Kenya Yuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kenya Yuki has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Kazuo Tsubota
Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan; and
11 shared publications Koji M. Nishiguchi
Department of Ophthalmology, Nagoya University Graduate School of Medicine, Nagoya, Japan
6 shared publicationsRyo Tomita
Department of Ophthalmology, Nagoya University Graduate School of Medicine, Nagoya, Japan
6 shared publicationsTaro Kominami
Department of Ophthalmology, Nagoya University Graduate School of Medicine, Nagoya, Japan
6 shared publicationsShinji Ueno
Department of Ophthalmology, Hirosaki University Graduate School of Medicine, Hirosaki, Japan
5 shared publicationsTaiga Inooka
Ophthalmology, Nagoya University Graduate School of Medicine, Aichi, JPN
5 shared publications
Latest Publications
- Open Access
- 12 April 2026
- Published by Springer Nature in Cureus
- Vol. 18 (4)
Transscleral Micropulse Cyclophotocoagulation for the Treatment of Refractory Primary Congenital Glaucoma: A Case Series
Primary congenital glaucoma is a rare but vision-threatening disease. Transscleral micropulse cyclophotocoagulation (MPCPC) delivers diode laser energy in short pulses with intervening off periods, allowing tissue cooling and potentially reducing adjacent thermal damage. However, evidence on MPCPC for childhood glaucoma among Japanese patients remains limited. In this series, we describe our experience with MPCPC in refractory cases of primary congenital glaucoma.
- 12 April 2026
- Published by Springer Nature in Cureus
- Vol. 18 (4)
Open AccessTransscleral Micropulse Cyclophotocoagulation for the Treatment of Refractory Primary Congenital Glaucoma: A Case Series
Primary congenital glaucoma is a rare but vision-threatening disease. Transscleral micropulse cyclophotocoagulation (MPCPC) delivers diode laser energy in short pulses with intervening off periods, allowing tissue cooling and potentially reducing adjacent thermal damage. However, evidence on MPCPC for childhood glaucoma among Japanese patients remains limited. In this series, we describe our experience with MPCPC in refractory cases of primary congenital glaucoma.
- Open Access
- 12 March 2026
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (9) , 1-8
Longitudinal change in anterior chamber depth and its determinants: a median 4.9-year follow-up of 2,247 Japanese adults
- 12 March 2026
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 264 (9) , 1-8
Open AccessLongitudinal change in anterior chamber depth and its determinants: a median 4.9-year follow-up of 2,247 Japanese adults
- Open Access
- 2 February 2026
- Published by Springer Nature in Cureus
- Vol. 18 (2) , e102808
Transconjunctival Compression Sutures for Postoperative Hypotony After PRESERFLO MicroShunt Revision: A Case Report
This is a case in which postoperative hypotony following bleb revision after PRESERFLOTM MicroShunt (MicroShunt) implantation in exfoliation glaucoma was successfully managed using transconjunctival compression sutures. An 82-year-old man with exfoliation glaucoma underwent MicroShunt implantation in the right eye for uncontrolled intraocular pressure (IOP). Due to bleb failure, open bleb revision with mitomycin C was subsequently performed. On postoperative day 14, severe hypotony with circumferential kissing choroidal detachment developed, and transconjunctival compression sutures were placed on the distal tube segment posterior to the MicroShunt fin to reduce aqueous outflow. Following the procedure, IOP gradually increased from 6 mmHg to 10 mmHg, accompanied by complete resolution of the choroidal detachment. At two months of follow-up, IOP remained stable without glaucoma medications. Transconjunctival compression suturing may represent a simple and minimally invasive treatment option for managing postoperative hypotony after MicroShunt implantation.
- 2 February 2026
- Published by Springer Nature in Cureus
- Vol. 18 (2) , e102808
Open AccessTransconjunctival Compression Sutures for Postoperative Hypotony After PRESERFLO MicroShunt Revision: A Case Report
This is a case in which postoperative hypotony following bleb revision after PRESERFLOTM MicroShunt (MicroShunt) implantation in exfoliation glaucoma was successfully managed using transconjunctival compression sutures. An 82-year-old man with exfoliation glaucoma underwent MicroShunt implantation in the right eye for uncontrolled intraocular pressure (IOP). Due to bleb failure, open bleb revision with mitomycin C was subsequently performed. On postoperative day 14, severe hypotony with circumferential kissing choroidal detachment developed, and transconjunctival compression sutures were placed on the distal tube segment posterior to the MicroShunt fin to reduce aqueous outflow. Following the procedure, IOP gradually increased from 6 mmHg to 10 mmHg, accompanied by complete resolution of the choroidal detachment. At two months of follow-up, IOP remained stable without glaucoma medications. Transconjunctival compression suturing may represent a simple and minimally invasive treatment option for managing postoperative hypotony after MicroShunt implantation.
- Open Access
- 15 January 2026
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (3) , 101073
Association of High-Density Lipoprotein Cholesterol with Macular Structure in Nonglaucomatous Individuals
- 15 January 2026
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (3) , 101073
Open AccessAssociation of High-Density Lipoprotein Cholesterol with Macular Structure in Nonglaucomatous Individuals
- Open Access
- 20 November 2025
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (2) , 101011
Risk Factors for Adult Axial Length Elongation: A 5-Year Population-Based Cohort Study
- 20 November 2025
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (2) , 101011
Open AccessRisk Factors for Adult Axial Length Elongation: A 5-Year Population-Based Cohort Study
- Open Access
- 27 September 2025
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 40, 102440
Successful treatment of glaucoma in Sturge–Weber syndrome using PreserFlo™ microshunt with intraluminal stenting: a case report
- 27 September 2025
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 40, 102440
Open AccessSuccessful treatment of glaucoma in Sturge–Weber syndrome using PreserFlo™ microshunt with intraluminal stenting: a case report
- Open Access
- 8 July 2025
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 39, 102384
Preserflo™ microshunt for the treatment of refractory childhood glaucoma: A case series study
- 8 July 2025
- Published by Elsevier in American Journal of Ophthalmology Case Reports
- Vol. 39, 102384
Open AccessPreserflo™ microshunt for the treatment of refractory childhood glaucoma: A case series study
- Open Access
- 1 April 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14 (4) , 6
Comparison of the Humphrey Field Analyzer and MP-3 Microperimeter in Patients With Glaucoma, Classified by Severity and Misalignment of Test Points
To compare Nidek MP-3 microperimetry and ZEISS Humphrey Field Analyzer (HFA) visual field (VF) results in patients with primary open-angle glaucoma (POAG), classified by VF defect severity and to describe a novel method for simulating sensitivity distribution changes assumed to be due to fixation errors. This retrospective study used the MP-3 and HFA 10-2 tests to examine the VF in eyes with mild, moderate, or severe POAG, using 68 identical test points. Reliability indices and measurement durations were compared. The relationship between pointwise sensitivities of the devices was analyzed. Thirty-five eyes from 23 patients (10 mild, 12 moderate, and 13 severe POAG) were evaluated. In the severe POAG group, the MP-3 had a significantly lower false-positive (FP) rate and higher false-negative rate than those of the HFA 10-2 (all, P = 0.03). A significant negative correlation existed between the root mean square error, derived from regression analysis comparing the VF sensitivity between devices at each test point, and VF sensitivity of the MP-3 (P < 0.01). In 18 eyes, a shift in the sensitivity distribution occurred, with a significant correlation between the HFA 10-2 mean deviation and the presence of this shift (P < 0.01). Reliability indices differed significantly between the two devices in severe POAG cases. A shift in the sensitivity of the test points of the two VF tests was detected in approximately one-half of the eyes. The MP-3 provides lower FP rates in advanced POAG and may assist in the management of this patient cohort.
- 1 April 2025
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 14 (4) , 6
Open AccessComparison of the Humphrey Field Analyzer and MP-3 Microperimeter in Patients With Glaucoma, Classified by Severity and Misalignment of Test Points
To compare Nidek MP-3 microperimetry and ZEISS Humphrey Field Analyzer (HFA) visual field (VF) results in patients with primary open-angle glaucoma (POAG), classified by VF defect severity and to describe a novel method for simulating sensitivity distribution changes assumed to be due to fixation errors. This retrospective study used the MP-3 and HFA 10-2 tests to examine the VF in eyes with mild, moderate, or severe POAG, using 68 identical test points. Reliability indices and measurement durations were compared. The relationship between pointwise sensitivities of the devices was analyzed. Thirty-five eyes from 23 patients (10 mild, 12 moderate, and 13 severe POAG) were evaluated. In the severe POAG group, the MP-3 had a significantly lower false-positive (FP) rate and higher false-negative rate than those of the HFA 10-2 (all, P = 0.03). A significant negative correlation existed between the root mean square error, derived from regression analysis comparing the VF sensitivity between devices at each test point, and VF sensitivity of the MP-3 (P < 0.01). In 18 eyes, a shift in the sensitivity distribution occurred, with a significant correlation between the HFA 10-2 mean deviation and the presence of this shift (P < 0.01). Reliability indices differed significantly between the two devices in severe POAG cases. A shift in the sensitivity of the test points of the two VF tests was detected in approximately one-half of the eyes. The MP-3 provides lower FP rates in advanced POAG and may assist in the management of this patient cohort.
- Open Access
- 5 December 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Assessment of factors affecting anterior chamber depth from data obtained from health checkup participants in Japan
Measurement of anterior chamber depth (ACD), an important marker for the screening of primary angle-closure glaucoma, requires biometry, which is not readily used. This study assessed the relationship between ACD and health check-up data findings from participants with good corrected visual acuity in Japan. Participants underwent ophthalmic, anthropometric, and hematological assessments. The mean ACD of all 3060 participants was 3.33 ± 0.34 mm [2.22–4.72 mm]. Multivariable linear regression analysis was performed to determine factors that were significantly correlated with ACD, and logistic regression analysis was performed to predict ACD < 2.70 mm. Multivariable linear regression analysis showed that age, sex, intraocular pressure, spherical equivalent refractive error (SER), height, and fasting blood sugar levels significantly correlated with ACD (P < 0.05). Logistic regression analysis showed that age, sex, and SER were the best predictors of ACD < 2.70 mm. The area under receiving operator characteristic curves of ‘age and SER’ and ‘age, SER, and sex’ were 0.821 and 0.835, respectively, with no significant difference (P = 0.122). In conclusion, ACD correlates with several parameters, and age and SER may be particularly important for predicting ACD in participants undergoing health checkups.
- 5 December 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Open AccessAssessment of factors affecting anterior chamber depth from data obtained from health checkup participants in Japan
Measurement of anterior chamber depth (ACD), an important marker for the screening of primary angle-closure glaucoma, requires biometry, which is not readily used. This study assessed the relationship between ACD and health check-up data findings from participants with good corrected visual acuity in Japan. Participants underwent ophthalmic, anthropometric, and hematological assessments. The mean ACD of all 3060 participants was 3.33 ± 0.34 mm [2.22–4.72 mm]. Multivariable linear regression analysis was performed to determine factors that were significantly correlated with ACD, and logistic regression analysis was performed to predict ACD < 2.70 mm. Multivariable linear regression analysis showed that age, sex, intraocular pressure, spherical equivalent refractive error (SER), height, and fasting blood sugar levels significantly correlated with ACD (P < 0.05). Logistic regression analysis showed that age, sex, and SER were the best predictors of ACD < 2.70 mm. The area under receiving operator characteristic curves of ‘age and SER’ and ‘age, SER, and sex’ were 0.821 and 0.835, respectively, with no significant difference (P = 0.122). In conclusion, ACD correlates with several parameters, and age and SER may be particularly important for predicting ACD in participants undergoing health checkups.