JSJames Richard Spears

James Richard Spears

*This is an algorithmically generated author record based on publicly available information.

James Richard Spears has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Petar Prcevski

    3 shared publications
  • Giles J. Brereton

    2 shared publications
  • Richard J. Crilly

    From the Cardiovascular Research Laboratory, Department of Medicine, Division of Cardiology, Harper Hospital/Wayne State University School of Medicine, Detroit, and the Department of Mechanical Engineering, Michigan State University, Lansing (G.J.B.), Mich

    2 shared publications
  • Richard Vander Heide

    2 shared publications
  • Ali D. Spanta

    From the Cardiovascular Research Laboratory, Department of Medicine, Division of Cardiology, Harper Hospital/Wayne State University School of Medicine, Detroit, and the Department of Mechanical Engineering, Michigan State University, Lansing (G.J.B.), Mich

    1 shared publication
  • Ali Spanta

    1 shared publication

Latest Publications

  • Open Access

    Reperfusion Microvascular Ischemia After Prolonged Coronary Occlusion: Implications And Treatment With Local Supersaturated Oxygen Delivery

    by James Richard Spears

    Following a prolonged coronary arterial occlusion, heterogeneously scattered, focal regions of low erythrocyte flow are commonly found throughout the reperfused myocardium. Experimental studies have also demonstrated the presence of widespread, focally patchy regions of microvascular ischemia during reperfusion (RMI). However, the potential contribution of RMI to tissue viability and function has received little attention in the absence of practical clinical methods for its detection. In this review, the anatomic/functional basis of RMI is summarized, along with the evidence for its presence in reperfused myocardium. Advances in microcirculation research related to obstructive responses of vascular endothelial cells and blood elements to the effects of hypoxia and low shear stress are discussed, and a potential cycle of intensification of RMI from such responses and progressive loss of functional capillary density is presented. In capillaries with impaired erythrocyte flow, compensatory increases in the delivery of oxygen, because of its low solubility in plasma, are effective only at high partial pressures. As discussed herein, attenuation of the cycle with oxygen at hyperbaric levels in plasma is, very likely, responsible for improved tissue level perfusion noted experimentally. Observed clinical benefits from intracoronary SuperSaturated oxygen (SSO2) delivery, including infarct size reduction, can be attributed to attenuation of RMI with improvement in microvascular blood flow.


  • Acute Myocardial Infarction With Hyperoxemic Therapy (AMIHOT)

    by William W. O’nEill, Jack L. Martin, Simon R. Dixon, Antonio L. Bartorelli, Daniela Trabattoni, Pranobe V. Oemrawsingh, Douwe E. Atsma, Michael Chang, William Marquardt, Jae K. Oh, et al.


  • Aqueous Oxygen Attenuation of Reperfusion Microvascular Ischemia in a Canine Model of Myocardial Infarction

    by J. Richard Spears, Petar Prcevski, Rui Xu, Li Li, Giles Brereton, Marcello DiCarli, Ali Spanta, Richard Crilly, Steven Lavine, Richard Vander Heide

    Uncorrected microvascular ischemia may contribute to left ventricular impairment during reperfusion after prolonged coronary artery occlusion. Attenuation of such ischemia in microvessels with impaired erythrocyte flow may require delivery of oxygen at high levels in plasma. Intraarterial infusion of aqueous oxygen (AO) can be used in a site specific manner to achieve hyperoxemic levels of oxygenation in the perfusate. With this new approach, the hypothesis was tested that reperfusion microvascular ischemia can be attenuated. After a 90 min coronary balloon occlusion in a canine model, AO hyperoxemic intracoronary perfusion was performed for 90 min after a 30 min period of autoreperfusion. Control groups consisted of normoxemic reperfusion, both passive (autoreperfusion) and active (roller pump). A significant improvement in left ventricular ejection fraction (p < 0.05) at 2 hr of reperfusion was noted only in the AO hyperoxemia group (17 ± 6% by two dimensional echo), without a significant reduction in the improvement 1 hr after termination of treatment. During AO hyperoxemic perfusion, ECG ST segment isoelectric deviation normalized, and frequency of ventricular premature contractions was significantly reduced, in contrast to the autoreperfusion control group (p < 0.05). Microvascular blood flow, measured as the ischemic/normal left ventricular segment ratio by radiolabeled microspheres immediately after AO hyperoxemic perfusion, was double the value of the autoreperfusion control group at 2 hr of reperfusion (p < 0.05). We conclude that reperfusion microvascular ischemia is attenuated by intracoronary AO hyperoxemic perfusion and acutely improves left ventricular function in this model.


  • Nucleation in small capillary tubes

    by G.J Brereton, R.J Crilly, J.R Spears


  • Aqueous Oxygen

    by J. Richard Spears, Bing Wang, Xiaojun Wu, Petar Prcevski, Alice J. Jiang, Ali D. Spanta, Richard J. Crilly, Giles J. Brereton

    BackgroundHigh levels of hyperoxemia may have utility in the treatment of regional tissue ischemia, but current methods for its implementation are impractical. A catheter-based method for infusion of O2, dissolved in a crystalloid solution at extremely high concentrations, ie, 1 to 3 mL O2/g (aqueous oxygen [AO]), into blood without bubble nucleation was recently developed for the potential hyperoxemic treatment of regional tissue ischemia.Methods and ResultsTo test the hypotheses that hypoxemia is correctable and that hyperoxemia can be produced locally by AO infusion, normal saline equilibrated with O2at 3 MPa (30 bar; 1 mL O2/g) was delivered into arterial blood in two different animal models. In 15 New Zealand White rabbits with systemic hypoxemia, AO was infused into the midabdominal aorta at 1 g/min. Mean distal arterial Po2increased to 236±113 and 593±114 mm Hg on 1-hour periods of air and O2breathing, respectively, from a baseline of 70±10 mm Hg (P<.01). In contrast, infusion of ordinary normal saline in a control group (n=7) had no effect on arterial Po2. No differences between groups (P>.05) in temporal changes in blood counts and chemistries were identified. In 10 dogs, low coronary blood flow in the circumflex artery was delivered with a roller pump through the central channel of an occluding balloon catheter. Hypoxemic, normoxemic, and AO-induced hyperoxemic blood perfusates (mean Po2, 52±4, 111±22, and 504±72 mm Hg, respectively) were infused for 3-minute periods in a randomized sequence. Short-axis two-dimensional echocardiography demonstrated a significant decrease (P<.05) in left ventricular ejection fraction compared with baseline physiological values with low-flow hypoxemic and normoxemic perfusion but not with low-flow hyperoxemic perfusion.ConclusionsIntra-arterial AO infusion was effective in these models for regional correction of hypoxemia and production of hyperoxemia.


  • Quantitative angioscopy: A novel method of measurement of luminal dimensions during angioscopy with the use of a ?lightwire?

    by J. Richard Spears, Mahmood Ali, Syed J. Raza, Gayathri S. Iyer, Srihari Ravi, Richard J. Crilly, Barbara Fromm, Wai-Fung Cheong

    Purpose To determine the accuracy and reproducibility of luminal dimension measurements of a newly developed method of quantitative angioscopy. Methods A method was developed for quantitation of luminal dimensions during angioscopy, as variation in magnification with lens-object distance and ambiguity associated with identification of corresponding points about the circumference of a given discrete cross-section render subjective estimates unreliable. A transverse ring of fiberoptically transmitted light was emitted from a guidewire or its housing at a known distance from the distal end of an angioscope and discrete cross-sections of interest were observed as the ring of light was reflected from the luminal surface. Caliper measurement of the diameter of the light ring image (< 50 mW at 488/515 nm), obtained on angioscopic video recordings of cylindrical phantom vessels of known dimensions, was performed by three observers on five occasions. Results The mean absolute difference between measured and known luminal diameter (n = 405 observations) was 65 μm±35 μm and the mean coefficient of variation was 4.2%, and the mean difference between measured and known areas (n = 195 observations) was 0.4 mm2, with a mean coefficient of variation of 6.5%. Conclusion By use of this new lightwire method, luminal dimensions can now be measuredin vitro with a high degree of accuracy and reproducibility during angioscopy.