Jesus Moreno-Fernandez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jesus Moreno-Fernandez has a total of 149 co-authors. Here are the top co-authors by number of shared publications:
- Ana Chico
Endocrinology and Nutrition Department, Hospital Santa Creu i Sant Pau Barcelona, Barcelona, Spain
6 shared publications - Pilar Isabel Beato-Víbora
Badajoz University Hospital, Extremadura University
6 shared publications - José Ramón Muñoz-Rodríguez
Translational Research Unit, University General Hospital and Research Institute of Castilla-La Mancha (IDISCAM), 13004 Ciudad Real, Spain
5 shared publications - Marcos Pazos-Couselo
Faculty of Nursing University of Santiago de Compostela Santiago de Compostela Spain
5 shared publications Pedro Pinés
Department of Endocrinology and Nutrition, Albacete University Hospital, Albacete, Spain
5 shared publications- Carmen Gutiérrez-Alcántara
Servicio de Endocrinología y Nutrición, Complejo Hospitalario de Jaén, Jaén, España
4 shared publications
Latest Publications
- 27 May 2026
- Published by Elsevier in Medicina Clinica
- Vol. 166 (7) , 107450
Continuous glucose monitoring to support the diagnosis of MODY: A multicenter cross-sectional and prospective study
- 27 May 2026
- Published by Elsevier in Medicina Clinica
- Vol. 166 (7) , 107450
Continuous glucose monitoring to support the diagnosis of MODY: A multicenter cross-sectional and prospective study
- Open Access
- 13 April 2026
- Published by Wiley in Worldviews on Evidence-Based Nursing
- Vol. 23 (2) , e70139
A Nurse‐Led Educational Intervention for Patients With Type 1 Diabetes Using Continuous Glucose Monitoring
Background: The primary barrier to maximizing the benefits of intermittently scanned continuous glucose monitoring (isCGM) is low scan frequency. Higher daily scan frequency correlates with better glycemic control. Aim: To evaluate the effect of a nurse‐led educational intervention on scan frequency and behavioral change in adults with type 1 diabetes (T1D) showing low scanning frequency. Methods: In this 12‐week quasi‐experimental study, adults with T1D using isCGM and low scan frequency participated in a single, individualized, direct education session led by a diabetes nurse educator. The intervention focused on increasing daily scan frequency and supporting patient engagement in self‐management. Results: Thirty‐four patients using isCGM participated. Mean daily scan frequency increased from 3.1 to 6.1 scans/day following the intervention. This rise was associated with an 8.0% improvement in TIR. A positive correlation was observed between scan frequency and TIR, with each additional daily scan associated with a 0.51% increase in TIR. Linking Evidence to Action: A single, targeted educational session can significantly improve isCGM adherence and glycemic control in adults with T1D and low adherence, supporting its value as a practical strategy in routine clinical care. Trial Registration: The protocol was publicly registered at ClinicalTrials.gov (NCT05570162)
- 13 April 2026
- Published by Wiley in Worldviews on Evidence-Based Nursing
- Vol. 23 (2) , e70139
Open AccessA Nurse‐Led Educational Intervention for Patients With Type 1 Diabetes Using Continuous Glucose Monitoring
Background: The primary barrier to maximizing the benefits of intermittently scanned continuous glucose monitoring (isCGM) is low scan frequency. Higher daily scan frequency correlates with better glycemic control. Aim: To evaluate the effect of a nurse‐led educational intervention on scan frequency and behavioral change in adults with type 1 diabetes (T1D) showing low scanning frequency. Methods: In this 12‐week quasi‐experimental study, adults with T1D using isCGM and low scan frequency participated in a single, individualized, direct education session led by a diabetes nurse educator. The intervention focused on increasing daily scan frequency and supporting patient engagement in self‐management. Results: Thirty‐four patients using isCGM participated. Mean daily scan frequency increased from 3.1 to 6.1 scans/day following the intervention. This rise was associated with an 8.0% improvement in TIR. A positive correlation was observed between scan frequency and TIR, with each additional daily scan associated with a 0.51% increase in TIR. Linking Evidence to Action: A single, targeted educational session can significantly improve isCGM adherence and glycemic control in adults with T1D and low adherence, supporting its value as a practical strategy in routine clinical care. Trial Registration: The protocol was publicly registered at ClinicalTrials.gov (NCT05570162)
- 3 April 2026
- Published by Elsevier in Diabetes & Metabolism
- Vol. 52 (3) , 101757
Clinical effectiveness of different advanced hybrid closed-loop systems on time in tight range in adults with type 1 diabetes: A multicenter real-world study
- 3 April 2026
- Published by Elsevier in Diabetes & Metabolism
- Vol. 52 (3) , 101757
Clinical effectiveness of different advanced hybrid closed-loop systems on time in tight range in adults with type 1 diabetes: A multicenter real-world study
- Open Access
- 6 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-8
Impact of heatwaves on glycemic control in adults with type 1 diabetes using hybrid closed-loop systems
To evaluate the effect of the August´s 2023 heatwaves over glycemic control in adults with type 1 diabetes (T1D) treated with advance hybrid closed-loop systems (AHCL). Cross-sectional retrospective analysis of adult patients with T1D in Castilla-La Mancha (south-central Spanish region) using AHCL during the August´s 2023 heatwaves period. Primary outcome was change in time in range (TIR) 3.0–10 mmol/L (70–180 mg/dL) of interstitial glucose after the end of the heatwaves period. A total of 193 T1D patients were analyzed. TIR remained constant after the end of the heatwaves period (0.5% [95% CI -0.3, 1.3; P = 0.236]). No differences were observed among the rest of glycometric index. The percentage of patients meeting all the recommendations of the International Consensus of Time in Range was similar during the heatwaves period than after it ended (44.6% vs. 45.6%, P = 1.000). Finally, the percentage of time in automatization and daily insulin dose also stayed stable (0.5% [95% CI -1.4, 2.4; P = 0.601] and 0.0 UI/day [95% CI -1.0, 1.0; P = 0.981], respectively). Adults with T1D treated with AHCL maintained glycemic control during August´s 2023 heatwaves. These data raise the possibility that AHCL systems could help protect T1D patients from the effects of heatwaves on glycemic control.
- 6 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 1-8
Open AccessImpact of heatwaves on glycemic control in adults with type 1 diabetes using hybrid closed-loop systems
To evaluate the effect of the August´s 2023 heatwaves over glycemic control in adults with type 1 diabetes (T1D) treated with advance hybrid closed-loop systems (AHCL). Cross-sectional retrospective analysis of adult patients with T1D in Castilla-La Mancha (south-central Spanish region) using AHCL during the August´s 2023 heatwaves period. Primary outcome was change in time in range (TIR) 3.0–10 mmol/L (70–180 mg/dL) of interstitial glucose after the end of the heatwaves period. A total of 193 T1D patients were analyzed. TIR remained constant after the end of the heatwaves period (0.5% [95% CI -0.3, 1.3; P = 0.236]). No differences were observed among the rest of glycometric index. The percentage of patients meeting all the recommendations of the International Consensus of Time in Range was similar during the heatwaves period than after it ended (44.6% vs. 45.6%, P = 1.000). Finally, the percentage of time in automatization and daily insulin dose also stayed stable (0.5% [95% CI -1.4, 2.4; P = 0.601] and 0.0 UI/day [95% CI -1.0, 1.0; P = 0.981], respectively). Adults with T1D treated with AHCL maintained glycemic control during August´s 2023 heatwaves. These data raise the possibility that AHCL systems could help protect T1D patients from the effects of heatwaves on glycemic control.
- Open Access
- 6 August 2025
- Published by Elsevier in Endocrine Practice
- Vol. 31 (12) , 1530-1537
Clinical and Economic Impact of Hybrid Closed-Loop Systems for T1 Diabetes Management in Spain
- 6 August 2025
- Published by Elsevier in Endocrine Practice
- Vol. 31 (12) , 1530-1537
Open AccessClinical and Economic Impact of Hybrid Closed-Loop Systems for T1 Diabetes Management in Spain
- 20 July 2025
- Published by Elsevier in Diabetes Research and Clinical Practice
- Vol. 226, 112377
Beyond glycemic metrics: Real-world benefits of connected insulin pens in type 1 diabetes
- 20 July 2025
- Published by Elsevier in Diabetes Research and Clinical Practice
- Vol. 226, 112377
Beyond glycemic metrics: Real-world benefits of connected insulin pens in type 1 diabetes
- 26 February 2025
- Published by Elsevier in Diabetes Research and Clinical Practice
- Vol. 222, 112070
Transitioning between automated insulin delivery systems: A focus on personalisation
- 26 February 2025
- Published by Elsevier in Diabetes Research and Clinical Practice
- Vol. 222, 112070
Transitioning between automated insulin delivery systems: A focus on personalisation
- Open Access
- 19 April 2024
- Published by American Diabetes Association in Diabetes Care
- Vol. 47 (5) , e46-e47
Response to Comment on Beato-Víbora et al. A Multicenter Prospective Evaluation of the Benefits of Two Advanced Hybrid Closed-Loop Systems in Glucose Control and Patient-Reported Outcomes in a Real-world Setting. Diabetes Care 2024;47:216–224
We would like to express our gratitude to Lebbar et al. (1) for their interest in our work (2) and for their valuable comments. We value this opportunity t We would like to express our gratitude to Lebbar et al. (1) for their interest in our work (2) and for their valuable comments. We value this opportunity t
- 19 April 2024
- Published by American Diabetes Association in Diabetes Care
- Vol. 47 (5) , e46-e47
Open AccessResponse to Comment on Beato-Víbora et al. A Multicenter Prospective Evaluation of the Benefits of Two Advanced Hybrid Closed-Loop Systems in Glucose Control and Patient-Reported Outcomes in a Real-world Setting. Diabetes Care 2024;47:216–224
We would like to express our gratitude to Lebbar et al. (1) for their interest in our work (2) and for their valuable comments. We value this opportunity t We would like to express our gratitude to Lebbar et al. (1) for their interest in our work (2) and for their valuable comments. We value this opportunity t
- 15 November 2023
- Published by Elsevier in Primary Care Diabetes
- Vol. 18 (1) , 59-64
All-cause mortality and risk factors in patients with type 1 diabetes in Castilla-La Mancha, Spain. DIACAM1 2010–2020 study
- 15 November 2023
- Published by Elsevier in Primary Care Diabetes
- Vol. 18 (1) , 59-64
All-cause mortality and risk factors in patients with type 1 diabetes in Castilla-La Mancha, Spain. DIACAM1 2010–2020 study
- 10 November 2023
- Published by American Diabetes Association in Diabetes Care
- Vol. 47 (2) , 216-224
A Multicenter Prospective Evaluation of the Benefits of Two Advanced Hybrid Closed-Loop Systems in Glucose Control and Patient-Reported Outcomes in a Real-world Setting
OBJECTIVE: Advanced hybrid closed-loop systems (AHCL) have been shown to improve glycemic control and patient-reported outcomes in type 1 diabetes. The aim was to analyze the outcomes of two commercially available AHCL in real life. RESEARCH DESIGN AND METHODS: A prospective study was performed, including adolescents and adults with type 1 diabetes, AHCL naïve, from 14 centers, who initiated the use of MM780G with SmartGuard or Tandem t:slimX2 with Control-IQ. Baseline and 3-month evaluations were performed, assessing HbA1c, time in different glycemic ranges, and patient-reported outcomes. The primary outcome was the between-group time in range 70–180 mg/dL difference from beginning to end of follow-up. RESULTS: One hundred fifty participants were included, with 75 initiating each system (age: 39.9 ± 11.4 years [16–72]; 64% female; diabetes duration: 21.6 ± 11.9 years). Time in range increased from 61.53 ± 14.01% to 76.17 ± 9.48% (P < 0.001), with no between-group differences (P = 0.591). HbA1c decreased by 0.56% (95% CI 0.44%, 0.68%) (6 mmol/mol, 95% CI 5, 7) (P < 0.001), from 7.43 ± 1.07% to 6.88 ± 0.60% (58 ± 12 to 52 ± 7 mmol/mol) in the MM780G group, and from 7.14 ± 0.70% to 6.56 ± 0.53% (55 ± 8 to 48 ± 6 mmol/mol) in the Control-IQ group (both P < 0.001 to baseline, P = 0.819 between groups). No superiority of one AHCL over the other regarding fear of hypoglycemia or quality of life was found. Improvement in diabetes-related distress was higher in Control-IQ users (P = 0.012). Sleep quality was improved (PSQI: from 6.94 ± 4.06 to 6.06 ± 4.05, P = 0.004), without differences between systems. Experience with AHCL, evaluated by the INSPIRE measures, exceeded the expectations. CONCLUSIONS: The two AHCL provide significant improvement in glucose control and satisfaction, with no superiority of one AHCL over the other.
- 10 November 2023
- Published by American Diabetes Association in Diabetes Care
- Vol. 47 (2) , 216-224
A Multicenter Prospective Evaluation of the Benefits of Two Advanced Hybrid Closed-Loop Systems in Glucose Control and Patient-Reported Outcomes in a Real-world Setting
OBJECTIVE: Advanced hybrid closed-loop systems (AHCL) have been shown to improve glycemic control and patient-reported outcomes in type 1 diabetes. The aim was to analyze the outcomes of two commercially available AHCL in real life. RESEARCH DESIGN AND METHODS: A prospective study was performed, including adolescents and adults with type 1 diabetes, AHCL naïve, from 14 centers, who initiated the use of MM780G with SmartGuard or Tandem t:slimX2 with Control-IQ. Baseline and 3-month evaluations were performed, assessing HbA1c, time in different glycemic ranges, and patient-reported outcomes. The primary outcome was the between-group time in range 70–180 mg/dL difference from beginning to end of follow-up. RESULTS: One hundred fifty participants were included, with 75 initiating each system (age: 39.9 ± 11.4 years [16–72]; 64% female; diabetes duration: 21.6 ± 11.9 years). Time in range increased from 61.53 ± 14.01% to 76.17 ± 9.48% (P < 0.001), with no between-group differences (P = 0.591). HbA1c decreased by 0.56% (95% CI 0.44%, 0.68%) (6 mmol/mol, 95% CI 5, 7) (P < 0.001), from 7.43 ± 1.07% to 6.88 ± 0.60% (58 ± 12 to 52 ± 7 mmol/mol) in the MM780G group, and from 7.14 ± 0.70% to 6.56 ± 0.53% (55 ± 8 to 48 ± 6 mmol/mol) in the Control-IQ group (both P < 0.001 to baseline, P = 0.819 between groups). No superiority of one AHCL over the other regarding fear of hypoglycemia or quality of life was found. Improvement in diabetes-related distress was higher in Control-IQ users (P = 0.012). Sleep quality was improved (PSQI: from 6.94 ± 4.06 to 6.06 ± 4.05, P = 0.004), without differences between systems. Experience with AHCL, evaluated by the INSPIRE measures, exceeded the expectations. CONCLUSIONS: The two AHCL provide significant improvement in glucose control and satisfaction, with no superiority of one AHCL over the other.