Kiwamu Izumi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kiwamu Izumi has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Kentaro Komori
University of Tokyo
4 shared publications - Koji Nagano
Institute for Multidisciplinary Sciences, Yokohama National University, Yokohama, Kanagawa 240-8501, Japan
4 shared publications - Masaki Ando
The University of Tokyo
3 shared publications Isao Kawano
Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, Sagamihara, Kanagawa 252-5210, Japan
2 shared publications- Mitsuru Musha
Institute for Laser Science, University of Electro-Communications, Chofu, Tokyo 182-8585, Japan
2 shared publications - Satoshi Ikari
Department of Aeronautics and Astronautics, University of Tokyo, Bunkyo, Tokyo 113-8656, Japan
2 shared publications
Latest Publications
- 23 November 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 43 (12) , 2063
Range emulator: a compact paraxial optical system to emulate long-distance monochromatic laser propagation
Emulating long-distance light propagation on a laboratory scale is essential for the ground-based testing of intersatellite optical systems. To address this challenge, we propose and analyze an optical system called the range emulator (RE) to reproduce the spatial propagation effects of a long-distance beam within a compact apparatus. Our analysis identifies the three-lens solutions that implement the RE. Through a numerical exploration, we quantify the fundamental trade-off between system compactness and manufacturing precision. This work provides a practical framework for designing compact optical testbeds for future multi-satellite laser link technologies.
- 23 November 2026
- Published by Optica Publishing Group in Journal of the Optical Society of America A
- Vol. 43 (12) , 2063
Range emulator: a compact paraxial optical system to emulate long-distance monochromatic laser propagation
Emulating long-distance light propagation on a laboratory scale is essential for the ground-based testing of intersatellite optical systems. To address this challenge, we propose and analyze an optical system called the range emulator (RE) to reproduce the spatial propagation effects of a long-distance beam within a compact apparatus. Our analysis identifies the three-lens solutions that implement the RE. Through a numerical exploration, we quantify the fundamental trade-off between system compactness and manufacturing precision. This work provides a practical framework for designing compact optical testbeds for future multi-satellite laser link technologies.
- 21 November 2025
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 42 (22) , 225027
Initial acquisition requirements for optical cavities in the space gravitational wave antennae DECIGO and B-DECIGO
DECIGO (DECi-hertz Interferometer Gravitational Wave Observatory) is a space-based gravitational wave antenna concept targeting the 0.1–10 Hz band. It consists of three spacecraft arranged in an equilateral triangle with 1000 km sides, forming Fabry–Pérot cavities between them. A precursor mission, B-DECIGO, is also planned, featuring a smaller 100 km triangle. Operating these cavities requires ultra-precise formation flying, where inter-mirror distance and alignment must be precisely controlled. Achieving this necessitates a sequential improvement in precision using various sensors and actuators, from the deployment of the spacecraft to laser link acquisition and ultimately to the control of the Fabry–Pérot cavities to maintain resonance. In this paper, we derive the precision requirements at each stage and discuss the feasibility of achieving them. We show that the relative speed between cavity mirrors must be controlled at the sub-micrometer-per-second level and that relative alignment must be maintained at the sub-microradian level to obtain control signals from the Fabry–Pérot cavities of DECIGO and B-DECIGO.
- 21 November 2025
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 42 (22) , 225027
Initial acquisition requirements for optical cavities in the space gravitational wave antennae DECIGO and B-DECIGO
DECIGO (DECi-hertz Interferometer Gravitational Wave Observatory) is a space-based gravitational wave antenna concept targeting the 0.1–10 Hz band. It consists of three spacecraft arranged in an equilateral triangle with 1000 km sides, forming Fabry–Pérot cavities between them. A precursor mission, B-DECIGO, is also planned, featuring a smaller 100 km triangle. Operating these cavities requires ultra-precise formation flying, where inter-mirror distance and alignment must be precisely controlled. Achieving this necessitates a sequential improvement in precision using various sensors and actuators, from the deployment of the spacecraft to laser link acquisition and ultimately to the control of the Fabry–Pérot cavities to maintain resonance. In this paper, we derive the precision requirements at each stage and discuss the feasibility of achieving them. We show that the relative speed between cavity mirrors must be controlled at the sub-micrometer-per-second level and that relative alignment must be maintained at the sub-microradian level to obtain control signals from the Fabry–Pérot cavities of DECIGO and B-DECIGO.
- Open Access
- 21 August 2025
- Published by Oxford University Press (OUP) in Publications of the Astronomical Society of Japan
- Vol. 77 (5) , 1080-1089
SILVIA: Ultra-precision formation flying demonstration for space-based interferometry
We propose a mission concept, called the space interferometer laboratory voyaging towards innovative applications (SILVIA), designed to demonstrate ultra-precision formation flying between three spacecraft separated by 100 m. SILVIA aims to achieve submicrometer precision in relative distance control by integrating spacecraft sensors, laser interferometry, low-thrust, and low-noise micro-propulsion for real-time measurement and control of distances and relative orientations between spacecraft. A 100 m scale mission in a near-circular low Earth orbit has been identified as an ideal, cost-effective setting for demonstrating SILVIA, as this configuration maintains a good balance between small relative perturbations and low risk of collision. This mission will fill the current technology gap towards future missions, including gravitational wave observatories such as the decihertz interferometer gravitational wave observatory (DECIGO), designed to detect the primordial gravitational-wave background, and high-contrast nulling infrared interferometers such as the large interferometer for exoplanets (LIFE), designed for direct imaging of thermal emissions from nearby terrestrial planet candidates. The mission concept and its key technologies are outlined, paving the way for the next generation of high-precision space-based observatories.
- 21 August 2025
- Published by Oxford University Press (OUP) in Publications of the Astronomical Society of Japan
- Vol. 77 (5) , 1080-1089
Open AccessSILVIA: Ultra-precision formation flying demonstration for space-based interferometry
We propose a mission concept, called the space interferometer laboratory voyaging towards innovative applications (SILVIA), designed to demonstrate ultra-precision formation flying between three spacecraft separated by 100 m. SILVIA aims to achieve submicrometer precision in relative distance control by integrating spacecraft sensors, laser interferometry, low-thrust, and low-noise micro-propulsion for real-time measurement and control of distances and relative orientations between spacecraft. A 100 m scale mission in a near-circular low Earth orbit has been identified as an ideal, cost-effective setting for demonstrating SILVIA, as this configuration maintains a good balance between small relative perturbations and low risk of collision. This mission will fill the current technology gap towards future missions, including gravitational wave observatories such as the decihertz interferometer gravitational wave observatory (DECIGO), designed to detect the primordial gravitational-wave background, and high-contrast nulling infrared interferometers such as the large interferometer for exoplanets (LIFE), designed for direct imaging of thermal emissions from nearby terrestrial planet candidates. The mission concept and its key technologies are outlined, paving the way for the next generation of high-precision space-based observatories.
- 14 May 2025
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 42 (10) , 105007
Demonstration of tilt sensing using a homodyne quadrature interferometric translational sensor
Future gravitational wave observation in space will demand improvement in the sensitivity of the local sensor for the drag-free control. This paper presents the proposal, design, and demonstration of a new laser interferometric sensor named Quadrature Interferometric Metrology of Translation and Tilt (QUIMETT) for the drag-free local sensor. QUIMETT enables simultaneous measurements of both translational displacement and tilts of a reflective object with a single interferometer package. QUIMETT offers a characteristic feature where the sensitivity to tilt is independent of the interference condition while maintaining the ability to measure the translational displacement for a range greater than the laser wavelength. The tilt-sensing function has been demonstrated in a prototype experiment. The tilt sensitivity remained unchanged in different interference conditions and stayed at 10 nrad Hz − 1 / 2 at 0.1 Hz.
- 14 May 2025
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 42 (10) , 105007
Demonstration of tilt sensing using a homodyne quadrature interferometric translational sensor
Future gravitational wave observation in space will demand improvement in the sensitivity of the local sensor for the drag-free control. This paper presents the proposal, design, and demonstration of a new laser interferometric sensor named Quadrature Interferometric Metrology of Translation and Tilt (QUIMETT) for the drag-free local sensor. QUIMETT enables simultaneous measurements of both translational displacement and tilts of a reflective object with a single interferometer package. QUIMETT offers a characteristic feature where the sensitivity to tilt is independent of the interference condition while maintaining the ability to measure the translational displacement for a range greater than the laser wavelength. The tilt-sensing function has been demonstrated in a prototype experiment. The tilt sensitivity remained unchanged in different interference conditions and stayed at 10 nrad Hz − 1 / 2 at 0.1 Hz.
- 15 April 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (8)
Cross-correlated force measurement for thermal noise reduction in torsion pendulum
- 15 April 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (8)
Cross-correlated force measurement for thermal noise reduction in torsion pendulum
- 13 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (11) , 19372-19387
Quantum-enhanced optical phase-insensitive heterodyne detection beyond 3-dB noise penalty of image band
Optical phase-insensitive heterodyne (beat-note) detection, which measures the relative phase of two beams at different frequencies through their interference, is a key sensing technology for various spatial/temporal measurements, such as frequency measurements in optical frequency combs. However, its sensitivity is limited not only by shot noise from the signal frequency band but also by the extra shot noise from an image band, known as the 3-dB noise penalty. Here, we propose a method to remove shot noise from all these bands using squeezed light. We also demonstrate beyond-3-dB noise reduction experimentally, confirming that our method actually reduces shot noise from both the signal and extra bands simultaneously. Our work should boost the sensitivity of various spatial/temporal measurements beyond the current limitations.
- 13 May 2024
- Published by Optica Publishing Group in Optics Express
- Vol. 32 (11) , 19372-19387
Quantum-enhanced optical phase-insensitive heterodyne detection beyond 3-dB noise penalty of image band
Optical phase-insensitive heterodyne (beat-note) detection, which measures the relative phase of two beams at different frequencies through their interference, is a key sensing technology for various spatial/temporal measurements, such as frequency measurements in optical frequency combs. However, its sensitivity is limited not only by shot noise from the signal frequency band but also by the extra shot noise from an image band, known as the 3-dB noise penalty. Here, we propose a method to remove shot noise from all these bands using squeezed light. We also demonstrate beyond-3-dB noise reduction experimentally, confirming that our method actually reduces shot noise from both the signal and extra bands simultaneously. Our work should boost the sensitivity of various spatial/temporal measurements beyond the current limitations.
- 10 January 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 109 (2) , 022003
Experimental demonstration of back-linked Fabry-Perot interferometer for a space gravitational wave antenna
The back-linked Fabry-Perot interferometer (BLFPI) is an interferometer topology proposed for space gravitational wave antennas with the use of intersatellite Fabry-Perot interferometers. The BLFPI offers simultaneous and independent control over all interferometer length degrees of freedom by controlling the laser frequencies. Therefore, BLFPI does not require an active control system for the physical lengths of the intersatellite Fabry-Perot interferometers. To achieve a high sensitivity, the implementation must rely on an offline signal process for subtracting laser frequency noises. However, the subtraction has not been experimentally verified to date. This paper reports a demonstration of the frequency noise subtraction in the frequency band of 100 Hz–50 kHz, including the cavity pole frequency, using Fabry-Perot cavities with a length of 46 cm. The highest reduction ratio of approximately 200 was achieved. This marks the first experimental verification of the critical function in the BLFPI.
- 10 January 2024
- Published by American Physical Society (APS) in Physical Review D
- Vol. 109 (2) , 022003
Experimental demonstration of back-linked Fabry-Perot interferometer for a space gravitational wave antenna
The back-linked Fabry-Perot interferometer (BLFPI) is an interferometer topology proposed for space gravitational wave antennas with the use of intersatellite Fabry-Perot interferometers. The BLFPI offers simultaneous and independent control over all interferometer length degrees of freedom by controlling the laser frequencies. Therefore, BLFPI does not require an active control system for the physical lengths of the intersatellite Fabry-Perot interferometers. To achieve a high sensitivity, the implementation must rely on an offline signal process for subtracting laser frequency noises. However, the subtraction has not been experimentally verified to date. This paper reports a demonstration of the frequency noise subtraction in the frequency band of 100 Hz–50 kHz, including the cavity pole frequency, using Fabry-Perot cavities with a length of 46 cm. The highest reduction ratio of approximately 200 was achieved. This marks the first experimental verification of the critical function in the BLFPI.
- 18 September 2019
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 36 (20) , 205006
Systematic calibration error requirements for gravitational-wave detectors via the Cramér–Rao bound
Gravitational-wave (GW) laser interferometers such as Advanced LIGO (The LIGO Scientific Collaboration 2015 Class. Quantum Grav . 32 074001) transduce spacetime strain into optical power fluctuation. Converting this optical power fluctuation back into an estimated spacetime strain requires a calibration process that accounts for both the interferometer’s optomechanical response and the feedback control loop used to control the interferometer test masses. Systematic errors in the calibration parameters lead to systematic errors in the GW strain estimate, and hence to systematic errors in the astrophysical parameter estimates in a particular GW signal. In this work we examine this effect for a GW signal similar to GW150914, both for a low-power detector operation similar to the first and second Advanced LIGO observing runs and for a higher-power operation with detuned signal extraction. We set requirements on the accuracy of the calibration such that the astrophysical parameter estimation is limited by errors introduced by random detector noise, rather than calibration systematics. We also examine the impact of systematic calibration errors on the possible detection of a massive graviton.
- 18 September 2019
- Published by IOP Publishing in Classical and Quantum Gravity
- Vol. 36 (20) , 205006
Systematic calibration error requirements for gravitational-wave detectors via the Cramér–Rao bound
Gravitational-wave (GW) laser interferometers such as Advanced LIGO (The LIGO Scientific Collaboration 2015 Class. Quantum Grav . 32 074001) transduce spacetime strain into optical power fluctuation. Converting this optical power fluctuation back into an estimated spacetime strain requires a calibration process that accounts for both the interferometer’s optomechanical response and the feedback control loop used to control the interferometer test masses. Systematic errors in the calibration parameters lead to systematic errors in the GW strain estimate, and hence to systematic errors in the astrophysical parameter estimates in a particular GW signal. In this work we examine this effect for a GW signal similar to GW150914, both for a low-power detector operation similar to the first and second Advanced LIGO observing runs and for a higher-power operation with detuned signal extraction. We set requirements on the accuracy of the calibration such that the astrophysical parameter estimation is limited by errors introduced by random detector noise, rather than calibration systematics. We also examine the impact of systematic calibration errors on the possible detection of a massive graviton.
- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 114503
The Advanced LIGO photon calibrators
The two interferometers of the Laser Interferometry Gravitational-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generation (Advanced) LIGO detectors to gravitational waves are systems based on radiation pressure and referred to as photon calibrators. These systems, which were completely redesigned for Advanced LIGO, include several significant upgrades that enable them to meet the calibration requirements of second-generation gravitational wave detectors in the new era of gravitational-wave astronomy. We report on the design, implementation, and operation of these Advanced LIGO photon calibrators that are currently providing fiducial displacements on the order of with accuracy and precision of better than 1%.- 1 November 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 114503
The Advanced LIGO photon calibrators
The two interferometers of the Laser Interferometry Gravitational-wave Observatory (LIGO) recently detected gravitational waves from the mergers of binary black hole systems. Accurate calibration of the output of these detectors was crucial for the observation of these events and the extraction of parameters of the sources. The principal tools used to calibrate the responses of the second-generation (Advanced) LIGO detectors to gravitational waves are systems based on radiation pressure and referred to as photon calibrators. These systems, which were completely redesigned for Advanced LIGO, include several significant upgrades that enable them to meet the calibration requirements of second-generation gravitational wave detectors in the new era of gravitational-wave astronomy. We report on the design, implementation, and operation of these Advanced LIGO photon calibrators that are currently providing fiducial displacements on the order of with accuracy and precision of better than 1%.