RJReva E. Johnson

Reva E. Johnson

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Reva E. Johnson has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • WIP: Design and Assessment of a Centralized Website to Promote Undergraduate Research

    by Madeleine Fahey, Trinity Lee, Jean Huang, Jeff Dusek, Reva Johnson, Daniel Maguire

  • WIP: Building Intuition in Mechanics with Haptic Feedback

    by Pichayathida (Alice) Luanpaisanon, Carter Kenneth McCullough, Ryan Van Der Zee, Ruth Wertz, Reva E. Johnson

  • “Nothing about us without us:” engaging at users in at research

    by Alicia Koontz, Jonathan Duvall, Reva Johnson, Tim Reissman, Emma Smith

    The powerful slogan “nothing about us without us” has been a motto of the disability rights movement for decades – and still remains a powerful reminder of the work we have yet to do. While assisti...


  • Open Access

    Joint Speed Discrimination and Augmentation For Prosthesis Feedback

    by Eric J. Earley, Reva E. Johnson, Levi J. Hargrove, Jon W. Sensinger

    Sensory feedback is critical in fine motor control, learning, and adaptation. However, robotic prosthetic limbs currently lack the feedback segment of the communication loop between user and device. Sensory substitution feedback can close this gap, but sometimes this improvement only persists when users cannot see their prosthesis, suggesting the provided feedback is redundant with vision. Thus, given the choice, users rely on vision over artificial feedback. To effectively augment vision, sensory feedback must provide information that vision cannot provide or provides poorly. Although vision is known to be less precise at estimating speed than position, no work has compared speed precision of biomimetic arm movements. In this study, we investigated the uncertainty of visual speed estimates as defined by different virtual arm movements. We found that uncertainty was greatest for visual estimates of joint speeds, compared to absolute rotational or linear endpoint speeds. Furthermore, this uncertainty increased when the joint reference frame speed varied over time, potentially caused by an overestimation of joint speed. Finally, we demonstrate a joint-based sensory substitution feedback paradigm capable of significantly reducing joint speed uncertainty when paired with vision. Ultimately, this work may lead to improved prosthesis control and capacity for motor learning.


  • Open Access

    Joint Speed Discrimination and Augmentation For Prosthesis Feedback

    by Eric J. Earley, Reva E. Johnson, Levi J. Hargrove, Jon W. Sensinger

    Sensory feedback is critical in fine motor control, learning, and adaptation. However, robotic prosthetic limbs currently lack the feedback segment of the communication loop between user and device. Artificial sensory feedback can close this gap, but sometimes this improvement only persists when users cannot see their prosthesis. suggesting the provided feedback is redundant with vision. Thus, given the choice, users rely on vision over artificial feedback. To effectively augment vision, sensory feedback must provide information that vision cannot provide or provides poorly. Although vision is known to be less precise at estimating speed than position, no work has compared speed precision of biomimetic arm movements. In this study, we investigated the uncertainty of visual speed estimates as defined by different virtual arm movements. We found that uncertainty was greatest for visual estimates of joint speeds, compared to absolute or linear endpoint speeds. Furthermore, this uncertainty increased when the joint reference frame speed varied over time, potentially caused by an overestimation of joint speed. Finally, we demonstrate a joint-based sensory feedback paradigm capable of significantly reducing joint speed uncertainty when paired with vision. Ultimately, this work may lead to improved prosthesis control and capacity for motor learning.


  • Open Access

    Adaptation to random and systematic errors: Comparison of amputee and non-amputee control interfaces with varying levels of process noise

    by Reva E. Johnson, Konrad P. Kording, Levi J. Hargrove, Jonathon W. Sensinger

    The objective of this study was to understand how people adapt to errors when using a myoelectric control interface. We compared adaptation across 1) non-amputee subjects using joint angle, joint torque, and myoelectric control interfaces, and 2) amputee subjects using myoelectric control interfaces with residual and intact limbs (five total control interface conditions). We measured trial-by-trial adaptation to self-generated errors and random perturbations during a virtual, single degree-of-freedom task with two levels of feedback uncertainty, and evaluated adaptation by fitting a hierarchical Kalman filter model. We have two main results. First, adaptation to random perturbations was similar across all control interfaces, whereas adaptation to self-generated errors differed. These patterns matched predictions of our model, which was fit to each control interface by changing the process noise parameter that represented system variability. Second, in amputee subjects, we found similar adaptation rates and error levels between residual and intact limbs. These results link prosthesis control to broader areas of motor learning and adaptation and provide a useful model of adaptation with myoelectric control. The model of adaptation will help us understand and solve prosthesis control challenges, such as providing additional sensory feedback.


  • Open Access

    EMG Versus Torque Control of Human–Machine Systems: Equalizing Control Signal Variability Does not Equalize Error or Uncertainty

    by Reva E. Johnson, Konrad P. Kording, Levi J. Hargrove, Jonathon W. Sensinger

    In this paper we asked the question: if we artificially raise the variability of torque control signals to match that of EMG, do subjects make similar errors and have similar uncertainty about their movements? We answered this question using two experiments in which subjects used three different control signals: torque, torque+noise, and EMG. First, we measured error on a simple target-hitting task in which subjects received visual feedback only at the end of their movements. We found that even when the signal-to-noise ratio was equal across EMG and torque+noise control signals, EMG resulted in larger errors. Second, we quantified uncertainty by measuring the just-noticeable difference of a visual perturbation. We found that for equal errors, EMG resulted in higher movement uncertainty than both torque and torque+noise. The differences suggest that performance and confidence are influenced by more than just the noisiness of the control signal, and suggest that other factors, such as the user's ability to incorporate feedback and develop accurate internal models, also have significant impacts on the performance and confidence of a person's actions. We theorize that users have difficulty distinguishing between random and systematic errors for EMG control, and future work should examine in more detail the types of errors made with EMG control.