Miguel Louro
Research Subjects
Miguel Louro has a total of 92 co-authors. Here are the top co-authors by number of shared publications:
Bernardo Almeida
Protection and Automation, EDP Distribuição , Lisbon, Portugal
3 shared publications- Luis Antonio Fialho Marcelino Ferreira
Department of Electrical Engineering and Computers, Instituto Superior Técnico, 1049-001 Lisbon, Portugal
3 shared publications C. Cura
2 shared publications- José Pombo
IT—Instituto de Telecomunicações, University of Beira Interior, 6201-001 Covilhã, Portugal
2 shared publications - Maria Rosario Alves Calado
IT—Instituto de Telecomunicações, University of Beira Interior, 6201-001 Covilhã, Portugal
2 shared publications - Silvio Jose Pinto Simoes Mariano
IT—Instituto de Telecomunicações, University of Beira Interior, 6201-001 Covilhã, Portugal
2 shared publications
Latest Publications
- Open Access
- 28 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (11) , 5442
A Review of Particle Swarm Optimization Control Parameters for Maximum Power Point Tracking Under Different Conditions
The increasing importance of photovoltaic (PV) systems in the context of the energy transition, together with the need to improve their efficiency, has driven the adoption and development of intelligent and advanced maximum power point tracking (MPPT) techniques. Among these approaches, the Particle Swarm Optimization (PSO) algorithm stands out due to its simplicity, ease of implementation, low number of control parameters, robustness, and fast convergence capability, making it widely applied in modern MPPT systems. However, the performance of PSO in MPPT applications depends on the appropriate selection of both algorithm control parameters and implementation/configurations parameters. The control parameters include the cognitive (C1) and social (C2) learning factors, as well as the inertia factor (w), which directly influence swarm dynamics and the balance between exploration and exploitation mechanisms, that is, between global and local search. On the other hand, configuration parameters such as the number of particles and the initialization strategy affect the initial population diversity, the convergence speed toward the maximum power point, and the computational cost of the algorithm, defining the trade-off between speed and accuracy. Despite the extensive research in this field, there is still no clear consensus regarding the most suitable PSO parameter configuration for MPPT applications. This paper presents a statistical analysis of PSO parameter selection in MPPT applications, identifying the most frequently adopted parameter configurations and trends reported in the literature. The findings provide useful guidelines for researchers to select the PSO parameters according to different operating conditions, particularly under partial shading and irradiance variations. From a sustainability perspective, improving MPPT performance contributes to maximizing PV energy harvesting, reducing energy losses, and enhancing the reliability of PV systems, thereby supporting the transition toward more sustainable energy generation.
- 28 May 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (11) , 5442
Open AccessA Review of Particle Swarm Optimization Control Parameters for Maximum Power Point Tracking Under Different Conditions
The increasing importance of photovoltaic (PV) systems in the context of the energy transition, together with the need to improve their efficiency, has driven the adoption and development of intelligent and advanced maximum power point tracking (MPPT) techniques. Among these approaches, the Particle Swarm Optimization (PSO) algorithm stands out due to its simplicity, ease of implementation, low number of control parameters, robustness, and fast convergence capability, making it widely applied in modern MPPT systems. However, the performance of PSO in MPPT applications depends on the appropriate selection of both algorithm control parameters and implementation/configurations parameters. The control parameters include the cognitive (C1) and social (C2) learning factors, as well as the inertia factor (w), which directly influence swarm dynamics and the balance between exploration and exploitation mechanisms, that is, between global and local search. On the other hand, configuration parameters such as the number of particles and the initialization strategy affect the initial population diversity, the convergence speed toward the maximum power point, and the computational cost of the algorithm, defining the trade-off between speed and accuracy. Despite the extensive research in this field, there is still no clear consensus regarding the most suitable PSO parameter configuration for MPPT applications. This paper presents a statistical analysis of PSO parameter selection in MPPT applications, identifying the most frequently adopted parameter configurations and trends reported in the literature. The findings provide useful guidelines for researchers to select the PSO parameters according to different operating conditions, particularly under partial shading and irradiance variations. From a sustainability perspective, improving MPPT performance contributes to maximizing PV energy harvesting, reducing energy losses, and enhancing the reliability of PV systems, thereby supporting the transition toward more sustainable energy generation.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-11
Energy Management Strategy for Renewable Communities providing Flexibility Services
This study addresses a flexible energy management strategy for a hybrid renewable energy system, focusing on photovoltaic, battery, and hydrogen storage systems. Three scenarios were analyzed to explore more sustainable and self-sufficient approaches: (1) a conventional microgrid, (2) a Renewable Energy Community, and (3) a community providing grid flexibility. The results show that it is possible to reduce dependence on conventional electricity grids, emphasizing the importance of sharing energy within a community. It is also possible to use the various resources to provide flexibility services to grid operators, thus receiving adequate compensation while facilitating the connection of more renewable energy to the existing grid. The study offers insights into system efficiency and a smaller grid dependency while considering flexibility services, as well as significant contributions to the sizing of generation and storage facilities for self-consumption and management of renewable energies.
- 19 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-11
Energy Management Strategy for Renewable Communities providing Flexibility Services
This study addresses a flexible energy management strategy for a hybrid renewable energy system, focusing on photovoltaic, battery, and hydrogen storage systems. Three scenarios were analyzed to explore more sustainable and self-sufficient approaches: (1) a conventional microgrid, (2) a Renewable Energy Community, and (3) a community providing grid flexibility. The results show that it is possible to reduce dependence on conventional electricity grids, emphasizing the importance of sharing energy within a community. It is also possible to use the various resources to provide flexibility services to grid operators, thus receiving adequate compensation while facilitating the connection of more renewable energy to the existing grid. The study offers insights into system efficiency and a smaller grid dependency while considering flexibility services, as well as significant contributions to the sizing of generation and storage facilities for self-consumption and management of renewable energies.
- 4 July 2023
- Published by Institution of Engineering and Technology (IET) in IET Conference Proceedings
- Vol. 2023 (6) , 3245-3249
E-redes adopt new monometallic technology and predictive algorithm to minimize and predict LV neutral loss failures detection
One of the most common failures in low voltage (LV) grids with a strong impact on customers' sites is neutral loss. In an extreme situation, the neutral loss can lead to phase-to-neutral voltages reaching values of 173%Vn for highly unbalanced systems, which can cause client equipment failures and, subsequently, compensation costs paid by the Distribution System Operator (DSO). To tackle this challenge, since the beginning of 2022, E-REDES has been developing a methodology where data from nearly 4.6 million Smart Meters in mainland Portugal is continuously gathered, structured and analyzed in an algorithm to flag LV circuits with potential intermittent neutral losses proactively. In addition to developing this algorithm, the results were integrated into the operations management system to automatically dispatch the identified cases to field teams, guaranteeing the shortest possible time response and preventing a potential total neutral loss and all the related complaints, Quality of Service (QoS) decrease and compensation costs. The results indicated that the main cause of this type of incident in the underground network is the untimely separation of the aluminium-copper connection from the LV bimetallic terminals. The lack of information on terminals manufacturers and the characterization of failures in the maintenance systems leads to the impossibility of developing a time-to-fail estimate and, consequently, makes it difficult to define preventive intervention criteria for the replacement of these materials before failures occur. Thus, E-REDES changed its purchasing options for monometallic technology. Monometallic terminals are already widely used by E-REDES in the medium voltage (MV) grid and were also the solution adopted on the LV grid by several utilities to mitigate similar issues with bimetallic terminals. This paper intends to present the approach, main conclusions, and the benefits of proactively developing an algorithm to identify LV circuits with potential latent neutral losses and define the criteria for replacing bimetallic terminals before failures occur. Furthermore, the methodology E-REDES is presented to guarantee that the technology to be adopted assures adequate performance to the network and the tracking methodology that will prevent a similar lack of information if recurrent faults occur with a specific material. By the end of 2022, 69 situations have been detected and preemptively solved. About 3100 customers were downstream of the failure point, and these preemptive actions avoided internal damage to most of their electrical installations. Based on historical data regarding average numbers of complaints and compensations per incident, these situations are estimated to have avoided a maximum of 560k€ in compensation costs for the DSO.
- 4 July 2023
- Published by Institution of Engineering and Technology (IET) in IET Conference Proceedings
- Vol. 2023 (6) , 3245-3249
E-redes adopt new monometallic technology and predictive algorithm to minimize and predict LV neutral loss failures detection
One of the most common failures in low voltage (LV) grids with a strong impact on customers' sites is neutral loss. In an extreme situation, the neutral loss can lead to phase-to-neutral voltages reaching values of 173%Vn for highly unbalanced systems, which can cause client equipment failures and, subsequently, compensation costs paid by the Distribution System Operator (DSO). To tackle this challenge, since the beginning of 2022, E-REDES has been developing a methodology where data from nearly 4.6 million Smart Meters in mainland Portugal is continuously gathered, structured and analyzed in an algorithm to flag LV circuits with potential intermittent neutral losses proactively. In addition to developing this algorithm, the results were integrated into the operations management system to automatically dispatch the identified cases to field teams, guaranteeing the shortest possible time response and preventing a potential total neutral loss and all the related complaints, Quality of Service (QoS) decrease and compensation costs. The results indicated that the main cause of this type of incident in the underground network is the untimely separation of the aluminium-copper connection from the LV bimetallic terminals. The lack of information on terminals manufacturers and the characterization of failures in the maintenance systems leads to the impossibility of developing a time-to-fail estimate and, consequently, makes it difficult to define preventive intervention criteria for the replacement of these materials before failures occur. Thus, E-REDES changed its purchasing options for monometallic technology. Monometallic terminals are already widely used by E-REDES in the medium voltage (MV) grid and were also the solution adopted on the LV grid by several utilities to mitigate similar issues with bimetallic terminals. This paper intends to present the approach, main conclusions, and the benefits of proactively developing an algorithm to identify LV circuits with potential latent neutral losses and define the criteria for replacing bimetallic terminals before failures occur. Furthermore, the methodology E-REDES is presented to guarantee that the technology to be adopted assures adequate performance to the network and the tracking methodology that will prevent a similar lack of information if recurrent faults occur with a specific material. By the end of 2022, 69 situations have been detected and preemptively solved. About 3100 customers were downstream of the failure point, and these preemptive actions avoided internal damage to most of their electrical installations. Based on historical data regarding average numbers of complaints and compensations per incident, these situations are estimated to have avoided a maximum of 560k€ in compensation costs for the DSO.
- Open Access
Estimation of Underground MV Network Failure Types by Applying Machine Learning Methods to Indirect Observations
Electrical utilities performance is measured by various indicators, of which the most important are very dependent on the interruption time after a failure in the network has occurred, such as SAIDI. Therefore, they are constantly looking for new techniques to decrease the fault location and repair times. A possibility to innovate in this field is to estimate the failed network component when a fault occurs. This paper presents the conclusion of an analysis carried out by the authors with the aim to estimate failure types of underground MV networks based on observable indirect variables. The variables needed to carry out the analysis must be available shortly after the failure occurrence, which is facilitated by a smart-grid infrastructure, to allow for a quick estimation. This paper uses the groundwork already carried out by the authors on ambient variables, historical variables, and disturbance recordings to design an estimator to predict between four MV cable network failure types. The paper presents relevant analyses on the design and performance of various machine learning classification algorithms for estimation of the types of MV cable network failures using real-world data. Optimization of performance was carried out, resulting in an estimator with an overall 68% accuracy rate. Accuracy rates of 94% for cable failure, 63% for excavations, and 79% secondary busbar failures were achieved; as for cable joints, the accuracy was poor due to the difficulty to identify a feature that can be used to separate this failure type from cable failures. Future work to improve that accuracy is discussed.
Open AccessEstimation of Underground MV Network Failure Types by Applying Machine Learning Methods to Indirect Observations
Electrical utilities performance is measured by various indicators, of which the most important are very dependent on the interruption time after a failure in the network has occurred, such as SAIDI. Therefore, they are constantly looking for new techniques to decrease the fault location and repair times. A possibility to innovate in this field is to estimate the failed network component when a fault occurs. This paper presents the conclusion of an analysis carried out by the authors with the aim to estimate failure types of underground MV networks based on observable indirect variables. The variables needed to carry out the analysis must be available shortly after the failure occurrence, which is facilitated by a smart-grid infrastructure, to allow for a quick estimation. This paper uses the groundwork already carried out by the authors on ambient variables, historical variables, and disturbance recordings to design an estimator to predict between four MV cable network failure types. The paper presents relevant analyses on the design and performance of various machine learning classification algorithms for estimation of the types of MV cable network failures using real-world data. Optimization of performance was carried out, resulting in an estimator with an overall 68% accuracy rate. Accuracy rates of 94% for cable failure, 63% for excavations, and 79% secondary busbar failures were achieved; as for cable joints, the accuracy was poor due to the difficulty to identify a feature that can be used to separate this failure type from cable failures. Future work to improve that accuracy is discussed.
- Open Access
- 12 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 73758-73773
Data-Driven Anomaly Detection and Event Log Profiling of SCADA Alarms
Network human operators’ decision-making during grid outages requires significant attention and the ability to perceive real-time feedback from multiple information sources to minimize the number of control actions required to restore service, while maintaining the system and people safety. Data-driven event and alarm management have the potential to reduce human operator cognitive burden. However, the high complexity of events, the data semantics, and the large variety of equipment and technologies are key barriers for the application of Artificial Intelligence (AI) to raw SCADA data. In this context, this paper proposes a methodology to convert a large volume of alarm events into data mining terminology, creating the conditions for the application of modern AI techniques to alarm data. Moreover, this work also proposes two novel data-driven applications based on SCADA data: (i) identification of anomalous behaviors regarding the performance of the protection relays of primary substations, during circuit breaker tripping alarms in High Voltage (HV) and Medium Voltage (MV) lines; (ii) unsupervised learning to cluster similar events in HV line panels, classify new event logs based on the obtained clusters and membership grade with a control parameter that helps to identify rare events. Important aspects associated with data handling and pre-processing are also covered. The results for real data from a Distribution System Operator (DSO) showed: (i) that the proposed method can detect unexpected relay pickup events, e.g., one substation with nearly 41% of the circuit breaker alarms had an ‘atypical’ event in their context (revealed an overlooked problem on the electrification of a protection relay); (ii) capability to automatically detect and group issues into specific clusters, e.g., SF6 low-pressure alarms and blocks with abnormal profiles caused by event time-delay problems.
- 12 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 10, 73758-73773
Open AccessData-Driven Anomaly Detection and Event Log Profiling of SCADA Alarms
Network human operators’ decision-making during grid outages requires significant attention and the ability to perceive real-time feedback from multiple information sources to minimize the number of control actions required to restore service, while maintaining the system and people safety. Data-driven event and alarm management have the potential to reduce human operator cognitive burden. However, the high complexity of events, the data semantics, and the large variety of equipment and technologies are key barriers for the application of Artificial Intelligence (AI) to raw SCADA data. In this context, this paper proposes a methodology to convert a large volume of alarm events into data mining terminology, creating the conditions for the application of modern AI techniques to alarm data. Moreover, this work also proposes two novel data-driven applications based on SCADA data: (i) identification of anomalous behaviors regarding the performance of the protection relays of primary substations, during circuit breaker tripping alarms in High Voltage (HV) and Medium Voltage (MV) lines; (ii) unsupervised learning to cluster similar events in HV line panels, classify new event logs based on the obtained clusters and membership grade with a control parameter that helps to identify rare events. Important aspects associated with data handling and pre-processing are also covered. The results for real data from a Distribution System Operator (DSO) showed: (i) that the proposed method can detect unexpected relay pickup events, e.g., one substation with nearly 41% of the circuit breaker alarms had an ‘atypical’ event in their context (revealed an overlooked problem on the electrification of a protection relay); (ii) capability to automatically detect and group issues into specific clusters, e.g., SF6 low-pressure alarms and blocks with abnormal profiles caused by event time-delay problems.
- 13 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3679-3687
MV Underground Distribution Network Failures and Correlation to Ambient Variables
Electrical utilities are continuously searching for new ways to cut costs and effectively increase the quality of service being supplied to their clients, which is closely related to the number of failures and the time it takes to locate and repair them. A helpful input for this continuing effort would be to have an estimate of the type of failure when it occurs. The analysis presented in this paper is part of an effort being carried out to estimate failure types based on an analysis of observable indirect variables. These indirect variables must be readily available after the failure detection, through a Smart Grid infrastructure, to enable a future application to carry out the estimation. This paper lays the groundwork on ambient and historical variables that display a relationship with various types of MV cable network failures. The paper presents relevant data and analyses the relationship between the various failure types and indirect variables, such as date and time, loading, historical data, daily rainfall, accumulated rainfall, dew point and ambient temperature. Relationships between indirect variables and failure types are established to help identifying the most relevant variables for the design of the estimator.
- 13 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (5) , 3679-3687
MV Underground Distribution Network Failures and Correlation to Ambient Variables
Electrical utilities are continuously searching for new ways to cut costs and effectively increase the quality of service being supplied to their clients, which is closely related to the number of failures and the time it takes to locate and repair them. A helpful input for this continuing effort would be to have an estimate of the type of failure when it occurs. The analysis presented in this paper is part of an effort being carried out to estimate failure types based on an analysis of observable indirect variables. These indirect variables must be readily available after the failure detection, through a Smart Grid infrastructure, to enable a future application to carry out the estimation. This paper lays the groundwork on ambient and historical variables that display a relationship with various types of MV cable network failures. The paper presents relevant data and analyses the relationship between the various failure types and indirect variables, such as date and time, loading, historical data, daily rainfall, accumulated rainfall, dew point and ambient temperature. Relationships between indirect variables and failure types are established to help identifying the most relevant variables for the design of the estimator.
- Open Access
Underground MV Network Failures’ Waveform Characteristics—An Investigation
The authors seek to investigate the characteristics of outage-causing faults that can be observed in a short time frame after their occurrence: waveform of the voltages and currents. The aim is to identify which characteristics can be used to estimate the failure type immediately after its occurrence. This paper lays the groundwork to determine which features display a stronger relation to four failure types with the aim of using this information in a later work, not presented in this paper, aimed at designing a reliable failure type estimator from readily available data. This paper focuses on the most common failures of the underground cable MV networks in Portugal: cable insulation; cable joint; secondary substation busbar; and excavation-motivated failures. A set of 206 waveform records of real underground MV network failures was available for analysis. After investigating the waveforms, the authors identified seven waveform characteristics which can be used for failure type estimation. Fault type characteristics can be used to distinguish secondary substation failures from the remaining failure types. Fault evolution does not yield relevant information. Fault self-extinction phenomenon was not observed in excavation-caused failures. There are differences for self-extinction characteristics between secondary substation busbar failures and the cable insulation and joint failures. Fault inception instant and arc voltage are two characteristics which are shown to have a promising merit to the identification process of failure types. Finally, fault intra-cycle repetitive extinction results have been found to be very similar for cable insulation failures and joint failures, but otherwise different regarding the remaining failure types.
Open AccessUnderground MV Network Failures’ Waveform Characteristics—An Investigation
The authors seek to investigate the characteristics of outage-causing faults that can be observed in a short time frame after their occurrence: waveform of the voltages and currents. The aim is to identify which characteristics can be used to estimate the failure type immediately after its occurrence. This paper lays the groundwork to determine which features display a stronger relation to four failure types with the aim of using this information in a later work, not presented in this paper, aimed at designing a reliable failure type estimator from readily available data. This paper focuses on the most common failures of the underground cable MV networks in Portugal: cable insulation; cable joint; secondary substation busbar; and excavation-motivated failures. A set of 206 waveform records of real underground MV network failures was available for analysis. After investigating the waveforms, the authors identified seven waveform characteristics which can be used for failure type estimation. Fault type characteristics can be used to distinguish secondary substation failures from the remaining failure types. Fault evolution does not yield relevant information. Fault self-extinction phenomenon was not observed in excavation-caused failures. There are differences for self-extinction characteristics between secondary substation busbar failures and the cable insulation and joint failures. Fault inception instant and arc voltage are two characteristics which are shown to have a promising merit to the identification process of failure types. Finally, fault intra-cycle repetitive extinction results have been found to be very similar for cable insulation failures and joint failures, but otherwise different regarding the remaining failure types.
- Open Access
- 1 January 2020
- Published by Institution of Engineering and Technology (IET) in CIRED - Open Access Proceedings Journal
- Vol. 2020 (1) , 794-796
Reactive power provision using distribution grid resources: flexibility hub use case
With the energy transition at sight and the EU renewable energy source integration ambition, the EU-SysFlex project aims at defining a set of advancements in the electric system that drives us towards that direction. With the increasing decentralisation and granularity of the generation facilities, local generation will gain a determinant role in the provision of future local and global systems services. This study presents an overview of a framework for a local market for reactive power control that will be implemented and demonstrated under a real scenario in a Portuguese demo site. The demonstration includes a set of capacitor banks of the distribution system operator (DSO) and two wind farms of a wind power generation operator. This local reactive power market consists of a close to real-time continuous intraday local market managed by the DSO, with 15 min delivery time to increase temporal granularity, and with 7 h delivery horizons with complex bids to allow more flexible assets operation. Market agents can also correct future previously scheduled positions by participating themselves as sellers or buyers of capacitive or inductive reactive power, providing a more flexible framework.
- 1 January 2020
- Published by Institution of Engineering and Technology (IET) in CIRED - Open Access Proceedings Journal
- Vol. 2020 (1) , 794-796
Open AccessReactive power provision using distribution grid resources: flexibility hub use case
With the energy transition at sight and the EU renewable energy source integration ambition, the EU-SysFlex project aims at defining a set of advancements in the electric system that drives us towards that direction. With the increasing decentralisation and granularity of the generation facilities, local generation will gain a determinant role in the provision of future local and global systems services. This study presents an overview of a framework for a local market for reactive power control that will be implemented and demonstrated under a real scenario in a Portuguese demo site. The demonstration includes a set of capacitor banks of the distribution system operator (DSO) and two wind farms of a wind power generation operator. This local reactive power market consists of a close to real-time continuous intraday local market managed by the DSO, with 15 min delivery time to increase temporal granularity, and with 7 h delivery horizons with complex bids to allow more flexible assets operation. Market agents can also correct future previously scheduled positions by participating themselves as sellers or buyers of capacitive or inductive reactive power, providing a more flexible framework.
- Open Access
Reactive Power Management Considering Stochastic Optimization under the Portuguese Reactive Power Policy Applied to DER in Distribution Networks
Challenges in the coordination between the transmission system operator (TSO) and the distribution system operator (DSO) have risen continuously with the integration of distributed energy resources (DER). These technologies have the possibility to provide reactive power support for system operators. Considering the Portuguese reactive power policy as an example of the regulatory framework, this paper proposes a methodology for proactive reactive power management of the DSO using the renewable energy sources (RES) considering forecast uncertainty available in the distribution system. The proposed method applies a stochastic sequential alternative current (AC)-optimal power flow (SOPF) that returns trustworthy solutions for the DSO and optimizes the use of reactive power between the DSO and DER. The method is validated using a 37-bus distribution network considering real data. Results proved that the method improves the reactive power management by taking advantage of the full capabilities of the DER and by reducing the injection of reactive power by the TSO in the distribution network and, therefore, reducing losses.
Open AccessReactive Power Management Considering Stochastic Optimization under the Portuguese Reactive Power Policy Applied to DER in Distribution Networks
Challenges in the coordination between the transmission system operator (TSO) and the distribution system operator (DSO) have risen continuously with the integration of distributed energy resources (DER). These technologies have the possibility to provide reactive power support for system operators. Considering the Portuguese reactive power policy as an example of the regulatory framework, this paper proposes a methodology for proactive reactive power management of the DSO using the renewable energy sources (RES) considering forecast uncertainty available in the distribution system. The proposed method applies a stochastic sequential alternative current (AC)-optimal power flow (SOPF) that returns trustworthy solutions for the DSO and optimizes the use of reactive power between the DSO and DER. The method is validated using a 37-bus distribution network considering real data. Results proved that the method improves the reactive power management by taking advantage of the full capabilities of the DER and by reducing the injection of reactive power by the TSO in the distribution network and, therefore, reducing losses.
- Open Access
- 1 October 2017
- Published by Institution of Engineering and Technology (IET) in CIRED - Open Access Proceedings Journal
- Vol. 2017 (1) , 1223-1226
Improving smart SCADA data analysis with alternative data sources
As the implementation of the smart grids increases, so does the quantity and variety of Supervisory Control and Data Acquisition (SCADA) events. The experience of handling this large amount of data has given a new role to the DSO as a Data Manager. With this in mind, EDP Distribuição (EDPD) started developing big data handling algorithms that transform this huge amount of data in information [1]. Yet as the potential to enhance the information coming from SCADA is huge, EDPD is also starting to introduce data from sources other than SCADA in the smart event analysis programmes. The data from these new sources is then cross-references with the output of smart event analysis algorithms to provide some extra information to help us identity the faults probable causes. Smart SCADA data analysis tools as the one presented here benefits grid operation as it simplifies dispatching centres activity. They also come in handy to identify problems such as circuit breakers failures or protection relays malfunctions in a much easier and automatic way, thus, helping to assess the reliability of the protection system with direct impact on grid operation. Furthermore, the algorithms provide information that can be used to identify trends and patterns.
- 1 October 2017
- Published by Institution of Engineering and Technology (IET) in CIRED - Open Access Proceedings Journal
- Vol. 2017 (1) , 1223-1226
Open AccessImproving smart SCADA data analysis with alternative data sources
As the implementation of the smart grids increases, so does the quantity and variety of Supervisory Control and Data Acquisition (SCADA) events. The experience of handling this large amount of data has given a new role to the DSO as a Data Manager. With this in mind, EDP Distribuição (EDPD) started developing big data handling algorithms that transform this huge amount of data in information [1]. Yet as the potential to enhance the information coming from SCADA is huge, EDPD is also starting to introduce data from sources other than SCADA in the smart event analysis programmes. The data from these new sources is then cross-references with the output of smart event analysis algorithms to provide some extra information to help us identity the faults probable causes. Smart SCADA data analysis tools as the one presented here benefits grid operation as it simplifies dispatching centres activity. They also come in handy to identify problems such as circuit breakers failures or protection relays malfunctions in a much easier and automatic way, thus, helping to assess the reliability of the protection system with direct impact on grid operation. Furthermore, the algorithms provide information that can be used to identify trends and patterns.