Vander Teixeira Prado
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Vander Teixeira Prado has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Óscar Martínez-Graullera
Instituto de Tecnologías Físicas y de la Información (ITEFI-CSIC), c/Serrano 144, 28006 Madrid, Spain
9 shared publications - Cláudio Kitano
Electrical Engineering Department, School of Engineering, São Paulo State University (UNESP), Ilha Solteira 15385-007, SP, Brazil
7 shared publications - Ricardo Tokio Higuti
São Paulo State University (UNESP), School of Engineering, Department of Electrical Engineering, SP, Brazil
6 shared publications Ricardo Tokio Higuti
Department of Electrical Engineering, Universidade Estadual Paulista - UNESP, Ilha Solteira - SP, Brazil
4 shared publicationsClaudio Kitano
Universidade Estadual Paulista, 15385-000 Ilha Solteira, SP, Brazil
2 shared publications- Julio Cesar Eduardo de Souza
Faculdade de Engenharia, Universidade Estadual Paulista (UNESP), Campus Ilha Solteira, Avenida Brasil, 56, Ilha Solteira 15385-000, SP, Brazil
2 shared publications
Latest Publications
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A New Fitness Function for Sparse Linear Array Evaluation Based on the Point Spread Function
This work proposes a new fitness function for sparse linear array design using the Point Spread Function (PSF), where the energy and entropy are combined. The Arithmetic optimization Algorithm is used as a search mechanism, and a new strategy to find sparse linear configurations is proposed. This new strategy eliminates the necessity of penalization functions to control the number of elements in sparse arrays. The algorithm is used to find two sparse linear arrays, one using a fitness function based on the radiation pattern, and the other with the proposed fitness function. Comparing the results, the configuration found using the proposed fitness function presented better lateral resolution and contrast.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
A New Fitness Function for Sparse Linear Array Evaluation Based on the Point Spread Function
This work proposes a new fitness function for sparse linear array design using the Point Spread Function (PSF), where the energy and entropy are combined. The Arithmetic optimization Algorithm is used as a search mechanism, and a new strategy to find sparse linear configurations is proposed. This new strategy eliminates the necessity of penalization functions to control the number of elements in sparse arrays. The algorithm is used to find two sparse linear arrays, one using a fitness function based on the radiation pattern, and the other with the proposed fitness function. Comparing the results, the configuration found using the proposed fitness function presented better lateral resolution and contrast.
- 13 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (5) , 1729-1741
Instantaneous Frequency Image
The instantaneous frequency (IF) image is proposed in this work. It is obtained by the differentiation of the instantaneous phase (IP) image, which in turn is calculated by replacing the amplitude information with the IP in the delay-and-sum beamforming. The IP image is a coherence factor that reduces artifacts and sidelobes influence, and it will be shown that the IF image will keep these same positive characteristics. In amplitude images the reflector representation level varies according to the experimental conditions, even using time-gain compensation. In IP images, the reflector is represented by a - π to π rad variation. An important feature of the IF image is that a reflector is represented by a constant level that is determined by the central frequency of the signal. Farther reflectors are represented with similar magnitudes as closer ones, being less influenced by distance than IP images and resulting in better contrast. Amplitude, IP, and IF images are obtained from point spread function simulations and a medical phantom in different experimental cases: vertical distances, contrast reflectors, axial and lateral separation, and a sparse array. The improper choice of dynamic range can result in low contrast or nondetection of a reflector. For the IF image, the dynamic range is determined by the central frequency of the signal and the zero-mean Gaussian distribution of the IF of noise. The IF image can be used to improve reflector detection, as additional information to assist the interpretation of pixels intensities in conventional amplitude images, or as a new coherence factor.
- 13 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (5) , 1729-1741
Instantaneous Frequency Image
The instantaneous frequency (IF) image is proposed in this work. It is obtained by the differentiation of the instantaneous phase (IP) image, which in turn is calculated by replacing the amplitude information with the IP in the delay-and-sum beamforming. The IP image is a coherence factor that reduces artifacts and sidelobes influence, and it will be shown that the IF image will keep these same positive characteristics. In amplitude images the reflector representation level varies according to the experimental conditions, even using time-gain compensation. In IP images, the reflector is represented by a - π to π rad variation. An important feature of the IF image is that a reflector is represented by a constant level that is determined by the central frequency of the signal. Farther reflectors are represented with similar magnitudes as closer ones, being less influenced by distance than IP images and resulting in better contrast. Amplitude, IP, and IF images are obtained from point spread function simulations and a medical phantom in different experimental cases: vertical distances, contrast reflectors, axial and lateral separation, and a sparse array. The improper choice of dynamic range can result in low contrast or nondetection of a reflector. For the IF image, the dynamic range is determined by the central frequency of the signal and the zero-mean Gaussian distribution of the IF of noise. The IF image can be used to improve reflector detection, as additional information to assist the interpretation of pixels intensities in conventional amplitude images, or as a new coherence factor.
- Open Access
- 22 December 2020
- Published by Journal of Integrated Circuits and Systems in Journal of Integrated Circuits and Systems
- Vol. 15 (3) , 1-5
Improving Ultrasonic Imaging of Aluminum Plates using Phase Modulation
Ultrasonic imaging using arrays is a widespread technique used in medical imaging, with increasing use in industry. Conventional techniques use amplitude information from the ultrasonic signals to produce the images. These amplitude images can be produced with high quality, but can also present limitations regarding dead zone, artifacts and detection of far reflectors. Coherence images based on the signal phase have been explored in some works, and produce an image that indicates the presence of a defect. In this work we explore he effect of phase modulation of the ultrasonic signal and its effect on the corresponding coherence image. Simulations and experimental tests in an aluminum plate using Lamb waves and a linear piezoelectric array show that the phase modulation hasadvantages over coherence images without phase modulation for defect indication.
- 22 December 2020
- Published by Journal of Integrated Circuits and Systems in Journal of Integrated Circuits and Systems
- Vol. 15 (3) , 1-5
Open AccessImproving Ultrasonic Imaging of Aluminum Plates using Phase Modulation
Ultrasonic imaging using arrays is a widespread technique used in medical imaging, with increasing use in industry. Conventional techniques use amplitude information from the ultrasonic signals to produce the images. These amplitude images can be produced with high quality, but can also present limitations regarding dead zone, artifacts and detection of far reflectors. Coherence images based on the signal phase have been explored in some works, and produce an image that indicates the presence of a defect. In this work we explore he effect of phase modulation of the ultrasonic signal and its effect on the corresponding coherence image. Simulations and experimental tests in an aluminum plate using Lamb waves and a linear piezoelectric array show that the phase modulation hasadvantages over coherence images without phase modulation for defect indication.
- 16 May 2019
- Published by Springer Nature
- p. 441-445
Sparse Array Design Using the Genetic Algorithm for Optimizing the Radiation Pattern of Linear Arrays
- 16 May 2019
- Published by Springer Nature
- p. 441-445
Sparse Array Design Using the Genetic Algorithm for Optimizing the Radiation Pattern of Linear Arrays
- 1 November 2017
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 96, 321-332
Ultrasound imaging of immersed plates using high-order Lamb modes at their low attenuation frequency bands
- 1 November 2017
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 96, 321-332
Ultrasound imaging of immersed plates using high-order Lamb modes at their low attenuation frequency bands
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Ultrasonic image compounding method based on the instantaneous phase image
The quality of ultrasonic images depends on array configuration, image beamforming algorithm, propagation modes and signal-to-noise ratio. Some alternatives to improve image quality are related to the use of coherence weighting factors and image compounding techniques. This work proposes an image compounding method based on the Instantaneous Phase (IP) image. From the analysis of this image and the application of the respective threshold, a coherence weighting factor is created, which is multiplied by the conventional amplitude images to reduce artifacts and improve contrast. The images are then combined according to the indication of the presence of reflectors in the IP image. The method was experimentally tested on an aluminum plate with artificial defects. As result artifacts and dead zone are reduced, and contrast and defects detection are improved.
- 1 November 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
Ultrasonic image compounding method based on the instantaneous phase image
The quality of ultrasonic images depends on array configuration, image beamforming algorithm, propagation modes and signal-to-noise ratio. Some alternatives to improve image quality are related to the use of coherence weighting factors and image compounding techniques. This work proposes an image compounding method based on the Instantaneous Phase (IP) image. From the analysis of this image and the application of the respective threshold, a coherence weighting factor is created, which is multiplied by the conventional amplitude images to reduce artifacts and improve contrast. The images are then combined according to the indication of the presence of reflectors in the IP image. The method was experimentally tested on an aluminum plate with artificial defects. As result artifacts and dead zone are reduced, and contrast and defects detection are improved.
- 15 October 2015
- Published by Taylor & Francis
- p. 567-594
Synthetic Aperture Imaging for Ultrasonic Non-Destructive Testing
- 15 October 2015
- Published by Taylor & Francis
- p. 567-594
Synthetic Aperture Imaging for Ultrasonic Non-Destructive Testing
- 13 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 62 (10) , 1888-1894
Defect detection in anisotropic plates based on the instantaneous phase of signals
Anisotropic materials are widely employed in industry and engineering, and efficient nondestructive testing techniques are important to guarantee the structural integrity of the involved parts. A simple technique is proposed to detect defects in anisotropic plates using ultrasonic guided waves and arrays. The technique is based on the application of an objective threshold to a synthetic aperture image obtained from the instantaneous phase (IP) of the emitter-receiver signal combinations. In a previous work the method was evaluated for isotropic materials, and in this paper it is shown that with some considerations the technique can also be applied to anisotropic plates. These considerations, which should be taken into account in beamforming, are (1) group velocity dependence with propagation direction, and (2) elastic focusing, which results in energy concentration in some propagation directions, with the practical consequence that not all aperture signals effectively contribute to the image. When compared with conventional delay-and-sum image beamforming techniques, the proposed IP technique results in significant improvements relative to defect detection and artifacts/dead zone reduction.
- 13 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 62 (10) , 1888-1894
Defect detection in anisotropic plates based on the instantaneous phase of signals
Anisotropic materials are widely employed in industry and engineering, and efficient nondestructive testing techniques are important to guarantee the structural integrity of the involved parts. A simple technique is proposed to detect defects in anisotropic plates using ultrasonic guided waves and arrays. The technique is based on the application of an objective threshold to a synthetic aperture image obtained from the instantaneous phase (IP) of the emitter-receiver signal combinations. In a previous work the method was evaluated for isotropic materials, and in this paper it is shown that with some considerations the technique can also be applied to anisotropic plates. These considerations, which should be taken into account in beamforming, are (1) group velocity dependence with propagation direction, and (2) elastic focusing, which results in energy concentration in some propagation directions, with the practical consequence that not all aperture signals effectively contribute to the image. When compared with conventional delay-and-sum image beamforming techniques, the proposed IP technique results in significant improvements relative to defect detection and artifacts/dead zone reduction.
- 23 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 61 (7) , 1204-1215
Instantaneous phase threshold for reflector detection in ultrasonic images
A method for reflector detection, based on the instantaneous phase of the aperture data for ultrasonic images, is proposed. The instantaneous phase (IP) image is obtained by replacing the amplitude information by the instantaneous phase in the delay-and-sum (DAS) beamforming. From the analysis of the IP image, a threshold level is defined in terms of the number of signals used for imaging. This threshold is applied to the IP image, resulting in a two-level image which gives a statistical indication of whether the pixels of a region in the image are related to a reflector or noise/artifacts. Because the proposed method uses only the instantaneous phase of the signals, it is less sensitive to attenuation than conventional DAS amplitude images. The point spread function of a 32-element array with half-wavelength pitch at 5 MHz in water is simulated and the reflector is detected for signal-to-noise ratio values larger than -29.6 dB. A phantom and an aluminum plate with artificial defects are tested with the proposed technique, using linear arrays of 64 and 16 elements, respectively. When compared with DAS amplitude images and with two-level images obtained by thresholding the amplitude images using empirical threshold values, the proposed technique reduced artifacts and dead zone, and detected all reflectors, increasing reflectors' detectability and decreasing the occurrence of false indication of reflectors. The proposed technique can be used as additional information for amplitude image analysis, with the advantages that it does not need time-gain compensation and that it considers an objective threshold value.
- 23 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 61 (7) , 1204-1215
Instantaneous phase threshold for reflector detection in ultrasonic images
A method for reflector detection, based on the instantaneous phase of the aperture data for ultrasonic images, is proposed. The instantaneous phase (IP) image is obtained by replacing the amplitude information by the instantaneous phase in the delay-and-sum (DAS) beamforming. From the analysis of the IP image, a threshold level is defined in terms of the number of signals used for imaging. This threshold is applied to the IP image, resulting in a two-level image which gives a statistical indication of whether the pixels of a region in the image are related to a reflector or noise/artifacts. Because the proposed method uses only the instantaneous phase of the signals, it is less sensitive to attenuation than conventional DAS amplitude images. The point spread function of a 32-element array with half-wavelength pitch at 5 MHz in water is simulated and the reflector is detected for signal-to-noise ratio values larger than -29.6 dB. A phantom and an aluminum plate with artificial defects are tested with the proposed technique, using linear arrays of 64 and 16 elements, respectively. When compared with DAS amplitude images and with two-level images obtained by thresholding the amplitude images using empirical threshold values, the proposed technique reduced artifacts and dead zone, and detected all reflectors, increasing reflectors' detectability and decreasing the occurrence of false indication of reflectors. The proposed technique can be used as additional information for amplitude image analysis, with the advantages that it does not need time-gain compensation and that it considers an objective threshold value.
- 1 October 2013
- Published by Elsevier in NDT & E International
- Vol. 59, 86-95
Lamb mode diversity imaging for non-destructive testing of plate-like structures
- 1 October 2013
- Published by Elsevier in NDT & E International
- Vol. 59, 86-95
Lamb mode diversity imaging for non-destructive testing of plate-like structures