BMBirgit Meng

Birgit Meng

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years

Research Subjects


Birgit Meng has a total of 87 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Baustoffe im Betonbau

    by Christoph Gehlen, Thomas Kränkel, Birgit Meng, Kai Osterminski, Falk Meyer, Petra Schröder

  • Effect of gypsum on the hydration of fused cement clinker from basic oxygen furnace slag

    by Katharina Schraut, Burkart Adamczyk, Christian Adam, Dietmar Stephan, Birgit Meng, Sebastian Simon, Julia von Werder, Tamino Hirsch, Tanja Manninger

    Fused cement clinker can be produced from molten basic oxygen furnace slag (BOFS) by way of a reductive thermochemical treatment. During the thermochemical treatment, oxidic iron is reduced to metallic iron and separated. The resulting low-iron slag has a chemical and mineralogical composition similar to ordinary Portland cement (OPC) clinker. In this study, the hydraulic reactivity of the fused clinker from BOFS with and without gypsum was investigated using isothermal calorimetry, differential scanning calorimetry, in situ X-ray diffraction and powder X-ray diffraction. Furthermore, a synthetic fused clinker without foreign ions and fused clinker produced by a mixture of both materials was studied. The hydraulic reaction of the fused clinker from BOFS was considerably slower than that of OPC. However, the reaction can be accelerated by adding gypsum as a sulfate carrier. Furthermore, the results showed an increased reaction rate with decreasing content of foreign ions such as Fe, P or Mn.


  • Open Access

    Thermal and hydrothermal treatment of UHPC: influence of the process parameters on the phase composition of ultra-high performance concrete

    by Julia von Werder, Sebastian Simon, André Gardei, Patrick Fontana, Birgit Meng

    Several studies show that thermal and hydrothermal treatment can further improve the excellent properties of UHPC in terms of mechanical strength and durability. While for the thermal treatment the increase in strength is attributed to an intensified pozzolanic and hydraulic reaction, for the hydrothermal treatment previous studies accredited it mostly to the formation of tobermorite. In the presented study thermal and hydrothermal treatment of UHPC samples was systematically varied and the phase formation analysed related to the strength development of a reference sample cured for 28 days in water. For the thermal treatment the results show that the strength increase depends on the protection against desiccation and can be ascribed to an improved pozzolanic reaction of the siliceous fillers. To achieve a significant enhancement of strength, a pre-storage time of few days and a long dwell time at elevated temperature/pressure are required. For the hydrothermal treatment already heating the specimens up to 185 °C in saturated steam followed by an immediate cooling leads to a substantial increase in compressive strength. Pre-storage time did not affect the result as far as a minimum of several hours is guaranteed. The improved performance is due to an increase in the pozzolanic and hydraulic reaction. Surprisingly, tobermorite was only found within a very thin layer at the surface of the sample, but not in the bulk. Sulphate and aluminium stemming from the decomposition of the ettringite are bound in the newly formed phases hydroxylellestadite and hydrogarnet.


  • Automatisierte AKR‐Prüfung im 60 °C‐Betonversuch

    by Enno Krütt, Wilma Wallau, Birgit Meng, Markus Greim, Stephan Pirskawetz

    Der 60 °C‐Betonversuch ist eine in Deutschland und international verbreitete Methode, um die Empfindlichkeit von Gesteinskörnungen und Betonen hinsichtlich einer Alkali‐Kieselsäure‐Reaktion (AKR) zu prüfen. Dieser Beitrag stellt eine neu entwickelte, automatisierte Variante der Prüfmethode in einem Minireaktor vor. Dabei werden die Dehnungen von Betonprismen nicht wie beim konventionellen Test manuell, sondern automatisch in entsprechend ausgerüsteten Prüfbehältern gemessen. Neben einer Reduzierung des Messaufwands bringt die automatisierte Prüfung im Minireaktor weitere Vorteile. Die Dehnungssignale werden, anders als bei der konventionellen Messung, quasi kontinuierlich aufgezeichnet und bilden das Expansionsverhalten der Prismen detailliert ab. Außerdem bleiben Unterbrechungen der AKR‐provozierenden Lagerung aus, die bei der konventionellen Prüfung notwendig sind. Im Beitrag werden die automatisierte und konventionelle Prüfung anhand der Dehnungen von Prismen zweier Gesteinskörnungen verglichen. In Übereinstimmung mit vorhergehenden Untersuchungen sind im Minireaktor gemessene Dehnungen systematisch kleiner als manuell gemessene. Als mögliche Ursache werden Unterschiede im Auslaugverhalten experimentell untersucht. Zur Überprüfung der Einstufung der zwei Gesteinskörnungen erfolgen außerdem Referenzprüfungen in der Nebelkammerlagerung bei 40 °C.


  • UHPC–AAC facade elements: Structural design, production technology, and mechanical behavior

    by Lorenzo Miccoli, Patrick Fontana, Dirk Qvaeschning, Oliver Kreft, Johannes Hoppe, Birgit Meng

    The aim of this study was to develop a lightweight composite facade element for new buildings and for the refurbishment of existing facades. These composite elements have been developed combining an insulation layer of autoclaved aerated concrete (AAC) with an external ultrahigh‐performance concrete (UHPC) supporting layer. This solution allows avoiding the use of connectors and facilitates the production procedure. The structural behavior of the facade elements is mainly influenced by the presence of the upturning edges that are able to increase the stiffness of the element and reduce the thickness of the external layer. The insulation material has no influence on the structural behavior of the UHPC boxes. Flexural tests were carried out to investigate a potential detachment of the external layer from the upturning edge. The photogrammetric analysis used during the flexural tests essentially confirmed that the bond between the two UHPC layers cast in two steps is reliable. The quality of the bond between the external layer and the upturning edge is a key parameter to define the bearing capacity of the element.


  • Autoclaving of ultra‐high performance concrete (UHPC)

    by Julia von Werder, Sebastian Simon, Christian Lehmann, Christian Selleng, Patrick Fontana, Birgit Meng

    By the combination of an optimized granulometry, a reduced water–cement ratio and the use of superplasticizers ultra‐high performance concrete achieves a compressive strength of over 150 N/mm2 and a high resistance regarding acids and water‐soluble salts. In different research projects the effect of an autoclavation on the mechanical strength and the phase composition was analyzed. In systematic studies, the concrete mix and the process parameters were varied. The results show that autoclavation leads to an improved pozzolanic and hydraulic reaction and significantly improves the mechanical strength compared to a conventional thermal treatment. If a minimum time‐span for hydration is ensured, the achievable strength level is not dependent on the prestorage time. However, the duration of the autoclaving is significant. After the maximum strength is reached there is only a very slight decrease, even if unrealistically long autoclaving times are applied.


  • Prompt Phase Analyses of Ultrahigh-Performance Concrete

    by Sebastian Simon, Christian Selleng, Birgit Meng

    Powder X-ray diffraction is a time-consuming and challenging task, especially for preparation of sensitive phases like ettringite and calcium-silicate-hydrate (C-S-H) phases. Fine-grained ultrahigh-performance concrete (UHPC) with an average grain size <100  μm could be investigated directly without time-consuming milling. As a proof of concept, small UHPC cylinders with plain surfaces were investigated with a newly designed sample holder. The comparison with conventionally prepared powder shows the feasibility of fast qualitative phase analysis using this approach. As a great benefit, a depth-dependent analysis, as well as a comparison of surface layers and core material, was carried out.


  • Effects of fatigue loading and alkali–silica reaction on the mechanical behavior of pavement concrete

    by Andreas Wiedmann, Frank Weise, Engin Kotan, Harald S. Müller, Birgit Meng

    The primary aim of this paper is to analyze the impact of mechanical pre‐damage and alkali–silica reaction (ASR) on the fracture mechanical properties of pavement concrete. For this purpose, a four point bending test was applied to large format beams to produce a defined level of cyclic pre‐damage. The fatigue‐induced concrete degradation process was simultaneously recorded using a testing procedure specifically developed for the purpose. In addition, fatigue‐induced cracks on extracted drilling cores were spatially visualized and quantified using micro X‐ray 3D‐computed tomography (3D‐CT). The storage of the small‐format test specimens, with and without cyclic pre‐damage, in an ASR‐conducive environment showed that pre‐damage leads to an increase in ASR damage processes. Subsequent structural mechanical investigations on small format specimens with and without pre‐damage show that fatigue loading and ASR significantly influence fracture mechanical parameters of the concrete.