GGGülay Zorer Gedik

Gülay Zorer Gedik

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Gülay Zorer Gedik has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Yapıların cam alanlarının enerji etkin iyileştirilmesi ve FDM uygulamasının enerji performansına etkisinin değerlendirilmesi: İstanbul ve Diyarbakır örnekleri

    by Hasan Tunay Cengiz, Gülay Zorer Gedik, Ezgi Korkmaz

    Bina ve inşaat sektörü, dünyada toplam enerji tüketiminin %36’sından ve CO2 salımının %39’undan sorumludur. Bu salımların iklim değişikliğine doğrudan etkisi olduğu bilinmektedir. Sektörün enerji tüketimi ve sera gazı salımını azaltmak için yapı stokunun iyileştirilmesi gerekmektedir. Bu iyileştirme için uygulanabilecek yöntemlerden birisi, enerji etkin iyileştirmeler ile mevcut binaların yapı kabuğu özelliklerini güçlendirmektir. Öte yandan, iklim değişikliği etkisiyle Türkiye’de sıcaklıkların giderek artacağı, özellikle yaz dönemindeki artışların kış dönemindekilerden fazla olacağı bilinmektedir. Bu eğilimden ötürü mevcut binaların iyileştirilmesinde yaz dönemindeki soğutma yüklerinin düşürülmesinin önemi gün geçtikçe artmaktadır. Bu çalışmada, Türkiye'de Toplu Konut İdaresi Başkanlığı'na ait bir tip proje, ılıman-nemli iklime sahip İstanbul ve sıcak-kuru iklime sahip Diyarbakır şehirleri için çeşitli enerji iyileştirmeleriyle DesignBuilder bina enerji simülasyonu yazılımı kullanılarak modellemiştir. Araştırma, iyileştirmelerin enerji verimliliği üzerindeki etkisini incelemiş, bu iyileştirmelerin maliyet analizi yapılmıştır. Seçilen iyileştirmeler, güneş kırıcı sistemlerin eklenmesi, cam sisteminin solar low-e sistemle değiştirilmesi ve yapının ısıl ataletini artırmak için faz değiştiren malzeme kullanımı ile sınırlıdır. Bu iyileştirmeler sonucunda, her iki şehirde de yaz dönemi soğutma yüklerinde azalma gözlemlenmiştir. Sonuçlar tekil olarak cam değişikliğinin hem soğutma yüklerini azaltmada hem de maliyet açısından en etkili yol olduğunu göstermektedir. Birleştirilmiş iyileştirme senaryolarının soğutma yükünü düşürmede çok etkin olduğu görülse de maliyet açısından etkinliği oldukça düşüktür.


  • Güçlendirme yapılan binalarda görsel konfor değişiminin saptanması ve iyileştirilmesi için bir yöntem: eğitim binası-derslik örneği

    by Ahmet Bircan Atmaca, Fatma Zoroğlu Çağlar, Rengin Ünver, Gülay Zorer Gedi̇k

    Işık, ses, ısı vb. fizik ortam öğelerine yönelik konfor koşullarının, hacimlerin işlevi ve kullanıcı özellikleri bağlamında, gereği gibi düzenlenmesinin kullanıcı performansı, sağlığı ve mekândaki enerji tüketiminin azaltılması gibi konularda olumlu katkı sağladığı bilinen bir gerçektir. Söz konusu düzenlemeler, gerek yeni yapılacak yapıların tasarımı gerekse mevcut yapıların yenileme çalışmaları sırasında gerçekleştirilmelidir. Mevcut yapılardaki yenileme işlemlerinden biri de, depremde hasar gören taşıyıcı sisteminin güçlendirilerek, binanın tekrar hizmete kazandırılmasıdır. Çalışmanın amacı, depremde hasar gören ve taşıyıcı sistemi güçlendirilerek yenilenen yapılarda, görsel konfor değişiminin saptanması ve iyileştirilmesi için bir yöntem önerisi oluşturulması ve bu yöntem doğrultusunda taşıyıcı sistemi güçlendirilen bir binanın kimi mekânlarındaki görsel konfor koşullarındaki değişimin belirlenmesi, iyileştirme önerilerinin yapılması olarak özetlenebilir. Belirtilen hedef doğrultusunda, önce öneri yönteme uygun olarak mevcut bir eğitim binasının tipik olduğu varsayılan dersliklerindeki, yapının güçlendirme öncesi ve sonrasındaki aydınlatma koşulları (doğal, yapay, bütünleşik) incelenmiş ve ilgili standartlar bağlamında değerlendirilmiş ardından kimi iyileştirme tasarımları yapılmıştır. Değerlendirme bulguları, incelenen yapıda güçlendirme öncesi aydınlatma koşulları daha olumlu olmasına karşın, her iki durumda da standartlardaki ölçütleri sağlama açısından, genelde yeterli olmadığını ortaya koymuş olup, gerekli koşulları sağlayacak yeni tasarımlar yapılmıştır. Böylece, çalışmada önerilen yöntem ve derslikler özelinde kullanılan inceleme yöntemleri ve öneriler, güçlendirme yapılan binalardaki mekânlarda görsel konfor için uygun koşullarının oluşmasına, enerji etkinliğinin sağlanmasına katkıda bulunacaktır.


  • An approach to the design of photovoltaic noise barriers and a case study from Istanbul, Turkey

    by Ferhan Hasmaden, Gülay Zorer Gedik, Neşe Yüğrük Akdağ

    Solar energy solutions that do not require additional space are critical. Noise barriers, which are built in low-value lands next to noise sources, provide effective areas for PV modules. There are many studies on using noise barriers as a sub-structure for photovoltaic systems, providing electricity generation besides noise reduction targets. Photovoltaic noise barrier (PVNB) technology combines noise control measures with renewable energy generation. In this study, it is aimed to develop an integrated design method that embeds solar energy technology in noise protection structures. The method is exemplified in an existing settlement located on the side of the road with heavy traffic. According to local climate and solar data, optimum tilt angles have been determined for annual, semi-annual, seasonal, and monthly periods. Noise barrier alternatives are derived with combinations of different diffraction edge sizes of barrier top and determined optimum inclination angles. The performance of the criteria that affect the PVNB effectiveness for alternatives was calculated through software tools. The energy generation potential of PVNB and its shading in adjacent blocks were calculated with PVsyst 6.7.7. The noise control efficiency of the structure was computed via SoundPLAN 7.2. TOPSIS method, one of the most common multi-criteria decision-making (MCDM) techniques, was used in the evaluation. As a result of TOPSIS, the best PVNB solution in the case study is the alternative that has 3-m and 2-m-wide edges and 58° and 31° tilted edges. In comparison with the current situation, the selected alternative will decrease 44% of the number of receiving points affected by noise and provide 524,804 kWh annual electricity generation.


  • Open Access

    Determination of Optimum Envelope of Religious Buildings in Terms of Thermal Comfort and Energy Consumption: Mosque Cases

    by Ahmet Bircan Atmaca, Gülay Zorer Gedik, Andreas Wagner

    Mosques are quite different from other building types in terms of occupant type and usage schedule. For this reason, they should be evaluated differently from other building types in terms of thermal comfort and energy consumption. It is difficult and probably not even necessary to create homogeneous thermal comfort in mosques’ entire usage area, which has large volumes and various areas for different activities. Nevertheless, energy consumption should be at a minimum level. In order to ensure that mosques are minimally affected by outdoor climatic changes, the improvement of the properties of the building envelope should have the highest priority. These optimal properties of the building envelope have to be in line with thermal comfort in mosques. The proposed method will be a guide for designers and occupants in the design process of new mosques or the use of existing mosques. The effect of the thermal properties of the building envelope on energy consumption was investigated to ensure optimum energy consumption together with an acceptable thermal comfort level. For this purpose, a parametric simulation study of the mosques was conducted by varying optical and thermal properties of the building envelope for a temperature humid climate zone. The simulation results were analyzed and evaluated according to current standards, and an appropriate envelope was determined. The results show that thermal insulation improvements in the roof dome of buildings with a large volume contributed more to energy savings than in walls and foundations. The use of double or triple glazing in transparent areas is an issue that should be considered together with the solar energy gain factor. Additionally, an increasing thickness of thermal insulation in the building envelope contributed positively to energy savings. However, the energy savings rate decreased after a certain thickness. The proposed building envelope achieved a 33% energy savings compared to the base scenario.


  • Open Access

    Relation of Urban Transformation Projects with Locality and Their Effects on Energy Conservation: The Case of Diyarbakır

    by Ceyda Duruş, Gülay Zorer Gedik

    Urban transformation projects which started for the urbanization of newly constructed cities in the history of Turkey are generally appears to build new housing projects for last years. Large amount of housing need caused by rapid increase in urban population has changed the face of the cities with these new constructions. These changes in the cities have increased the need for energy and pointed out the efficient and correct use of energy resources. Local resources are the simplest, accessible and efficient references of passive energy systems for energy conservation and play a major role in revealing the distinctive characteristics of cities. To show how the local features of a city contributes to decrease the energy consumption amount increased by urban transformation projects, two sample projects designed for the same climatic region were analyzed. First of these projects in the selected city Diyarbakır was designed by the traditional architecture principles and the second project was designed without references from the city’s local sources. Traditional design principles used in the first project were applied to the second project to improve the annual cooling and heating energy demand and show how these principles change results. The principles were assessed with comparative energy analyses.

  • Open Access

    EVALUATION OF MASS HOUSING SETTLEMENTS IN TERMS OF WIND AND NOISE CONTROL: ISTANBUL AND DIYARBAKIR AS A CASE

    by Gülay Zorer Gedi̇k, Neşe YÜĞRÜK AKDAĞ, Fatih Ki̇raz, Bekir Şener, Raşide ÇAÇAN

    In mass housing apartments, the comfort and quality of living conditions may be adversely affected by wind and noise especially on balconies, terraces, gardens and around swimming pools etc. The quantitative and empirical testing of building models according to physical conditions with regard to wind and noise parameters directly affects the formation of buildings in the design process. In this paper, two cities (Istanbul and Diyabakır), which are selected from two different climatic zones in Turkey are considered as examples to create maximum comfortable usage areas depending on wind and noise effects. For mass housing settlement scenarios, common comfortable areas in terms of wind and noise were determined by using Urbawind and soundPLAN softwares. The relevant data and acceptance criteria related to wind and noise and applied procedure are presented in the work. Performed studies show, if the settlements have dominant wind and noise directions, it is possible to find solutions using the geometric properties of the settlement in terms of wind and noise. In general, better comfort results appear in alternatives with L-C-U shaped design features rather than point-type and linear block layouts.