RHRené Hoffmann

René Hoffmann

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


René Hoffmann has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Christoph E. Nebel

    Fraunhofer-Institute for Applied Solid State Physics (IAF), Tullastraße 72, Freiburg 79108, Germany

    10 shared publications
  • Nianjun Yang

    Department of Chemistry, Hasselt University, 3590 Diepenbeek, Belgium

    9 shared publications
  • Armin Kriele

    Fraunhofer-Institute for Applied Solid State Physics (IAF), Tullastr. 72, Freiburg 79108, Germany

    8 shared publications
  • Waldemar Smirnov

    Fraunhofer-Institute for Applied Solid State Physics (IAF), Tullastr. 72, Freiburg 79108, Germany

    8 shared publications
  • Harald Obloh

    Fraunhofer-Institute for Applied Solid State Physics (IAF), Tullastraße 72, Freiburg 79108, Germany

    6 shared publications
  • Jakob Hees

    Fraunhofer Institute for Applied Solid State Physics (IAF), Freiburg 79108, Germany

    3 shared publications

Latest Publications

  • Open Access

    Wettability Investigations and Wet Transfer Enhancement of Large-Area CVD-Graphene on Aluminum Nitride

    by Marius Knapp, René Hoffmann, Volker Cimalla, Oliver Ambacher

    The two-dimensional and virtually massless character of graphene attracts great interest for radio frequency devices, such as surface and bulk acoustic wave resonators. Due to its good electric conductivity, graphene might be an alternative as a virtually massless electrode by improving resonator performance regarding mass-loading effects. We report on an optimization of the commonly used wet transfer technique for large-area graphene, grown via chemical vapor deposition, onto aluminum nitride (AlN), which is mainly used as an active, piezoelectric material for acoustic devices. Today, graphene wet transfer is well-engineered for silicon dioxide (SiO2). Investigations on AlN substrates reveal highly different surface properties compared to SiO2 regarding wettability, which strongly influences the quality of transferred graphene monolayers. Both physical and chemical effects of a plasma treatment of AlN surfaces change wettability and avoid large-scale cracks in the transferred graphene sheet during desiccation. Spatially-resolved Raman spectroscopy reveals a strong strain and doping dependence on AlN plasma pretreatments correlating with the electrical conductivity of graphene. In our work, we achieved transferred crack-free large-area (40 × 40 mm2) graphene monolayers with sheet resistances down to 350 Ω/sq. These achievements make graphene more powerful as an eco-friendly and cheaper replacement for conventional electrode materials used in radio frequency resonator devices.


  • Fractional Surface Termination of Diamond by Electrochemical Oxidation

    by René Hoffmann, Harald Obloh, Norio Tokuda, Nianjun Yang, Christoph E. Nebel

    The crystalline form of sp3-hybridized carbon, diamond, offers various electrolyte-stable surface terminations. The H-termination-selective attachment of nitrophenyl diazonium, imaged by AFM, shows that electrochemical oxidation can control the fractional hydrogen/oxygen surface termination of diamond on the nanometer scale. This is of particular interest for all applications relying on interfacial electrochemistry, especially for biointerfaces.


  • The creation of a biomimetic interface between boron-doped diamond and immobilized proteins

    by René Hoffmann, Armin Kriele, Harald Obloh, Norio Tokuda, Waldemar Smirnov, Nianjun Yang, Christoph E. Nebel


  • Integrated All-Diamond Ultramicroelectrode Arrays: Optimization of Faradaic and Capacitive Currents

    by Waldemar Smirnov, Nianjun Yang, René Hoffmann, Jakob Hees, Harald Obloh, Wolfgang Müller-Sebert, Christoph E. Nebel

    Integrated all-diamond ultramicroelectrode arrays (UMEAs) were fabricated using standard photolithography processes. The array consisted of typically 45 ultramicroelectrodes with a diameter of 10 μm and with a center-to-center spacing of 60 μm. The quasi-reference and counter electrodes were made from conductive diamond and were integrated on a 5 × 5 mm(2) chip. On the UMEA, a high ratio of faradaic current to capacitive current was achieved on heavily boron-doped and hydrogen-terminated diamond surfaces at slow scan rates and in high concentration of supporting electrolyte. A sensitive and reproducible detection of dopamine was achieved on hydrogen-terminated diamond UMEA at slow scan rates. The detection limit of dopamine in the presence of ascorbic acid was 1.0 nM, which is 50-100 times lower than that obtained on the macrosized boron-doped diamond electrodes. This array is promising for sensitive and reproducible detection of analytes in solutions with low detection limits.


  • Diamond ultra‐microelectrode arrays for achieving maximum Faradaic current with minimum capacitive charging

    by Nianjun Yang, Waldemar Smirnov, Jakob Hees, René Hoffmann, Armin Kriele, Harald Obloh, Wolfgang Müller‐Sebert, Christoph E. Nebel


  • Diamond-Modified AFM Probes: From Diamond Nanowires to Atomic Force Microscopy-Integrated Boron-Doped Diamond Electrodes

    by Waldemar Smirnov, Armin Kriele, René Hoffmann, Eugenio Sillero, Jakob Hees, Oliver A. Williams, Nianjun Yang, Christine Kranz, Christoph E. Nebel

    In atomic force microscopy (AFM), sharp and wear-resistant tips are a critical issue. Regarding scanning electrochemical microscopy (SECM), electrodes are required to be mechanically and chemically stable. Diamond is the perfect candidate for both AFM probes as well as for electrode materials if doped, due to diamond’s unrivaled mechanical, chemical, and electrochemical properties. In this study, standard AFM tips were overgrown with typically 300 nm thick nanocrystalline diamond (NCD) layers and modified to obtain ultra sharp diamond nanowire-based AFM probes and probes that were used for combined AFM–SECM measurements based on integrated boron-doped conductive diamond electrodes. Analysis of the resonance properties of the diamond overgrown AFM cantilevers showed increasing resonance frequencies with increasing diamond coating thicknesses (i.e., from 160 to 260 kHz). The measured data were compared to performed simulations and show excellent correlation. A strong enhancement of the quality factor upon overgrowth was also observed (120 to 710). AFM tips with integrated diamond nanowires are shown to have apex radii as small as 5 nm and where fabricated by selectively etching diamond in a plasma etching process using self-organized metal nanomasks. These scanning tips showed superior imaging performance as compared to standard Si-tips or commercially available diamond-coated tips. The high imaging resolution and low tip wear are demonstrated using tapping and contact mode AFM measurements by imaging ultra hard substrates and DNA. Furthermore, AFM probes were coated with conductive boron-doped and insulating diamond layers to achieve bifunctional AFM–SECM probes. For this, focused ion beam (FIB) technology was used to expose the boron-doped diamond as a recessed electrode near the apex of the scanning tip. Such a modified probe was used to perform proof-of-concept AFM–SECM measurements. The results show that high-quality diamond probes can be fabricated, which are suitable for probing, manipulating, sculpting, and sensing at single digit nanoscale.


  • Nanocrystalline Diamond Nanoelectrode Arrays and Ensembles

    by Jakob Hees, René Hoffmann, Armin Kriele, Waldemar Smirnov, Harald Obloh, Karlheinz Glorer, Brian Raynor, Rachid Driad, Nianjun Yang, Oliver A. Williams, et al.

    In this report, the fabrication of all-nanocrystalline diamond (NCD) nanoelectrode arrays (NEAs) by e-beam lithography as well as of all-diamond nanoelectrode ensembles (NEEs) using nanosphere lithography is presented. In this way, nanostructuring techniques are combined with the excellent properties of diamond that are desirable for electrochemical sensor devices. Arrays and ensembles of recessed disk electrodes with radii ranging from 150 to 250 nm and a spacing of 10 μm have been fabricated. Electrochemical impedance spectroscopy as well as cyclic voltammetry was conducted to characterize arrays and ensembles with respect to different diffusion regimes. One outstanding advantage of diamond as an electrode material is the stability of specific surface terminations influencing the electron transfer kinetics. On changing the termination from hydrogen- to oxygen-terminated diamond electrode surface, we observe a dependence of the electron transfer rate constant on the charge of the analyte molecule. Ru(NH3)6+2/+3 shows faster electron transfer on oxygen than on hydrogen-terminated surfaces, while the anion IrCl6−2/−3 exhibits faster electron transfer on hydrogen-terminated surfaces correlating with the surface dipole layer. This effect cannot be observed on macroscopic planar diamond electrodes and emphasizes the sensitivity of the all-diamond NEAs and NEEs. Thus, the NEAs and NEEs in combination with the efficiency and suitability of the selective electrochemical surface termination offer a new versatile system for electrochemical sensing.


  • Interface properties of cytochrome c on a nano-textured diamond surface

    by Nianjun Yang, Rene Hoffmann, Waldemar Smirnov, Christoph E. Nebel


  • Direct electrochemistry of cytochrome c on nanotextured diamond surface

    by Nianjun Yang, Rene Hoffmann, Waldemar Smirnov, Armin Kriele, Christoph E. Nebel


  • Adsorption of cytochrome c on diamond

    by René Hoffmann, Armin Kriele, Susanne Kopta, Waldemar Smirnov, Nianjun Yang, Christoph E. Nebel

    The adsorption and conformational state of the electron transfer protein cytochrome c (cyt c) on flat, boron doped polycrystalline diamond electrodes was investigated using electrochemical techniques and atomic force microscopy (AFM). An electrochemical reduction wave from the adsorbed protein was identified as oxygen reduction, which is catalysed by the deformed heme redox centre of cyt c. We show that this catalytic activity only occurs after partial denaturation of cyt c. Therefore the reduction peak was used for characterization of the conformational state of adsorbed cyt c. AFM characterizations with molecular resolution show different conformational states of cyt c on diamond surfaces ranging from native to denaturated. Both applied techniques indicate that hydrophobic hydrogenated diamond tends to denaturate cyt c upon adsorption, while wet chemically oxidized diamond surfaces can provide extensive but non‐denaturating cyt c adsorption. The conformation and orientation of cyt c on wet chemically oxidized diamond is beneficial for the electron transfer between the protein redox centre and the diamond electrode even in the presence of oxygen.