Shinsuke Narumi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shinsuke Narumi has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
Yasuo Terayama
Department of Neurology and Gerontology, Iwate Medical University School of Medicine, Morioka, Japan
11 shared publicationsMakoto Sasaki
Division of Ultrahigh Field MRI, Institute for Biomedical Sciences, Iwate Medical University School of Medicine, Morioka, Japan
9 shared publicationsHideki Ohba
Department of Neurology and Gerontology, Iwate Medical University, Japan
7 shared publications- Makoto Sasaki
Iwate Tohoku Medical Megabank Organization, Disaster Reconstruction Center, Iwate Medical University, Yahaba, Japan
6 shared publications Kohsuke Kudo
Division of Ultrahigh Field MRI, Institute for Biomedical Sciences, Iwate Medical University, Morioka, Japan
5 shared publicationsKuniaki Ogasawara
Department of Neurosurgery, Iwate Medical University, Iwate, Japan
4 shared publications
Latest Publications
- Open Access
- 1 May 2017
- Published by Elsevier in Atherosclerosis
- Vol. 260, 87-93
Preoperative cervical carotid artery contrast-enhanced ultrasound findings are associated with development of microembolic signals on transcranial Doppler during carotid exposure in endarterectomy
- 1 May 2017
- Published by Elsevier in Atherosclerosis
- Vol. 260, 87-93
Open AccessPreoperative cervical carotid artery contrast-enhanced ultrasound findings are associated with development of microembolic signals on transcranial Doppler during carotid exposure in endarterectomy
- 1 February 2017
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 26 (2) , 273-279
T1-Weighted Magnetic Resonance Carotid Plaque Imaging: a Comparison between Conventional and Fast Spin-Echo Techniques
- 1 February 2017
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 26 (2) , 273-279
T1-Weighted Magnetic Resonance Carotid Plaque Imaging: a Comparison between Conventional and Fast Spin-Echo Techniques
- Open Access
- 27 October 2016
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 17 (11) , 1791
Preoperative 3D FSE T1-Weighted MR Plaque Imaging for Severely Stenotic Cervical ICA: Accuracy of Predicting Emboli during Carotid Endarterectomy
The aim of the present study was to determine whether preoperative three-dimensional (3D) fast spin-echo (FSE) T1-weighted magnetic resonance (MR) plaque imaging for severely stenotic cervical carotid arteries could accurately predict the development of artery-to-artery emboli during exposure of the carotid arteries in carotid endarterectomy (CEA). Seventy-five patients underwent preoperative MR plaque imaging and CEA under transcranial Doppler ultrasonography of the ipsilateral middle cerebral artery. On reformatted axial MR image slices showing the maximum plaque occupation rate (POR) and maximum plaque intensity for each patient, the contrast ratio (CR) was calculated by dividing the internal carotid artery plaque signal intensity by the sternocleidomastoid muscle signal intensity. For all patients, the area under the receiver operating characteristic curve (AUC)—used to discriminate between the presence and absence of microembolic signals—was significantly greater for the CR on the axial image with maximum plaque intensity (CRmax intensity) (0.941) than for that with the maximum POR (0.885) (p < 0.05). For 32 patients in whom both the maximum POR and the maximum plaque density were identified, the AUCs for the CR were 1.000. Preoperative 3D FSE T1-weighted MR plaque imaging accurately predicts the development of artery-to-artery emboli during exposure of the carotid arteries in CEA.
- 27 October 2016
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 17 (11) , 1791
Open AccessPreoperative 3D FSE T1-Weighted MR Plaque Imaging for Severely Stenotic Cervical ICA: Accuracy of Predicting Emboli during Carotid Endarterectomy
The aim of the present study was to determine whether preoperative three-dimensional (3D) fast spin-echo (FSE) T1-weighted magnetic resonance (MR) plaque imaging for severely stenotic cervical carotid arteries could accurately predict the development of artery-to-artery emboli during exposure of the carotid arteries in carotid endarterectomy (CEA). Seventy-five patients underwent preoperative MR plaque imaging and CEA under transcranial Doppler ultrasonography of the ipsilateral middle cerebral artery. On reformatted axial MR image slices showing the maximum plaque occupation rate (POR) and maximum plaque intensity for each patient, the contrast ratio (CR) was calculated by dividing the internal carotid artery plaque signal intensity by the sternocleidomastoid muscle signal intensity. For all patients, the area under the receiver operating characteristic curve (AUC)—used to discriminate between the presence and absence of microembolic signals—was significantly greater for the CR on the axial image with maximum plaque intensity (CRmax intensity) (0.941) than for that with the maximum POR (0.885) (p < 0.05). For 32 patients in whom both the maximum POR and the maximum plaque density were identified, the AUCs for the CR were 1.000. Preoperative 3D FSE T1-weighted MR plaque imaging accurately predicts the development of artery-to-artery emboli during exposure of the carotid arteries in CEA.
- Open Access
- 4 February 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (6) , 1146-1154
Optimal MR Plaque Imaging for Cervical Carotid Artery Stenosis in Predicting the Development of Microembolic Signals during Exposure of Carotid Arteries in Endarterectomy: Comparison of 4 T1-Weighted Imaging Techniques
BACKGROUND AND PURPOSE: Preoperative identification of plaque vulnerability may allow improved risk stratification for patients considered for carotid endarterectomy. The present study aimed to determine which plaque imaging technique, cardiac-gated black-blood fast spin-echo, magnetization-prepared rapid acquisition of gradient echo, source image of 3D time-of-flight MR angiography, or noncardiac-gated spin-echo, most accurately predicts development of microembolic signals during exposure of carotid arteries in carotid endarterectomy. MATERIALS AND METHODS: Eighty patients with ICA stenosis (≥70%) underwent the 4 sequences of preoperative MR plaque imaging of the affected carotid bifurcation and then carotid endarterectomy under transcranial Doppler monitoring of microembolic signals in the ipsilateral middle cerebral artery. The contrast ratio of the carotid plaque was calculated by dividing plaque signal intensity by sternocleidomastoid muscle signal intensity. RESULTS: Microembolic signals during exposure of carotid arteries were detected in 23 patients (29%), 3 of whom developed new neurologic deficits postoperatively. Those deficits remained at 24 hours after surgery in only 1 patient. The area under the receiver operating characteristic curve to discriminate between the presence and absence of microembolic signals during exposure of the carotid arteries was significantly greater with nongated spin-echo than with black-blood fast spin-echo (difference between areas, 0.258; P < .0001), MPRAGE (difference between areas, 0.106; P = .0023), or source image of 3D time-of-flight MR angiography (difference between areas, 0.128; P = .0010). Negative binomial regression showed that in the 23 patients with microembolic signals, the contrast ratio was associated with the number of microembolic signals only in nongated spin-echo (risk ratio, 1.36; 95% confidence interval, 1.01–1.97; P < .001). CONCLUSIONS: Nongated spin-echo may predict the development of microembolic signals during exposure of the carotid arteries in carotid endarterectomy more accurately than other MR plaque imaging techniques.
- 4 February 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 37 (6) , 1146-1154
Open AccessOptimal MR Plaque Imaging for Cervical Carotid Artery Stenosis in Predicting the Development of Microembolic Signals during Exposure of Carotid Arteries in Endarterectomy: Comparison of 4 T1-Weighted Imaging Techniques
BACKGROUND AND PURPOSE: Preoperative identification of plaque vulnerability may allow improved risk stratification for patients considered for carotid endarterectomy. The present study aimed to determine which plaque imaging technique, cardiac-gated black-blood fast spin-echo, magnetization-prepared rapid acquisition of gradient echo, source image of 3D time-of-flight MR angiography, or noncardiac-gated spin-echo, most accurately predicts development of microembolic signals during exposure of carotid arteries in carotid endarterectomy. MATERIALS AND METHODS: Eighty patients with ICA stenosis (≥70%) underwent the 4 sequences of preoperative MR plaque imaging of the affected carotid bifurcation and then carotid endarterectomy under transcranial Doppler monitoring of microembolic signals in the ipsilateral middle cerebral artery. The contrast ratio of the carotid plaque was calculated by dividing plaque signal intensity by sternocleidomastoid muscle signal intensity. RESULTS: Microembolic signals during exposure of carotid arteries were detected in 23 patients (29%), 3 of whom developed new neurologic deficits postoperatively. Those deficits remained at 24 hours after surgery in only 1 patient. The area under the receiver operating characteristic curve to discriminate between the presence and absence of microembolic signals during exposure of the carotid arteries was significantly greater with nongated spin-echo than with black-blood fast spin-echo (difference between areas, 0.258; P < .0001), MPRAGE (difference between areas, 0.106; P = .0023), or source image of 3D time-of-flight MR angiography (difference between areas, 0.128; P = .0010). Negative binomial regression showed that in the 23 patients with microembolic signals, the contrast ratio was associated with the number of microembolic signals only in nongated spin-echo (risk ratio, 1.36; 95% confidence interval, 1.01–1.97; P < .001). CONCLUSIONS: Nongated spin-echo may predict the development of microembolic signals during exposure of the carotid arteries in carotid endarterectomy more accurately than other MR plaque imaging techniques.
- Open Access
- 1 February 2016
- Published by Wiley in Neurology and Clinical Neuroscience
- Vol. 4 (3) , 115-117
Case of McLeod syndrome with a novel genetic mutation
McLeod syndrome is a rare neuroacanthocytosis caused by mutation of the XK gene. Acanthocytes in peripheral blood, systemic chorea, neuropathy, myopathy and increased serum levels of creatine kinase are observed in this syndrome, and mental manifestations and cardiomyopathy can also arise as complications. Various mutations in the XK gene have been reported, but the pathological condition in McLeod syndrome is unclear because of a lack of reports. We report a 64‐year‐old man with McLeod syndrome who showed increased levels of creatine kinase, and muscle atrophy and weakness in bilateral lower limbs. Peripheral blood smear showed numerous acanthocytes, and reduced levels of Kell antigen and the absence of XK protein suggested McLeod syndrome. Genetic analysis showed a mutation of c.del724_729TGTAGinsGGTCCTCTTTACC on exon 3 of the XK gene. To our knowledge, this is a novel genetic mutation in the XK gene.
- 1 February 2016
- Published by Wiley in Neurology and Clinical Neuroscience
- Vol. 4 (3) , 115-117
Open AccessCase of McLeod syndrome with a novel genetic mutation
McLeod syndrome is a rare neuroacanthocytosis caused by mutation of the XK gene. Acanthocytes in peripheral blood, systemic chorea, neuropathy, myopathy and increased serum levels of creatine kinase are observed in this syndrome, and mental manifestations and cardiomyopathy can also arise as complications. Various mutations in the XK gene have been reported, but the pathological condition in McLeod syndrome is unclear because of a lack of reports. We report a 64‐year‐old man with McLeod syndrome who showed increased levels of creatine kinase, and muscle atrophy and weakness in bilateral lower limbs. Peripheral blood smear showed numerous acanthocytes, and reduced levels of Kell antigen and the absence of XK protein suggested McLeod syndrome. Genetic analysis showed a mutation of c.del724_729TGTAGinsGGTCCTCTTTACC on exon 3 of the XK gene. To our knowledge, this is a novel genetic mutation in the XK gene.
- Open Access
- 8 January 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 36 (4) , 751-756
Carotid Plaque Characterization Using 3D T1-Weighted MR Imaging with Histopathologic Validation: A Comparison with 2D Technique
BACKGROUND AND PURPOSE: 3D FSE T1WI has recently been used for carotid plaque imaging, given the potential advantages in contrast and spatial resolutions. However, its diagnostic performance remains unclear. Hence, we compared the ability of this technique to readily assess plaque characteristics with that of conventional images and validated the results with histologic classification. MATERIALS AND METHODS: We prospectively examined 34 patients with carotid stenosis who underwent carotid endarterectomy by using 1.5T scanners and obtained 3D-FSE T1WI and 2D spin-echo T1WI scans. After generating reformatted images obtained from the 3D-FSE T1-weighted images, we calculated the contrast ratios for the plaques and the adjacent muscles and compared these findings with the pathologic classifications. RESULTS: Carotid plaques were histologically classified as types VII, VIII, IV–V, or VI. With 3D-FSE T1WI, the range of contrast ratios for each classification was the following: 0.94–0.97 (median, 0.95), 0.95–1.29 (median, 1.10), 1.33–1.54 (median, 1.42), and 1.53–2.12 (median, 1.80), respectively. With 2D imaging, the range of contrast ratios for each classification was the following: 0.79–1.02 (median, 0.90), 0.88–1.19 (median, 1.01), 1.17–1.46 (median, 1.23), and 1.55–2.51 (median, 2.07), respectively. Results were significantly different among the 4 groups (P < .001). Sensitivity and specificity for discriminating vulnerable plaques (IV–VI) from stable plaques (VII, VIII) were both 100% for the 3D technique and 100% and 91%, respectively, for the 2D technique. CONCLUSIONS: 3D-FSE T1WI accurately characterizes intraplaque components of the carotid artery, with excellent sensitivity and specificity compared with those of 2D-T1WI.
- 8 January 2015
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 36 (4) , 751-756
Open AccessCarotid Plaque Characterization Using 3D T1-Weighted MR Imaging with Histopathologic Validation: A Comparison with 2D Technique
BACKGROUND AND PURPOSE: 3D FSE T1WI has recently been used for carotid plaque imaging, given the potential advantages in contrast and spatial resolutions. However, its diagnostic performance remains unclear. Hence, we compared the ability of this technique to readily assess plaque characteristics with that of conventional images and validated the results with histologic classification. MATERIALS AND METHODS: We prospectively examined 34 patients with carotid stenosis who underwent carotid endarterectomy by using 1.5T scanners and obtained 3D-FSE T1WI and 2D spin-echo T1WI scans. After generating reformatted images obtained from the 3D-FSE T1-weighted images, we calculated the contrast ratios for the plaques and the adjacent muscles and compared these findings with the pathologic classifications. RESULTS: Carotid plaques were histologically classified as types VII, VIII, IV–V, or VI. With 3D-FSE T1WI, the range of contrast ratios for each classification was the following: 0.94–0.97 (median, 0.95), 0.95–1.29 (median, 1.10), 1.33–1.54 (median, 1.42), and 1.53–2.12 (median, 1.80), respectively. With 2D imaging, the range of contrast ratios for each classification was the following: 0.79–1.02 (median, 0.90), 0.88–1.19 (median, 1.01), 1.17–1.46 (median, 1.23), and 1.55–2.51 (median, 2.07), respectively. Results were significantly different among the 4 groups (P < .001). Sensitivity and specificity for discriminating vulnerable plaques (IV–VI) from stable plaques (VII, VIII) were both 100% for the 3D technique and 100% and 91%, respectively, for the 2D technique. CONCLUSIONS: 3D-FSE T1WI accurately characterizes intraplaque components of the carotid artery, with excellent sensitivity and specificity compared with those of 2D-T1WI.
- 1 October 2014
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 23 (9) , 2419-2424
Detection of Vessel Wall Lesions in Spontaneous Symptomatic Vertebrobasilar Artery Dissection Using T1-weighted 3-dimensional Imaging
- 1 October 2014
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 23 (9) , 2419-2424
Detection of Vessel Wall Lesions in Spontaneous Symptomatic Vertebrobasilar Artery Dissection Using T1-weighted 3-dimensional Imaging
- 1 October 2014
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 23 (9) , 2425-2430
Carotid Plaque Characteristics on Magnetic Resonance Plaque Imaging Following Long-term Cilostazol Therapy
- 1 October 2014
- Published by Elsevier in Journal of Stroke and Cerebrovascular Diseases
- Vol. 23 (9) , 2425-2430
Carotid Plaque Characteristics on Magnetic Resonance Plaque Imaging Following Long-term Cilostazol Therapy