AHAmber Haseeb

Amber Haseeb

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amber Haseeb has a total of 21 co-authors. Here are the top co-authors by number of shared publications:

  • Vivek Ajit Singh

    Department of Orthopaedic Surgery (NOCERAL), Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia

    7 shared publications
  • Cindy Shuan Ju Teh

    Department of Medical Microbiology, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia

    2 shared publications
  • Nor Faissal Yasin

    Department of Orthopaedic Surgery (NOCERAL), Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia

    2 shared publications
  • Rukmanikanthan Shanmugam

    Department of Orthopaedic Surgery, National Orthopaedic Center of Excellence for Research & Learning, University of Malaya, Kuala Lumpur, Malaysia

    2 shared publications
  • Vivek Ajit Singh

    Department of Orthopaedic Surgery, Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia

    2 shared publications
  • Bong Chun Haw

    Department of Orthopaedic Surgery (NOCERAL), Faculty of Medicine, University of Malaya, Kuala Lumpur, Malaysia

    1 shared publication

Latest Publications

  • Open Access

    Alteration of foot loading pattern in patients with lower limb endoprothesis surgery and functional outcome: A pilot study

    by Vivek Ajit Singh, Hartharanjeet Singh Phinder, Amber Haseeb, Rupini Devi Santharalinggam, Nor Faissal Yasin

    Introduction: Endoprosthetic reconstruction is a widely used technique; however, it is associated with various postoperative complications. One often overlooked complication is the alteration of foot loading patterns. This pilot study evaluated functional outcomes with postoperative static foot loading patterns in patients undergoing endoprosthesis replacements compared to the contralateral limb. Objective: This study evaluates static foot loading patterns in patients undergoing endoprosthetic replacements. It explores the relationship between the functional outcomes of the operated limb and foot loading patterns in a standing position. Additionally, the study considers factors such as the anatomical location of the endoprosthetic reconstruction, limb length discrepancy, age, gender, and body mass index (BMI). Materials and Methods: This prospective cross-sectional study included 100 patients over 15 years who had undergone lower limb endoprosthetic reconstruction at least 1 year prior and could walk unaided. Data collection encompassed patient demographics, diagnosis, anthropometric measurements, postoperative functional status (evaluated using AOFAS-Hindfoot, MSTS, and TESS scores), and postoperatively analysis of foot loading patterns. Results: The patient group has a significantly higher prevalence of abnormal foot arches compared to the expected population proportion. Notably, 10% of patients transitioned from a normal arch to flatfoot, while 40% developed a high arch post-surgery. Asymmetrical arches were observed in 30 patients. Post-surgery, 18.5% of patients experienced a transition from a normal foot arch to a high arch, and 4.6% transitioned to flatfoot. Analysis of variables such as surgical site, limb length discrepancy, age, gender, BMI, foot loading patterns and functional scores (MSTS, TESS and AOFAS) showed no significant associations with these changes. Conclusion: Although no significant correlation was identified between functional scores and foot loading patterns following lower limb endoprosthetic surgery, a notable prevalence of abnormal foot arches was observed. We recommend routine podiatry consultations for these patients to address and manage potential foot-related complications.

  • Open Access

    Functional outcome following excision of giant cell tumour of the distal radius and reconstruction by autologous non-vascularized osteoarticular fibula graft

    by Vivek Ajit Singh, Koh Teck Wei, Amber Haseeb, Nor Faissal Yasin

    Purpose: Giant cell tumour (GCT) of the bone is a benign but locally aggressive tumour, commonly occurs at the metaphyseal–epiphyseal junction of the distal femur, proximal tibia, and distal radius. For Campanacci grade II and III lesions of the distal radius and in cases of recurrence, we usually carry out wide resection and reconstruction. There are numerous publications on the treatment of GCT of the distal radius. Still, reports on the functional outcome using non-vascularized fibular graft arthroplasty without fusion remain limited. Method: We reviewed patients who underwent wide resection and non-vascularized fibular graft arthroplasty from 2007 to May 2014. The assessment was done with Musculoskeletal Tumour Society Score (MSTS), Toronto Extremities Scoring System (TESS) and Disability of the Arm, Shoulder and Hand (DASH) scores. We also reviewed the radiographic results. Results: Fifteen patients were recruited, of whom 10 cases used ipsilateral fibular graft and five used contralateral non-vascularized fibular graft. The average duration of follow up was 6 years (3.25–9.92 years). The average grip strength was 48.1% compared to the non-operated hand. The average MSTS score was 78.4 %, TESS score was 84%, and DASH score was 25.2. The average time to radiological union was 12.5 weeks. 64% (29–78%) of the range of movement is preserved compared to the normal side. The complication rate was 20%. Conclusion: Fibula autograft arthroplasty is a feasible method of reconstruction after distal radius resection with good functional outcomes.


  • Open Access

    Predictor index of functional limb length discrepancy

    by Vivek Ajit Singh, Sasidaran Ramalingam, Amber Haseeb, Nor Faissal Bin Yasin

    Introduction: Limb length discrepancy (LLD) of lower extremities is underdiagnosed due to compensatory mechanisms during locomotion. The natural course of compensation leads to biomechanical alteration in human musculoskeletal system leading to adverse effects. General consensus accepts LLD more than 2 cm as significant to cause biomechanical alteration. No studies were conducted correlating height and lower extremities true length (TL) to signify LLD. Examining significant LLD in relation to height and TL using dynamic gait analysis with primary focus on kinematics and secondary focus on kinetics would provide an objective evaluation method. Methodology: Forty participants with no evidence of LLD were recruited. Height and TL were measured. Reflective markers were attached at specific points in lower extremity and subjects walked in gait lab at a self-selected normal walking pace with artificial LLDs of 0, 1, 2, 3, and 4 cm simulated using shoe raise. Accommodation period of 30 min was given. Infrared cameras were used to capture the motion. Primary kinematic (knee flexion and pelvic obliquity (PO)) and secondary kinetic (ground reaction force (GRF)) were measured at right heel strike and left heel strike. Functional adaptation was analyzed and the postulated predictor indices (PIs) were used as a screening tool using height, LLD, and TL to notify significance. Results: There was a significant knee flexion component seen in height category of less than 170 cm. There was significant difference between LLD 3 cm and 4 cm. No significant changes were seen in PO and GRF. PIs of LLD/height and LLD/TL were analyzed using receiver operating characteristic curve. LLD/height as a PI with value of 1.75 was determined with specificity of 80% and sensitivity of 76%. Conclusion: A height of less than 170 cm has significant changes in relation to LLD. PI using LLD/height appears to be a promising tool to identify patients at risk.


  • Open Access

    Addition of ceftaroline fosamil or vancomycin to PMMA: An in vitro comparison of biomechanical properties and anti-MRSA efficacy

    by Amber Haseeb, Vivek Ajit Singh, Cindy Shuan Ju Teh, Mun Fai Loke

    Ceftaroline is a cephalosporin that is effective against methicillin-resistant Staphylococcus aureus (MRSA) infections. The objective of this study was to determine the feasibility of using ceftaroline-loaded Polymethyl methacrylate (PMMA) as antibiotic cement against MRSA versus vancomycin-loaded PMMA in an in vitro setting. PMMA pellets were prepared with three separate concentrations of each of the two antibiotics tested. They were tested to determine the effect of increasing concentration of antibiotics on the biomechanical properties of PMMA and antibiotic activity by measuring the zone of inhibition and broth elution assay. Ceftaroline PMMA at 3 wt%, three-point bending was 37.17 ± 0.51 N (p < 0.001) and axial loading was 41.95 N ± 0.51 (p < 0.001). At 5-wt% vancomycin-PMMA, three-point bending was 41.65 ± 0.79 N (p = 0.02) and axial loading was 49.49 ± 2.21 N (p = 0.01). Stiffness of ceftroline-loaded PMMA in low and medium concentration was significantly higher than the vancomycin. The zone of inhibition for ceftaroline was higher than vancomycin. Ceftaroline at 3 wt% eluted up to 6 weeks (0.3 ± 0.1 μg/ml) above the minimum inhibitory concentration (MIC) and vancomycin at 2.5 wt% eluted up to 3 weeks, same as MIC, that is, 0.5 ± 0.0 μg/ml. Ceftaroline, loaded at similar concentrations as vancomycin into PMMA, is a more potent alternative based on its more favourable bioactivity and elution properties, while having a lesser effect on the mechanical properties of the cement. The use of 3-wt% ceftaroline as antibiotic laden PMMA against MRSA is recommended. It should be noted that this was an in vitro study and to determine the clinical efficacy would need prospective, controlled and randomized studies.


  • Open Access

    Outcome of expandable endoprosthesis: A single centre retrospective review

    by Vivek Ajit Singh, Dinesh Earnest Kunasingh, Amber Haseeb, Nor Faissal Yasin

    Purpose: Expandable endoprosthesis allows limb salvage in children with an option to leading a better life. However, the revision rate and implant-related complications impose as a limitation in the skeletal immature. This study investigates the functional outcomes and complications related to expandable endoprosthesis in our centre. Materials and Methods: Twenty surviving patients with expandable endoprosthesis from 2006 till 2015 were scored using Musculoskeletal Tumour Society (MSTS) outcomes instrument and reviewed retrospectively for range of motion of respected joints, limb length discrepancy, number of surgeries performed, complications and oncological outcomes. Patients with less than 2 years of follow-up were excluded from this study. Results: Forty-five percentage patients reached skeletal maturity with initial growing endoprosthesis and 25% of patients were revised to adult modular prosthesis. One hundred fifty-seven surgeries were performed over the 9-year period. The average MSTS score was 90.83%. The mortality rate was 10% within 5 years due to advanced disease. Infection and implant failure rate was 15% each. The event-free survival was 50% and overall survival rate was 90%. Conclusion: There is no single best option for reconstruction in skeletally immature. This study demonstrates a favourable functional and survival outcome of paediatric patients with expandable endoprosthesis. The excellent MSTS functional scores reflect that patients were satisfied and adjusted well to activities of daily living following surgery despite the complications.


  • Open Access

    Hand-mixed vancomycin versus commercial tobramycin cement revisited: A study on mechanical and antibacterial properties

    by Vivek Ajit Singh, Bong Chun Haw, Amber Haseeb, Cindy Shuan Ju Teh

    Purpose: Arthroplasty-related infection has grown worldwide. Revision procedures for infection are associated with longer operating time, superior amounts of blood loss, and substantial economic encumbrance. To overcome cost, many surgeons opt for hand-mixed vancomycin into the bone cement. The objective of this research was to assess the biomechanical strength and antibacterial properties of hand-mixed vancomycin bone cement at different concentrations with commonly used industrial preblended antibiotic bone cement and plain cement. The target was to determine the ideal concentration of antibiotics that can be used in the preparation of hand-mixed vancomycin cement that delivers maximum antibiotics concentration without compromising its biomechanical properties. Materials and Methods: Vancomycin-impregnated polymethyl methacrylate (PMMA) specimen was hand prepared in varying concentrations (1–4 g). The authors tested three-point bending strength to determine ‘maximum bending load’ and stiffness and its antibacterial activity by looking into the zone of inhibition on methicillin-resistant Staphylococcus aureus -impregnated agar plate. These were compared with the industrial preblended Simplex™ P with 1 g tobramycin. Results: This study exhibited that vancomycin-PMMA disk that contained higher concentration of antibiotics had significantly higher antibacterial activity. The control group (plain cement) and industrial PMMA with preblended antibiotic (tobramycin) showed stable mechanical strength, while the hand-mixed antibiotic cement (HMAC) had variable mechanical strength varying on the concentration of antibiotics used. Conclusion: It was effectively concluded that HMAC is advantageous as a cement spacer; however, it is not recommended for primary arthroplasty and second-stage revision arthroplasty. The recommended maximum concentration of vancomycin based on this study is 2 g/pack (40 g) of cement. Industrial preblended antibiotic cement is superior to hand-mixed cement.


  • Open Access

    JectOS® versus PMMA vancomycin-loaded cement: The biomechanical and antimicrobial properties

    by Vivek Ajit Singh, Chang Chee Wei, Amber Haseeb, Rukmanikanthan Shanmugam, Cindy Shuan Ju

    Purpose: Bone cement is commonly used as a void filler for bone defects. Antibiotics can be added to bone cement to increase local drug delivery in eradicating infection. After antibiotic elution, nonbiodegradable material becomes an undesirable agent. The purpose of this study was to evaluate effects of addition of vancomycin on the compressive strength of injectable synthetic bone substitute, JectOS®. JectOS, a partially biodegradable cement that over time dissolves and is replaced by bone, could be potentially used as a biodegradable antibiotic carrier. Methods: Vancomycin at various concentrations was added to JectOS and polymethyl methacrylate (PMMA). Then, the cement was molded into standardized dimensions for in vitro testing. Cylindrical vancomycin–JectOS samples were subjected to compressive strength. The results obtained were compared to PMMA-vancomycin compressive strength data attained from historical controls. The zone of inhibition was carried out using vancomycin-JectOS and vancomycin-PMMA disk on methicillin-resistant strain culture agar. Results: With the addition of 2.5%, 5%, and 10% vancomycin, the average compressive strengths reduced to 8.01 ± 0.95 MPa (24.6%), 7.52 ± 0.71 MPa (29.2%), and 7.23 ± 1.34 MPa (31.9%). Addition of vancomycin significantly weakened biomechanical properties of JectOS, but there was no significant difference in the compressive strength at increasing concentrations. The average diameters of zone of inhibition for JectOS-vancomycin were 24.7 ± 1.44 (2.5%) mm, 25.9 ± 0.85 mm (5%), and 26.8 ± 1.81 mm (10%), which outperformed PMMA. Conclusion: JectOS has poor mechanical performance but superior elution property. JectOS-vancomycin cement is suitable as a void filler delivering high local concentration of vancomycin. We recommended using it for contained bone defects that do not require mechanical strength.


  • Open Access

    Ceftaroline fosamil laden allograft: A new modality in reducing infection?

    by Vivek Ajit Singh, Lim Han Sim, Amber Haseeb, Cindy Teh Shuan Ju

    Allograft infection remains the greatest challenge in orthopaedic reconstructive surgery especially methicillin-resistant Staphylococcus aureus (MRSA). This risk can be minimized with the use of antibiotic laden allograft (ALA) via iontophoresis. Ceftaroline fosamil (CF) is an advanced-generation cephalosporin, an alternative treatment for MRSA infections. Its antibacterial activity and safety profile are better than vancomycin. CF iontophoresed bone has not been used before. This study was conducted to establish the feasibility of creating a CF ALA and establish the prime conditions for its expenditure. We created an iontophoresis cell; 3% CF was inserted within medullary segment of goat bone and sealed from external saline solution. The cell operated at the following voltages 30, 60 and 90 V and at the following durations 5, 10, 15, 20, 25 and 30 min. Information regarding optimal conditions for its application was then obtained. After which, correlation between voltages and time with CF concentration in the bone was analysed. A bioavailability test was also conducted to observe the optimal rate of CF elution from the graft. The optimal condition for the impregnation process is 3% CF at 90 V for 10 min. Bone graft impregnated with CF at optimal conditions can elute above minimum inhibitory concentration of the CF against MRSA for 21 days. CF iontophoresis was found feasible for allograft impregnation. The technique is simple, inexpensive and reproducible clinically. Iontophoresis offers a novel solution to reduce the rate of perioperative infection in reconstructive surgery involving use of bone graft.


  • Open Access

    Comparing biomechanical strength of unicortical locking plate versus bicortical compression plate for transverse midshaft metacarpal fracture

    by Rukmanikanthan Shanmugam, Chong Yin [Email Protected] Chong Shyh Jian, Amber Haseeb, Saw Aik

    Purpose: Metacarpal bone fractures constitute 10% of all fractures. Unstable metacarpal fractures require surgical intervention, which poses danger to flexor tendon either due to bicortical drilling or construct of the implant. Unicortical locking plate fixation may be the solution to preventing flexor tendon injury. Studies have compared locking and compression plates. However, in these studies, the biomechanical properties were tested using the static loading method. This study looks into cyclical loading that is more representative of in vivo conditions, particularly for early rehabilitation. We compared the biomechanical strength of the unicortical locking plate and bicortical compression plate system in a transverse metacarpal fracture, tested with cyclical loading and torsion. Method: Twenty pieces of fourth-generation, biomechanical testing grade, left third metacarpal composite bones were used. Resin was used to create the holding block at both ends of the bone. An oscillating saw with 0.8 mm thick saw blade was used to osteotomize the metacarpal sawbones to create a midshaft transverse metacarpal fracture model. Ten pieces were fixed with a 2.0 mm titanium locking plate via unicortical screw purchase and 10 were fixed with a 2.0 mm, four holes, titanium dynamic compression plate, bicortical purchase of screws. They were subjected to cyclic load to failure testing three-point bending and torsion. Results: There were no significant difference in stiffness and cyclic three-point bending to failure between the unicortical locking plate group and the bicortical compression plate group. The bicortical compression plate group is stiffer and has a higher cyclic bending load to failure as compared to the unicortical locking plate group. Conclusion: Unicortical locking plate fixation of metacarpal fracture can be reliably applied clinically to produce a strong and stable construct that allows early mobilization of the joints. This will not only reduce the complication rate of metacarpal plating, but also improve the functional outcome of the hand.


  • Open Access

    Gouty Tophi Mimicking Synovial Sarcoma of the Knee Joint

    by Haseeb Amber, Vivek Ajit Singh, Mansor Azura

    Deposition of tophi is a common complication of chronic gout; however, symptoms are not always well pronounced. In this article, we report an unusual case of intraarticular gouty tophi of the knee joint presenting as a locked knee and radiologically mimicking a synovial sarcoma. To our knowledge, gouty tophus causing such a complication (fixed flexion deformity) has not been reported. This case report serves to bring about awareness of an extraordinary presentation of gout, which in severe forms can mimic intraarticular tumors and bring about such a deformity.