Shuang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shuang Liu has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Jun Yang
Department of Cardiovascular Ultrasound, The First Hospital of China Medical University, Shenyang, Liaoning, People's Republic of China
2 shared publicationsRaed Aladham
Department of Cardiovascular Disease, Echocardiography Division Mayo Clinic Scottsdale Arizona USA
2 shared publications- Tasneem Z. Naqvi
Division of Echocardiography, Department of Cardiovascular Medicine, Mayo Clinic, Phoenix, AZ
2 shared publications Chunyan Ma
Department of Cardiovascular Ultrasound, The First Hospital of China Medical University, Shenyang, Liaoning, People's Republic of China
1 shared publication- Chunyan Ma
Department of Cardiovascular Ultrasound The First Hospital of China Medical University Shenyang China
1 shared publication Jing An
Department of Ultrasound, Second Affiliated Hospital of Liaoning University of Traditional Chinese Medicine, Shenyang, 110034, People's Republic of China
1 shared publication
Latest Publications
- 7 May 2023
- Published by Wiley in Echocardiography
- Vol. 40 (6) , 475-482
Impact of physician performed point of care ultrasound (POCUS) during first outpatient cardiology consultation on patient management and downstream testing
Background: Goal directed point of care ultrasound (POCUS) is a bedside tool to assist with clinical diagnosis. We examined the impact of POCUS performed by consulting cardiologist (CC) during initial cardiology consult on clinical management and downstream testing.Methods: Sixty‐nine study patients (pts) seen in a general cardiology outpatient clinic of a tertiary center by an expert imaging CC were compared to a control group of 65 pts seen by three different CCs without POCUS during the same time‐period, in whom the first standard echo (SE) was performed after the initial visit.Results: Baseline characteristics were similar between the two groups for age, cardiac risk factors, and referral diagnoses. Echo findings on POCUS and by SE (mean delay of 17.2 days after visit) in the control group were comparable for RV size and function and for valvular heart disease. More patients with lower LVEF, higher LV filling pressures, new regional wall motion abnormalities, and increased aortic root size were present among POCUS group resulting in greater yield of echo abnormalities. There were more cardiovascular medication changes at the first visit (15.3% vs. 5.7%, p < .01), less referral for noninvasive stress testing (10% vs. 29%, p < .01), more advanced cardiac testing and subspecialty referrals (29% vs. 18% pts, p = .06), in the study compared to the control group after cardiology visit.Conclusion: POCUS at time of consultation detects more abnormal echo findings, results in more medication adjustments, less referral for noninvasive stress testing, earlier referral for advanced cardiac diagnostic imaging, and subspecialty cardiac referrals.
- 7 May 2023
- Published by Wiley in Echocardiography
- Vol. 40 (6) , 475-482
Impact of physician performed point of care ultrasound (POCUS) during first outpatient cardiology consultation on patient management and downstream testing
Background: Goal directed point of care ultrasound (POCUS) is a bedside tool to assist with clinical diagnosis. We examined the impact of POCUS performed by consulting cardiologist (CC) during initial cardiology consult on clinical management and downstream testing.Methods: Sixty‐nine study patients (pts) seen in a general cardiology outpatient clinic of a tertiary center by an expert imaging CC were compared to a control group of 65 pts seen by three different CCs without POCUS during the same time‐period, in whom the first standard echo (SE) was performed after the initial visit.Results: Baseline characteristics were similar between the two groups for age, cardiac risk factors, and referral diagnoses. Echo findings on POCUS and by SE (mean delay of 17.2 days after visit) in the control group were comparable for RV size and function and for valvular heart disease. More patients with lower LVEF, higher LV filling pressures, new regional wall motion abnormalities, and increased aortic root size were present among POCUS group resulting in greater yield of echo abnormalities. There were more cardiovascular medication changes at the first visit (15.3% vs. 5.7%, p < .01), less referral for noninvasive stress testing (10% vs. 29%, p < .01), more advanced cardiac testing and subspecialty referrals (29% vs. 18% pts, p = .06), in the study compared to the control group after cardiology visit.Conclusion: POCUS at time of consultation detects more abnormal echo findings, results in more medication adjustments, less referral for noninvasive stress testing, earlier referral for advanced cardiac diagnostic imaging, and subspecialty cardiac referrals.
- Open Access
- 13 January 2023
- Published by Wiley
Impact of Physician Performed Point of Care Ultrasound (POCUS) During first Outpatient Cardiology Consultation on Patient Management and Downstream Testing
A document by Tasneem Naqvi. Click on the document to view its contents.
- 13 January 2023
- Published by Wiley
Open AccessImpact of Physician Performed Point of Care Ultrasound (POCUS) During first Outpatient Cardiology Consultation on Patient Management and Downstream Testing
A document by Tasneem Naqvi. Click on the document to view its contents.
- 24 July 2019
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 35 (12) , 2205-2212
Subclinical left ventricular dysfunction assessed by two-dimensional speckle tracking echocardiography in asymptomatic patients with carotid stenosis
The relationship between subclinical left ventricular (LV) dysfunction and atherosclerosis may have been underestimated in the past, which might be responsible for the high incidence of premature death in individuals with carotid stenosis. We sought to evaluate the underlying myocardial dysfunction in asymptomatic carotid stenosis patients using speckle tracking echocardiography (STE). Fifty patients with carotid stenosis ≥ 50% and a preserved LV ejection fraction (LVEF), and 45 controls without carotid stenosis who were matched in terms of vascular comorbidities were enrolled. All participants underwent carotid ultrasound and echocardiographic examination. The global LV longitudinal strain (GLS) was measured using STE. Compared with the control group, the e’ of the mitral annular velocity and GLS were decreased in asymptomatic carotid stenosis patients (p < 0.05), however, the LVEF was well preserved. Based on a predefined cutoff for subclinical LV systolic dysfunction that was defined at a GLS < − 18%, this dysfunction was detected in 22 patients with carotid stenosis (44%) and in 10 patients in the control group (22%) (p < 0.05). The GLS was negatively correlated with the levels of low-density lipoprotein cholesterol (r = − 0.356, p < 0.05) and triglyceride (r = − 0.396, p < 0.05). In conclusion, LV diastolic and systolic functioning were significantly decreased in patients with asymptomatic carotid stenosis, and dyslipidemia likely contributed to the subclinical LV dysfunction in these patients. Our findings indicated the importance of detecting LV subclinical dysfunction and early intervention in this patient population.
- 24 July 2019
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 35 (12) , 2205-2212
Subclinical left ventricular dysfunction assessed by two-dimensional speckle tracking echocardiography in asymptomatic patients with carotid stenosis
The relationship between subclinical left ventricular (LV) dysfunction and atherosclerosis may have been underestimated in the past, which might be responsible for the high incidence of premature death in individuals with carotid stenosis. We sought to evaluate the underlying myocardial dysfunction in asymptomatic carotid stenosis patients using speckle tracking echocardiography (STE). Fifty patients with carotid stenosis ≥ 50% and a preserved LV ejection fraction (LVEF), and 45 controls without carotid stenosis who were matched in terms of vascular comorbidities were enrolled. All participants underwent carotid ultrasound and echocardiographic examination. The global LV longitudinal strain (GLS) was measured using STE. Compared with the control group, the e’ of the mitral annular velocity and GLS were decreased in asymptomatic carotid stenosis patients (p < 0.05), however, the LVEF was well preserved. Based on a predefined cutoff for subclinical LV systolic dysfunction that was defined at a GLS < − 18%, this dysfunction was detected in 22 patients with carotid stenosis (44%) and in 10 patients in the control group (22%) (p < 0.05). The GLS was negatively correlated with the levels of low-density lipoprotein cholesterol (r = − 0.356, p < 0.05) and triglyceride (r = − 0.396, p < 0.05). In conclusion, LV diastolic and systolic functioning were significantly decreased in patients with asymptomatic carotid stenosis, and dyslipidemia likely contributed to the subclinical LV dysfunction in these patients. Our findings indicated the importance of detecting LV subclinical dysfunction and early intervention in this patient population.
- 30 March 2018
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 37 (11) , 2637-2645
Incremental Value of the Tissue Motion of Annular Displacement Derived From Speckle‐Tracking Echocardiography for Differentiating Chronic Constrictive Pericarditis From Restrictive Cardiomyopathy
Objectives: The tissue motion of annular displacement provides an accurate and rapid assessment of left ventricular (LV) systolic function. However, it has rarely been used in patients with chronic constrictive pericarditis and restrictive cardiomyopathy. This study aimed to assess the differences in LV systolic function in patients with constrictive pericarditis and restrictive cardiomyopathy using tissue motion of annular displacement derived from speckle‐tracking echocardiography.Methods: Twenty‐four patients with constrictive pericarditis, 24 with restrictive cardiomyopathy, and 25 healthy volunteers (controls) were enrolled. The septal and lateral mitral annular longitudinal displacements, displacement at the midpoint, and normalized midpoint displacement of the mitral ring were calculated.Results: Mitral annular tracking and quantification of the tissue motion of annular displacement were achieved within 10 seconds. In patients with constrictive pericarditis, the lateral mitral annular longitudinal displacement, displacement at the midpoint, and midpoint displacement of the mitral ring were decreased, whereas the septal mitral annular longitudinal displacement was preserved compared to controls, indicating that the reduction of systolic function in constrictive pericarditis was caused by pericardial adhesion and calcium. In patients with restrictive cardiomyopathy, tissue motion of annular displacement was more reduced compared to patients with constrictive pericarditis and controls. The correlation between the septal mitral annular longitudinal displacement and left ventricular ejection fraction was 0.67 (P < .001). A cutoff value of 8.45 mm for the septal mitral annular longitudinal displacement could effectively differentiate constrictive pericarditis from restrictive cardiomyopathy with 95.2% sensitivity and 91.7% specificity.Conclusions: The tissue motion of annular displacement was decreased in patients with constrictive pericarditis, which indicated early impairment of longitudinal function in constrictive pericarditis; adhesion and calcium in the pericardium might account for the reduction. The septal mitral annular longitudinal displacement provides a fast and effective method for the assessment of LV systolic function in patients with constrictive pericarditis and restrictive cardiomyopathy.
- 30 March 2018
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 37 (11) , 2637-2645
Incremental Value of the Tissue Motion of Annular Displacement Derived From Speckle‐Tracking Echocardiography for Differentiating Chronic Constrictive Pericarditis From Restrictive Cardiomyopathy
Objectives: The tissue motion of annular displacement provides an accurate and rapid assessment of left ventricular (LV) systolic function. However, it has rarely been used in patients with chronic constrictive pericarditis and restrictive cardiomyopathy. This study aimed to assess the differences in LV systolic function in patients with constrictive pericarditis and restrictive cardiomyopathy using tissue motion of annular displacement derived from speckle‐tracking echocardiography.Methods: Twenty‐four patients with constrictive pericarditis, 24 with restrictive cardiomyopathy, and 25 healthy volunteers (controls) were enrolled. The septal and lateral mitral annular longitudinal displacements, displacement at the midpoint, and normalized midpoint displacement of the mitral ring were calculated.Results: Mitral annular tracking and quantification of the tissue motion of annular displacement were achieved within 10 seconds. In patients with constrictive pericarditis, the lateral mitral annular longitudinal displacement, displacement at the midpoint, and midpoint displacement of the mitral ring were decreased, whereas the septal mitral annular longitudinal displacement was preserved compared to controls, indicating that the reduction of systolic function in constrictive pericarditis was caused by pericardial adhesion and calcium. In patients with restrictive cardiomyopathy, tissue motion of annular displacement was more reduced compared to patients with constrictive pericarditis and controls. The correlation between the septal mitral annular longitudinal displacement and left ventricular ejection fraction was 0.67 (P < .001). A cutoff value of 8.45 mm for the septal mitral annular longitudinal displacement could effectively differentiate constrictive pericarditis from restrictive cardiomyopathy with 95.2% sensitivity and 91.7% specificity.Conclusions: The tissue motion of annular displacement was decreased in patients with constrictive pericarditis, which indicated early impairment of longitudinal function in constrictive pericarditis; adhesion and calcium in the pericardium might account for the reduction. The septal mitral annular longitudinal displacement provides a fast and effective method for the assessment of LV systolic function in patients with constrictive pericarditis and restrictive cardiomyopathy.