NSNellie Della Schiava

Nellie Della Schiava

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nellie Della Schiava has a total of 81 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Midterm Aortic Neck Evolution after EndoSuture Aneurysm Repair: a Single Centre Retrospective Analysis

    by Raffaele Pio Ammollo, Nicolas Mauchien, Alexandre Oliny, Marine Bordet, Nellie Della Schiava, Antoine Millon


  • Cold Storage of Human Femoral Arteries for Twelve Months: Impact on Mechanical Properties

    by Marine Bordet, Guilhem Rival, Laurence Seveyrat, Antoine Millon, Jean-Fabien Capsal, Pierre-Jean Cottinet, Minh Quyen Le, Nellie Della Schiava


  • Open Access

    Design Optimization of Printed Multi-Layered Electroactive Actuators Used for Steerable Guidewire in Micro-Invasive Surgery

    by Simon Toinet, Mohammed Benwadih, Helga Szambolics, Christine Revenant, David Alincant, Marine Bordet, Jean-Fabien Capsal, Nellie Della-Schiava, Minh-Quyen Le, Pierre-Jean Cottinet

    To treat cardiovascular diseases (i.e., a major cause of mortality after cancers), endovascular-technique-based guidewire has been employed for intra-arterial navigation. To date, most commercially available guidewires (e.g., Terumo, Abbott, Cordis, etc.) are non-steerable, which is poorly suited to the human arterial system with numerous bifurcations and angulations. To reach a target artery, surgeons frequently opt for several tools (guidewires with different size integrated into angulated catheters) that might provoke arterial complications such as perforation or dissection. Steerable guidewires would, therefore, be of high interest to reduce surgical morbidity and mortality for patients as well as to simplify procedure for surgeons, thereby saving time and health costs. Regarding these reasons, our research involves the development of a smart steerable guidewire using electroactive polymer (EAP) capable of bending when subjected to an input voltage. The actuation performance of the developed device is assessed through the curvature behavior (i.e., the displacement and the angle of the bending) of a cantilever beam structure, consisting of single- or multi-stack EAP printed on a substrate. Compared to the single-stack architecture, the multi-stack gives rise to a significant increase in curvature, even when subjected to a moderate control voltage. As suggested by the design framework, the intrinsic physical properties (dielectric, electrical, and mechanical) of the EAP layer, together with the nature and thickness of all materials (EAP and substrate), do have strong effect on the bending response of the device. The analyses propose a comprehensive guideline to optimize the actuator performance based on an adequate selection of the relevant materials and geometric parameters. An analytical model together with a finite element model (FEM) are investigated to validate the experimental tests. Finally, the design guideline leads to an innovative structure (composed of a 10-stack active layer screen-printed on a thin substrate) capable of generating a large range of bending angle (up to 190°) under an acceptable input level of 550 V, which perfectly matches the standard of medical tools used for cardiovascular surgery.


  • An angiosome-centred approach for TcpO2 electrode positioning

    by Judith Catella, Nellie Della Schiava, Fortunat L’hOia, Patrick Lermusiaux, Antoine Millon, Anne Long

    Summary: Background: The latest guidelines propose a TcpO2 value of 30 mmHg to help to confirm the diagnosis of chronic limb threatening ischemia. However, placement of electrodes is not standardised. The relevance of an “angiosome-centred” approach for TcpO2 electrode positioning has never been evaluated. We therefore retrospectively analysed our TcpO2 results to study the impact of electrode placement on the different angiosomes of the foot. Patients and methods: Patients consulting the vascular medicine department laboratory for suspicion of CLTI using TcpO2 electrodes placement on the different angiosome arteries of the foot (first inter metatarsal space, lateral edge of the foot and plantar side of the foot) were included. As the mean intra-individual variation is reported to be 8 mmHg, a variation of mean TcpO2 for the 3 locations ≤8 mmHg was considered to be not clinically significant. Results: Thirty-four patients (34 ischemic legs) were analysed. The mean TcpO2 was higher at the lateral edge of the foot (55 mmHg) and plantar side of the foot (65 mmHg) than at the first intermetatarsal space (48 mmHg). There was no clinically significant variation of mean TcpO2 according to anterior/posterior tibial artery patency and fibular artery patency. This was present when stratifying on the number of patent arteries. Conclusions: The present study suggests that multi-electrode TcpO2 is not useful to assess tissue oxygenation in the different angiosomes of the foot to guide surgical decision; first intermetatarsal electrode alone would be preferred. TcpO2 seems rather to evaluate overall tissue oxygenation of the foot. Electrode location on the plantar side of the foot may overestimate results and lead to misinterpretation.


  • Open Access

    A Wound Environment Control System to Avoid Major Amputation in Diabetic Foot Ulcers

    by Julien Vouillarmet, Gisele Fribourg, Lauriane Labaisse, Nellie Della-Schiava

    We report the case of a 58-year-old patient with a diabetic foot lesion at high risk of major amputation successfully treated by a new innovative wound environment control system.


  • Open Access

    Investigation of Blood Coagulation Using Impedance Spectroscopy: Toward Innovative Biomarkers to Assess Fibrinogenesis and Clot Retraction

    by Giulia D’ambrogio, Omar Zahhaf, Minh-Quyen Le, Yves Gouriou, Laurie Josset, Vincent Pialoux, Patrick Lermusiaux, Jean-Fabien Capsal, Pierre-Jean Cottinet, Nellie Della Schiava

    This study focused on a coagulation assessment based on the novel technique of blood-impedance-magnitude measurement. With the impedance characterization of recalcified human blood, it was possible to identify two significative biomarkers (i.e., measurable indicators) related to fibrin formation (1st marker) and clot retraction (2nd marker). The confocal microscopy of clotting blood provided a complete visual analysis of all the events occurring during coagulation, validating the significance of the impedance biomarkers. By analyzing the impedance phase angle (Φ) of blood during coagulation, as well as those of the clot and serum expelled after retraction, it was possible to further clarify the origin of the 2nd marker. Finally, an impedance-magnitude analysis and a rotational thromboelastometry test (ROTEM®) were simultaneously performed on blood sampled from the same donor; the results pointed out that the 1st marker was related to clotting time. The developed technique gives rise to a comprehensive and evolutive insight into coagulation, making it possible to progressively follow the whole process in real time. Moreover, this approach allows coagulation to be tested on any materials’ surface, laying the ground for new studies related to contact coagulation, meaning, thrombosis occurring on artificial implants. In a near future, impedance spectroscopy could be employed in the material characterization of cardiovascular prostheses whose properties could be monitored in situ and/or online using effective biomarkers.


  • Résultats du questionnaire sur les pratiques de la TcPO2

    by Judith Catella, Nellie Della Schiava, Luca Calanca, Eric Steinmetz, Antoine Millon, Guillaume Mahe, Anne Long, Lucia Mazzolai