Ravi C. Dara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ravi C. Dara has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Aseem Kumar Tiwari
Department of Transfusion Medicine, Medanta-The Medicity, Gurugram, Haryana, India
8 shared publications - Geet Aggarwal
Department of Transfusion Medicine, Medanta-The Medicity, Gurgaon, India
5 shared publications Vimarsh Raina
Laboratory Services and Transfusion Medicine, Medanta-The Medicity, Sector-38, Gurgaon 122001, India
4 shared publicationsDinesh Arora
Department of Transfusion Medicine, Medanta-The Medicity, Gurgaon, India
3 shared publications- Gunjan Bhardwaj
Department of Transfusion Medicine, BLK-Max Super Speciality Hospital, New Delhi, India
3 shared publications Prashant Pandey
Department of Transfusion Medicine, Jaypee Hospital, Sector 128, Noida 201301, India
3 shared publications
Latest Publications
- 17 August 2022
- Published by Springer Nature in Indian Journal of Hematology and Blood Transfusion
- Vol. 39 (2) , 300-307
Comparison of Two Different Serological Viral Marker Testing Assays for Screening of Apheresis Donors: Which Assay Provides Optimum Safety for Transfusion?
While whole blood testing has evolved over the years, viral marker testing for plateletpheresis donors is still performed by Rapid Diagnostic Tests (RDT). Aim of this study was to compare diagnostic accuracy of RDT and Chemiluminescence Immunoassay (CLIA) in serological testing for HBsAg, anti-HCV and anti-HIV antibodies. A prospective, analytical study was conducted in the department of Transfusion Medicine at a tertiary healthcare center in India between September 2016 and August 2018. Samples were simultaneously tested by CLIA, RDT and a confirmatory test. Sensitivity, specificity, negative and positive predictive values and mean time taken to report results were calculated. A total of 102 (1.48%) of the 6883 samples were found to be reactive by either or both the assays. A total of 74 (1.08%) samples were HBsAg reactive, 23 (0.33%) were reactive for anti-HCV antibodies and 5 (0.07%) were reactive for anti-HIV I and II antibodies. A combined sero-prevalence of 1.05% (72) was observed; 0.78% (54) for HBsAg, 0.26% (18) for anti-HCV antibodies and none for anti-HIV I and II antibodies. Four (3.85%) reactive samples were missed by RDT and therefore sensitivity of RDT was quite less as compared to CLIA. RDT and CLIA both were found to have a statistically significant shorter turnaround time than confirmatory tests. There is increasing need to develop a safe donor screening strategy for plateletpheresis. CLIA offers an excellent alterative to RDT for viral marker testing in terms of sensitivity.
- 17 August 2022
- Published by Springer Nature in Indian Journal of Hematology and Blood Transfusion
- Vol. 39 (2) , 300-307
Comparison of Two Different Serological Viral Marker Testing Assays for Screening of Apheresis Donors: Which Assay Provides Optimum Safety for Transfusion?
While whole blood testing has evolved over the years, viral marker testing for plateletpheresis donors is still performed by Rapid Diagnostic Tests (RDT). Aim of this study was to compare diagnostic accuracy of RDT and Chemiluminescence Immunoassay (CLIA) in serological testing for HBsAg, anti-HCV and anti-HIV antibodies. A prospective, analytical study was conducted in the department of Transfusion Medicine at a tertiary healthcare center in India between September 2016 and August 2018. Samples were simultaneously tested by CLIA, RDT and a confirmatory test. Sensitivity, specificity, negative and positive predictive values and mean time taken to report results were calculated. A total of 102 (1.48%) of the 6883 samples were found to be reactive by either or both the assays. A total of 74 (1.08%) samples were HBsAg reactive, 23 (0.33%) were reactive for anti-HCV antibodies and 5 (0.07%) were reactive for anti-HIV I and II antibodies. A combined sero-prevalence of 1.05% (72) was observed; 0.78% (54) for HBsAg, 0.26% (18) for anti-HCV antibodies and none for anti-HIV I and II antibodies. Four (3.85%) reactive samples were missed by RDT and therefore sensitivity of RDT was quite less as compared to CLIA. RDT and CLIA both were found to have a statistically significant shorter turnaround time than confirmatory tests. There is increasing need to develop a safe donor screening strategy for plateletpheresis. CLIA offers an excellent alterative to RDT for viral marker testing in terms of sensitivity.
- Open Access
- 1 January 2020
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 14 (2) , 187-191
Severe drug-induced immune hemolysis due to ceftriaxone
Drug-induced immune hemolytic anemia (DIIHA) is a rare condition that results primarily due to drug-induced antibodies, either drug dependent or drug independent. For its diagnosis, specialized immunohematology laboratory is often required for performing complex serological tests. The exact incidence of DIIHA is not known, but as per data published by Garratty, the incidence of DIIHA is estimated to be one in million population.[1] There are many drugs which are implicated in causing DIIHA ranging from antimicrobials, antineoplastics to anti-inflammatory drugs. Among antimicrobials, cephalosporins are commonly reported to cause hemolytic anemia.[2] In this report, we present a life-threatening hemolytic reaction to cephalosporin (ceftriaxone) in a 15-year-old child, which was diagnosed and managed in a timely manner. Our patient was suddenly deteriorated after two doses of intravenous ceftriaxone, with increase in pallor, fatigue, and frank hematuria. Repeat laboratory investigations showed signs of hemolysis, presence of schistocytes, raised lactic dehydrogenase, and indirect bilirubin. Reticulocyte count was 3.4%. Direct antiglobulin test was strong positive (4+) with IgG and C3d positive. Testing for drug-dependent antibody confirmed the presence of ceftriaxone-dependent antibody. Drug was stopped immediately. There was a rapid improvement in patient's general condition after discontinuation of drug. Laboratory parameters were improved after 48 h, and the patient was stable with no further drop in hemoglobin and hemolytic episodes. We suggest the need for proper immunohematological services to diagnose and solve such complex cases promptly.
- 1 January 2020
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 14 (2) , 187-191
Open AccessSevere drug-induced immune hemolysis due to ceftriaxone
Drug-induced immune hemolytic anemia (DIIHA) is a rare condition that results primarily due to drug-induced antibodies, either drug dependent or drug independent. For its diagnosis, specialized immunohematology laboratory is often required for performing complex serological tests. The exact incidence of DIIHA is not known, but as per data published by Garratty, the incidence of DIIHA is estimated to be one in million population.[1] There are many drugs which are implicated in causing DIIHA ranging from antimicrobials, antineoplastics to anti-inflammatory drugs. Among antimicrobials, cephalosporins are commonly reported to cause hemolytic anemia.[2] In this report, we present a life-threatening hemolytic reaction to cephalosporin (ceftriaxone) in a 15-year-old child, which was diagnosed and managed in a timely manner. Our patient was suddenly deteriorated after two doses of intravenous ceftriaxone, with increase in pallor, fatigue, and frank hematuria. Repeat laboratory investigations showed signs of hemolysis, presence of schistocytes, raised lactic dehydrogenase, and indirect bilirubin. Reticulocyte count was 3.4%. Direct antiglobulin test was strong positive (4+) with IgG and C3d positive. Testing for drug-dependent antibody confirmed the presence of ceftriaxone-dependent antibody. Drug was stopped immediately. There was a rapid improvement in patient's general condition after discontinuation of drug. Laboratory parameters were improved after 48 h, and the patient was stable with no further drop in hemoglobin and hemolytic episodes. We suggest the need for proper immunohematological services to diagnose and solve such complex cases promptly.
- 1 June 2017
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 56 (3) , 367-370
Co-infection of blood borne viruses in blood donors: A cross-sectional study from North India
- 1 June 2017
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 56 (3) , 367-370
Co-infection of blood borne viruses in blood donors: A cross-sectional study from North India
- 1 April 2016
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 54 (2) , 242-247
Confirmation and follow up of initial “NAT yields”: Prospective study from a tertiary healthcare center in India
- 1 April 2016
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 54 (2) , 242-247
Confirmation and follow up of initial “NAT yields”: Prospective study from a tertiary healthcare center in India
- 7 April 2015
- Published by Wiley in Journal of Clinical Apheresis
- Vol. 31 (1) , 16-21
Change in therapeutic apheresis practices: Role of continuing medical education (CME)
- 7 April 2015
- Published by Wiley in Journal of Clinical Apheresis
- Vol. 31 (1) , 16-21
Change in therapeutic apheresis practices: Role of continuing medical education (CME)
- Open Access
- 1 January 2015
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 9 (1) , 94-7
Approach to a case of multiple irregular red cell antibodies in a liver transplant recipient: Need for developing competence
Liver transplant procedure acts as a challenge for transfusion services in terms of specialized blood components, serologic problems, and immunologic effects of transfusion. Red cell alloimmunization in patients awaiting a liver transplant complicate the process by undue delay or unavailability of compatible red blood cell units. Compatible blood units can be provided by well-equipped immunohematology laboratory, which has expertise in resolving these serological problems. This report illustrates resolution of a case with multiple alloantibodies using standard techniques, particularly rare antisera. Our case re-emphasizes the need for universal antibody screening in all patients as part of pretransfusion testing, which helps to identify atypical antibodies and plan for appropriate transfusion support well in time. We recommend that the centers, especially the ones that perform complex procedures like solid organ transplants and hematological transplants should have the necessary immunohematological reagents including rare antisera to resolve complex cases of multiple antibodies as illustrated in this case.
- 1 January 2015
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 9 (1) , 94-7
Open AccessApproach to a case of multiple irregular red cell antibodies in a liver transplant recipient: Need for developing competence
Liver transplant procedure acts as a challenge for transfusion services in terms of specialized blood components, serologic problems, and immunologic effects of transfusion. Red cell alloimmunization in patients awaiting a liver transplant complicate the process by undue delay or unavailability of compatible red blood cell units. Compatible blood units can be provided by well-equipped immunohematology laboratory, which has expertise in resolving these serological problems. This report illustrates resolution of a case with multiple alloantibodies using standard techniques, particularly rare antisera. Our case re-emphasizes the need for universal antibody screening in all patients as part of pretransfusion testing, which helps to identify atypical antibodies and plan for appropriate transfusion support well in time. We recommend that the centers, especially the ones that perform complex procedures like solid organ transplants and hematological transplants should have the necessary immunohematological reagents including rare antisera to resolve complex cases of multiple antibodies as illustrated in this case.
- Open Access
- 1 January 2015
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 9 (1) , 65-9
Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital
Context: Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS) on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. Aims: This study was designed to evaluate the performance of newly introduced VITROS ® syphilis Treponema pallidum agglutination (TPA) assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. Materials and Methods: A total of 108 random blood units collected from the donors (both voluntary and replacement donors) and 28 known syphilis sero-reactive samples stored at −20°C, were used to evaluate the performance of VITROS ® syphilis TPA assay based on enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. Results: VITROS ® syphilis TPA showed 100% sensitivity and specificity with precision (20 days study) of ® syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.
- 1 January 2015
- Published by Medknow in Asian Journal of Transfusion Science
- Vol. 9 (1) , 65-9
Open AccessEvaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital
Context: Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS) on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. Aims: This study was designed to evaluate the performance of newly introduced VITROS ® syphilis Treponema pallidum agglutination (TPA) assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. Materials and Methods: A total of 108 random blood units collected from the donors (both voluntary and replacement donors) and 28 known syphilis sero-reactive samples stored at −20°C, were used to evaluate the performance of VITROS ® syphilis TPA assay based on enhanced chemiluminescence assay on VITROS ® ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. Results: VITROS ® syphilis TPA showed 100% sensitivity and specificity with precision (20 days study) of ® syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.
- 1 October 2014
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 51 (2) , 197-202
Allo-antibody identification: a software approach!
- 1 October 2014
- Published by Elsevier in Transfusion and Apheresis Science
- Vol. 51 (2) , 197-202
Allo-antibody identification: a software approach!
- Open Access
- 12 September 2014
- Published by Springer Nature in Transplantation Research
- Vol. 3 (1) , 17
Cascade plasmapheresis (CP) as a preconditioning regime in ABO-incompatible live related donor liver transplants (ABOi-LDLT)
ABO-incompatible live donor liver transplant (ABOi-LDLT) is being widely done to bridge the gap of demand and supply of organs. Different desensitization regimes are being used to reduce titer of blood group antibodies for successful transplant and accommodation of graft. The authors used cascade plasmapheresis (CP) to bring down titer of naturally occurring blood group antibody to 16 or lower.
- 12 September 2014
- Published by Springer Nature in Transplantation Research
- Vol. 3 (1) , 17
Open AccessCascade plasmapheresis (CP) as a preconditioning regime in ABO-incompatible live related donor liver transplants (ABOi-LDLT)
ABO-incompatible live donor liver transplant (ABOi-LDLT) is being widely done to bridge the gap of demand and supply of organs. Different desensitization regimes are being used to reduce titer of blood group antibodies for successful transplant and accommodation of graft. The authors used cascade plasmapheresis (CP) to bring down titer of naturally occurring blood group antibody to 16 or lower.