Sirinart Chomean
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sirinart Chomean has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Chollanot Kaset
Department of Medical Technology, Faculty of Allied Health Sciences, Thammasat University, Pathum Thani, Thailand
11 shared publications - Chamras Promptmas
Department of Biomedical Engineering, Faculty of Engineering, Mahidol University, Nakhon Pathom, Thailand
3 shared publications - Anek Pootong
Department of Medical Technology, Faculty of Allied Health Sciences, Thammasat University, Pathum Thani, Thailand
2 shared publications Areenuch Thamwarokun
2 shared publicationsChollanot Kaset
Department of Medical Technology, Faculty of Allied Health Sciences, Thammasat University, Pathumthani, Thailand
2 shared publicationsJirapat Attapong
Graduate Program in Biomedical Sciences, Faculty of Allied Health Sciences, Thammasat University, Pathumthani, Thailand
2 shared publications
Latest Publications
- Open Access
- 1 September 2026
- Published by Faculty of Associated Medical Sciences, Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 60 (1) , 31-43
Machine learning with SMOTE-NC on routine hematology parameters for early identification of Hb E trait
Background: The hemoglobin E (Hb E) trait, which is highly prevalent in Southeast Asia and may co-occur with α-thalassemia, often exhibits heterogeneous complete blood count profiles; notably, some individuals with the Hb E trait have near-normal MCV and MCH values, increasing the risk of misclassification during routine hematological screening. Objective: This study aimed to develop and externally validate an interpretable machine-learning model to screen for Hb E trait using routine Complete Blood Count (CBC) data. Materials and methods: We analyzed 5,787 standardized CBC records using two processing pipelines: a standard dataset and an SMOTE-NC oversampled dataset. We selected features using ReliefF and evaluated nine machinelearning algorithms. We interpreted the optimal model using SHAP values and validated it on an independent external cohort (n=625). Results: Discrimination for Hb E trait was moderate-to-good and consistent between internal and external evaluation. Erythrocyte indices-Z-MCV, Z-MCH, and Z-RBC-were the most discriminative features. Among nine algorithms, a support vector machine gave the best combination of sensitivity and discrimination (internal AUC 0.881, sensitivity 70.66%, specificity 87.92%; external AUC 0.879, sensitivity 72.38%, specificity 87.39%). With the decision threshold tuned for screening, external sensitivity rose to approximately 91% with negative predictive value above 94%. SHAP analysis confirmed the model’s reliance on biologically plausible drivers (low MCV/MCH with a relatively preserved RBC count). Conclusion: An explainable machine-learning model utilizing routine CBC parameters offers a viable, low-cost pre-screening tool for Hb E trait. Internal and external performance are concordant, and with local calibration and threshold tuning, the model triages patients for confirmatory testing and definitive genotyping rather than replacing them, supporting optimized diagnostic workflows in endemic regions.
- 1 September 2026
- Published by Faculty of Associated Medical Sciences, Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 60 (1) , 31-43
Open AccessMachine learning with SMOTE-NC on routine hematology parameters for early identification of Hb E trait
Background: The hemoglobin E (Hb E) trait, which is highly prevalent in Southeast Asia and may co-occur with α-thalassemia, often exhibits heterogeneous complete blood count profiles; notably, some individuals with the Hb E trait have near-normal MCV and MCH values, increasing the risk of misclassification during routine hematological screening. Objective: This study aimed to develop and externally validate an interpretable machine-learning model to screen for Hb E trait using routine Complete Blood Count (CBC) data. Materials and methods: We analyzed 5,787 standardized CBC records using two processing pipelines: a standard dataset and an SMOTE-NC oversampled dataset. We selected features using ReliefF and evaluated nine machinelearning algorithms. We interpreted the optimal model using SHAP values and validated it on an independent external cohort (n=625). Results: Discrimination for Hb E trait was moderate-to-good and consistent between internal and external evaluation. Erythrocyte indices-Z-MCV, Z-MCH, and Z-RBC-were the most discriminative features. Among nine algorithms, a support vector machine gave the best combination of sensitivity and discrimination (internal AUC 0.881, sensitivity 70.66%, specificity 87.92%; external AUC 0.879, sensitivity 72.38%, specificity 87.39%). With the decision threshold tuned for screening, external sensitivity rose to approximately 91% with negative predictive value above 94%. SHAP analysis confirmed the model’s reliance on biologically plausible drivers (low MCV/MCH with a relatively preserved RBC count). Conclusion: An explainable machine-learning model utilizing routine CBC parameters offers a viable, low-cost pre-screening tool for Hb E trait. Internal and external performance are concordant, and with local calibration and threshold tuning, the model triages patients for confirmatory testing and definitive genotyping rather than replacing them, supporting optimized diagnostic workflows in endemic regions.
- 2 May 2026
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 59 (2) , 97-104
Association of Intron 22 inversion and HLA-DRB1*15:01 allele with inhibitor development in hemophilia A: A genetic analysis of risk factors
Background: Inhibitor development in hemophilia A is a major clinical challenge, leading to severe bleeding complications and reduced quality of life. This multifactorial process is influenced by genetic, immunological, and treatmentrelated factors. Objectives: To determine the association between intron 22 inversion (Inv22) and the HLA-DRB1*15:01 allele with inhibitor development. Materials and methods: This study investigated inhibitor development during initial and subsequent treatments, assessing the association between Inv22 and HLA-DRB1*15:01 with inhibitor formation in 40 hemophilia A patients, 40 non-hemophilia A patients, and 40 healthy controls. Results: The study found no significant association between Inv22 or HLADRB1*15:01 allele and inhibitor development during initial (odds ratio (OR): 0.60, 95% CI: 0.11-3.43, p=0.697) or subsequent treatments (OR: 1.33, 95% CI: 0.30-5.93, p=1.000). Similarly, HLA-DRB1*15:01 allele showed no significant correlation (initial: OR: 0.25, 95% CI: 0.06-1.13, p=0.089; subsequent: OR: 0.82, 95% CI: 0.24-2.84, p=1.000). However, patients with both genetic factors had a significantly higher risk of developing inhibitors (OR: 7.90, 95% CI: 1.88-33.06, p=0.007). Conclusion: This study found no significant association between Inv22 or the HLA-DRB1*15:01 allele and inhibitor development in hemophilia A patients during initial or subsequent treatments. However, their combined presence significantly increased the risk of inhibitor formation, suggesting a potential interactive effect requiring further investigation.
- 2 May 2026
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 59 (2) , 97-104
Association of Intron 22 inversion and HLA-DRB1*15:01 allele with inhibitor development in hemophilia A: A genetic analysis of risk factors
Background: Inhibitor development in hemophilia A is a major clinical challenge, leading to severe bleeding complications and reduced quality of life. This multifactorial process is influenced by genetic, immunological, and treatmentrelated factors. Objectives: To determine the association between intron 22 inversion (Inv22) and the HLA-DRB1*15:01 allele with inhibitor development. Materials and methods: This study investigated inhibitor development during initial and subsequent treatments, assessing the association between Inv22 and HLA-DRB1*15:01 with inhibitor formation in 40 hemophilia A patients, 40 non-hemophilia A patients, and 40 healthy controls. Results: The study found no significant association between Inv22 or HLADRB1*15:01 allele and inhibitor development during initial (odds ratio (OR): 0.60, 95% CI: 0.11-3.43, p=0.697) or subsequent treatments (OR: 1.33, 95% CI: 0.30-5.93, p=1.000). Similarly, HLA-DRB1*15:01 allele showed no significant correlation (initial: OR: 0.25, 95% CI: 0.06-1.13, p=0.089; subsequent: OR: 0.82, 95% CI: 0.24-2.84, p=1.000). However, patients with both genetic factors had a significantly higher risk of developing inhibitors (OR: 7.90, 95% CI: 1.88-33.06, p=0.007). Conclusion: This study found no significant association between Inv22 or the HLA-DRB1*15:01 allele and inhibitor development in hemophilia A patients during initial or subsequent treatments. However, their combined presence significantly increased the risk of inhibitor formation, suggesting a potential interactive effect requiring further investigation.
- 2 May 2025
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 58 (2) , 290-296
Assessment of colistin resistance in Enterobacteriaceae: Comparison of the rapid polymyxin NP test, MicroScan system, and broth microdilution in Thailand
Background: Antimicrobial resistance is a global health crisis, with colistin serving as a last-resort antibiotic for the treatment of multidrug-resistant Enterobacteriaceae. However, colistin resistance is becoming increasingly prevalent, necessitating rapid and accurate susceptibility testing. Objective: This study evaluated the rapid polymyxin NP (RPNP) test and the MicroScan antimicrobial susceptibility system compared to the reference broth microdilution (rBMD) method for detecting colistin resistance in colistin-resistant Enterobacteriaceae (CRE) isolates from clinical setting in Thailand. Materials and methods: A total of 158 non-repetitive Enterobacteriaceae isolates (85 Escherichia coli and 73 Klebsiella pneumoniae) were collected from a tertiary hospital in Bangkok between August 2021 and January 2023. Colistin susceptibility was assessed using the RPNP, MicroScan system, and rBMD method following the Clinical and Laboratory Standards Institute (CLSI) guidelines. The categorical agreement (CA), very major errors (VME), and major errors (ME) of colistin resistance test results from the RPNP and MicroScan methods were determined by comparison with the rBMD method. Results: Among the 158 Enterobacteriaceae isolates, 46.2% were intermediate and 38.6% were colistin-resistant by rBMD. The sensitivity of RPNP was 98.4% and the specificity was 95.9%, compared to 95.1% and 97.9% for MicroScan. Both RPNP and MicroScan achieved high CA (96.8%) with rBMD. Discrepancies, primarily in isolates with borderline MICs (1-4 mg/L), accounted for 4 of the 8 discordant strains. In addition, mobilized colistin resistance-1 (mcr-1) gene were detected in 5 colistin-resistant E. coli isolates with MIC of 8 mg/L. Conclusion: Both the RPNP and MicroScan systems demonstrated high categorical agreement with the rBMD method, underscoring their reliability as practical tools for routine colistin susceptibility testing in clinical microbiology laboratories where rBMD may not be feasible.
- 2 May 2025
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 58 (2) , 290-296
Assessment of colistin resistance in Enterobacteriaceae: Comparison of the rapid polymyxin NP test, MicroScan system, and broth microdilution in Thailand
Background: Antimicrobial resistance is a global health crisis, with colistin serving as a last-resort antibiotic for the treatment of multidrug-resistant Enterobacteriaceae. However, colistin resistance is becoming increasingly prevalent, necessitating rapid and accurate susceptibility testing. Objective: This study evaluated the rapid polymyxin NP (RPNP) test and the MicroScan antimicrobial susceptibility system compared to the reference broth microdilution (rBMD) method for detecting colistin resistance in colistin-resistant Enterobacteriaceae (CRE) isolates from clinical setting in Thailand. Materials and methods: A total of 158 non-repetitive Enterobacteriaceae isolates (85 Escherichia coli and 73 Klebsiella pneumoniae) were collected from a tertiary hospital in Bangkok between August 2021 and January 2023. Colistin susceptibility was assessed using the RPNP, MicroScan system, and rBMD method following the Clinical and Laboratory Standards Institute (CLSI) guidelines. The categorical agreement (CA), very major errors (VME), and major errors (ME) of colistin resistance test results from the RPNP and MicroScan methods were determined by comparison with the rBMD method. Results: Among the 158 Enterobacteriaceae isolates, 46.2% were intermediate and 38.6% were colistin-resistant by rBMD. The sensitivity of RPNP was 98.4% and the specificity was 95.9%, compared to 95.1% and 97.9% for MicroScan. Both RPNP and MicroScan achieved high CA (96.8%) with rBMD. Discrepancies, primarily in isolates with borderline MICs (1-4 mg/L), accounted for 4 of the 8 discordant strains. In addition, mobilized colistin resistance-1 (mcr-1) gene were detected in 5 colistin-resistant E. coli isolates with MIC of 8 mg/L. Conclusion: Both the RPNP and MicroScan systems demonstrated high categorical agreement with the rBMD method, underscoring their reliability as practical tools for routine colistin susceptibility testing in clinical microbiology laboratories where rBMD may not be feasible.
- Open Access
- 29 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (19) , 2177
Comparative Analysis of HPV Detection Efficiency: Evaluating Cobas 8800 Performance in Vaginal Self-Sampling versus Clinician-Collected Samples at a Regional Thai Hospital
Background: This study, conducted at a regional Thai hospital, assesses the comparative efficacy of self-collected versus clinician-collected samples for HPV detection using the Cobas 8800 system among Thai women aged 30–60. Methods: Our methodology involved analyzing 1541 self-collected and 1398 clinician-collected samples. Results: The results show a statistically significant mean difference in cycle threshold (Ct) values favoring clinician-collected samples (1.53; 95% CI: 1.18–1.87, p < 0.0001). This pattern was consistent across various age groups, with the most pronounced differences noted in the oldest cohort (50–59 years), suggesting higher detection efficiency in clinician-collected samples. The study further explored the correlation of Ct values with cytological and histological outcomes, where clinician-collected samples demonstrated superior diagnostic performance, particularly in identifying LSIL and HSIL conditions, evidenced by AUC values of 0.793 and 0.866, respectively. While self-sampling remains a viable method, with sensitivity reaching up to 48.84% for LSIL and 46.15% for HSIL, clinician collection proved more accurate, likely influencing future national screening policies. Conclusions: This work underscores the need for robust sample collection methods and the importance of ongoing enhancements to self-sampling assays and techniques to ensure their efficacy in cervical cancer screening programs.
- 29 September 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (19) , 2177
Open AccessComparative Analysis of HPV Detection Efficiency: Evaluating Cobas 8800 Performance in Vaginal Self-Sampling versus Clinician-Collected Samples at a Regional Thai Hospital
Background: This study, conducted at a regional Thai hospital, assesses the comparative efficacy of self-collected versus clinician-collected samples for HPV detection using the Cobas 8800 system among Thai women aged 30–60. Methods: Our methodology involved analyzing 1541 self-collected and 1398 clinician-collected samples. Results: The results show a statistically significant mean difference in cycle threshold (Ct) values favoring clinician-collected samples (1.53; 95% CI: 1.18–1.87, p < 0.0001). This pattern was consistent across various age groups, with the most pronounced differences noted in the oldest cohort (50–59 years), suggesting higher detection efficiency in clinician-collected samples. The study further explored the correlation of Ct values with cytological and histological outcomes, where clinician-collected samples demonstrated superior diagnostic performance, particularly in identifying LSIL and HSIL conditions, evidenced by AUC values of 0.793 and 0.866, respectively. While self-sampling remains a viable method, with sensitivity reaching up to 48.84% for LSIL and 46.15% for HSIL, clinician collection proved more accurate, likely influencing future national screening policies. Conclusions: This work underscores the need for robust sample collection methods and the importance of ongoing enhancements to self-sampling assays and techniques to ensure their efficacy in cervical cancer screening programs.
- Open Access
- 12 March 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (3) , e0300369
Establishing age and gender-specific serum creatinine reference ranges for Thai pediatric population
Accurate assessment of kidney function in children requires age and gender-specific reference ranges for serum creatinine. Traditional reference values, often derived from adult populations and different ethnic backgrounds, may not be suitable for children. This study aims to establish specific reference ranges for serum creatinine in the Thai pediatric population, addressing the gap in localized and age-appropriate diagnostic criteria. This retrospective study analyzed serum creatinine levels from Thai children aged newborn to 18 years, collected from the Laboratory Information System of the Queen Sirikit National Institute of Child Health from January 2017 to December 2021. The Bhattacharya method was employed to establish reference ranges, considering different age groups and genders. The study compared these newly established reference values with international studies, including those of Schlebusch H., Pottel H., and Chuang GT., to validate their relevance and accuracy. A total of 27,642 data entries (15,396 males and 12,246 females) were analyzed. The study established distinct reference ranges for serum creatinine, which varied significantly across different age groups and between genders. These ranges were found to gradually increase with age from 2 months to 18 years. The study also highlighted notable differences in reference values when compared with other ethnic populations. The study successfully establishes tailored reference ranges for serum creatinine in Thai children, providing a valuable tool for more accurate diagnosis and monitoring of kidney health in this demographic. This initiative marks a significant advancement in pediatric nephrology in Thailand and suggests a need for continuous refinement of these ranges and further research in this area.
- 12 March 2024
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 19 (3) , e0300369
Open AccessEstablishing age and gender-specific serum creatinine reference ranges for Thai pediatric population
Accurate assessment of kidney function in children requires age and gender-specific reference ranges for serum creatinine. Traditional reference values, often derived from adult populations and different ethnic backgrounds, may not be suitable for children. This study aims to establish specific reference ranges for serum creatinine in the Thai pediatric population, addressing the gap in localized and age-appropriate diagnostic criteria. This retrospective study analyzed serum creatinine levels from Thai children aged newborn to 18 years, collected from the Laboratory Information System of the Queen Sirikit National Institute of Child Health from January 2017 to December 2021. The Bhattacharya method was employed to establish reference ranges, considering different age groups and genders. The study compared these newly established reference values with international studies, including those of Schlebusch H., Pottel H., and Chuang GT., to validate their relevance and accuracy. A total of 27,642 data entries (15,396 males and 12,246 females) were analyzed. The study established distinct reference ranges for serum creatinine, which varied significantly across different age groups and between genders. These ranges were found to gradually increase with age from 2 months to 18 years. The study also highlighted notable differences in reference values when compared with other ethnic populations. The study successfully establishes tailored reference ranges for serum creatinine in Thai children, providing a valuable tool for more accurate diagnosis and monitoring of kidney health in this demographic. This initiative marks a significant advancement in pediatric nephrology in Thailand and suggests a need for continuous refinement of these ranges and further research in this area.
- 4 January 2024
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 57 (1) , 161-169
Prevalence and associated factors of dyslipidemia among university students in Central Thailand: a cross-sectional study
Background: Dyslipidemia is regarded as a significant risk factor for atherosclerotic cardiovascular diseases (ASCVDs). Currently, there is limited data regarding dyslipidemia among Thai university students. Objective: This study aimed to examine the prevalence of dyslipidemia and its related factors among university students in the central region of Thailand. Materials and methods: In this cross-sectional study, a total of 434 students aged 18-25 years at Thammasat University and Kasetsart University were recruited using simple random sampling. Fasting venous blood samples were obtained, and plasma lipid profiles were assessed by an automated analyzer. Dyslipidemia was formally characterized according to the National Cholesterol Education Program Adult Treatment Panel (NCEP-ATP III) guidelines. Demographic information, dietary behavior, and physical activity were collected using questionnaires. Anthropometric measures were also performed according to a standard protocol. Results: The prevalence of elevated total cholesterol, high-risk HDL-C, elevated LDL-C, and elevated triglycerides was 30.4, 18.2, 20.0, and 11.8%, respectively. The most common adverse lipid parameter was total cholesterol in both genders. Obesity and high fat intake were significantly associated with dyslipidemia (p<0.05). Conclusion: This research revealed a significant occurrence of dyslipidemia, primarily driven by elevated total cholesterol, among university students in Thailand. Obesity and high fat intake are significant risk contributors to dyslipidemia. These findings emphasize the need for awareness, prevention, and management strategies targeting this population.
- 4 January 2024
- Published by Chiang Mai University in Journal of Associated Medical Sciences
- Vol. 57 (1) , 161-169
Prevalence and associated factors of dyslipidemia among university students in Central Thailand: a cross-sectional study
Background: Dyslipidemia is regarded as a significant risk factor for atherosclerotic cardiovascular diseases (ASCVDs). Currently, there is limited data regarding dyslipidemia among Thai university students. Objective: This study aimed to examine the prevalence of dyslipidemia and its related factors among university students in the central region of Thailand. Materials and methods: In this cross-sectional study, a total of 434 students aged 18-25 years at Thammasat University and Kasetsart University were recruited using simple random sampling. Fasting venous blood samples were obtained, and plasma lipid profiles were assessed by an automated analyzer. Dyslipidemia was formally characterized according to the National Cholesterol Education Program Adult Treatment Panel (NCEP-ATP III) guidelines. Demographic information, dietary behavior, and physical activity were collected using questionnaires. Anthropometric measures were also performed according to a standard protocol. Results: The prevalence of elevated total cholesterol, high-risk HDL-C, elevated LDL-C, and elevated triglycerides was 30.4, 18.2, 20.0, and 11.8%, respectively. The most common adverse lipid parameter was total cholesterol in both genders. Obesity and high fat intake were significantly associated with dyslipidemia (p<0.05). Conclusion: This research revealed a significant occurrence of dyslipidemia, primarily driven by elevated total cholesterol, among university students in Thailand. Obesity and high fat intake are significant risk contributors to dyslipidemia. These findings emphasize the need for awareness, prevention, and management strategies targeting this population.
- Open Access
- 27 July 2023
- Published by Elsevier in Biosensors and Bioelectronics: X
- Vol. 14
A label-free electrochemical biosensor for the detection of alpha-thalassemia 1 (SEA deletion) carriers using screen-printed carbon electrodes
- 27 July 2023
- Published by Elsevier in Biosensors and Bioelectronics: X
- Vol. 14
Open AccessA label-free electrochemical biosensor for the detection of alpha-thalassemia 1 (SEA deletion) carriers using screen-printed carbon electrodes
- Open Access
- 9 December 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 3104
Development of Mia Phenotyping Using Paper-Based Device
The MNS7 (Mia) blood group antigen is found at a different prevalence among different ethnic groups. Anti-Mia can cause hemolytic disease of the fetus and newborn (HDFN) and both acute- and delayed-type hemolytic transfusion reactions (HTR). Mia typing should be performed in donors to prevent life-threatening hemolytic transfusion reactions. The gel card and standard tube methods still need specialized equipment, centrifugation, and expertise for result interpretation. We used a novel paper-based analytical device (PAD) pre-coated with monoclonal IgM anti-Mia for Mia phenotyping. We measured grey pixel intensity in blood typing results for interpretation processing using OpenCV at the sample (SP) and elution parts (EP); furthermore, we used the SP: EP ratio and F-score as analysis criteria. We typed 214 blood EDTA samples with PAD–Mia and then compared with gel card results for setting an analysis criterion. We observed 100% sensitivity, specificity, and accuracy when we applied the SP: EP ratio and F-score with the optimal criterion (1.07 and 0.17 for SP: EP ratio and F-score, respectively). The validation of PAD–Mia typing for blood donor samples (n = 150) via F-score gave 100% sensitivity and specificity when compared with the gel card method; therefore, we argue that PAD–Mia typing can be used for Mia phenotyping without sero-centrifugation. Moreover, to study the correlation between genotype and phenotype, PCR-SSP was performed to identify GYP(B-A-B) hybrids. The results revealed that all Mia+ blood samples gave a positive with GP. Hut, GP. HF, GP. Mur, GP. Hop, and GP. Bun. Results of the gel card method and PCR-SSP were concordant. Hence, using PAD–Mia typing in blood donors would be helpful for creating a phenotype database of blood donors for reducing alloimmunization risks.
- 9 December 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (12) , 3104
Open AccessDevelopment of Mia Phenotyping Using Paper-Based Device
The MNS7 (Mia) blood group antigen is found at a different prevalence among different ethnic groups. Anti-Mia can cause hemolytic disease of the fetus and newborn (HDFN) and both acute- and delayed-type hemolytic transfusion reactions (HTR). Mia typing should be performed in donors to prevent life-threatening hemolytic transfusion reactions. The gel card and standard tube methods still need specialized equipment, centrifugation, and expertise for result interpretation. We used a novel paper-based analytical device (PAD) pre-coated with monoclonal IgM anti-Mia for Mia phenotyping. We measured grey pixel intensity in blood typing results for interpretation processing using OpenCV at the sample (SP) and elution parts (EP); furthermore, we used the SP: EP ratio and F-score as analysis criteria. We typed 214 blood EDTA samples with PAD–Mia and then compared with gel card results for setting an analysis criterion. We observed 100% sensitivity, specificity, and accuracy when we applied the SP: EP ratio and F-score with the optimal criterion (1.07 and 0.17 for SP: EP ratio and F-score, respectively). The validation of PAD–Mia typing for blood donor samples (n = 150) via F-score gave 100% sensitivity and specificity when compared with the gel card method; therefore, we argue that PAD–Mia typing can be used for Mia phenotyping without sero-centrifugation. Moreover, to study the correlation between genotype and phenotype, PCR-SSP was performed to identify GYP(B-A-B) hybrids. The results revealed that all Mia+ blood samples gave a positive with GP. Hut, GP. HF, GP. Mur, GP. Hop, and GP. Bun. Results of the gel card method and PCR-SSP were concordant. Hence, using PAD–Mia typing in blood donors would be helpful for creating a phenotype database of blood donors for reducing alloimmunization risks.
- 13 November 2022
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 82 (7-8) , 581-587
Evaluation of the ESR fast detector and Improve® ESR analyzer as modified Westergren methods for erythrocyte sedimentation rate
The erythrocyte sedimentation rate (ESR) has been commonly ordered in hematology laboratories and used to screen for monitoring responses to therapy and identifying inflammatory conditions. To overcome the limitations of traditional ESR measurements, various methods have been developed and compared to the established reference method. This study evaluates the analytical performance of ESR fast detector and Improve® ESR analyzer compared to the reference method. Method validation and comparison were performed in 189 volunteer blood samples according to the International Council for Standardization in Hematology recommendations. The analytical efficacy of ESR fast detector and Improve® ESR analyzer was also assessed and compared with the reference method and C-reactive protein (CRP) levels. The results demonstrated that the precision of ESR fast detector and Improve® ESR analyzer was considered as the acceptance criterion for the ESR measurement. The method comparison analysis between the two modified Westergren methods and reference method demonstrated a strong correlation with the Spearman’s rank correlation coefficient of 0.94, with a mean difference of −2.1 and −7.7 mm/h in the ESR fast detector and Improve® ESR analyzer, respectively. Analysis of the area under the receiver operating curve illustrated a high analytical performance compared to the reference method and CRP level. The measurement of ESR level using the ESR fast detector and Improve® ESR analyzer is a reliable method and has a high analytical performance, which can be used instead of the reference method for screening inflammatory conditions.
- 13 November 2022
- Published by Taylor & Francis in Scandinavian Journal of Clinical and Laboratory Investigation
- Vol. 82 (7-8) , 581-587
Evaluation of the ESR fast detector and Improve® ESR analyzer as modified Westergren methods for erythrocyte sedimentation rate
The erythrocyte sedimentation rate (ESR) has been commonly ordered in hematology laboratories and used to screen for monitoring responses to therapy and identifying inflammatory conditions. To overcome the limitations of traditional ESR measurements, various methods have been developed and compared to the established reference method. This study evaluates the analytical performance of ESR fast detector and Improve® ESR analyzer compared to the reference method. Method validation and comparison were performed in 189 volunteer blood samples according to the International Council for Standardization in Hematology recommendations. The analytical efficacy of ESR fast detector and Improve® ESR analyzer was also assessed and compared with the reference method and C-reactive protein (CRP) levels. The results demonstrated that the precision of ESR fast detector and Improve® ESR analyzer was considered as the acceptance criterion for the ESR measurement. The method comparison analysis between the two modified Westergren methods and reference method demonstrated a strong correlation with the Spearman’s rank correlation coefficient of 0.94, with a mean difference of −2.1 and −7.7 mm/h in the ESR fast detector and Improve® ESR analyzer, respectively. Analysis of the area under the receiver operating curve illustrated a high analytical performance compared to the reference method and CRP level. The measurement of ESR level using the ESR fast detector and Improve® ESR analyzer is a reliable method and has a high analytical performance, which can be used instead of the reference method for screening inflammatory conditions.