Qi Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qi Zhang has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Mark. E. Meyerhoff
Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States
6 shared publications - Yang Zhou
Key Laboratory of Advanced Materials of Tropical Island Resources of Ministry of Education and School of Chemistry and Chemical Engineering, Hainan University, Haikou, Hainan 570228, China
4 shared publications - Chuanwu Xi
Department of Environmental Health Sciences, University of Michigan School Of Public Health, Ann Arbor, USA
2 shared publications - Jianfeng Wu
Department of Environmental Health Sciences, School of Public Health, University of Michigan, Ann Arbor, MI, 48109, United States
2 shared publications Jinyi Tan
Department of Chemistry, University of Michigan, Ann Arbor, MI 48109, USA
2 shared publications- Xuewei Wang
Virginia Commonwealth University
2 shared publications
Latest Publications
- 13 August 2022
- Published by Springer Nature in Inflammation Research
- Vol. 71  (10-11) , 1305-1313
Comprehensive comparison of the prognostic value of systemic inflammation biomarkers for cancer cachexia: a multicenter prospective study
Aims Systemic inflammation plays an important role in cancer cachexia. However, among the systemic inflammatory biomarkers, it is unclear which has optimal prognostic value for cancer cachexia. Methods The Kaplan–Meier method was used and the log-rank analysis was performed to estimate survival differences between groups. Cox proportional hazard regression analyses were conducted to assess independent risk factors for all-cause mortality. Results The C-reactive protein-to-albumin ratio (CAR) was the optimal prognostic assessment tool for patients with cancer cachexia, with 1-, 3-, and 5-year predictive powers of 0.650, 0.658, and 0.605, respectively. Patients with a high CAR had significantly lower survival rates than those with a low CAR. Moreover, CAR can differentiate the prognoses of patients with the same pathological stage. Cox proportional risk regression analyses showed that a high CAR was an independent risk factor for cancer cachexia. For every standard deviation increase in CAR, the risk of poor prognosis for patients with cancer cachexia was increased by 20% (hazard ratio = 1.200, 95% confidence interval = 1.132–1.273, P < 0.001). Conclusions CAR is an effective representative of systemic inflammation and a powerful factor for predicting the life function and clinical outcome of patients with cancer cachexia.
- 13 August 2022
- Published by Springer Nature in Inflammation Research
- Vol. 71  (10-11) , 1305-1313
Comprehensive comparison of the prognostic value of systemic inflammation biomarkers for cancer cachexia: a multicenter prospective study
Aims Systemic inflammation plays an important role in cancer cachexia. However, among the systemic inflammatory biomarkers, it is unclear which has optimal prognostic value for cancer cachexia. Methods The Kaplan–Meier method was used and the log-rank analysis was performed to estimate survival differences between groups. Cox proportional hazard regression analyses were conducted to assess independent risk factors for all-cause mortality. Results The C-reactive protein-to-albumin ratio (CAR) was the optimal prognostic assessment tool for patients with cancer cachexia, with 1-, 3-, and 5-year predictive powers of 0.650, 0.658, and 0.605, respectively. Patients with a high CAR had significantly lower survival rates than those with a low CAR. Moreover, CAR can differentiate the prognoses of patients with the same pathological stage. Cox proportional risk regression analyses showed that a high CAR was an independent risk factor for cancer cachexia. For every standard deviation increase in CAR, the risk of poor prognosis for patients with cancer cachexia was increased by 20% (hazard ratio = 1.200, 95% confidence interval = 1.132–1.273, P < 0.001). Conclusions CAR is an effective representative of systemic inflammation and a powerful factor for predicting the life function and clinical outcome of patients with cancer cachexia.
- 1 August 2021
- Published by Elsevier in Mechatronics
- Vol. 77, 102584
Muscle-like contraction control of tendon-sheath artificial muscle
- 1 August 2021
- Published by Elsevier in Mechatronics
- Vol. 77, 102584
Muscle-like contraction control of tendon-sheath artificial muscle
- 29 September 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92  (20) , 13641-13646
Enhanced Hemocompatibility and In Vivo Analytical Accuracy of Intravascular Potentiometric Carbon Dioxide Sensors via Nitric Oxide Release
In this report, the innate ability of nitric oxide (NO) to inhibit platelet activation/adhesion/thrombus formation is employed to improve the hemocompatibility and in vivo accuracy of an intravascular potentiometric PCO2 (partial pressure of carbon dioxide) sensor. The catheter-type sensor is fabricated by impregnating a segment of dual lumen silicone tubing with a proton ionophore, plasticizer and lipophilic cation-exchanger. Subsequent filling of bicarbonate and strong buffer solutions, and placement of Ag/AgCl reference electrode wires within each lumen, respectively, enables measurement of the membrane potential difference across the inner wall of the tube, with this potential changing as a function of the logarithm of sample PCO2. The dual lumen device is further encapsulated within a S-nitroso-N-acetyl-DL-penicillamine (SNAP)-doped silicone tube that releases physiological levels of NO. The NO releasing sensor exhibits near-Nernstian sensitivity towards PCO2 (slope = 59.31 ± 0.78 mV/decade) and low drift rates (< 2 mV/24h after initial equilibration). In vivo evaluation of the NO releasing sensors performed in the arteries and veins of anesthetized pigs for 20 h shows enhanced accuracy (vs. non-NO release sensors) when benchmarked to measurements of discrete blood samples made with a commercial blood gas analyzer. The accurate, continuous monitoring of blood PCO2 levels achieved with this new IV NO releasing PCO2 sensor configuration could help better manage hospitalized patients in critical care units.
- 29 September 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92  (20) , 13641-13646
Enhanced Hemocompatibility and In Vivo Analytical Accuracy of Intravascular Potentiometric Carbon Dioxide Sensors via Nitric Oxide Release
In this report, the innate ability of nitric oxide (NO) to inhibit platelet activation/adhesion/thrombus formation is employed to improve the hemocompatibility and in vivo accuracy of an intravascular potentiometric PCO2 (partial pressure of carbon dioxide) sensor. The catheter-type sensor is fabricated by impregnating a segment of dual lumen silicone tubing with a proton ionophore, plasticizer and lipophilic cation-exchanger. Subsequent filling of bicarbonate and strong buffer solutions, and placement of Ag/AgCl reference electrode wires within each lumen, respectively, enables measurement of the membrane potential difference across the inner wall of the tube, with this potential changing as a function of the logarithm of sample PCO2. The dual lumen device is further encapsulated within a S-nitroso-N-acetyl-DL-penicillamine (SNAP)-doped silicone tube that releases physiological levels of NO. The NO releasing sensor exhibits near-Nernstian sensitivity towards PCO2 (slope = 59.31 ± 0.78 mV/decade) and low drift rates (< 2 mV/24h after initial equilibration). In vivo evaluation of the NO releasing sensors performed in the arteries and veins of anesthetized pigs for 20 h shows enhanced accuracy (vs. non-NO release sensors) when benchmarked to measurements of discrete blood samples made with a commercial blood gas analyzer. The accurate, continuous monitoring of blood PCO2 levels achieved with this new IV NO releasing PCO2 sensor configuration could help better manage hospitalized patients in critical care units.
- 19 May 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12  (23) , 25616-25624
Plasticizer-Free Thin-Film Sodium-Selective Optodes Inkjet-Printed on Transparent Plastic for Sweat Analysis
A novel strategy to functionalize transparent flexible plastic films with an optical ion sensing layer using an inkjet printing technology is described. The hydrophobic sensing chemicals that include a sodium ionophore, a lipophilic proton chromoionophore, and a lipophilic ion-exchanger are co-deposited onto substrates such as transparent polyester (PE) film sheets in the absence of any plasticizer and/or hydrophobic polymer matrix. The inkjet-printing process enables the formation of optode films with nanoscale thickness/roughness that readily facilitate interfacing with aqueous samples. Using a smartphone detector, the colorimetric response of the optodes is shown to reach 95% of equilibrium values within 100 s in response to different concentrations of sodium ions, which is more rapid than traditional ion-selective optodes based on plasticized PVC films as the sensing layer. The new optodes also exhibit high selectivity to Na+ over interfering ions including K+, Ca2+ and Mg2+. Chemical leaching experiments show that the highly hydrophobic optode components remain in place on the plastic substrate surface. Hence, excellent sensor stability and fully reversible optical responses are obtained, which is essential for potential continuous monitoring applications. Further testing of the sensors with undiluted human sweat samples is shown to yield accurate values for sodium concentrations. Therefore, the use of plasticizer-free ion-selective optode nanolayers that enable highly selective ion sensing on a clear plastic support is likely to expand the range of available chemical sensors suited for preparing wearable real-time sweat analysis devices.
- 19 May 2020
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 12  (23) , 25616-25624
Plasticizer-Free Thin-Film Sodium-Selective Optodes Inkjet-Printed on Transparent Plastic for Sweat Analysis
A novel strategy to functionalize transparent flexible plastic films with an optical ion sensing layer using an inkjet printing technology is described. The hydrophobic sensing chemicals that include a sodium ionophore, a lipophilic proton chromoionophore, and a lipophilic ion-exchanger are co-deposited onto substrates such as transparent polyester (PE) film sheets in the absence of any plasticizer and/or hydrophobic polymer matrix. The inkjet-printing process enables the formation of optode films with nanoscale thickness/roughness that readily facilitate interfacing with aqueous samples. Using a smartphone detector, the colorimetric response of the optodes is shown to reach 95% of equilibrium values within 100 s in response to different concentrations of sodium ions, which is more rapid than traditional ion-selective optodes based on plasticized PVC films as the sensing layer. The new optodes also exhibit high selectivity to Na+ over interfering ions including K+, Ca2+ and Mg2+. Chemical leaching experiments show that the highly hydrophobic optode components remain in place on the plastic substrate surface. Hence, excellent sensor stability and fully reversible optical responses are obtained, which is essential for potential continuous monitoring applications. Further testing of the sensors with undiluted human sweat samples is shown to yield accurate values for sodium concentrations. Therefore, the use of plasticizer-free ion-selective optode nanolayers that enable highly selective ion sensing on a clear plastic support is likely to expand the range of available chemical sensors suited for preparing wearable real-time sweat analysis devices.
- 1 September 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 96, 55-67
Recent advances in polymer-based drug delivery systems for local anesthetics
- 1 September 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 96, 55-67
Recent advances in polymer-based drug delivery systems for local anesthetics
- 1 May 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 90, 112-121
Nitric oxide releasing poly(vinylidene fluoride-co-hexafluoropropylene) films using a fluorinated nitric oxide donor to greatly decrease chemical leaching
- 1 May 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 90, 112-121
Nitric oxide releasing poly(vinylidene fluoride-co-hexafluoropropylene) films using a fluorinated nitric oxide donor to greatly decrease chemical leaching
- 1 May 2019
- Published by Elsevier in Coordination Chemistry Reviews
- Vol. 387, 154-179
Recent advances in delivery of photosensitive metal-based drugs
- 1 May 2019
- Published by Elsevier in Coordination Chemistry Reviews
- Vol. 387, 154-179
Recent advances in delivery of photosensitive metal-based drugs
- 1 April 2019
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1053, 155-161
Colorimetric copper ion sensing in solution phase and on paper substrate based on catalytic decomposition of S-nitrosothiol
- 1 April 2019
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1053, 155-161
Colorimetric copper ion sensing in solution phase and on paper substrate based on catalytic decomposition of S-nitrosothiol
- Open Access
- 31 March 2019
- Published by MDPI AG in Biosensors
- Vol. 9  (2) , 50
Optimization of the Electrodeposition of Gold Nanoparticles for the Application of Highly Sensitive, Label-Free Biosensor
A highly sensitive electrochemical biosensor with a signal amplification platform of electrodeposited gold nanoparticle (AuNP) has been developed and characterized. The sizes of the synthesized AuNP were found to be critical for the performance of biosensor in which the sizes were dependent on HAuCl4 and acid concentrations; as well as on scan cycles and scan rates in the gold electro-reduction step. Systematic investigations of the adsorption of proteins with different sizes from aqueous electrolyte solution onto the electrodeposited AuNP surface were performed with a potentiometric method and calibrated by design of experiment (DOE). The resulting amperometric glucose biosensors was demonstrated to have a low detection limit (>50 μM) and a wide linear range after optimization with AuNP electrodeposition.
- 31 March 2019
- Published by MDPI AG in Biosensors
- Vol. 9  (2) , 50
Open AccessOptimization of the Electrodeposition of Gold Nanoparticles for the Application of Highly Sensitive, Label-Free Biosensor
A highly sensitive electrochemical biosensor with a signal amplification platform of electrodeposited gold nanoparticle (AuNP) has been developed and characterized. The sizes of the synthesized AuNP were found to be critical for the performance of biosensor in which the sizes were dependent on HAuCl4 and acid concentrations; as well as on scan cycles and scan rates in the gold electro-reduction step. Systematic investigations of the adsorption of proteins with different sizes from aqueous electrolyte solution onto the electrodeposited AuNP surface were performed with a potentiometric method and calibrated by design of experiment (DOE). The resulting amperometric glucose biosensors was demonstrated to have a low detection limit (>50 μM) and a wide linear range after optimization with AuNP electrodeposition.
- 4 December 2018
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 55  (3) , 401-404
Synthesis and nitric oxide releasing properties of novel fluoro S -nitrosothiols
A series of new fluoro S-nitrosothiols is reported as potential nitric oxide (NO) donors. A three-step synthesis and the NO releasing kinetic profiles of these species are presented. The stoichiometric release of NO, with the clean formation of corresponding disulfides, confirms that these new species can facilitate their application as NO donors for various applications including creating novel antimicrobial and thromboresistant fluoropolymer-based medical devices.
- 4 December 2018
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 55  (3) , 401-404
Synthesis and nitric oxide releasing properties of novel fluoro S -nitrosothiols
A series of new fluoro S-nitrosothiols is reported as potential nitric oxide (NO) donors. A three-step synthesis and the NO releasing kinetic profiles of these species are presented. The stoichiometric release of NO, with the clean formation of corresponding disulfides, confirms that these new species can facilitate their application as NO donors for various applications including creating novel antimicrobial and thromboresistant fluoropolymer-based medical devices.