CCM stimulation rates between 60% and 95% were achieved. Clinical condition of the patients improved (mean NYHA class −0.7, left ventricular ejection fraction +2%, Minnesota living with HF questionnaire −15.6 points). CCM signal delivery is feasible in HF patients with permanent AF by sequential atrial-ventricular pacing, so that the atrial pacing spike is interpreted as a p wave by the CCM signal delivery algorithm. This experimental approach can be considered in individual cases. A new CCM algorithm, which does not require an atrial electrode, is desirable.