Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Neus Jornet Martínez has a total of 52 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electrospray preparation of Fe-PMMA films for one-drop analysis of thiocyanate a tobacco biomarker as a case study

    by Lucía Benavente-Cobo, Rosa Herráez-Hernández, Pilar Campíns-Falcó, Neus Jornet-Martínez

  • Open Access

    A Dexamethasone-Loaded Compact Intraocular Lens for Cataract Surgery: Validation in an in Vivo Pilot Study

    by Cristina Peris Martínez, Cristina Artigas Felipe, José María Artigas Verde, Mª Josefa Luque Cobija, Aloma Mayordomo Febrer, Mª Carmen García Domene, María López Murcia, María José Roig Revert, Cristina Martínez Gil, Mariola Penadés Fons, et al.

    Intraocular lens (IOL) implantation is widely performed, but poor adherence to traditional eye drop therapy and low drug bioavailability increase the risk of postoperative inflammation and infection. Although many drug delivery strategies have been proposed, in vivo evidence is limited, and scalability remains a key challenge for clinical use. In this study, we introduce a compact dexamethasone (DXM)-loaded IOL fabricated through a simple, low-cost, one-step process by embedding DXM within a biocompatible polydimethylsiloxane (PDMS)-based polymer matrix. The DXM-loaded IOL was evaluated in in vitro assays and in seven New Zealand–California White rabbits undergoing cataract surgery, with the DXM-loaded IOL implanted in the right eye and a nonloaded IOL used as a control in the left eye. Aqueous humor samples were collected at different time points to assess prostaglandin E2 (PGE2) levels as an inflammatory biomarker, as well as DXM release. Drug release ranged from 31% to 99% (2.1–8.5 μg), and PGE2 levels were lower in eyes implanted with the DXM-loaded IOL than in control eyes, indicating reduced inflammation. In conclusion, we present a preclinical validated prototype of a dual-function IOL that maintains visual performance and reduces postoperative inflammation.

  • Open Access

    New Green and Sustainable Tool for Assessing Nitrite and Nitrate Amounts in a Variety of Environmental Waters

    by H. R. Robles-Jimarez, N. Jornet-Martínez, P. Campíns-Falcó

    This paper aims to provide improved selectivity and sensitivity with a short analysis time of about 10 min and low residues for quantitation of nitrite and nitrate in waters by liquid chromatography. Ion-pair formation and ion exchange retention mechanisms were considered. The optimized option was in-tube solid phase microextraction (IT-SPME) by means of a silica capillary of 14 cm length and 0.32 mm id, coupled online with a capillary anion exchange analytical column (Inertsil AX 150 × 0.5 mm id, 5 µm) and the use of their native absorbance. Precision of the retention times expressed as % relative standard deviation (RSD) were R = 5.8 min) and nitrate (tR = 10.5 min). Well, river, channel, lake, sea, tap and bottled waters and several matrices of a drinking water treatment plant were analysed, and no matrix effect was observed for all of them. Inorganic anions and several organic acids were tested as possible interferences and suitable selectivity was obtained. Precision expressed as % relative standard deviation (RSD) was between 0.9 and 3%. Low detection limits of 0.9 and 9 μg/L for nitrite and nitrate were obtained, respectively, and low residue generation near 100 µL per run was also achieved.


  • Open Access

    A Colorimetric Method for the Rapid Estimation of the Total Cannabinoid Content in Cannabis Samples

    by Neus Jornet-Martínez, Josep Biosca-Micó, Pilar Campíns-Falcó, Rosa Herráez-Hernández

    A colorimetric method for the estimation of the total content of cannabinoids in cannabis samples is proposed. The assay is based on the reaction of these compounds with the reagent Fast Blue B (FBB), which has been immobilized into polydimethylsiloxane (PDMS). The reaction and detection conditions have been established according to the results obtained for the individual cannabinoids Δ9-tetrahydrocannabidiol (THC), cannabidiol (CBD), and cannabinol (CBN), as well as for ethanolic extracts obtained from cannabis samples after ultrasonication. In contact with the extract and under basic conditions, the reagent diffuses from the PDMS device, producing a red-brown solution. The absorbances measured at 500 nm after only 1 min of exposure to the FBB/PDMS composites led to responses proportional to the amounts of the cannabinoids in the reaction media. Those absorbances have been then transformed in total cannabinoid content using CBD as a reference compound. The potential utility of the proposed conditions has been tested by analyzing different cannabis samples. The selectivity towards other plants and drugs has been also evaluated. The present method is proposed as a simple and rapid alternative to chromatographic methods for the estimation of the total content of cannabinoids.


  • Open Access

    A Colorimetric Membrane-Based Sensor with Improved Selectivity towards Amphetamine

    by Neus Jornet-Martínez, Pilar Campíns-Falcó, Rosa Herráez-Hernández

    Due to their simplicity, speed and low cost, chemical spot tests are increasingly demanded for the presumptive identification of illicit drugs in a variety of contexts such as point-of-care assistance or prosecution of drug trafficking. However, most of the colorimetric reactions used in these tests are, at best, drug class selective. Therefore, the development of tests based on chemical reactions with improved discrimination power is of great interest. In this work, we propose a new colorimetric assay for amphetamine (AMP) based on its reaction with solutions of alkaline gold bromide to form an insoluble yellow–orange derivative. The resulting suspensions are then filtered onto nylon membranes and the precipitate collected is used for the visual identification of AMP. The measurement of the absorbance of the membranes by diffuse reflectance spectroscopy also allows the quantification of AMP in a simple and rapid way, as demonstrated for different synthetic and drug street samples. On the basis of the results obtained, it was concluded that the proposed procedure is highly selective towards AMP, as this compound could be easily differentiated from other common drugs such as methamphetamine (MET), ephedrine (EPH), scopolamine (SCP) and cocaine (COC).


  • Open Access

    Scopolamine analysis in beverages: Bicolorimetric device vs portable nano liquid chromatography

    by N. Jornet-Martínez, R. Herráez-Hernández, P. Campíns-Falcó


  • Open Access

    New Reusable Solid Biosensor with Covalent Immobilization of the Horseradish Peroxidase Enzyme: In Situ Liberation Studies of Hydrogen Peroxide by Portable Chemiluminescent Determination

    by Sara Bocanegra-Rodríguez, Neus Jornet-Martínez, Carmen Molins-Legua, Pilar Campíns-Falcó

    Herein, we reported a chemiluminescent biosensor based on the covalent immobilization of the horseradish peroxidase (HRP) enzyme on a polydimethylsiloxane (PDMS) support to quantify in situ hydrogen peroxide (H2O2). The chemiluminescent reaction based on the use of luminol as an oxidizable substrate, with HRP as the catalyst, has been used in order to quantify H2O2 as the oxidizing agent. The performance of the proposed biosensor has been demonstrated to determine H2O2 liberated by cells in a culture medium and for evaluating the delivery of H2O2 from denture cleaner tablets, as examples of application. For both analyses, the results indicated that the biosensor is cost-effective, sensitive, and selective with a detection limit of 0.02 μM and good linearity over the range 0.06–10 μM. Precision was also satisfactory (relative standard deviation, % RSD < 6). The strength of this biosensing system is the simplicity, portability, and reusability of the devices; it can be applied up to 60 times with 90% of its activity maintained.


  • Nylon-Supported Plasmonic Assay Based on the Aggregation of Silver Nanoparticles: In Situ Determination of Hydrogen Sulfide-like Compounds in Breath Samples as a Proof of Concept

    by Neus Jornet-Martínez, Lusine Hakobyan, Ana Isabel Argente-García, Carmen Molins-Legua, Pilar Campíns-Falcó

    A procedure for supporting silver nanoparticles (AgNPs) on nylon is proposed. Besides, the membrane has been developed as a solid-phase colorimetric plasmonic sensor for volatile sulfide compounds (VSCs) like H2S, CH3SH, and (CH3)2S. AgNP behavior in the membrane has been studied by UV–vis diffuse reflectance spectrometry, Raman spectrometry, High-resolution transmission electron microscopy (HR-TEM), and Scanning electron microscopy (SEM). The sensor responded by changing its color from yellow in absence of VSCs to several orange/brown colors in the function of VSC concentration as occurs in solution; an increase in the hydrodynamic diameter, estimated by both asymmetrical flow field-flow fractionation (AF4) coupled on line to Dynamic light scattering (DLS) detector and batch DLS, is achieved when sulfide is added to the citrate-capped AgNPs. Diffuse reflectance spectrometry and processed digital images obtained with a smartphone have been used as measurements and several transformations for quantitation are proposed; a linear concentration range of hydrogen sulfide from 150 to 1000 ppbv and a detection limit (LOD) of 45 ppbv were achieved, measuring after 10 min of the sensor exposition to the hydrogen sulfide atmosphere (2 L) for humidity percentages between 50 and 96% and room temperature. Satisfactory results in terms of precision (<10%) and selectivity were obtained. The new sensor reported was stable, sensitive, inexpensive, disposable, safe, and user-friendly. Furthermore, it has successfully been applied to determine VSCs expressed as hydrogen sulfide in breath samples (2 L and 250 mL) as a proof of concept. The limit of detection can be improved by increasing the exposition time, if necessary.


  • Quantifying both ammonium and proline in wines and beer by using a PDMS composite for sensoring

    by María Carmen Prieto-Blanco, Neus Jornet-Martinez, Jorge Verdú-Andrés, Carmen Molíns-Legua, Pilar Campíns-Falcó


  • Towards sarcosine determination in urine for prostatic carcinoma detection

    by Neus Jornet-Martínez, Cassi J. Henderson, Pilar Campíns-Falcó, Ronan Daly, Elizabeth A.H. Hall