Muhammed Mustafa Alikhan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Muhammed Mustafa Alikhan has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Dustin Carlson
Division of Gastroenterology and Hepatology, Feinberg School of Medicine Northwestern University Chicago Illinois USA
3 shared publications John E. Pandolfino
Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Department of Medicine, Division of Gastroenterology and Hepatology, Feinberg School of Medicine Northwestern University Chicago Illinois USA
2 shared publications- Wenjun Kou
Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Department of Medicine, Division of Gastroenterology and Hepatology, Feinberg School of Medicine Northwestern University Chicago Illinois USA
2 shared publications Aidan D. Smires
Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Department of Medicine, Division of Gastroenterology and Hepatology Feinberg School of Medicine, Northwestern University Chicago Illinois USA
1 shared publication- Aidan D. Smires
Kenneth C. Griffin Esophageal Center of Northwestern Medicine, Department of Medicine, Division of Gastroenterology and Hepatology, Feinberg School of Medicine Northwestern University Chicago Illinois USA
1 shared publication - Alberto Rubio-Tapia
Celiac Disease Program, Division of Gastroenterology, Hepatology, and Nutrition, Digestive Disease Institute, Cleveland Clinic, Cleveland, Ohio, USA
1 shared publication
Latest Publications
- Open Access
- 30 October 2026
- Published by The Korean Society of Neurogastroenterology and Motility in Journal of Neurogastroenterology and Motility
- Vol. 32 (4) , 702-704
The Physiologic Response to Functional Lumen Imaging Probe Panometry: Lessons Learned From Simultaneous High-Resolution Manometry
Muhammed M. Alikhan, John E. Pandolfino, Ofer Z. Fass, Meagan Branch, Monica Tapia, and Dustin A. Carlson. J Neurogastroenterol Motil 2026;32:702-4. https://doi.org/10.5056/jnm26071
- 30 October 2026
- Published by The Korean Society of Neurogastroenterology and Motility in Journal of Neurogastroenterology and Motility
- Vol. 32 (4) , 702-704
Open AccessThe Physiologic Response to Functional Lumen Imaging Probe Panometry: Lessons Learned From Simultaneous High-Resolution Manometry
Muhammed M. Alikhan, John E. Pandolfino, Ofer Z. Fass, Meagan Branch, Monica Tapia, and Dustin A. Carlson. J Neurogastroenterol Motil 2026;32:702-4. https://doi.org/10.5056/jnm26071
- Open Access
- 7 October 2026
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 38 (10)
Biomechanical Assessment During High‐Resolution Impedance Manometry Enhances Characterization of Inconclusive Esophagogastric Junction Outflow Obstruction
Background: Esophagogastric junction outflow obstruction (EGJOO) identified on high‐resolution manometry (HRM) remains a clinically heterogeneous and inconclusive finding. Additional complementary testing with functional lumen imaging probe (FLIP) or timed barium esophagram (TBE) is recommended to confirm clinically relevant obstruction. We aimed to assess the association of novel Four‐Dimensional (4D) HRM metrics against FLIP and TBE outcomes among symptomatic patients with inconclusive EGJOO on HRM. Methods: Adult patients with inconclusive HRM‐EGJOO who completed corresponding FLIP and TBE studies were identified for inclusion in a cross‐sectional, retrospective study. Primary 4D HRM metrics of EGJ opening, EGJ distensibility index (4D EGJ‐DI), and 4D maximum EGJ diameter were analyzed relative to reference outcomes defined by FLIP and esophagram. Results: Among 123 patients (mean age 59 years; 60% female), 4D EGJ‐DI and 4D maximum EGJ diameter differed significantly across FLIP and TBE outcome categories (all p < 0.01). Lower 4D EGJ‐DI and lower 4D maximum EGJ diameter were associated with reduced EGJ opening on FLIP and abnormal retention on esophagram. There were 0 patients with normal EGJ opening on FLIP that had 4D maximum EGJ diameter < 8.0 mm and 0 patients with reduced EGJ opening on FLIP that had a 4D EGJ‐DI > 2.2 mm 2 /mmHg and 4D maximum EGJ diameter > 10.2 mm. Conclusions: By integrating biomechanical assessment of EGJ opening with conventional pressure metrics, 4D HRM provides complementary physiologic information for evaluating esophageal motor function. This additional information may improve characterization of patients with inconclusive EGJOO.
- 7 October 2026
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 38 (10)
Open AccessBiomechanical Assessment During High‐Resolution Impedance Manometry Enhances Characterization of Inconclusive Esophagogastric Junction Outflow Obstruction
Background: Esophagogastric junction outflow obstruction (EGJOO) identified on high‐resolution manometry (HRM) remains a clinically heterogeneous and inconclusive finding. Additional complementary testing with functional lumen imaging probe (FLIP) or timed barium esophagram (TBE) is recommended to confirm clinically relevant obstruction. We aimed to assess the association of novel Four‐Dimensional (4D) HRM metrics against FLIP and TBE outcomes among symptomatic patients with inconclusive EGJOO on HRM. Methods: Adult patients with inconclusive HRM‐EGJOO who completed corresponding FLIP and TBE studies were identified for inclusion in a cross‐sectional, retrospective study. Primary 4D HRM metrics of EGJ opening, EGJ distensibility index (4D EGJ‐DI), and 4D maximum EGJ diameter were analyzed relative to reference outcomes defined by FLIP and esophagram. Results: Among 123 patients (mean age 59 years; 60% female), 4D EGJ‐DI and 4D maximum EGJ diameter differed significantly across FLIP and TBE outcome categories (all p < 0.01). Lower 4D EGJ‐DI and lower 4D maximum EGJ diameter were associated with reduced EGJ opening on FLIP and abnormal retention on esophagram. There were 0 patients with normal EGJ opening on FLIP that had 4D maximum EGJ diameter < 8.0 mm and 0 patients with reduced EGJ opening on FLIP that had a 4D EGJ‐DI > 2.2 mm 2 /mmHg and 4D maximum EGJ diameter > 10.2 mm. Conclusions: By integrating biomechanical assessment of EGJ opening with conventional pressure metrics, 4D HRM provides complementary physiologic information for evaluating esophageal motor function. This additional information may improve characterization of patients with inconclusive EGJOO.
- Open Access
- 12 April 2026
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 38 (4) , e70320
Addressing Gaps in the Chicago Classification Version 4.0: Defining an Optimal Intrabolus Pressure Measurement on Esophageal Manometry
Background: Intrabolus pressure (IBP) reflects the pressure within the esophageal lumen during bolus transit and serves as a physiologic marker of outflow resistance at the esophagogastric junction (EGJ). The lack of a standardized or validated method to measure IBP is a critical limitation for interpreting high resolution manometry (HRM) and identification of clinically relevant EGJ outflow obstruction (EGJOO). Methods: Three distinct cohorts, “Controls”, Normal motility”, and “conclusive EGJOO” were selected from a prospectively enrolled cohort of adult patients. All patients had at least undergone HRM with impedance (HRIM), and functional lumen impedance probe (FLIP) testing. 4D HRM analysis was performed blinded to clinical characteristics. 4D HRM IBP results were assessed on a per‐swallow and also on a per‐patient level. Receiver operating curve (ROCs) to assess each metrics prediction of conclusive EGJOO vs. not EGJOO (normal motility and controls) were utilized for the per‐swallow analysis. Key Results: 33 controls, 35 normal motility, and 15 conclusive EGJOO patients were included. Swallow level analysis was conducted on 156 swallows, 165 swallows, and 61 swallows from each group, respectively. Per‐swallow analysis demonstrated differences between conclusive EGJOO, normal motility, and controls for all ten IBP measures (P‐values < 0.001), with greater IBP measures in conclusive EGJOO than in normal motility and controls. The 1 s max IBP had the greatest AUROC. Conclusions & Inferences: Standardized measurement of IBP using an optimized method (1‐s max IBP) within the 4D‐HRM framework with impedance‐confirmed bolus tracking and phase‐specific measures represents a physiologically grounded and clinically meaningful advance in HRIM interpretation.
- 12 April 2026
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 38 (4) , e70320
Open AccessAddressing Gaps in the Chicago Classification Version 4.0: Defining an Optimal Intrabolus Pressure Measurement on Esophageal Manometry
Background: Intrabolus pressure (IBP) reflects the pressure within the esophageal lumen during bolus transit and serves as a physiologic marker of outflow resistance at the esophagogastric junction (EGJ). The lack of a standardized or validated method to measure IBP is a critical limitation for interpreting high resolution manometry (HRM) and identification of clinically relevant EGJ outflow obstruction (EGJOO). Methods: Three distinct cohorts, “Controls”, Normal motility”, and “conclusive EGJOO” were selected from a prospectively enrolled cohort of adult patients. All patients had at least undergone HRM with impedance (HRIM), and functional lumen impedance probe (FLIP) testing. 4D HRM analysis was performed blinded to clinical characteristics. 4D HRM IBP results were assessed on a per‐swallow and also on a per‐patient level. Receiver operating curve (ROCs) to assess each metrics prediction of conclusive EGJOO vs. not EGJOO (normal motility and controls) were utilized for the per‐swallow analysis. Key Results: 33 controls, 35 normal motility, and 15 conclusive EGJOO patients were included. Swallow level analysis was conducted on 156 swallows, 165 swallows, and 61 swallows from each group, respectively. Per‐swallow analysis demonstrated differences between conclusive EGJOO, normal motility, and controls for all ten IBP measures (P‐values < 0.001), with greater IBP measures in conclusive EGJOO than in normal motility and controls. The 1 s max IBP had the greatest AUROC. Conclusions & Inferences: Standardized measurement of IBP using an optimized method (1‐s max IBP) within the 4D‐HRM framework with impedance‐confirmed bolus tracking and phase‐specific measures represents a physiologically grounded and clinically meaningful advance in HRIM interpretation.
- Top Cited PapersOpen Access
- 1 March 2019
- Published by Elsevier in Gastroenterology
- Vol. 156 (4) , 1041-1051.e4
Role of Bile Acids and GLP-1 in Mediating the Metabolic Improvements of Bariatric Surgery
- 1 March 2019
- Published by Elsevier in Gastroenterology
- Vol. 156 (4) , 1041-1051.e4
Top Cited PapersOpen AccessRole of Bile Acids and GLP-1 in Mediating the Metabolic Improvements of Bariatric Surgery