JMJan-Jurre Mordang

Jan-Jurre Mordang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jan-Jurre Mordang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Nico Karssemeijer

    Radboud Univ. Medical Ctr. (Netherlands)

    3 shared publications
  • Albert Gubern-Mérida

    Diagnostic Image Analysis Group, Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands

    2 shared publications
  • Alessandro Bria

    Department of Electrical and Information Engineering, University of Cassino and Southern Lazio, Cassino, Italy

    2 shared publications
  • Gerard Den Heeten

    Department of Radiology, Amsterdam Medical Center, Amsterdam, the Netherlands

    2 shared publications
  • A. Bria

    Department of Electrical and Information Engineering, University of Cassino and Southern Lazio, Cassino, Italy

    1 shared publication
  • A. Gubern-Mérida

    Department of Radiology and Nuclear Medicine, Radboud University Medical Center, Nijmegen, The Netherlands

    1 shared publication

Latest Publications

  • Open Access

    The importance of early detection of calcifications associated with breast cancer in screening

    by J. J. Mordang, A. Gubern-Mérida, A. Bria, F. Tortorella, R. M. Mann, M. J. M. Broeders, G. J. Den Heeten, N. Karssemeijer

    The aim of this study was to assess how often women with undetected calcifications in prior screening mammograms are subsequently diagnosed with invasive cancer.


  • Conditional random field modelling of interactions between findings in mammography

    by Thijs Kooi, Jan-Jurre Mordang, Nico Karssemeijer

    Recent breakthroughs in training deep neural network architectures, in particular deep Convolutional Neural Networks (CNNs), made a big impact on vision research and are increasingly responsible for advances in Computer Aided Diagnosis (CAD). Since many natural scenes and medical images vary in size and are too large to feed to the networks as a whole, two stage systems are typically employed, where in the first stage, small regions of interest in the image are located and presented to the network as training and test data. These systems allow us to harness accurate region based annotations, making the problem easier to learn. However, information is processed purely locally and context is not taken into account. In this paper, we present preliminary work on the employment of a Conditional Random Field (CRF) that is trained on top the CNN to model contextual interactions such as the presence of other suspicious regions, for mammography CAD. The model can easily be extended to incorporate other sources of information, such as symmetry, temporal change and various patient covariates and is general in the sense that it can have application in other CAD problems. © (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.


  • Improving computer-aided detection assistance in breast cancer screening by removal of obviously false-positive findings

    by Jan-Jurre Mordang, Albert Gubern-Mérida, Alessandro Bria, Francesco Tortorella, Gerard Den Heeten, Nico Karssemeijer

    Purpose Computer‐aided detection (CADe) systems for mammography screening still mark many false positives. This can cause radiologists to lose confidence in CADe, especially when many false positives are obviously not suspicious to them. In this study, we focus on obvious false positives generated by microcalcification detection algorithms. Methods We aim at reducing the number of obvious false‐positive findings by adding an additional step in the detection method. In this step, a multiclass machine learning method is implemented in which dedicated classifiers learn to recognize the patterns of obvious false‐positive subtypes that occur most frequently. The method is compared to a conventional two‐class approach, where all false‐positive subtypes are grouped together in one class, and to the baseline CADe system without the new false‐positive removal step. The methods are evaluated on an independent dataset containing 1,542 screening examinations of which 80 examinations contain malignant microcalcifications. Results Analysis showed that the multiclass approach yielded a significantly higher sensitivity compared to the other two methods (P < 0.0002). At one obvious false positive per 100 images, the baseline CADe system detected 61% of the malignant examinations, while the systems with the two‐class and multiclass false‐positive reduction step detected 73% and 83%, respectively. Conclusions Our study showed that by adding the proposed method to a CADe system, the number of obvious false positives can decrease significantly (P < 0.0002).


  • Automatic Microcalcification Detection in Multi-vendor Mammography Using Convolutional Neural Networks

    by Jan-Jurre Mordang, Tim Janssen, Alessandro Bria, Thijs Kooi, Albert Gubern-Mérida, Nico Karssemeijer


  • Reducing false positives of microcalcification detection systems by removal of breast arterial calcifications

    by Jan‐Jurre Mordang, Albert Gubern‐Mérida, Gerard Den Heeten, Nico Karssemeijer

    Purpose: In the past decades, computer‐aided detection (CADe) systems have been developed to aid screening radiologists in the detection of malignant microcalcifications. These systems are useful to avoid perceptual oversights and can increase the radiologists’ detection rate. However, due to the high number of false positives marked by these CADe systems, they are not yet suitable as an independent reader. Breast arterial calcifications (BACs) are one of the most frequent false positives marked by CADe systems. In this study, a method is proposed for the elimination of BACs as positive findings. Removal of these false positives will increase the performance of the CADe system in finding malignant microcalcifications.Methods: A multistage method is proposed for the removal of BAC findings. The first stage consists of a microcalcification candidate selection, segmentation and grouping of the microcalcifications, and classification to remove obvious false positives. In the second stage, a case‐based selection is applied where cases are selected which contain BACs. In the final stage, BACs are removed from the selected cases. The BACs removal stage consists of a GentleBoost classifier trained on microcalcification features describing their shape, topology, and texture. Additionally, novel features are introduced to discriminate BACs from other positive findings.Results: The CADe system was evaluated with and without BACs removal. Here, both systems were applied on a validation set containing 1088 cases of which 95 cases contained malignant microcalcifications. After bootstrapping, free‐response receiver operating characteristics and receiver operating characteristics analyses were carried out. Performance between the two systems was compared at 0.98 and 0.95 specificity. At a specificity of 0.98, the sensitivity increased from 37% to 52% and the sensitivity increased from 62% up to 76% at a specificity of 0.95. Partial areas under the curve in the specificity range of 0.8–1.0 were significantly different between the system without BACs removal and the system with BACs removal, 0.129 ± 0.009 versus 0.144 ± 0.008 (ppp<0.05) sensitivity, respectively. Additionally, the CADe system with BACs removal reduces the number of false positives per case by 29% on average. The same sensitivity at one false positive per 50 cases in the CADe system without BACs removal can be achieved at one false positive per 80 cases in the CADe system with BACs removal.Conclusions: By using dedicated algorithms to detect and remove breast arterial calcifications, the performance of CADe systems can be improved, in particular, at false positive rates representative for operating points used in screening.