GBGoran I. Benic

Goran I. Benic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Goran I. Benic has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Monolithic Zirconia Versus Porcelain‐Fused‐to‐Metal Implant‐Supported Fixed Dental Prostheses in the Posterior Region: 3‐Year Results of a Randomized Controlled Clinical Trial

    by Aspasia Pachiou, Raphael Singh, Ronald E. Jung, Marc Balmer, Goran I. Benic, Alexis Ioannidis

    Objectives: To compare the clinical, biological, and technical outcomes of posterior three‐unit implant‐supported fixed dental prostheses (iFDPs) fabricated from monolithic zirconia (MonoZR) or porcelain‐fused‐to‐metal (PFM). Materials and Methods: In this prospective randomized controlled trial, partially edentulous patients requiring a posterior three‐unit iFDP supported by two implants were randomly assigned to MonoZR or PFM iFDPs. The primary outcome was ceramic fracture. Secondary outcomes included prosthesis survival, complication‐free survival, marginal bone level (MBL) changes, peri‐implant clinical parameters, and USPHS ratings. Follow‐up examinations were performed at 1 and 3 years. Statistical analyses included Kaplan–Meier estimates, Fisher's exact test, and linear mixed‐effects models ( α = 0.05). Results: Fifty‐five patients received iFDPs at baseline (MonoZR: n = 28; PFM: n = 27), and 45 completed the 3‐year follow‐up. Two prosthesis failures occurred, one in each group, both associated with implant loss, with no difference in survival between groups ( p = 1.00). Veneering ceramic chipping occurred only in the PFM group (3/23; 13%) and not in the MonoZR group (0/22) ( p = 0.11). Complication‐free survival, peri‐implant clinical parameters, and MBL changes did not differ significantly between groups ( p > 0.05). Plaque index and bleeding on probing increased over time, while probing depth and MBL remained stable. Both groups showed high clinical acceptability according to USPHS criteria. Conclusions: Both MonoZR and PFM posterior three‐unit iFDPs demonstrated high survival and favorable biological outcomes after 3 years. MonoZR showed no chipping events and may represent a promising alternative to PFM for posterior implant‐supported restorations. Trial Registration: German Clinical Trials Register: DRKS00011039

  • Open Access

    Effect of pseudo-periosteum on hard and soft tissue regeneration following lateral bone augmentation using a titanium mesh: an experimental in vivo study

    by Seung-Hyun Park, Kyeong-Won Paeng, So-Ra Yoon, Goran I. Benic, Daniel S. Thoma, Ui-Won Jung, Ronald E. Jung

    Park SH, et al. J Periodontal Implant Sci. 2026 ;56:e6. https://doi.org/10.5051/jpis.2504020201

  • Open Access

    Clinical performance of monolithic zirconia crowns on titanium–zirconium reduced‐diameter implants in the molar area: Interim data at three years of a randomized controlled trial

    by K. Zumstein, T. Waller, C. H. F. Hämmerle, R. E. Jung, G. Benic, S. Mühlemann

    Aim: The aim of the present study was (i) to evaluate the clinical performance of reduced‐diameter implants placed in the molar area and (ii) to test whether monolithic zirconia implant‐supported crowns lead to similar clinical outcomes compared to porcelain‐fused‐to‐metal crowns.Materials and Methods: A total of 76 patients needing a single implant crown in the posterior region were recruited. All patients received a titanium–zirconium reduced‐diameter implant (Straumann Roxolid, Tissue Level, Standard Plus, diameter 3.3 mm, regular neck) randomly allocated to receive either a (1) monolithic zirconia crown (test) or (2) porcelain‐fused‐to‐metal crown (control). Implant survival, prosthetic outcomes, and patient‐reported outcomes were assessed at crown delivery and after 3 years of follow‐up. Marginal bone levels (MBL) as well as clinical parameters including probing depth (PD), bleeding on probing (BOP), and plaque levels (PCR) were also recorded.Results: A total of 59 patients were available at the 3‐year follow‐up; 32 patients with a monolithic zirconia crown (TEST) and 27 patients with a porcelain‐fused‐to‐metal crown (CONTROL). 14 implants (11 implant fractures/3 aseptic losses) were lost leading to an estimated implant survival rate of 80% ± 5.1% (95% CI 70.8%–90.8%). Prosthetic complications were limited to the control group and involved minor chippings.Conclusions: This type of reduced‐diameter implant to support single implant molar crowns in the molar area cannot be recommended. Monolithic zirconia crowns appear to be a viable option in the posterior region showing similar prosthetic outcomes to porcelain‐fused‐to‐metal crowns.


  • Open Access

    Computer‐assisted bone augmentation, implant planning and placement: An in vitro investigation

    by S. Unger, G. I. Benic, A. Ender, P. Pasic, C. H. F. Hämmerle, B. Stadlinger

    Aim: To assess in vitro the workflow for alveolar ridge augmentation with customised 3D printed block grafts and simultaneous computer-assisted implant planning and placement. Methods: Twenty resin mandible models with an edentulous area and horizontal ridge defect in the region 34-36 were scanned with cone beam computed tomography (CBCT). A block graft for horizontal ridge augmentation in the region 34-36 and an implant in the position 35 were digitally planned. Twenty block grafts were 3D printed out of resin and one template for guided implant placement were stereolithographically produced. The resin block grafts were positioned onto the ridge defects and stabilised with two fixation screws each. Subsequently, one implant was inserted in the position 35 through the corresponding template for guided implant placement. Optical scans of the study models together with the fixated block graft were performed prior to and after implant placement. The scans taken after block grafting were superimposed with the virtual block grafting plan through a best-fit algorithm, and the linear deviation between the planned and the achieved block positions was calculated. The precision of the block fixation was obtained by superimposing the 20 scans taken after grafting and calculating the deviation between the corresponding resin blocks. The superimposition between the scans taken after and prior to implant placement was performed to measure a possible displacement in the block position induced by guided implant placement. The (98-2%)/2 percentile value was determined as a parameter for surface deviation. Results: The mean deviation in the position of the block graft compared to the virtual plan amounted to 0.79 +/- 0.13 mm. The mean deviation between the positions of the 20 block grafts measured 0.47 +/- 0.2 mm, indicating a clinically acceptable precision. Guided implant placement induced a mean shift of 0.16 +/- 0.06 mm in the position of the block graft. Conclusions: Within the limitations of this in vitro study, it can be concluded that customised block grafts fabricated through CBCT, computer-assisted design and 3D printing allow alveolar ridge augmentation with clinically acceptable predictability and reproducibility. Computer-assisted implant planning and placement can be performed simultaneously with computer-assisted block grafting leading to clinically non-relevant dislocation of block grafts.


  • Open Access

    Vertical bone augmentation using collagenated or non-collagenated bone substitute materials with or without recombinant human bone morphogenetic protein-2 in a rabbit calvarial model

    by Hyun-Chang Lim, Kyeong-Won Paeng, Ui-Won Jung, Goran I. Benic

    Lim HC, et al. J Periodontal Implant Sci. 2023 Mar;53:e7. https://doi.org/10.5051/jpis.2204240212


  • Soft‐tissue dimensional change following guided bone regeneration on peri‐implant defects using soft‐type block or particulate bone substitutes: 1‐year outcomes of a randomized controlled clinical trial

    by Young Woo Song, Stefan P. Bienz, Goran I. Benic, Jae‐Kook Cha, Christoph H. F. Hämmerle, Ui‐Won Jung, Ronald E. Jung

    Aim: To compare the peri‐implant soft‐tissue dimensional changes following guided bone regeneration between particulate (particle group) and collagenated soft‐block‐type (block group) biphasic calcium phosphate (BCP).Materials and Methods: This study investigated 35 subjects: 18 in the particle group and 17 in the block group. Cone‐beam computed tomography obtained at 6 months post surgery and optical impressions taken periodically (before surgery, 6 months post surgery, and 1 year post surgery) were superimposed. The ridge contour changes over time and the peri‐implant mucosal thicknesses were measured diagonally and horizontally, and analysed statistically.Results: The increases in diagonal (1.12 ± 0.78 mm) and horizontal (2.79 ± 1.90 mm) ridge contour of the block group were significantly higher than those in the particle group during the first 6 months (p < .05); however, the contour hardly changed thereafter (diagonal: 0.07 ± 0.75 mm; horizontal: −0.34 ± 1.26 mm), resulting in the 1‐year contour changes similar between the two groups. Regardless of the type of BCP, the ridge contour increased significantly over 1 year when the dehiscence defect had a contained configuration (p < .05).Conclusions: The increase in soft‐tissue dimensions for 1 year was similar between the two groups. The mucosal contour increase was larger when the surgery was conducted in a more contained defect, and this was not influenced by the type of BCP.


  • Randomized controlled clinical trial comparing guided bone regeneration of peri‐implant defects with soft‐type block versus particulate bone substitutes: Six‐month results of hard‐tissue changes

    by Goran I. Benic, Stefan P. Bienz, Young Woo Song, Jae‐Kook Cha, Christoph H. F. Hämmerle, Ui‐Won Jung, Ronald E. Jung

    Aim: To test whether soft‐type block bone substitute used for guided bone regeneration (GBR) of peri‐implant defects leads to a different dimension of the augmented hard tissue than particulate bone substitute.Materials and Methods: In 40 patients, 40 two‐piece dental implants were placed >2 months after tooth extraction. Following random allocation, 20 peri‐implant bone dehiscences were grafted with a soft‐type block made of synthetic biphasic calcium phosphate (BCP) + collagen and 20 bone dehiscences with particulate BCP. All the sites were covered with a collagen membrane stabilized with titanium pins. Immediately after wound closure and after 6 months, the horizontal dimension (HD) of the augmented hard tissue was measured at the level of implant shoulder using cone beam computed tomography. During re‐entry at 6 months, the defect fill was clinically assessed.Results: At 6 months, the median HD measured 1.15 mm (mean: 1.31 mm) in the soft‐block group and 0.93 mm (mean: 1.05 mm) in the particulate group (p = .6). At 6 months, 7.1% of contained defects and 61.9% of non‐contained defects showed an incomplete vertical defect fill.Conclusions: Soft‐type block of BCP + collagen used for GBR of peri‐implant defects did not differ from particulate BCP regarding the dimension of the augmented hard tissue after 6 months of healing.


  • Effect of collagen membrane and of bone substitute on lateral bone augmentation with titanium mesh: An experimental in vivo study

    by Kyeong‐Won Paeng, Jae‐Kook Cha, Daniel S. Thoma, Ronald E. Jung, Ui‐Won Jung, Goran I. Benic

    Aim: The aim of this study was to identify the additional effects of collagen membrane (CM) and of synthetic bone substitute (BS) on lateral bone augmentation of chronic peri‐implant defect with titanium mesh (TM).Materials and Methods: Atrophic alveolar ridge was induced in six canine mandibles, and 5 peri‐implant defects were achieved in each hemi‐mandible. Bone augmentation was attempted using the following randomly allocated modalities: (1) Control: no treatment, (2) TM only group: blood clot covered by TM, (3) TM+BS group: BS covered by TM, (4) TM+CM group: blood clot covered by TM and CM, and (5) TM+BS+CM group: BS covered by TM and CM. After 16 weeks of submerged healing, micro‐CT and histomorphometric analyses were performed.Results: TM exposure occurred in one case in the TM only group, one case in the TM+CM group, and two cases in the TM+BS+CM group. Histologically, pseudo‐periosteum was observed along the inner and outer surfaces of TM, and the directions of the collagen fiber within the pseudo‐periosteum differed according to the additional use of CM. In general, the TM only group rendered higher values in vertical defect fill and dimension of the augmented hard tissue in comparison with the other treatment groups.Conclusions: Due to the small sample size, this pilot study remains inconclusive. Within the limitations of the study, the use of CM and/or BS did not appear to have an additional benefit on lateral bone augmentation of peri‐implant defect with TM.


  • Effectiveness of xenogeneic and synthetic bone‐block substitute materials with/without recombinant human bone morphogenetic protein‐2: A preclinical study using a rabbit calvarium model

    by Hyun‐Chang Lim, Kyeong‐Won Paeng, Ui‐Won Jung, Goran I. Benic

    Aim: To investigate new bone (NB) formation by using bone‐block substitute materials with/without recombinant human bone morphogenetic protein‐2 (rhBMP‐2).Materials and Methods: Three synthetic bone‐block substitute materials [biphasic calcium phosphate (BCP); nanostructured hydroxyapatite (NH); 3D‐printed tricalcium phosphate/hydroxyapatite (3DP)] and one xenogeneic deproteinized bovine bone mineral (DBBM) block substitute were affixed to rabbit calvarium using osteosynthesis screws, either with rhBMP‐2 (n = 12) or without rhBMP‐2 (n = 16). At 2 or 12 weeks (n = 6 with rhBMP‐2 and n = 8 without rhBMP‐2 for each week), histologic, histomorphometric and microcomputed tomography analyses were performed.Results: The application of rhBMP‐2 increased NB formation in all experimental groups at both weeks. DBBM resulted in a greater area of NB compared with synthetic blocks either with or without rhBMP‐2 at 2 weeks (2.8 ± 0.9 vs. 1.4 ± 0.5–1.9 ± 1.4 mm2; 1.4 ± 1.0 vs. 0.6 ± 0.3–0.9 ± 0.5 mm2) and without rhBMP‐2 at 12 weeks (3.0 ± 0.8 vs. 1.7 ± 0.7–2.6 ± 1.5 mm2) (p > 0.05). NB formation did not differ significantly for DBBM and the three types of synthetic block with rhBMP‐2 at 12 weeks (4.5 ± 2.0 vs. 3.8 ± 0.7–5.1 ± 1.1 mm2; p > 0.05).Conclusions: rhBMP‐2 enhanced NB in all blocks. DBBM blocks yielded more NB than synthetic blocks without rhBMP‐2. The application of rhBMP‐2 appears to compensate for differences in late healing.


  • Prosthetic outcomes and clinical performance of CAD‐CAM monolithic zirconia versus porcelain‐fused‐to‐metal implant crowns in the molar region: 1‐year results of a RCT

    by Sven Mühlemann, Tabrez Lakha, Ronald E. Jung, Christoph H. F. Hämmerle, Goran I. Benic

    Objective: To investigate the clinical performance of monolithic zirconia implant crowns as compared to porcelain‐fused‐to‐metal (PFM) implant crowns.Materials and methods: Seventy‐six healthy patients received reduced diameter implants in the molar region. Following random allocation, either a monolithic zirconia crown (Mono‐ZrO2) or a (PFM) was inserted. Crown and implant survival rates, modified USPHS criteria, clinical measurements, and interproximal marginal bone level (MBL) were assessed at crown delivery (baseline, BL) and at the 1‐year follow‐up (1y‐FU). Data were analyzed descriptively. Fisher's exact test and Wilcoxon rank sum test were applied for statistical analysis. The level of statistical significance was set at p < .05.Results: Thirty‐nine Mono‐ZrO2 and 37 PFM crowns were delivered. At the 1y‐FU, one crown in each group was lost due to loss of the implant. Technical complications occurred in the PFM group and were limited to four minor ceramic chippings resulting in a total technical complication rate of 11.1% (p = .024). Anatomical form and color match compared to the adjacent dentition were rated significantly inferior for the Mono‐ZrO2 crowns. Patient satisfaction was high in both groups at BL (34 Mono‐ZrO2 34 PFM) and at 1y‐FU (36 Mono‐ZrO2 31 PFM). No significant differences between the groups were detected with respect to the change in MBL and to the soft tissue parameters.Conclusions: Monolithic zirconia crowns are a similarly successful alternative option to PFM crowns for restoring single implants in the posterior area.