Dongping Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Dongping Wang has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Hanbin Ma
University of Electronic Science and Technology of China
8 shared publications - Jun Yu
School of Information Science and Engineering, Shandong University, Qingdao, China
8 shared publications Shengzhe Jiang
Shandong University
4 shared publications- Arokia Nathan
School of Information Science and Engineering, Shandong University, Qingdao, China
3 shared publications Kai Jin
CAS Key Laboratory of Bio-medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, No. 88 Keling Road, Suzhou, Jiangsu Province, 215163, P. R. China
3 shared publicationsArokia Nathan
School of Information Science and Engineering, Shandong University, Qingdao 266237, P.R. China
2 shared publications
Latest Publications
- 21 November 2025
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 3 (1) , 46-60
Active-matrix digital microfluidics for high-throughput, precise droplet handling
- 21 November 2025
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 3 (1) , 46-60
Active-matrix digital microfluidics for high-throughput, precise droplet handling
- Open Access
Designing Highly Reversible and Stable Zn Anodes for Next-Generation Aqueous Batteries
The global imperative for sustainable energy has catalyzed the pursuit of next-generation energy storage technologies that are intrinsically safe, economically viable, and scalable. Aqueous zinc-ion batteries (AZIBs) present a promising solution to meet these demands. However, the metallic Zn anode, the heart of this technology, suffers from fundamental electrochemical instabilities—manifesting as dendrite growth and rampant parasitic reactions (e.g., corrosion and passivation)—that critically curtail battery lifespan and impede practical application. This review offers a comprehensive overview of the latest strategies designed to achieve a highly reversible and stable Zn anode. We meticulously categorize and analyze these innovations through the three integral components of the AZIBs: (i) intrinsic anode engineering, (ii) interfacial electrolyte chemistry regulation, and (iii) separator-induced transport modulation. By delving into the core scientific mechanisms and critically evaluating each approach, this work synthesizes a holistic understanding of the structure-property-performance relationships. We conclude by identifying the persistent challenges and, more importantly, proposing visionary perspectives on future research directions. This review aims to serve as a scientific guide for the rational design of highly reversible Zn anodes, paving the way for the next generation of high-performance, commercially viable aqueous batteries.
Open AccessDesigning Highly Reversible and Stable Zn Anodes for Next-Generation Aqueous Batteries
The global imperative for sustainable energy has catalyzed the pursuit of next-generation energy storage technologies that are intrinsically safe, economically viable, and scalable. Aqueous zinc-ion batteries (AZIBs) present a promising solution to meet these demands. However, the metallic Zn anode, the heart of this technology, suffers from fundamental electrochemical instabilities—manifesting as dendrite growth and rampant parasitic reactions (e.g., corrosion and passivation)—that critically curtail battery lifespan and impede practical application. This review offers a comprehensive overview of the latest strategies designed to achieve a highly reversible and stable Zn anode. We meticulously categorize and analyze these innovations through the three integral components of the AZIBs: (i) intrinsic anode engineering, (ii) interfacial electrolyte chemistry regulation, and (iii) separator-induced transport modulation. By delving into the core scientific mechanisms and critically evaluating each approach, this work synthesizes a holistic understanding of the structure-property-performance relationships. We conclude by identifying the persistent challenges and, more importantly, proposing visionary perspectives on future research directions. This review aims to serve as a scientific guide for the rational design of highly reversible Zn anodes, paving the way for the next generation of high-performance, commercially viable aqueous batteries.
- Open Access
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of the Electron Devices Society
- Vol. 13, 1209-1213
Integrated Droplet Driving and Sensing Circuit for Enhanced Position Feedback in AM-DMF System
With the increasing throughput of droplet manipulation and the decreasing droplet size in the active-matrix digital microfluidics (AM-DMF) system, achieving a precise and stable control of small droplets has become an urgent issue. This paper proposes a hydrogenated amorphous silicon thin film transistor (a-Si: H TFT)-based capacitive droplet position sensing circuit. This circuit integrates droplet driving and sensing functions effectively. The variance of sensing outputs for different droplet samples and load-driving ability are enhanced by introducing an inverter serving as the inverting amplifier. Simulation results show that this circuit can stably provide driving voltages over 46 V and achieve a sensing output variance of 25 V between deionized (DI) water and silicone oil. Tests of the other two samples have also been conducted. The applicability of this circuit in high-throughput arrays has also been verified. In a 12 W 10 array filled with oil-surrounded DI water, the sensing output variance remains over 22 V. This circuit demonstrates the potential of driving droplets and supplying effective droplet position feedback for the high-throughput AM-DMF system, enabling the closed-loop droplet control.
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of the Electron Devices Society
- Vol. 13, 1209-1213
Open AccessIntegrated Droplet Driving and Sensing Circuit for Enhanced Position Feedback in AM-DMF System
With the increasing throughput of droplet manipulation and the decreasing droplet size in the active-matrix digital microfluidics (AM-DMF) system, achieving a precise and stable control of small droplets has become an urgent issue. This paper proposes a hydrogenated amorphous silicon thin film transistor (a-Si: H TFT)-based capacitive droplet position sensing circuit. This circuit integrates droplet driving and sensing functions effectively. The variance of sensing outputs for different droplet samples and load-driving ability are enhanced by introducing an inverter serving as the inverting amplifier. Simulation results show that this circuit can stably provide driving voltages over 46 V and achieve a sensing output variance of 25 V between deionized (DI) water and silicone oil. Tests of the other two samples have also been conducted. The applicability of this circuit in high-throughput arrays has also been verified. In a 12 W 10 array filled with oil-surrounded DI water, the sensing output variance remains over 22 V. This circuit demonstrates the potential of driving droplets and supplying effective droplet position feedback for the high-throughput AM-DMF system, enabling the closed-loop droplet control.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 15809-15821
A Hybrid Closed-Loop Droplet Detection for Digital Microfluidics
Aiming at the key technical difficulties of droplet detection in digital microfluidic chips, we propose a closed-loop feedback system combining electrical impedance and image sensing technology. The system integrates the image processing algorithm based on YOLOv5 and impedance sensing technology to achieve accurate detection of droplets. With only 500 training samples, the detection accuracy of the YOLOv5 reaches over 95%, which improves the efficiency and accuracy of droplet recognition. In addition, we develop a self-adjusting mechanism that can automatically plan the path and guide the target droplet to effectively bypass the faulty electrode and accurately reach the target position. The success rate reached 100% in 50 tests, which greatly enhanced the stability and reliability of the system. Through electrical impedance detection, the quantitative relationship between the droplet volume and the detection value was further explored. The single-electrode droplet volume detection time is only about 1.5 ms, and the effective detection resolution is 0.15 μL. This work achieved a deep combination of electrical impedance and image sensing technology in droplet detection, and optimized the digital microfluidic droplet detection system. It not only provided a more reliable and stable experimental platform for biochemical experiments, but also provided new ideas and directions for the development of intelligent microfluidic detection systems and the realization of automated and intelligent droplet detection and analysis.
- 28 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (9) , 15809-15821
A Hybrid Closed-Loop Droplet Detection for Digital Microfluidics
Aiming at the key technical difficulties of droplet detection in digital microfluidic chips, we propose a closed-loop feedback system combining electrical impedance and image sensing technology. The system integrates the image processing algorithm based on YOLOv5 and impedance sensing technology to achieve accurate detection of droplets. With only 500 training samples, the detection accuracy of the YOLOv5 reaches over 95%, which improves the efficiency and accuracy of droplet recognition. In addition, we develop a self-adjusting mechanism that can automatically plan the path and guide the target droplet to effectively bypass the faulty electrode and accurately reach the target position. The success rate reached 100% in 50 tests, which greatly enhanced the stability and reliability of the system. Through electrical impedance detection, the quantitative relationship between the droplet volume and the detection value was further explored. The single-electrode droplet volume detection time is only about 1.5 ms, and the effective detection resolution is 0.15 μL. This work achieved a deep combination of electrical impedance and image sensing technology in droplet detection, and optimized the digital microfluidic droplet detection system. It not only provided a more reliable and stable experimental platform for biochemical experiments, but also provided new ideas and directions for the development of intelligent microfluidic detection systems and the realization of automated and intelligent droplet detection and analysis.
- 31 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
- Vol. 44 (7) , 2683-2696
Optimization of Droplet Routing in Microfluidic Biochips Using Calibrated Droplet-Shape Morphing
Advanced digital microfluidic biochips based on technologies such as micro-electrode-dot-array (MEDA) and active matrix (AM) provide enhanced functionality compared to conventional biochips. Owing to the larger ratio of droplet size to electrode size, these platforms allow finer control of droplets and diagonal movement. Additionally, they allow dynamic grouping of micro-electrodes to form subsystems that can perform fluidic operations. Shape morphing is a key feature of MEDA/AM biochips that results in faster fluidic operations, thereby improving the efficiency of bioassays. To establish the benefits of shape morphing, we first numerically simulate the shape morphing operation. We employ a simplified 2-D flow model incorporating interface tracking through a level-set method to numerically simulate shape morphing induced by micro-electrode actuation. We also validate our numerical results with COMSOL simulations and experiments performed on MEDA/AM biochips. The validated shape morphing operations are subsequently used to optimize droplet routing for benchmark bioassays. We propose an algorithm to significantly reduce the size of the routing problem and the time needed to solve it. With the help of this improved approach, we show that droplet morphing operations reduce the time needed to complete bioassays.
- 31 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
- Vol. 44 (7) , 2683-2696
Optimization of Droplet Routing in Microfluidic Biochips Using Calibrated Droplet-Shape Morphing
Advanced digital microfluidic biochips based on technologies such as micro-electrode-dot-array (MEDA) and active matrix (AM) provide enhanced functionality compared to conventional biochips. Owing to the larger ratio of droplet size to electrode size, these platforms allow finer control of droplets and diagonal movement. Additionally, they allow dynamic grouping of micro-electrodes to form subsystems that can perform fluidic operations. Shape morphing is a key feature of MEDA/AM biochips that results in faster fluidic operations, thereby improving the efficiency of bioassays. To establish the benefits of shape morphing, we first numerically simulate the shape morphing operation. We employ a simplified 2-D flow model incorporating interface tracking through a level-set method to numerically simulate shape morphing induced by micro-electrode actuation. We also validate our numerical results with COMSOL simulations and experiments performed on MEDA/AM biochips. The validated shape morphing operations are subsequently used to optimize droplet routing for benchmark bioassays. We propose an algorithm to significantly reduce the size of the routing problem and the time needed to solve it. With the help of this improved approach, we show that droplet morphing operations reduce the time needed to complete bioassays.
- 29 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 45 (7) , 1361-1364
Droplet Position Sensing in TFT Active-Matrix Digital Microfluidics
This paper presents a droplet position sensing circuit designed for thin film transistor active-matrix digital microfluidics. The presented pixel design facilitates simultaneous implementation of droplet driving and position sensing functions. An 8x8 array was fabricated with standard thin film transistors compatible to mainstream display backplane technology. Measured results indicate a difference in output voltage of approximately 4 V between deionized water and air, demonstrating ample precision for accurate droplet position sensing. The driving and readout capability of the array has also been experimentally verified. The approach presented here is suitable for integration of TFT active-matrix digital microfluidics, offering a solution to enhance the efficiency and precision of droplet manipulation.
- 29 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Electron Device Letters
- Vol. 45 (7) , 1361-1364
Droplet Position Sensing in TFT Active-Matrix Digital Microfluidics
This paper presents a droplet position sensing circuit designed for thin film transistor active-matrix digital microfluidics. The presented pixel design facilitates simultaneous implementation of droplet driving and position sensing functions. An 8x8 array was fabricated with standard thin film transistors compatible to mainstream display backplane technology. Measured results indicate a difference in output voltage of approximately 4 V between deionized water and air, demonstrating ample precision for accurate droplet position sensing. The driving and readout capability of the array has also been experimentally verified. The approach presented here is suitable for integration of TFT active-matrix digital microfluidics, offering a solution to enhance the efficiency and precision of droplet manipulation.
- Open Access
- 27 February 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (8) , 2193-2201
Polar coordinate active-matrix digital microfluidics for high-resolution concentration gradient generation
Advancing active-matrix digital microfluidics through polar coordinates for precise concentration gradients. Demonstrated with chip photography, concentration gradient solution demo, and efficiency comparison.
- 27 February 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 24 (8) , 2193-2201
Open AccessPolar coordinate active-matrix digital microfluidics for high-resolution concentration gradient generation
Advancing active-matrix digital microfluidics through polar coordinates for precise concentration gradients. Demonstrated with chip photography, concentration gradient solution demo, and efficiency comparison.
- Open Access
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of the Electron Devices Society
- Vol. 11, 411-415
Active-Matrix Digital Microfluidics Design and Optimization for High-Throughput Droplets Manipulation
Emerging microfluidic tools are bringing new approaches to biological experiments on the scale of microdroplets and single cells. In this study, we designed an active-matrix digital microfluidics chip and investigated a driving signal strategy. The driving factors of ‘holding time’ and ‘delay time’ in the activematrix drive timing and the stability of droplet manipulation were optimized. Then, the drive signal was optimized to finally achieve the stable control of two different single high-throughput droplets. In this process, we also investigated how to maintain the stability of droplet driving while reducing the electrode degradation, extending the electrode and TFT circuit life and increasing the duration of the AM-DMF chip. The above work provides experience in the stable manipulation of single cells and the application of high-throughput droplet driving while allowing for cost savings.
- 7 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of the Electron Devices Society
- Vol. 11, 411-415
Open AccessActive-Matrix Digital Microfluidics Design and Optimization for High-Throughput Droplets Manipulation
Emerging microfluidic tools are bringing new approaches to biological experiments on the scale of microdroplets and single cells. In this study, we designed an active-matrix digital microfluidics chip and investigated a driving signal strategy. The driving factors of ‘holding time’ and ‘delay time’ in the activematrix drive timing and the stability of droplet manipulation were optimized. Then, the drive signal was optimized to finally achieve the stable control of two different single high-throughput droplets. In this process, we also investigated how to maintain the stability of droplet driving while reducing the electrode degradation, extending the electrode and TFT circuit life and increasing the duration of the AM-DMF chip. The above work provides experience in the stable manipulation of single cells and the application of high-throughput droplet driving while allowing for cost savings.