Yanxin Dou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yanxin Dou has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Jianli Liu
Harbin Inst Technol, Res Ctr Basic Space Sci, Harbin 150001, Heilongjiang, Peoples R China
5 shared publications- Liyi Li
Harbin Institute of Technology
4 shared publications Thomas Osipowicz
Centre for Ion Beam Applications, Department of Physics, National University of Singapore 3 , Singapore
4 shared publicationsDavid N. Jamieson
3 shared publications- David N. Jamieson
Centre of Excellence for Quantum Computation and Communication Technology
2 shared publications Guoming Lin
Department of Chemistry, National University of Singapore, Singapore, Singapore
2 shared publications
Latest Publications
- Open Access
- 7 October 2026
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 23 (243)
Coffee-ring effect enables correlative super-resolution imaging of label-free chromosomes
High-resolution chromosome imaging plays a key role in understanding chromosome structure. However, traditional methods for super-resolution (<200 nm) chromosome imaging are often complex and time-consuming, requiring purification, staining or sectioning of chromosomes. Here, we propose a novel and simple method to achieve correlative super-resolution imaging for label-free chromosomes through the utilization of the coffee-ring effect. An application of this method is shown to identify dicentric chromosomes and acentric fragments.
- 7 October 2026
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 23 (243)
Open AccessCoffee-ring effect enables correlative super-resolution imaging of label-free chromosomes
High-resolution chromosome imaging plays a key role in understanding chromosome structure. However, traditional methods for super-resolution (<200 nm) chromosome imaging are often complex and time-consuming, requiring purification, staining or sectioning of chromosomes. Here, we propose a novel and simple method to achieve correlative super-resolution imaging for label-free chromosomes through the utilization of the coffee-ring effect. An application of this method is shown to identify dicentric chromosomes and acentric fragments.
- 28 July 2025
- Published by Springer Nature in Nature Nanotechnology
- Vol. 20 (10) , 1431-1438
Ultraclean monolayer amorphous carbon yields a high-precision proton beam
Ångström-scale polygonal rings in monolayer amorphous carbon (MAC) enhance its electronic and mechanical properties while providing unique ångström pores for precise subatomic species separation, essential for advancements in catalysis, energy and medicine. However, the absence of an industrial-scale synthesis method for intrinsic MAC has limited its technological applications compared with graphene and bulk amorphous materials. Herein, we report an industry-compatible disorder-to-disorder synthesis approach to achieve wafer-scale ultraclean MAC (UC-MAC) within a timescale of seconds, featuring optimized ångström polygons without detectable metal contamination, and nanosized pores. In contrast to metal-contaminated MAC, UC-MAC allows atomic-scale characterization of intrinsic electronic properties and functions as an ångström-scale membrane, facilitating the splitting of high-flux H2+ ions into a high-precision proton beam with minimal detrimental fragment-proton scattering events, about half and 40 times less than those from single-crystal graphene and commercial carbon thin films, respectively. The minimum possible membrane material thickness that can yield a highly sharpened proton beam with accurately modulated beam current is desired for proton therapy.
- 28 July 2025
- Published by Springer Nature in Nature Nanotechnology
- Vol. 20 (10) , 1431-1438
Ultraclean monolayer amorphous carbon yields a high-precision proton beam
Ångström-scale polygonal rings in monolayer amorphous carbon (MAC) enhance its electronic and mechanical properties while providing unique ångström pores for precise subatomic species separation, essential for advancements in catalysis, energy and medicine. However, the absence of an industrial-scale synthesis method for intrinsic MAC has limited its technological applications compared with graphene and bulk amorphous materials. Herein, we report an industry-compatible disorder-to-disorder synthesis approach to achieve wafer-scale ultraclean MAC (UC-MAC) within a timescale of seconds, featuring optimized ångström polygons without detectable metal contamination, and nanosized pores. In contrast to metal-contaminated MAC, UC-MAC allows atomic-scale characterization of intrinsic electronic properties and functions as an ångström-scale membrane, facilitating the splitting of high-flux H2+ ions into a high-precision proton beam with minimal detrimental fragment-proton scattering events, about half and 40 times less than those from single-crystal graphene and commercial carbon thin films, respectively. The minimum possible membrane material thickness that can yield a highly sharpened proton beam with accurately modulated beam current is desired for proton therapy.
- Open Access
- 9 April 2025
- Published by Springer Nature in Research Square
Ultra-Clean Angstroporous Monolayer Amorphous Carbon Yields High Precision Proton Beam
Angstrom-scale polygonal rings in monolayer amorphous carbon (MAC) not only tailor its electronic and mechanical properties, but also endow the atomically thin membrane material with diverse angstrom pores for precise regulation of the subatomic species separation and transport, crucial for technological advances across various fields including catalysis, energy devices, and medical applications. However, the lack of industrial-scale synthesis route of intrinsic MAC has severely hindered the progress to harness their versatile angstrom polygons and properties for technological applications that are not offered by the state-of-the-art graphene or bulk amorphous materials. Herein, we report an industry-compatible disorder-to-disorder (DTD) synthetic approach to achieve wafer-scale intrinsic ultra-clean MAC (UC-MAC) within seconds-timescale, featuring optimized angstrom polygons without detectable metal contamination and nano-sized pores. Contrary to metal-contaminated MAC, angstroporous UC-MAC enables not only atomic-scale characterization of its intrinsic electronic properties, but also serve as an angstroporous membrane material, enabling the splitting of high-flux H2+ ions into a high-precision proton beam with minimal detrimental fragment proton scattering events to date, about twice and 40 times less than those from graphene and commercial carbon thin films, respectively. The membrane with minimum possible material thickness that can yield a highly sharpened proton beam with accurately modulated beam current is desired for proton therapy, especially for non-invasive tumor treatment.
- 9 April 2025
- Published by Springer Nature in Research Square
Open AccessUltra-Clean Angstroporous Monolayer Amorphous Carbon Yields High Precision Proton Beam
Angstrom-scale polygonal rings in monolayer amorphous carbon (MAC) not only tailor its electronic and mechanical properties, but also endow the atomically thin membrane material with diverse angstrom pores for precise regulation of the subatomic species separation and transport, crucial for technological advances across various fields including catalysis, energy devices, and medical applications. However, the lack of industrial-scale synthesis route of intrinsic MAC has severely hindered the progress to harness their versatile angstrom polygons and properties for technological applications that are not offered by the state-of-the-art graphene or bulk amorphous materials. Herein, we report an industry-compatible disorder-to-disorder (DTD) synthetic approach to achieve wafer-scale intrinsic ultra-clean MAC (UC-MAC) within seconds-timescale, featuring optimized angstrom polygons without detectable metal contamination and nano-sized pores. Contrary to metal-contaminated MAC, angstroporous UC-MAC enables not only atomic-scale characterization of its intrinsic electronic properties, but also serve as an angstroporous membrane material, enabling the splitting of high-flux H2+ ions into a high-precision proton beam with minimal detrimental fragment proton scattering events to date, about twice and 40 times less than those from graphene and commercial carbon thin films, respectively. The membrane with minimum possible material thickness that can yield a highly sharpened proton beam with accurately modulated beam current is desired for proton therapy, especially for non-invasive tumor treatment.
- Open Access
- 8 January 2024
- Published by Springer Nature in Nature Materials
- Vol. 23 (6) , 803-809
Real-time single-proton counting with transmissive perovskite nanocrystal scintillators
High-sensitivity radiation detectors for energetic particles are essential for advanced applications in particle physics, astronomy and cancer therapy. Current particle detectors use bulk crystals, and thin-film organic scintillators have low light yields and limited radiation tolerance. Here we present transmissive thin scintillators made from CsPbBr3 nanocrystals, designed for real-time single-proton counting. These perovskite scintillators exhibit exceptional sensitivity, with a high light yield (~100,000 photons per MeV) when subjected to proton beams. This enhanced sensitivity is attributed to radiative emission from biexcitons generated through proton-induced upconversion and impact ionization. These scintillators can detect as few as seven protons per second, a sensitivity level far below the rates encountered in clinical settings. The combination of rapid response (~336 ps) and pronounced ionostability enables diverse applications, including single-proton tracing, patterned irradiation and super-resolution proton imaging. These advancements have the potential to improve proton dosimetry in proton therapy and radiography.
- 8 January 2024
- Published by Springer Nature in Nature Materials
- Vol. 23 (6) , 803-809
Open AccessReal-time single-proton counting with transmissive perovskite nanocrystal scintillators
High-sensitivity radiation detectors for energetic particles are essential for advanced applications in particle physics, astronomy and cancer therapy. Current particle detectors use bulk crystals, and thin-film organic scintillators have low light yields and limited radiation tolerance. Here we present transmissive thin scintillators made from CsPbBr3 nanocrystals, designed for real-time single-proton counting. These perovskite scintillators exhibit exceptional sensitivity, with a high light yield (~100,000 photons per MeV) when subjected to proton beams. This enhanced sensitivity is attributed to radiative emission from biexcitons generated through proton-induced upconversion and impact ionization. These scintillators can detect as few as seven protons per second, a sensitivity level far below the rates encountered in clinical settings. The combination of rapid response (~336 ps) and pronounced ionostability enables diverse applications, including single-proton tracing, patterned irradiation and super-resolution proton imaging. These advancements have the potential to improve proton dosimetry in proton therapy and radiography.
- 13 July 2023
- Published by Elsevier in Ultramicroscopy
- Vol. 253, 113812
Breaking the 10 nm barrier using molecular ions in nuclear microprobes
- 13 July 2023
- Published by Elsevier in Ultramicroscopy
- Vol. 253, 113812
Breaking the 10 nm barrier using molecular ions in nuclear microprobes
- 1 January 2021
- Published by Elsevier in Ultramicroscopy
- Vol. 220, 113163
FANM: A software for focus and aberrations of nuclear microprobe
- 1 January 2021
- Published by Elsevier in Ultramicroscopy
- Vol. 220, 113163
FANM: A software for focus and aberrations of nuclear microprobe
- Open Access
- 1 January 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (1) , 013310
Considerations for the nano aperture ion source: Geometrical design and electrical control
A new type of ion source is being developed for proton beam writing and other focused ion beam applications. The potential of this source as well as achieved performance of the nano aperture ion source will be evaluated. Based on the ideal source parameters, critical geometrical parameters constraining chromatic aberrations and a possible pathway to achieve this performance will be presented. Finally, an electronic control system to minimize chromatic and spherical aberrations to an acceptable level will be demonstrated.
- 1 January 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (1) , 013310
Open AccessConsiderations for the nano aperture ion source: Geometrical design and electrical control
A new type of ion source is being developed for proton beam writing and other focused ion beam applications. The potential of this source as well as achieved performance of the nano aperture ion source will be evaluated. Based on the ideal source parameters, critical geometrical parameters constraining chromatic aberrations and a possible pathway to achieve this performance will be presented. Finally, an electronic control system to minimize chromatic and spherical aberrations to an acceptable level will be demonstrated.
- 1 October 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 456, 37-41
Effects of stray magnetic field on the performance of ion microbeam
- 1 October 2019
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 456, 37-41
Effects of stray magnetic field on the performance of ion microbeam
- 1 March 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 419, 49-54
A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system
- 1 March 2018
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 419, 49-54
A high excitation magnetic quadrupole lens quadruplet incorporating a single octupole lens for a low spherical aberration probe forming lens system