ALAlberto López-López

Alberto López-López

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alberto López-López has a total of 54 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Integrated Ozonation-Enzymatic Hydrolysis Pretreatment of Sugarcane Bagasse: Enhancement of Sugars Released to Expended Ozone Ratio

    by Daryl Rafael Osuna-Laveaga, Octavio García-Depraect, Ramiro Vallejo-Rodríguez, Alberto López-López, Elizabeth León-Becerril

    The combined effects of three key ozonation process parameters on the integrated ozonation-enzymatic hydrolysis pretreatment of sugarcane bagasse (SCB) were investigated, with emphasis on the relationship between sugar release and ozone consumption. A lab-scale fixed bed reactor was employed for ozonation at varying ozone doses (50, 75 and 100 mg O3/g SCB), particle sizes (420, 710 and 1000 µm) and moisture contents (30, 45 and 60% w/w) in multifactorial experiments, keeping a residence time of 30 min. The ozonated SCB showed a reduction in the content of acid-insoluble lignin from 26.6 down to 19.1% w/w, while those of cellulose and hemicellulose were retained above 45.5 and 13.6% w/w, with recoveries of 100–89.9 and 83.5–72.7%, respectively. Ozone-assisted enzymatic hydrolysis allowed attaining glucose and xylose yields as high as 45.0 and 37.8%, respectively. The sugars released/ozone expended ratio ranged between 2.3 and 5.7 g sugars/g O3, being the higher value achieved with an applied ozone input of 50 mg O3/g SCB and SCB with 420 µm particle size and 60% moisture. Such operating conditions led to efficient ozone utilization (<2% unreacted ozone) with a yield of 0.29 g sugars/g SCB. Overall, the amount of sugars released relative to the ozone consumed was improved, entailing an estimated cost of ozonation of USD 34.7/ton of SCB, which could enhance the profitability of the process.


  • Lactate- and acetate-based biohydrogen production through dark co-fermentation of tequila vinasse and nixtamalization wastewater: Metabolic and microbial community dynamics

    by Octavio García-Depraect, Idania Valdez-Vázquez, Eldon R. Rene, Jacob Gómez-Romero, Alberto López-López, Elizabeth León-Becerril


  • Open Access

    High-Strength Domestic Wastewater Treatment and Reuse with Onsite Passive Methods

    by José De Anda, Alberto López-López, Edgardo Villegas-García, Karla Valdivia-Aviña

    This paper describes the preliminary monitoring results of an onsite pilot wastewater treatment plant consisting of a septic tank, an anaerobic up-flow filter, and a horizontal subsurface flow wetland system planted with Agapanthus africanus. The system was designed to treat heavily polluted domestic wastewater produced in a research and development (R&D) center, reaching additional goals of zero energy consumption and eliminating the use of chemical additives. First water quality data shows that organic load in the treated sewage were removed achieving more than 95% efficiency. Nutrients were removed by almost 50%, and fecal and total coliform counts decreased by 99.96%. The results were compared to official Mexican regulations for wastewater discharged into lakes and reservoirs complied with all of them except for nutrients. In this pilot project, the resulting treated wastewater was directly reused for watering the green areas of the R&D center. The result was that the excess of nutrients improved the quality of the grass, avoiding the use of synthetic fertilizers, and created a wetland habitat for small wildlife species living in the area.


  • Open Access

    Occurrence and Potential Sources of Quinones Associated with PM2.5 in Guadalajara, Mexico

    by Adriana Barradas-Gimate, Mario Alfonso Murillo-Tovar, José De Jesús Díaz-Torres, Leonel Hernández-Mena, Hugo Saldarriaga-Noreña, Juana Maria Delgado-Saborit, Alberto López-López

    This study aims to establish the influence of primary emission sources and atmospheric transformation process contributing to the concentrations of quinones associated to particulate matter of less than 2.5 µm (PM2.5) in three sites within the Metropolitan Area of Guadalajara (MAG), namely Centro (CEN), Tlaquepaque (TLA) and Las Águilas (AGU). Environmental levels of quinones extracted from PM2.5 filters were analyzed using Gas Chromatography coupled to Mass Spectrometry (GC-MS). Overall, primary emissions in combination with photochemical and oxidation reactions contribute to the presence of quinones in the urban atmosphere of MAG. It was found that quinones in PM2.5 result from the contributions from direct emission sources by incomplete combustion of fossil fuels such as diesel and gasoline that relate mainly to vehicular activity intensity in the three sampling sites selected. However, this also suggests that the occurrence of quinones in MAG can be related to photochemical transformation of the parent Polycyclic Aromatic Hydrocarbons (PAHs), to chemical reactions with oxygenated species, or a combination of both routes. The higher concentration of 1,4-Chrysenequinone during the rainy season compared to the warm-dry season indicates chemical oxidation of chrysene, since the humidity could favor singlet oxygen collision with parent PAH present in the particle phase. On the contrary, 9,10-Anthraquinone/Anthracene and 1,4-Naftoquinone/Naphthalene ratios were higher during the warm-dry season compared to the rainy season, which might indicate a prevalence of the photochemical formation during the warm-dry season favored by the large solar radiation typical of the season. In addition, the estimated percentage of photochemical formation of 9,10-Phenanthrenequinone showed that the occurrence of this compound in Tlaquepaque (TLA) and Las Águilas (AGU) sites is mainly propagated by conditions of high solar radiation such as in the warm-dry season and during long periods of advection of air masses from emission to the reception areas. This was shown by the direct association between the number hourly back trajectories arriving in the TLA and AGU from Centro and other areas in MAG and the highest photochemical formation percentage.


  • A novel biohydrogen production process: Co-digestion of vinasse and Nejayote as complex raw substrates using a robust inoculum

    by Octavio García-Depraect, Jacob Gómez-Romero, Elizabeth León-Becerril, Alberto López-López


  • Endocrine-Disrupting Chemicals

    by Ramiro Vallejo-Rodríguez, Mario Murillo-Tovar, Leonel Hernández-Mena, Alberto López-López

  • Open Access

    Competitive kinetics versus stopped flow method for determining the degradation rate constants of steroids by ozonation

    by Alberto López-López, Valentín Flores-Payán, Elizabeth León-Becerril, Leonel Hernández-Mena, Ramiro Vallejo-Rodríguez

    Steroids are classified as endocrine disrupting chemicals; they are persistent with low biodegradability and are hardly degraded by conventional methods. Ozonation process has been effective for steroids degradation and the determination of the kinetics is a fundamental aspect for the design and operation of the reactor. This study assessed two methods: competitive kinetics and stopped flow, for determining the degradation kinetics of two steroids, estradiol (E2) and ethinylestradiol (EE2) in spiked water. Experiments were performed at pH 6, 21 °C, and using tertbutyl alcohol as scavenger of hydroxyl radicals; competitive kinetics method used sodium phenolate as reference compound. For the stopped flow, the experiments were performed in a BioLogic SFM-3000/S equipment. For both methods, the second order rate constants were in the order of 106 and 105 M−1 s−1 for E2 and EE2 respectively. The competitive kinetics can be applied with assurance and reliability but needing an additional analysis method to measure the residual concentrations. Stopped flow method allows the evaluation of the degradation kinetics in milliseconds and avoids the use of additional analytical methodologies; this method allows determining the reaction times on line. The methods are applicable for degradation of other emerging contaminants or other steroids and could be applied in water treatment at industrial level. Finally, it is important to consider the resources available to implement the most appropriate method, either competitive kinetics or the stopped-flow method.


  • Performance of an upflow anaerobic filter in the treatment of cold meat industry wastewater

    by Elizabeth León-Becerril, Jorge Eduardo García-Camacho, Jorge Del Real-Olvera, Alberto López-López


  • Influence of alkalinity and VFAs on the performance of an UASB reactor with recirculation for the treatment of Tequila vinasses

    by Alberto López-López, Elizabeth León-Becerril, María Elena Rosales-Contreras, Edgardo Villegas-García

    The main problem linked to the stability of upflow anaerobic sludge blanket (UASB) reactors during the treatment of Tequila vinasse is the high acidity and the null alkalinity present in this effluent. This research evaluates the effect of alkalinity and volatile fatty acids (VFAs) concentration on the performance of an UASB reactor with recirculation of the effluent for removing organic matter and biogas production from Tequila vinasses. Recirculation of the effluent reduces the impact of VFAs and organic matter concentration present in the influent, inducing the stability of the reactor. The UASB reactor was operated during 235 days at organic loading rates from 2.5 to 20.0 kg m−3 d−1, attaining a removal efficiency of COD greater than 75% with a methane yield of 335 ml CH4 g−1 COD at SPT, maintaining a ratio of VFAs/Alk ≤ 0.5. Therefore, an optimal ratio of VFAs/Alk was established for the system operating in stable conditions for the treatment of Tequila vinasses. Under these conditions, the alkalinity was recuperated by the system itself, without the addition of external alkalinity.


  • Open Access

    The Effect of the Hydraulic Retention Time on the Performance of an Ecological Wastewater Treatment System: An Anaerobic Filter with a Constructed Wetland

    by María L. Merino-Solís, Edgardo Villegas, José De Anda, Alberto López-López

    This work assesses the performance of a municipal pilot wastewater treatment system employing an up-flow anaerobic filter (UAF) followed by a horizontal subsurface constructed wetland (HSSCW). This pilot scale demonstration project was implemented in a zone with subtropical climate in order to protect Lake Chapala from wastewater loads that are discharged by small communities in the Lake’s vicinity. The filters were filled with tezontle as the media for biofilm support and the HSSCW was planted with two ornamental plants species, Canna hybrids and Strelitzia reginae. The experiment evaluated three hydraulic retention times (HRT) of 18, 28 and 38 h in the UAF, which corresponds to two, three and four days in HSSCW over 66 weeks. The mean efficiencies found for the complete system were 80% and 90% of BOD, 80% and 86% of COD, 30% and 33% of Ntot and between 24% and 44% of Ptot. It was possible to remove almost 80% of organic matter in 18 h in the UAF while the HSSCW reached 30% of removal for Ntot in a HRT of three days. As expected, the UAF was responsible for removing most of the organic matter and the HSSCW removed most of the nitrogen.