MLMin Liu

Min Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Min Liu has a total of 5 co-authors. Here are the top co-authors by number of shared publications:

  • Chun Wang

    Diabetic Foot Care Center, Department of Endocrinology and Metabolism, West China Hospital, Sichuan University, Chengdu 610041, China

    1 shared publication
  • Dawei Chen

    Innovation Center for Wound Repair Diabetic Foot Care Center Department of Endocrinology and Metabolism West China Hospital Sichuan University Chengdu China

    1 shared publication
  • Guan-Jian Liu

    Chinese Cochrane Center, Chinese EBM Center, West China Hospital, Sichuan University, Chengdu 610041, China

    1 shared publication
  • Jing Ma

    Department of Endocrinology and Metabolism, Gansu Provincial Hospital, Gansu Branch of National Clinical Research Centre for Metabolic Diseases, Lanzhou, China; The First Clinical Medical College of Lanzhou University, Lanzhou, China

    1 shared publication
  • Xingwu Ran

    Department of Endocrinology and Metabolism, Innovation Center for Wound Repair, Diabetic Foot Care Center, West China Hospital, Sichuan University, China

    1 shared publication

Latest Publications

  • Open Access

    The Validity and Reliability between Automated Oscillometric Measurement of Ankle-Brachial Index and Standard Measurement by Eco-Doppler in Diabetic Patients with or without Diabetic Foot

    by Jing Ma, Min Liu, Dawei Chen, Chun Wang, Guanjian Liu, Xingwu Ran

    Objective. To evaluate the concordance between oscillometric ABI and standard Doppler ABI in diabetic Chinese patients with or without diabetic foot. Methods. 230 consecutive diabetic patients (n=459 limbs) were included. The right and left ABIs were determined with both devices by the same investigator. The concordance and agreement were assessed by kappa index and the Bland-Altman method. Results. The average Doppler ABI was 1.003 ± 0.286 on the right and 0.990 ± 0.287 on the left, while oscillometric ABI was 1.002 ± 0.332 and 0.993 ± 0.319, which had no significance. The average time for oscillometric ABI was 8.600 versus 16.980 minutes for Doppler ABI (p<0.001). There was good agreement between the two measurements, with a kappa value of 0.869 on the right and 0.919 on the left. Regarding the Doppler ABI as the gold standard, the accuracy, sensitivity, specificity, +LR, and −LR of oscillometric ABI reached 95.22%, 94.34%, 95.48%, 20.873%, and 0.059% on the right. For the left, it was 96.94%, 96.43%, 97.11%, 33.364%, and 0.036%. Conclusions. The oscillometric measurement is a reliable, convenient, and less time-consuming alternative to standard Doppler ABI in patients. It should be widely used for PAD detection.