JJJulien De Jonckheere

Julien De Jonckheere

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Julien De Jonckheere has a total of 93 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Time and frequency characteristics of various noninvasive heartbeat sensors

    by Pierre Charlier, Mathieu Jeanne, Maxence Hureau, Julien De Jonckheere

    Heart rate and cardiac dynamics can be monitored using several physiological signals, each with its own biophysical basis and signal characteristics. However, while individual properties of electrocardiogram (ECG), phonocardiogram (PCG), seismocardiogram (SCG), photoplethysmogram (PPG), and piezoplethysmogram (PiPG) are documented, systematic cross-modal comparisons remain scarce. This study aims to consolidate both the time and frequency domain features of these widely accessible technologies to provide practical guidelines for signal processing and multimodal integration. We simultaneously recorded ECG, PCG, SCG, PPG, and PiPG under standardized resting conditions and aligned all modalities on the ECG R-peak. Results highlight clear consistencies (e.g., reproducible morphology and spectra for ECG, PPG, and PiPG) as well as higher variability in PCG and SCG due to sensor coupling and anatomical factors. Temporal latencies relative to the ECG confirm known physiological conduction delays, while frequency analysis identifies modality-specific bands: ~ 30 Hz for PCG, 11–14 Hz for SCG, and 1–2 Hz for PPG/PiPG. Bandwidth analysis further emphasizes differences in spectral richness across modalities. By presenting these benchmarks in a unified framework, this work addresses the current gap between isolated characterizations and integrated signal knowledge. The outcome is a reference dataset and interpretation map that can guide filtering strategies, feature extraction, and the design of multimodal cardiac monitoring systems.

  • Open Access

    Clinical efficacy and safety of automatic remifentanil administration based on Analgesia Nociception Index monitoring during burn surgery under propofol anesthesia: A randomized controlled clinical trial

    by Maxence Hureau, Emeline Caillau, Julien Labreuche, Mathilde Herbet, Benoît Tavernier, Julien De Jonckheere, Mathieu Jeanne

    Background: Monitoring the nociception/antinociception balance for analgesic guidance during general anesthesia may improve the quality of anesthesia. The University Hospital of Lille (France) has developed an expert software system for automatic remifentanil administration based on the continuous monitoring of the Analgesia Nociception Index (MDoloris, France). We assessed the clinical efficacy and safety of the ANI-REMI-LOOP “expert-system software” during burn surgery in a monocentric randomized controlled trial. Methods: The trial was approved by the French Ethics Committee, and all patients gave written informed consent. From 2018 to 2022, 52 adults were randomized into two groups: manual remifentanil infusion (standard practice) or automatic remifentanil infusion (expert-system software) during BIS-guided propofol anesthesia at the burn center of the hospital. In the standard practice group, remifentanil administration was based on Minto’s model and guided by the analgesia nociception index. In both groups, propofol was administered based on Schnider’s model and guided by the BiSpectral Index (Covidien). The primary endpoint was the cumulative remifentanil dose administered during anesthesia and secondary endpoints were related to the clinical safety of automatic remifentanil administration with the incidence and duration of hypotension, bradycardia, hypertension or tachycardia related to nociception. After anesthesia, the endpoints were pain and analgesic requirements during 2 hours. A p value < 0.05 was considered statistically significant. Data are presented as median [1st to 3rd quartile]. Results: The cumulative remifentanil dose was significantly lower in the automatic group 0.125 µg.kg-1.min-1 [0.106 to 0.149] vs. 0.152 µg.kg-1.min-1 [0.137 to 0.237], p = 0.004), and the cumulative proportion of time with hemodynamic impairment or reactivity was significantly lower in the expert-system automatic group 4.2% [2.5 to 5.7] vs. 19.4% [6.9 to 59.9], p = 0.010). There were no safety issues, and pain and analgesic requirements were similar in both groups after surgery. Conclusions: Automatic remifentanil administration demonstrated good clinical performances during propofol anesthesia for burn surgery. It is likely that these results can be extrapolated to any surgical setting under general anesthesia, but this needs to be tested with further randomized clinical trials.


  • Open Access

    The Development of a Forceps-Adaptable Pressure Device for Instrumental Delivery: A Proof-of-Concept Study for Clinical and Educational Applications

    by Mathieu Hivert, Cyril Bengler, Julien De Jonckheere, Franck Gaultier, Marie Pécout, Olivier Mayeur, Chrystèle Rubod

    Objective: To develop and validate a device that measures the pressure exerted by forceps on the fetal head for clinical use. Background: The lack of clinical tools to quantify forceps pressure on the fetal head may impact maternal and neonatal outcomes. Existing studies have not measured the direct contact pressure between forceps blades and the fetal head, highlighting the need for innovation. Methods: We integrated fluid pressure transducers into obstetric forceps using fluid-filled tubing encased in flexible silicone socks attached to the blades. Tubing materials—polyvinyl chloride (PVC) and polyurethane (PU)—and fluids (air and water) were tested with both biocompatible and non-biocompatible silicone socks. An onboard electronic board collected pressure data and transmitted them via Bluetooth for real-time analysis. The system was evaluated on a custom-built bench simulating forceps application. Results: Air-filled tubing exhibited significant drift and low accuracy due to air compressibility. Water-filled PU tubing reduced drift but was still suboptimal. Water-filled PVC tubing with both types of silicone socks provided the best results, showing minimal drift and a strong correlation between measured pressures and applied forces. Conclusions: The developed device represents a significant advancement, as no existing system measures the pressure exerted by forceps blades on the fetal head. By effectively measuring pressure across the entire contact surface in real time, it offers applications in both training and clinical practice. The device allows for objective feedback, potentially improving the safety and efficacy of forceps deliveries. Future work includes comprehensive mannequin tests and eventual in vivo studies to validate its effectiveness in realistic settings, aiming to enhance obstetric training and reduce maternal and neonatal complications.


  • Open Access

    Efficiency and Impact of Hypnoanalgesia for Cardiac Catheterisation in Paediatric Population

    by Pierre-Alexandre Fontanges, Julien Haudiquet, Julien De Jonkheere, Alexandre Delarue, Olivia Domanski, Thameur Rakza, Sebastien Hascoet, Said Bichali, Jean Benoit Baudelet, Francois Godart, et al.

    Hypnoanalgesia is a promising non-pharmacologic adjunct technique in paediatric interventions. Its safety, efficiency, and impacts on paediatric cardiac catheterisation (CC) are unknown. Methods: In a prospective study, patients aged p = 0.62). No complications were reported. Conclusion: Paediatric CC is feasible and safe under hypnoanalgesia, even in complicated cases. Hypnoanalgesia was efficient in managing pain and stress, and it ensures more reliable pressure measurements.


  • Open Access

    Changes in Umbilico–Placental Circulation during Prolonged Intact Cord Resuscitation in a Lamb Model

    by Kévin Le Duc, Estelle Aubry, Sébastien Mur, Capucine Besengez, Charles Garabedian, Julien De Jonckheere, Laurent Storme, Dyuti Sharma

    Some previous studies reported a benefit to cardiopulmonary transition at birth when starting resuscitation maneuvers while the cord was still intact for a short period of time. However, the best timing for umbilical cord clamping in this condition is unknown. The aim of this study was to explore the duration of effective umbilico–placental circulation able to promote cardiorespiratory adaptation at birth during intact cord resuscitation. Umbilico–placental blood flow and vascular resistances were measured in an experimental neonatal lamb model. After a C-section delivery, the lambs were resuscitated ventilated for 1 h while the cord was intact. The maximum and mean umbilico–placental blood flow were respectively 230 ± 75 and 160 ± 12 mL·min−1 during the 1 h course of the experiment. However, umbilico–placental blood flow decreased and vascular resistance increased significantly 40 min after birth (p < 0.05). These results suggest that significant cardiorespiratory support can be provided by sustained placental circulation for at least 1 h during intact cord resuscitation.


  • The newborn infant parasympathetic evaluation in pediatric and neonatology: a literature review

    by Morgan Recher, Mohamed Riadh Boukhris, Mathieu Jeanne, Laurent Storme, Stéphane Leteurtre, Nada Sabourdin, Julien De Jonckheere

    Purpose The Newborn Infant Parasympathetic Evaluation (NIPE) is a heart rate variability-based technology for assessing pain and comfort in neonates and infants under 2-years-old. This review aims to investigate the clinical utility of the NIPE. Methods Two investigators screened Pubmed/Medline and Google Scholar for relevant studies, independently. One investigator extracted data, which were reviewed by a second investigator. Results The NIPE was used during/after painful stimuli (6 studies), in the context of general anaesthesia (2 studies), and for comfort assessment (6 studies). A) Evaluation of procedural pain/distress: 2 studies reported that the mean-NIPE could be used for reliable monitoring of prolonged pain, and one study reported the association between instant-NIPE and pain after a stimulus but the instant-NIPE represents the NIPE average over 3 min. Two studies found no correlation between the NIPE and comfort behavior/pain scales, but they mainly differed in patients’ gestational age and evaluation methodology. B) There are only 2 studies for the evaluation of nociception during surgery under general anaesthesia with contradictory results. C) Studies assessing neonates’ comfort reported increased NIPE scores during skin-to-skin contact and during facilitated tucking associated with a human voice. No effect on NIPE scores of facilitated tucking during echocardiography was reported in preterm infants. One study reported significantly different NIPE scores with 2 surfactant therapy protocols. Overall, study populations were small and heterogeneous. Conclusion The results regarding NIPE’s performances differ between studies. Given the limited number of studies and the heterogeneous outcomes, more studies are required to confirm the NIPE usefulness in the different clinical settings.


  • Autonomic response to fetal acidosis using an experimental sheep model

    by Roxane Vanspranghels, Julien De Jonckheere, Elodie Drumez, Arthur Lauriot Dit Prevost, Dyuti Sharma, Louise Ghesquiere, Laurent Storme, Véronique Houfflin-Debarge, Charles Garabedian


  • Comparison of multiple cardiac signal acquisition technologies for heart rate variability analysis

    by P. Charlier, M. Cabon, C. Herman, F. Benouna, R. Logier, V. Houfflin-Debarge, M. Jeanne, J. De Jonckheere

    Heart rate variability analysis is a recognized non-invasive tool that is used to assess autonomic nervous system regulation in various clinical settings and medical conditions. A wide variety of HRV analysis methods have been proposed, but they all require a certain number of cardiac beats intervals. There are many ways to record cardiac activity: electrocardiography, phonocardiography, plethysmocardiography, seismocardiography. However, the feasibility of performing HRV analysis with these technologies and particularly their ability to detect autonomic nervous system changes still has to be studied. In this study, we developed a technology allowing the simultaneous monitoring of electrocardiography, phonocardiography, seismocardiography, photoplethysmocardiography and piezoplethysmocardiography and investigated whether these sensors could be used for HRV analysis. We therefore tested the evolution of several HRV parameters computed from several sensors before, during and after a postural change. The main findings of our study is that even if most sensors were suitable for mean HR computation, some of them demonstrated limited agreement for several HRV analyses methods. We also demonstrated that piezoplethysmocardiography showed better agreement with ECG than other sensors for most HRV indexes.