ETEnrico Primo Tomasini

Enrico Primo Tomasini

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Enrico Primo Tomasini has a total of 146 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigating Additive Manufactured Lattice Structures: A Multi-Instrument Approach

    by Gloria Allevi, Lorenzo Capponi, Paolo Castellini, Paolo Chiariotti, Franco Docchio, Fabrizio Freni, Roberto Marsili, Milena Martarelli, Roberto Montanini, Simone Pasinetti, et al.

    Additive manufacturing (AM) is gaining relevance for the freedom it gives to designers in experimenting topologically optimized components, especially those having lattice morphology. Indeed, these are of great interest in various application fields (automotive, biomedical, etc.) because, in addition to a significant mass reduction, lattice topology (micro-scale) can be tuned to provide the final product (macro-scale) with the specific properties it needs to exhibit. However, additive manufactured lattice structures are still to be fully investigated, given the mismatch between the designed and the manufactured final product. This paper presents some preliminary results from a multi-instrument approach, grounding on non-contact measurement techniques, to characterize lattice and trabecular structures in terms of dimensional accuracy, surface morphology, stress-strain distribution and modal behavior.


  • Bioimpedancemetry for the assessment of periodontal tissue inflammation: a numerical feasibility study

    by Gloria Cosoli, Lorenzo Scalise, Graziano Cerri, Paola Russo, Gerardo Tricarico, Enrico Primo Tomasini

    In dentistry possible inflammatory episodes of oral cavity can be very frequent (periodontitis, mucositis, peri-implantitis) and they can have serious consequences. Indeed, peri-implantitis is still the principal cause of implant failure. Impedance values of biological tissues are related to the physiological/pathological state of the tissue itself. In fact, an inflamed site exhibits an impedance value lower than that of the corresponding healthy tissue. Based on these observations, the aim of this work is to determine if impedancemetric measurements are able to provide information about the inflammatory state of tissues. A numerical 3D model has been realized to simulate the measurement conditions present in the event of inflammation around a dental implant. The aim is to understand if it is possible to determine the presence of an inflamed tissue and to locate its site, so that the treatment could be specifically focused in that specific area. A simplified geometry reproducing the implant has been realized in order to validate the numerical model by means of experimental measurements. The obtained results are satisfactorily accurate, so the model can be considered reliable. Therefore, multiple simulations have been run on the original model to carry out a parametric study in terms of different conductivity values, different volumes of inflamed tissues and different measurement frequencies. The advantages and limits of such a method have been shown to properly define the main constraints for the system design.


  • Optimal peripheral measurement point for the assessment of preterm patients in intensive care units

    by Ilaria Ercoli, Lorenzo Scalise, Paolo Marchionni, Enrico Primo Tomasini, Virginio Paolo Carnielli

    In neonatal intensive care units many important vital signs are continuously measured in order to have a full monitoring of the patient. To this aim, cardiac rate, respiration activity, blood saturation, body temperature are extensively collected by contact sensors. Temperature, particularly in preterm infants, is a key quantity to be assessed if the aim is to verify the patient development and is/her capacity to regulate the body temperature. Presently, hospital cribs are equipped with large resistance thermometers (two or more); one for measuring temperature at the hepatic site and the second to assess temperature from peripheral sites (i.e. arms, legs). The aim of this paper is to identify the optimal measurement point for the assessment of the skin temperature in peripheral sites. The experimental procedure utilized is based on the use of a multi-point (6 sensing points) measurement system of the skin temperature and of the crib environmental temperature. In this study, 50 premature patients (mean gestation age 34 weeks and mean weight 1791 g) have been measured. Results demonstrate that from the measured data, it is possible to correctly identify the left hand as the measurement point presenting the smallest differences (<; 1.04°C), respect to the central body temperature values (measured in correspondence to the liver).

  • Characterization and calibration of the central arterial pressure waveform obtained from vibrocardiographic signal

    by L. Casacanditella, G. Cosoli, S. Casaccia, J. W. Rohrbaugh, L. Scalise, E. P. Tomasini

    Laser Doppler Vibrometry (LDV) has been demonstrated to be a non-contact technique with high sensitivity, able to measure the skin vibrations related to cardiac activity. The obtainable mechanical signal (i.e. a velocity signal), VibroCardioGram (VCG), is able to provide significant physiological parameters, such as Heart Rate (HR). In this work, the authors aim to present a non-contact measurement method to obtain the arterial blood pressure signal from the mechanical vibrations assessed by LDV, in a central district of the arterial tree, such as carotid artery. In fact, in this way it is possible to indirectly assess Central Arterial Blood Pressure (CABP), which indicates the hemodynamic load on the heart, so that it is considered an important index predicting the cardiac risk of a subject. The measurement setup involves the use of an oscillometric cuff, to measure peripheral blood pressure at the radial artery level. Diastolic and Mean Arterial Pressure (MAP) at radial level were used to calibrate the integrated LDV signal (i.e. a displacement signal). As regard calibration, an exponential mathematical model was adopted to derive the pressure waveform from the displacement of the vessel detected by LDV. Results show an average difference of around 20% between systolic pressure measured at brachial level (i.e. peripheral pressure value) and systolic pressure derived from VCG signal measured over the carotid artery (i.e. central pressure). This is a physiological difference, consistent with the literature about the physiological increase of Systolic Blood Pressure (SBP) and Pressure Pulse (PP) at increased distances from the heart. However, this non-contact technique is affected by movement artifacts and by reflection phenomena not related to the studied vessel and so it is necessary to account of such issues in the results.


  • A measurement procedure for the assessment of thermoregulatory activitity in premature babies

    by Ilaria Ercoli, Lorenzo Scalise, Annalisa Cenci, Paolo Marchionni, Enrico Primo Tomasini, Virginio Paolo Carnielli

    Many important vital signs need to be measured on preterm patients when they are recovered in intensive care units: cardiac rate, respiration activity, blood saturation, temperature. The later is, in particular, a key quantity to assess when the aim is to verify if the patient has fully developed the capacity to regulate his/her temperature. Presently, the procedure followed by clinicians is based on a subjective test, which sees the heating system of the curl switched off; if the central temperature of the patient will not be reduced below 35°C in the following two hours, the patient is considered able to thermoregulate himself. The aim of this paper is to propose a measurement procedure aiming to verify if the patient has the ability to autonomously thermoregulate. The procedure is based on the use of a multipoint (up to 16 sensing points), measurement system of the superficial temperature, that can assess the patient temperature (on 6 sites) and the surrounding temperature (inside and outside the crib), while the heating system is switched off. In this paper, 48 premature patients (mean gestation age 34 week and mean weight 1791 g) have been tested. Results demonstrate that from the measured data, it is possible to correctly identify patients with an adequate thermoregulation capacity (sensitivity of 0.81 and specificity of 0.89) and with a rapid procedure (<; 5 min).


  • Non-contact assessment of muscle contraction: Laser Doppler Myography

    by Sara Casaccia, Lorenzo Scalise, Luigi Casacanditella, Enrico P. Tomasini, John W. Rohrbaugh

    Electromyography (EMG) is the gold-standard technique used for the evaluation of muscle activity and contraction. The EMG signal supports analysis of a number of important parameters including amplitude and duration, engagement of motor units, and functional characteristics associated with factors such a force production and fatigue. Recently, a novel measurement method (Laser Doppler Myography, LDM) for the non-contact assessment of muscle activity has been proposed to measure the vibro-mechanical behavior of the muscles that conventionally is referred to as the mechanomyogram (MMG). The fact that contracting skeletal muscles produce vibrations and sounds has been known for more than three centuries. The aim of this study is to report on the LDM technique and to evaluate its capacity to measure without contact some characteristics properties of skeletal muscle contractions. This is accomplished with the very high vibration sensitivity inherent in the Laser Doppler Vibrometry method (in comparison to commonly used devices such as microphones, piezo electric pressure sensors, and accelerometers). Data measured by LDM are compared with signals measured using standard surface EMG (sEMG) which requires the use of skin electrodes. sEMG and LDM signals are simultaneously acquired and processed. The LDM and sEMG signals are compared with respect to the critical features of muscle activation timing, signal amplitude and force production. LDM appears to be a reliable and promising technique that allows measurement without the need for contact with the patient skin. LDM has additional potential advantages in terms of sensor properties, insofar as there are no significant issues relating to bandwidth or sensor resonance, and no mass loading is applied to the skin.


  • Experimental investigation by laser ultrasonics for high speed train axle diagnostics

    by A. Cavuto, M. Martarelli, G. Pandarese, G.M. Revel, E.P. Tomasini


  • Nondestructive Evaluation of Plasters on Historical Thin Vaults by Scanning Laser Doppler Vibrometers

    by M. Martarelli, P. Castellini, E. Quagliarini, E. Seri, S. Lenci, E. P. Tomasini


  • Non contact measurement of heart and respiration rates based on Kinect™

    by Natascia Bernacchia, Lorenzo Scalise, Luigi Casacanditella, Ilaria Ercoli, Paolo Marchionni, Enrico Primo Tomasini

    Heart Rate (HR) and Respiration Rate (RR) are considered among the most useful biomedical signals to be observed from a subject in order to evaluate his/her health conditions. HR and RR are routinely monitored in patients recovered in hospitals and eventual variations of these quantities need to be measured and reported. Today HR and RR are measured with standard methods: electrocardiography (ECG) and spirometry (SP). Both this methods need to be in contact with the subject and require the presence of expert personnel to be correctly operated. Consequently, their use is limited to hospitals or ambulatory environments and their diffusion in domestic environments is rare. In this paper we present a novel method for the measurement of HR and RR without contact on a subject. The proposed method is realized by means of a Kinect ™ Device (KD). The KD is a widely-diffused multi-sensors device based on a depth-sensor, a camera-sensor and 4 microphones. In our work it has been used in conjunction with a special processing algorithm to calculate the HR and RR values. In order to measure HP and RR 10 healthy subjects were observed with the proposed method and with reference methods (ECG and a SP). Results from tests show that the standard deviation of the residuals (difference between the ECG or SP data and the corresponding measurements obtained by KD) are 6% and 9.7% for HR and RR values respectively. Therefore the proposed measurement method, based on the use of KD, could be used for the home-monitoring of HR and RR values in healthy subject without the presence of experts or clinicians.


  • Vibration transmissibility on rifle shooter: A comparison between accelerometer and laser Doppler vibrometer data

    by L. Scalise, L. Casacanditella, C. Santolini, M. Martarelli, E. P. Tomasini

    The transmission of mechanical vibrations from tools to human subjects is known to be potentially dangerous for the circulatory and neurological systems. It is also known that such damages are strictly depending on the intensity and the frequency range of the vibrational signals transferred to the different anatomical districts. In this paper, very high impulsive signals, generated during a shooting by a rifle, will be studied, being such signals characterised by a very high acceleration amplitude as well as high frequency range. In this paper, it will be presented an experimental setup aimed to collect experimental data relative to the transmission of the vibration signals from the rifle to the shoulder of subject during the shooting action. In particular the transmissibility of acceleration signals, as well as of the velocity signals, between the rifle stock and the subject's back shoulder will be measured using two piezoelectric accelerometers and a single point laser Doppler vibrometer (LDV). Tests have been carried out in a shooting lab where a professional shooter has conducted the experiments, using different experimental configurations: two different types of stocks and two kinds of bullets with different weights were considered. Two uniaxial accelerometers were fixed on the stock of the weapon and on the back of the shoulder of the shooter respectively. Vibration from the back shoulder was also measured by means of a LDV simultaneously. A comparison of the measured results will be presented and the pros and cons of the use of contact and non-contact transducers will be discussed taking into account the possible sources of the measurement uncertainty as unwanted sensor vibrations for the accelerometer.