Qingshan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qingshan Li has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Yi Lv
Department of Hepatobiliary Surgery, the First Affiliated Hospital of Xi’an Jiaotong University, Xi’an, China
5 shared publications - Fenggang Ren
National Local Joint Engineering Research Center for Precision Surgery and Regenerative Medicine The First Affiliated Hospital of Xi'an Jiaotong University Xi'an Shaanxi China
2 shared publications Liangshuo Hu
National Local Joint Engineering Research Center for Precision Surgery & Regenerative Medicine Shaanxi Provincial Center for Regenerative Medicine and Surgical Engineering Institute of Advanced Surgical Technology and Engineering The First Affiliated Hospital of Xi’an Jiaotong University Xi’an China
2 shared publications- Rongqian Wu
National Local Joint Engineering Research Center for Precision Surgery and Regenerative Medicine, Shaanxi Provincial Center for Regenerative Medicine and Surgical Engineering, The First Affiliated Hospital of Xi’an Jiaotong University
2 shared publications Yuchi Zhang
National Local Joint Engineering Research Center for Precision Surgery and Regenerative Medicine, First Affiliated Hospital of Xi’an Jiaotong University
2 shared publications- Bo Wang
Department of Neurosurgery Tianjin University Huanhu Hospital Tianjin China
1 shared publication
Latest Publications
- Open Access
- 31 July 2022
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 39 (1) , 1017-1025
Numerical analysis and animal study of noninvasive handheld electroporation delivery device for skin superficial lesion treatment
This study aims to investigate the feasibility of a noninvasive handheld electroporation pulses delivery device (EPDD) for electroporation-based treatment (EBT) of skin superficial lesions through ...
- 31 July 2022
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 39 (1) , 1017-1025
Open AccessNumerical analysis and animal study of noninvasive handheld electroporation delivery device for skin superficial lesion treatment
This study aims to investigate the feasibility of a noninvasive handheld electroporation pulses delivery device (EPDD) for electroporation-based treatment (EBT) of skin superficial lesions through ...
- 22 July 2020
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 27 (10) , 776-784
Acute and subacute effects of irreversible electroporation on normal common bile ducts in a rabbit model
Background/Purpose: This study aimed to evaluate the acute and subacute effects of irreversible electroporation (IRE) on normal common bile ducts (CBDs).Methods: Cell susceptibility to IRE was assessed in vitro with cholangiocarcinoma and normal cell lines. The electric field and temperature distributions were evaluated with a two‐dimensional simulation model of bile duct. In vivo bile duct IRE was performed in 28 adult rabbits.Results: Different cells showed different susceptibility to the effect of IRE, cancer cell line HUCC‐T1 was the least sensitive to IRE. Simulations predicted the distributions of electric field and temperature during the IRE process, and the maximum temperature of tissue was below 43℃. Complications were observed in 8/28 animals (biliary dilatation, n = 4; biliary stricture, n = 4) by postoperative days 7, 14, and 28. Histopathological analyses revealed complete cell death with bile duct wall integrity. Bile duct epithelial recovery was completed between post‐IRE days 14‐28.Conclusions: The normal CBD retains the lumen wall integrity following IRE with immediate periductal placement of the electrode. However, the risk of biliary dilatation and stricture is a reminder that the parameters of IRE need to be determined more precisely to ensure the treatment efficacy and reduce the risk of collateral damage.
- 22 July 2020
- Published by Wiley in Journal of Hepato-Biliary-Pancreatic Sciences
- Vol. 27 (10) , 776-784
Acute and subacute effects of irreversible electroporation on normal common bile ducts in a rabbit model
Background/Purpose: This study aimed to evaluate the acute and subacute effects of irreversible electroporation (IRE) on normal common bile ducts (CBDs).Methods: Cell susceptibility to IRE was assessed in vitro with cholangiocarcinoma and normal cell lines. The electric field and temperature distributions were evaluated with a two‐dimensional simulation model of bile duct. In vivo bile duct IRE was performed in 28 adult rabbits.Results: Different cells showed different susceptibility to the effect of IRE, cancer cell line HUCC‐T1 was the least sensitive to IRE. Simulations predicted the distributions of electric field and temperature during the IRE process, and the maximum temperature of tissue was below 43℃. Complications were observed in 8/28 animals (biliary dilatation, n = 4; biliary stricture, n = 4) by postoperative days 7, 14, and 28. Histopathological analyses revealed complete cell death with bile duct wall integrity. Bile duct epithelial recovery was completed between post‐IRE days 14‐28.Conclusions: The normal CBD retains the lumen wall integrity following IRE with immediate periductal placement of the electrode. However, the risk of biliary dilatation and stricture is a reminder that the parameters of IRE need to be determined more precisely to ensure the treatment efficacy and reduce the risk of collateral damage.
- Open Access
Kaya: A Testing Framework for Blockchain-based Decentralized Applications
In recent years, many decentralized applications based on blockchain (DApp) have been developed. However, due to inadequate testing, DApps are easily exposed to serious vulnerabilities. We find three main challenges for DApp testing, i.e., the inherent complexity of DApp, inconvenient pre-state setting, and not-so-readable logs. In this paper, we propose a testing framework named Kaya to bridge these gaps. Kaya has three main functions. Firstly, Kaya proposes DApp behavior description language (DBDL) to make writing test cases easier. Test cases written in DBDL can also be automatically executed by Kaya. Secondly, Kaya supports a flexible and convenient way for test engineers to set the blockchain pre-states easily. Thirdly, Kaya transforms incomprehensible addresses into readable variables for easy comprehension. With these functions, Kaya can help test engineers test DApps more easily. Besides, to fit the various application environments, we provide two ways for test engineers to use Kaya, i.e., UI and command-line. Our experimental case demonstrates the potential of Kaya in helping test engineers to test DApps more easily.
Open AccessKaya: A Testing Framework for Blockchain-based Decentralized Applications
In recent years, many decentralized applications based on blockchain (DApp) have been developed. However, due to inadequate testing, DApps are easily exposed to serious vulnerabilities. We find three main challenges for DApp testing, i.e., the inherent complexity of DApp, inconvenient pre-state setting, and not-so-readable logs. In this paper, we propose a testing framework named Kaya to bridge these gaps. Kaya has three main functions. Firstly, Kaya proposes DApp behavior description language (DBDL) to make writing test cases easier. Test cases written in DBDL can also be automatically executed by Kaya. Secondly, Kaya supports a flexible and convenient way for test engineers to set the blockchain pre-states easily. Thirdly, Kaya transforms incomprehensible addresses into readable variables for easy comprehension. With these functions, Kaya can help test engineers test DApps more easily. Besides, to fit the various application environments, we provide two ways for test engineers to use Kaya, i.e., UI and command-line. Our experimental case demonstrates the potential of Kaya in helping test engineers to test DApps more easily.
- Open Access
- 1 January 2020
- Published by XMLink in Annals of Surgical Treatment and Research
- Vol. 99 (1) , 1-7
Operation start time and long-term outcome of hepatocellular carcinoma after curative hepatic resection
Lu Q, et al. Ann Surg Treat Res. 2020 Jul;99(1):1-7. https://doi.org/10.4174/astr.2020.99.1.1
- 1 January 2020
- Published by XMLink in Annals of Surgical Treatment and Research
- Vol. 99 (1) , 1-7
Open AccessOperation start time and long-term outcome of hepatocellular carcinoma after curative hepatic resection
Lu Q, et al. Ann Surg Treat Res. 2020 Jul;99(1):1-7. https://doi.org/10.4174/astr.2020.99.1.1
- Open Access
- 1 January 2019
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 36 (1) , 853-866
Electrical and thermal analyses of catheter-based irreversible electroporation of digestive tract
Introduction: Irreversible electroporation (IRE) combined with a catheter-based electrode during endoscopy is a potential alternative treatment method for digestive tract tumors. The aim of this study was to investigate the electrical injury (EI) and thermal injury (TI) to the digestive tract via numerical analyses and to evaluate the role and impact of electrode configurations and pulse settings on the efficacy and outcomes of IRE. Materials and methods: A finite element method was used to solve the numerical model. A digestive tract model having 4-mm-thick walls and two catheter-based electrode configuration models were constructed. The distributions of electric fields, temperature, electrical conductivity, tissue injury and limitation on the pulse number required for IRE were calculated and compared. Results: Electrode length is an important geometric parameter for electrodes in the monopolar model (MPM), while electrode spacing affects the outcomes in the bipolar model (BPM). Increasing the pulse voltage reduces the pulse number required for tissue ablation, while increasing the risk of TI. In total, there were 6 NT-IRE protocols, 12 thermal-IRE protocols and 30 TI protocols. All of the NT-IRE protocols were set in BPMs with a voltage of 0.50 kV. With increasing electrode spacing, the minimum pulse number decreased. However, thermal effects were inevitable in the MPM. Conclusions: The electrode configuration and pulse settings are adjusted to achieve NT-IRE synergistically. The BPM is more reliable for achieving NT-IRE in 4-mm-thick digestive wall. Future in vitro and in vivo studies are needed to support and validate this conclusion.
- 1 January 2019
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 36 (1) , 853-866
Open AccessElectrical and thermal analyses of catheter-based irreversible electroporation of digestive tract
Introduction: Irreversible electroporation (IRE) combined with a catheter-based electrode during endoscopy is a potential alternative treatment method for digestive tract tumors. The aim of this study was to investigate the electrical injury (EI) and thermal injury (TI) to the digestive tract via numerical analyses and to evaluate the role and impact of electrode configurations and pulse settings on the efficacy and outcomes of IRE. Materials and methods: A finite element method was used to solve the numerical model. A digestive tract model having 4-mm-thick walls and two catheter-based electrode configuration models were constructed. The distributions of electric fields, temperature, electrical conductivity, tissue injury and limitation on the pulse number required for IRE were calculated and compared. Results: Electrode length is an important geometric parameter for electrodes in the monopolar model (MPM), while electrode spacing affects the outcomes in the bipolar model (BPM). Increasing the pulse voltage reduces the pulse number required for tissue ablation, while increasing the risk of TI. In total, there were 6 NT-IRE protocols, 12 thermal-IRE protocols and 30 TI protocols. All of the NT-IRE protocols were set in BPMs with a voltage of 0.50 kV. With increasing electrode spacing, the minimum pulse number decreased. However, thermal effects were inevitable in the MPM. Conclusions: The electrode configuration and pulse settings are adjusted to achieve NT-IRE synergistically. The BPM is more reliable for achieving NT-IRE in 4-mm-thick digestive wall. Future in vitro and in vivo studies are needed to support and validate this conclusion.
- 1 October 2016
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 223 (4) , e193
Transfusion of Older Red Blood Cells is Associated with Increased Incidence of Acute Kidney Injury after Orthotopic Liver Transplantation
- 1 October 2016
- Published by Wolters Kluwer Health in Journal of the American College of Surgeons
- Vol. 223 (4) , e193
Transfusion of Older Red Blood Cells is Associated with Increased Incidence of Acute Kidney Injury after Orthotopic Liver Transplantation