Hande Pamukçu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Hande Pamukçu has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Ömür Polat Özsoy
Private Practice Ankara Türkiye
3 shared publications Begüm Köktürk
Department of Orthodontics, Faculty of Dentistry Başkent University Ankara Turkey
2 shared publicationsEce Mersan Ateş
Department of Orthodontics, School of Dentistry, Başkent University, Ankara, Turkey
2 shared publicationsSerhat Özsoy
2 shared publications- Ömür Polat Özsoy
Department of Orthodontics, Faculty of Dentistry, Izmir Tinaztepe University , Izmir , Turkey
2 shared publications A Atakan
Department of Orthodontics, Faculty of Dentistry, University of Baskent, Ankara, Turkey
1 shared publication
Latest Publications
- Open Access
- 14 November 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Comparative Clinical Performance of Lingual Fixed Appliances and Clear Aligner Therapy for Esthetic Deep‐Bite Correction in Adults
Objective: Adult deep‐bite correction extends beyond orthodontic alignment because it directly influences anterior esthetics, incisal display, smile arc, anterior guidance, restorative space, and the interdisciplinary planning required for minimally invasive esthetic rehabilitation. Although lingual fixed appliances and clear aligner therapy are widely used esthetic treatment modalities, evidence directly comparing their effectiveness for vertical correction in adults and its potential restorative implications remains limited. Therefore, this study compared adjusted posttreatment overbite and selected cephalometric outcomes between these two treatment modalities in adult deep‐bite patients. Materials and Methods: Pretreatment and posttreatment lateral cephalograms of 38 adult deep‐bite patients were analyzed: 19 treated with lingual fixed appliances and 19 with clear aligner therapy. Skeletal and dentoalveolar variables were compared within and between groups. Adjusted between‐group treatment effects were assessed using analysis of covariance models controlling for baseline values and age; a second model additionally adjusted for sex, malocclusion class, and treatment duration. Results: Baseline characteristics were comparable, except for a smaller maxillary first molar angulation in the clear aligner group. Skeletal parameters remained generally stable. Both groups showed significant overbite reduction, but overbite correction was greater in the lingual group. Adjusted posttreatment overbite was significantly higher in the clear aligner group than in the lingual group (Model I: 1.03 mm and Model II: 1.05 mm; both p < 0.001). Conclusions: Lingual fixed appliances were associated with significantly greater adjusted overbite reduction than clear aligner therapy in this retrospective sample of adults with deep‐bite malocclusion. Although overbite decreased significantly in both groups, the findings indicate a difference in the amount of correction achieved. This finding may inform appliance selection when planning vertical correction as part of interdisciplinary esthetic and restorative treatment.
- 14 November 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Open AccessComparative Clinical Performance of Lingual Fixed Appliances and Clear Aligner Therapy for Esthetic Deep‐Bite Correction in Adults
Objective: Adult deep‐bite correction extends beyond orthodontic alignment because it directly influences anterior esthetics, incisal display, smile arc, anterior guidance, restorative space, and the interdisciplinary planning required for minimally invasive esthetic rehabilitation. Although lingual fixed appliances and clear aligner therapy are widely used esthetic treatment modalities, evidence directly comparing their effectiveness for vertical correction in adults and its potential restorative implications remains limited. Therefore, this study compared adjusted posttreatment overbite and selected cephalometric outcomes between these two treatment modalities in adult deep‐bite patients. Materials and Methods: Pretreatment and posttreatment lateral cephalograms of 38 adult deep‐bite patients were analyzed: 19 treated with lingual fixed appliances and 19 with clear aligner therapy. Skeletal and dentoalveolar variables were compared within and between groups. Adjusted between‐group treatment effects were assessed using analysis of covariance models controlling for baseline values and age; a second model additionally adjusted for sex, malocclusion class, and treatment duration. Results: Baseline characteristics were comparable, except for a smaller maxillary first molar angulation in the clear aligner group. Skeletal parameters remained generally stable. Both groups showed significant overbite reduction, but overbite correction was greater in the lingual group. Adjusted posttreatment overbite was significantly higher in the clear aligner group than in the lingual group (Model I: 1.03 mm and Model II: 1.05 mm; both p < 0.001). Conclusions: Lingual fixed appliances were associated with significantly greater adjusted overbite reduction than clear aligner therapy in this retrospective sample of adults with deep‐bite malocclusion. Although overbite decreased significantly in both groups, the findings indicate a difference in the amount of correction achieved. This finding may inform appliance selection when planning vertical correction as part of interdisciplinary esthetic and restorative treatment.
- Open Access
- 1 July 2024
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 94 (4) , 392-399
Evaluation of maxillary dimensional changes in the mixed dentition: clear aligners vs acrylic expanders
Objectives: To compare changes in upper arch dimension and molar inclination between Invisalign First (IF) and removable acrylic expander (RE) treatments during the mixed dentition period. Materials and Methods: Seventeen patients meeting inclusion criteria underwent IF treatment and were age matched with a group that received treatment with a removable acrylic expander (RE). Intercanine width (ICW), intermolar width, arch depth, buccolingual inclination of the first molars (MI), surface area (SA) and volume (VAP) of the anterior palate, and expansion were compared before and after treatment. The predictability of expansion was calculated for the IF group. Analysis of variance and Kruskal-Wallis tests were used to assess differences. Results: The ICW increased significantly by 2.14 mm in the IF group and 3.49 mm in the RE group, with no significant intergroup difference. Both groups exhibited significant increases in intermolar width ( P < .05), except for intermolar distopalatal width in the IF group ( P = .246). Mesiobuccal rotation of the first molar was observed with IF treatment. Although SA and VAP increased in both groups, the changes were not significant for the IF group ( P > .05). The RE group exhibited significantly higher increases ( P < .05), with an SA increase of 34.32 mm 2 and VAP increase of 119.15 mm 3 . MI changes were in the opposite directions. The prediction accuracy of expansion was 70.28% for canines and 34.12% for first molars. Conclusions: Both appliances effectively expanded the intercanine region in growing patients. Expansion predictability was lower in first molars than in canines for the IF group. Removable acrylic expanders could be a choice of preference for expansion targeted to the molar region.
- 1 July 2024
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 94 (4) , 392-399
Open AccessEvaluation of maxillary dimensional changes in the mixed dentition: clear aligners vs acrylic expanders
Objectives: To compare changes in upper arch dimension and molar inclination between Invisalign First (IF) and removable acrylic expander (RE) treatments during the mixed dentition period. Materials and Methods: Seventeen patients meeting inclusion criteria underwent IF treatment and were age matched with a group that received treatment with a removable acrylic expander (RE). Intercanine width (ICW), intermolar width, arch depth, buccolingual inclination of the first molars (MI), surface area (SA) and volume (VAP) of the anterior palate, and expansion were compared before and after treatment. The predictability of expansion was calculated for the IF group. Analysis of variance and Kruskal-Wallis tests were used to assess differences. Results: The ICW increased significantly by 2.14 mm in the IF group and 3.49 mm in the RE group, with no significant intergroup difference. Both groups exhibited significant increases in intermolar width ( P < .05), except for intermolar distopalatal width in the IF group ( P = .246). Mesiobuccal rotation of the first molar was observed with IF treatment. Although SA and VAP increased in both groups, the changes were not significant for the IF group ( P > .05). The RE group exhibited significantly higher increases ( P < .05), with an SA increase of 34.32 mm 2 and VAP increase of 119.15 mm 3 . MI changes were in the opposite directions. The prediction accuracy of expansion was 70.28% for canines and 34.12% for first molars. Conclusions: Both appliances effectively expanded the intercanine region in growing patients. Expansion predictability was lower in first molars than in canines for the IF group. Removable acrylic expanders could be a choice of preference for expansion targeted to the molar region.
- 5 June 2024
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 125 (5) , 101936
Effects of different expansion appliances and surgical incisions on maxillary expansion: A finite element analysis
- 5 June 2024
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 125 (5) , 101936
Effects of different expansion appliances and surgical incisions on maxillary expansion: A finite element analysis
- Open Access
- 20 May 2024
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 27 (S2) , 13-24
Evaluation of different machine learning algorithms for extraction decision in orthodontic treatment
Introduction: The extraction decision significantly affects the treatment process and outcome. Therefore, it is crucial to make this decision with a more objective and standardized method. The objectives of this study were (1) to identify the best‐performing model among seven machine learning (ML) models, which will standardize the extraction decision and serve as a guide for inexperienced clinicians, and (2) to determine the important variables for the extraction decision.Methods: This study included 1000 patients who received orthodontic treatment with or without extraction (500 extraction and 500 non‐extraction). The success criteria of the study were the decisions made by the four experienced orthodontists. Seven ML models were trained using 36 variables; including demographic information, cephalometric and model measurements. First, the extraction decision was performed, and then the extraction type was identified. Accuracy and area under the curve (AUC) of the receiver operating characteristics (ROC) curve were used to measure the success of ML models.Results: The Stacking Classifier model, which consists of Gradient Boosted Trees, Support Vector Machine, and Random Forest models, showed the highest performance in extraction decision with 91.2% AUC. The most important features determining extraction decision were maxillary and mandibular arch length discrepancy, Wits Appraisal, and ANS‐Me length. Likewise, the Stacking Classifier showed the highest performance with 76.3% accuracy in extraction type decisions. The most important variables for the extraction type decision were mandibular arch length discrepancy, Class I molar relationship, cephalometric overbite, Wits Appraisal, and L1‐NB distance.Conclusion: The Stacking Classifier model exhibited the best performance for the extraction decision. While ML models showed a high performance in extraction decision, they could not able to achieve the same level of performance in extraction type decision.
- 20 May 2024
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 27 (S2) , 13-24
Open AccessEvaluation of different machine learning algorithms for extraction decision in orthodontic treatment
Introduction: The extraction decision significantly affects the treatment process and outcome. Therefore, it is crucial to make this decision with a more objective and standardized method. The objectives of this study were (1) to identify the best‐performing model among seven machine learning (ML) models, which will standardize the extraction decision and serve as a guide for inexperienced clinicians, and (2) to determine the important variables for the extraction decision.Methods: This study included 1000 patients who received orthodontic treatment with or without extraction (500 extraction and 500 non‐extraction). The success criteria of the study were the decisions made by the four experienced orthodontists. Seven ML models were trained using 36 variables; including demographic information, cephalometric and model measurements. First, the extraction decision was performed, and then the extraction type was identified. Accuracy and area under the curve (AUC) of the receiver operating characteristics (ROC) curve were used to measure the success of ML models.Results: The Stacking Classifier model, which consists of Gradient Boosted Trees, Support Vector Machine, and Random Forest models, showed the highest performance in extraction decision with 91.2% AUC. The most important features determining extraction decision were maxillary and mandibular arch length discrepancy, Wits Appraisal, and ANS‐Me length. Likewise, the Stacking Classifier showed the highest performance with 76.3% accuracy in extraction type decisions. The most important variables for the extraction type decision were mandibular arch length discrepancy, Class I molar relationship, cephalometric overbite, Wits Appraisal, and L1‐NB distance.Conclusion: The Stacking Classifier model exhibited the best performance for the extraction decision. While ML models showed a high performance in extraction decision, they could not able to achieve the same level of performance in extraction type decision.
- Open Access
- 4 September 2023
- Published by Acta Odontologica Turcica in Acta Odontologica Turcica
- Vol. 40 (3) , 84-91
Comparison of the initial levelling efficiency of two different self-ligating brackets
Aim: The objective of this study, to evaluate the initial alignment effectiveness of two different passive self-ligating brackets (SLBs) and to compare the differences in arch widths. Materials and Methods: The patients with no skeletal discrepancy, Little’s irregularity index (LII) greater than 3 mm on both arches, who were treated with SLBs and whom had undamaged plaster models at the beginning (T0), 10th week (T1), and 20th week (T2) of their treatment period were enrolled to the study group. Group 1 (Damon) was consisted of 17 patients (mean age=14.5 years) and Group 2 (SmartClip) was consisted of 18 patients (mean age=13.6 years). The analogue dental casts were transferred to a digital model by scanning. Maxillary and mandibular intercanine, intermolar widths and LII were measured by MeshLab software. Wilcoxon signed-rank and Mann Whitney U tests was used for statistical evaluation. Results: There were no significant differences between the groups for the mean LII in T0 (maxillary LII, Group 1= 6.59 mm; Group 2= 6.32 mm; mandibular LII, Group 1= 5.95 mm, Group 2= 5.73mm). The rate of decrease in the LII between T0-T2 and between T1-T2 were found to be significantly higher for Group 1 in the mandible but there was no significant difference between T0-T1 (P= 0.031, P= 0.042, P= 0.113). There was no significant difference for the rate of decrease in the LIIs between the groups in the maxilla. When changes of intermolar and intercanine widths were compared according to the follow-up times, no significant differences were found for the treatment groups. Conclusion: Both SLBs groups were effective for reducing the crowding in maxillary arch. The increases in intercanine and intermolar widths were found to be similar for both groups. Group 1 was found to be better in the speed of the resolution of the crowding only in the lower incisor region.
- 4 September 2023
- Published by Acta Odontologica Turcica in Acta Odontologica Turcica
- Vol. 40 (3) , 84-91
Open AccessComparison of the initial levelling efficiency of two different self-ligating brackets
Aim: The objective of this study, to evaluate the initial alignment effectiveness of two different passive self-ligating brackets (SLBs) and to compare the differences in arch widths. Materials and Methods: The patients with no skeletal discrepancy, Little’s irregularity index (LII) greater than 3 mm on both arches, who were treated with SLBs and whom had undamaged plaster models at the beginning (T0), 10th week (T1), and 20th week (T2) of their treatment period were enrolled to the study group. Group 1 (Damon) was consisted of 17 patients (mean age=14.5 years) and Group 2 (SmartClip) was consisted of 18 patients (mean age=13.6 years). The analogue dental casts were transferred to a digital model by scanning. Maxillary and mandibular intercanine, intermolar widths and LII were measured by MeshLab software. Wilcoxon signed-rank and Mann Whitney U tests was used for statistical evaluation. Results: There were no significant differences between the groups for the mean LII in T0 (maxillary LII, Group 1= 6.59 mm; Group 2= 6.32 mm; mandibular LII, Group 1= 5.95 mm, Group 2= 5.73mm). The rate of decrease in the LII between T0-T2 and between T1-T2 were found to be significantly higher for Group 1 in the mandible but there was no significant difference between T0-T1 (P= 0.031, P= 0.042, P= 0.113). There was no significant difference for the rate of decrease in the LIIs between the groups in the maxilla. When changes of intermolar and intercanine widths were compared according to the follow-up times, no significant differences were found for the treatment groups. Conclusion: Both SLBs groups were effective for reducing the crowding in maxillary arch. The increases in intercanine and intermolar widths were found to be similar for both groups. Group 1 was found to be better in the speed of the resolution of the crowding only in the lower incisor region.
- 3 April 2023
- Published by Academician Publishing
- p. 19-42
Sabit Ortodontik Apareylerin Şeffaf Plaklar İle Biyomekanik Yönden Karşılaştırılması
- 3 April 2023
- Published by Academician Publishing
- p. 19-42
Sabit Ortodontik Apareylerin Şeffaf Plaklar İle Biyomekanik Yönden Karşılaştırılması
- Open Access
- 21 March 2023
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 36 (1) , 1-9
Transfer Accuracy of Three Indirect Bonding Trays: An In Vitro Study with 3D Scanned Models
The goal of the current study is to compare the transfer accuracy of two different conventional indirect bonding trays with 3D-printed trays. Twenty-two patients’ upper dental models were duplicated, scanned and brackets were bonded digitally. Different indirect bonding trays (double vacuum formed, transparent silicone and 3D-printed) were prepared according to three groups. These trays were used for the transfer of the brackets to the patients’ models, then models with brackets were scanned. GOM Inspect software was used for the superimposition of virtual bracket setups and models with brackets. A total of 788 brackets and tubes were analyzed. Transfer accuracies were determined according to the clinical limit of 0.5 mm for linear and 2° for angular measurements. 3D-printed trays had significantly lower linear deviation values than other trays for all planes (p<0.05). 3D-printed trays have significantly lower torque and tip deviation values than other groups (p<0.05). Transfer deviations were within the clinically acceptable limit for all transfer trays in horizontal, vertical and transverse planes. Deviation values of the molars were higher than those of the other tooth groups for all trays in the horizontal and vertical planes (p<0.05). Brackets were generally deviated toward the buccal direction in all tray groups. The transfer accuracy of 3D-printed transfer trays was more successful than the double vacuum formed and transparent silicone trays in the indirect bonding technique procedure. Deviations in the molar group were greater than those in the other tooth groups for all transfer trays.
- 21 March 2023
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 36 (1) , 1-9
Open AccessTransfer Accuracy of Three Indirect Bonding Trays: An In Vitro Study with 3D Scanned Models
The goal of the current study is to compare the transfer accuracy of two different conventional indirect bonding trays with 3D-printed trays. Twenty-two patients’ upper dental models were duplicated, scanned and brackets were bonded digitally. Different indirect bonding trays (double vacuum formed, transparent silicone and 3D-printed) were prepared according to three groups. These trays were used for the transfer of the brackets to the patients’ models, then models with brackets were scanned. GOM Inspect software was used for the superimposition of virtual bracket setups and models with brackets. A total of 788 brackets and tubes were analyzed. Transfer accuracies were determined according to the clinical limit of 0.5 mm for linear and 2° for angular measurements. 3D-printed trays had significantly lower linear deviation values than other trays for all planes (p<0.05). 3D-printed trays have significantly lower torque and tip deviation values than other groups (p<0.05). Transfer deviations were within the clinically acceptable limit for all transfer trays in horizontal, vertical and transverse planes. Deviation values of the molars were higher than those of the other tooth groups for all trays in the horizontal and vertical planes (p<0.05). Brackets were generally deviated toward the buccal direction in all tray groups. The transfer accuracy of 3D-printed transfer trays was more successful than the double vacuum formed and transparent silicone trays in the indirect bonding technique procedure. Deviations in the molar group were greater than those in the other tooth groups for all transfer trays.
- 13 March 2023
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 84 (S3) , 266-275
Color changes of nanocomposites used for clear aligner attachments: an in vitro study
Purpose The purpose of this study was to compare the color changes of two different nanocomposites used for two different designs of clear aligner attachments. Methods In all, 120 human premolars were embedded in 12 upper dental models with 10 premolars in each model. Models were scanned and attachments were digitally designed. Conventional attachments (CA) were prepared for the first six models and optimized multiplane attachments (OA) were prepared for the other six models with packable composite (PC) on the right quadrant and flowable composite (FC) on the left quadrant of each model. The models were subjected to 2000 thermal cycles at 5 °C/55 °C and then consecutively immersed in the five different staining solutions each for 48 h to simulate external discoloration. Color measurements were taken with a spectrophotometer. Color changes (∆E*ab) of the attachments before and after immersion were compared with the Commission Internationale de l’Éclairage L*a*b* (CIELAB) color space approach. Results When ∆E*ab values were examined, no significant difference was observed between the groups according to the attachment type (P > 0.05). After the coloration process, the flowable composite group showed less coloration than the packable composite group for both attachment designs (P < 0.05). Color difference values after the staining procedure were significantly higher in the CA-PC and OA-PC groups compared to the CA-FC and OA-FC groups (P < 0.05). Conclusion Color change of the packable nanocomposite was more pronounced than that of the flowable nanocomposite for both attachment designs. Therefore, clear aligner attachments created using flowable nanocomposite can be recommended, especially in the anterior region where esthetics are important for the patient.
- 13 March 2023
- Published by Springer Nature in Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie
- Vol. 84 (S3) , 266-275
Color changes of nanocomposites used for clear aligner attachments: an in vitro study
Purpose The purpose of this study was to compare the color changes of two different nanocomposites used for two different designs of clear aligner attachments. Methods In all, 120 human premolars were embedded in 12 upper dental models with 10 premolars in each model. Models were scanned and attachments were digitally designed. Conventional attachments (CA) were prepared for the first six models and optimized multiplane attachments (OA) were prepared for the other six models with packable composite (PC) on the right quadrant and flowable composite (FC) on the left quadrant of each model. The models were subjected to 2000 thermal cycles at 5 °C/55 °C and then consecutively immersed in the five different staining solutions each for 48 h to simulate external discoloration. Color measurements were taken with a spectrophotometer. Color changes (∆E*ab) of the attachments before and after immersion were compared with the Commission Internationale de l’Éclairage L*a*b* (CIELAB) color space approach. Results When ∆E*ab values were examined, no significant difference was observed between the groups according to the attachment type (P > 0.05). After the coloration process, the flowable composite group showed less coloration than the packable composite group for both attachment designs (P < 0.05). Color difference values after the staining procedure were significantly higher in the CA-PC and OA-PC groups compared to the CA-FC and OA-FC groups (P < 0.05). Conclusion Color change of the packable nanocomposite was more pronounced than that of the flowable nanocomposite for both attachment designs. Therefore, clear aligner attachments created using flowable nanocomposite can be recommended, especially in the anterior region where esthetics are important for the patient.
- 1 September 2022
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 35 (3) , 198-206
Cephalometric Mandibular Dimensions in Growing Turkish Children: Trends of Change, Sex-Specific Differences, and Comparisons with Published Norms
Corpus length,mandibular dimensions,mandibular length,ramus height,Turkish children
- 1 September 2022
- Published by Galenos Yayinevi in Turkish Journal of Orthodontics
- Vol. 35 (3) , 198-206
Cephalometric Mandibular Dimensions in Growing Turkish Children: Trends of Change, Sex-Specific Differences, and Comparisons with Published Norms
Corpus length,mandibular dimensions,mandibular length,ramus height,Turkish children
- Open Access
- 1 January 2022
- Published by Walter de Gruyter GmbH in Australasian Orthodontic Journal
- Vol. 38 (1) , 1-12
Orthognathic surgery-first approach with lingual appliances: a case report
Background: A surgery-first approach has many advantages related to a shortened treatment time and an immediate facial aesthetic improvement compared to a three-stage conventional orthognathic surgery protocol. Objective: The aim of this case report was to describe the treatment of a 21-year-old, female, patient who presented with a skeletal Class III malocclusion, maxillary retrusion, a negative overjet, an anterior and bilateral posterior cross-bite, and a vertical facial pattern highlighted by a high mandibular plane angle. Methods: Orthodontic treatment was performed using self-ligating lingual appliances and a surgery-first approach. The active treatment time was 16 months. Results and conclusion: Successful treatment results were achieved using a combination of an orthognathic surgery-first approach and lingual appliances in a patient with high aesthetic expectations.
- 1 January 2022
- Published by Walter de Gruyter GmbH in Australasian Orthodontic Journal
- Vol. 38 (1) , 1-12
Open AccessOrthognathic surgery-first approach with lingual appliances: a case report
Background: A surgery-first approach has many advantages related to a shortened treatment time and an immediate facial aesthetic improvement compared to a three-stage conventional orthognathic surgery protocol. Objective: The aim of this case report was to describe the treatment of a 21-year-old, female, patient who presented with a skeletal Class III malocclusion, maxillary retrusion, a negative overjet, an anterior and bilateral posterior cross-bite, and a vertical facial pattern highlighted by a high mandibular plane angle. Methods: Orthodontic treatment was performed using self-ligating lingual appliances and a surgery-first approach. The active treatment time was 16 months. Results and conclusion: Successful treatment results were achieved using a combination of an orthognathic surgery-first approach and lingual appliances in a patient with high aesthetic expectations.