Bhargava Chinni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bhargava Chinni has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Ari Cedars
Division of Cardiology, Johns Hopkins School of Medicine, Baltimore, MD
3 shared publications - Cedric Manlhiot
Labatt Family Heart Centre, Department of Pediatrics, The University of Toronto, Hospital for Sick Children, Toronto, Ontario, Canada
3 shared publications - Shelby Kutty
BayCare Health System
3 shared publications - Allen Dale Everett
Blalock-Taussig-Thomas Congenital Heart Center, Department of Pediatrics, Johns Hopkins University, Baltimore, MD (B.K.C., A.D.E.).
2 shared publications Cedric Manlhiot
Division of Cardiology, Department of Pediatrics, University of Toronto, Labatt Family Heart Centre, The Hospital for Sick Children, Canada (C.M.).
2 shared publications- Danielle Gottlieb Sen
Le Bonheur Children's Hospital, 49 N Dunlap 3rd floor, Memphis, TN 38105
2 shared publications
Latest Publications
- 1 September 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (9) , 805-818
The Pediatric Pulmonary Hypertension International Risk Score: A Prediction Model for Outcomes Using Machine Learning
BACKGROUND: Risk prediction is fundamental to pulmonary hypertension (PH) guideline-based care, yet pediatric-specific risk prediction models remain limited, relying primarily on single predictors, expert opinion, or application of adult models to children. The authors developed and externally validated a data-driven 1-year risk prediction model for pediatric PH. METHODS: Pediatric patients with PH (n=345; World Symposium on Pulmonary Hypertension groups 1 and 3) enrolled in the Pediatric Pulmonary Hypertension Network Registry (2014–2020; 50.4% male; median age, 4.9 years [interquartile range, 1.9–10.3]) were split into training (80%) and test cohorts (20%). The Dutch National Registry for Pulmonary Hypertension in Childhood (n=155 [1993–2020]) and the Spanish Registry of Pediatric Pulmonary Hypertension (n=327 [2009–2023]) were used for external validation. From 176 variables, BorutaSHAP feature selection with random forest identified 16 predictors for a 1-year outcome of time to death, transplant, Potts shunt, or atrial septostomy, modeled using extreme gradient boosting. Performance was assessed with the area under the receiver operating characteristic curve, confusion matrices, calibration, and Kaplan-Meier event-free survival. RESULTS: The final model achieved an area under the receiver operating characteristic curve of 0.90 (0.79–0.97) and 99% (96%–99%) negative predictive value in testing, dividing participants into 3 groups with strong outcome discrimination. External validation showed an area under the receiver operating characteristic curve of 0.76 (Dutch National Registry for Pulmonary Hypertension in Childhood, 0.70–0.81) and 0.77 (Spanish Registry of Pediatric Pulmonary Hypertension, 0.73–0.82) with negative predictive values of 93% (93%–97%) and 96% (93%–97%), respectively. Kaplan-Meier analysis significantly differentiated outcomes by risk group. CONCLUSIONS: This multicenter, validated model provides good 1-year risk prediction in pediatric PH across World Symposium on Pulmonary Hypertension groups 1 and 3, providing a robust tool for clinical risk stratification to guide therapy and addressing a gap in pediatric PH care.
- 1 September 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 154 (9) , 805-818
The Pediatric Pulmonary Hypertension International Risk Score: A Prediction Model for Outcomes Using Machine Learning
BACKGROUND: Risk prediction is fundamental to pulmonary hypertension (PH) guideline-based care, yet pediatric-specific risk prediction models remain limited, relying primarily on single predictors, expert opinion, or application of adult models to children. The authors developed and externally validated a data-driven 1-year risk prediction model for pediatric PH. METHODS: Pediatric patients with PH (n=345; World Symposium on Pulmonary Hypertension groups 1 and 3) enrolled in the Pediatric Pulmonary Hypertension Network Registry (2014–2020; 50.4% male; median age, 4.9 years [interquartile range, 1.9–10.3]) were split into training (80%) and test cohorts (20%). The Dutch National Registry for Pulmonary Hypertension in Childhood (n=155 [1993–2020]) and the Spanish Registry of Pediatric Pulmonary Hypertension (n=327 [2009–2023]) were used for external validation. From 176 variables, BorutaSHAP feature selection with random forest identified 16 predictors for a 1-year outcome of time to death, transplant, Potts shunt, or atrial septostomy, modeled using extreme gradient boosting. Performance was assessed with the area under the receiver operating characteristic curve, confusion matrices, calibration, and Kaplan-Meier event-free survival. RESULTS: The final model achieved an area under the receiver operating characteristic curve of 0.90 (0.79–0.97) and 99% (96%–99%) negative predictive value in testing, dividing participants into 3 groups with strong outcome discrimination. External validation showed an area under the receiver operating characteristic curve of 0.76 (Dutch National Registry for Pulmonary Hypertension in Childhood, 0.70–0.81) and 0.77 (Spanish Registry of Pediatric Pulmonary Hypertension, 0.73–0.82) with negative predictive values of 93% (93%–97%) and 96% (93%–97%), respectively. Kaplan-Meier analysis significantly differentiated outcomes by risk group. CONCLUSIONS: This multicenter, validated model provides good 1-year risk prediction in pediatric PH across World Symposium on Pulmonary Hypertension groups 1 and 3, providing a robust tool for clinical risk stratification to guide therapy and addressing a gap in pediatric PH care.
- Open Access
- 1 April 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (7) , e038061
Methylated Arginine Metabolites as Biomarkers for Clinical Status and Response to Type 5 Phosphodiesterase Inhibition in Patients With Fontan Circulation
Background: There is significant interest in NO pathway modulators, specifically type 5 phosphodiesterase inhibitors (PDE5is), to treat patients with a Fontan circulation. Trials, however, have had mixed results. The relationship between the NO pathway and clinical status in patients with Fontan circulation is a significant knowledge gap. Methods and Results: We performed targeted metabolomic analysis using liquid chromatography coupled to mass spectrometry to quantify plasma NO pathway metabolite concentrations from 2 well‐characterized populations of patients with Fontan circulation: the Boston Adult Congenital Heart Disease Biobank and Fontan Udenafil Exercise Longitudinal studies. We investigated associations between NO metabolite concentrations and clinical outcomes, exercise capacity, and response to PDE5is. Increased plasma concentration of asymmetric dimethyl arginine (ADMA), an inhibitor of NO production, was associated with risk for hospitalization or death. Increased ADMA and symmetric dimethyl arginine (another inhibitor of NO production) concentrations were associated with decreased baseline exercise capacity among patients with Fontan circulation with <90% predicted peak oxygen uptake, and change in ADMA and symmetric dimethyl arginine concentrations were predictive of change in exercise capacity over time. Treatment with the PDE5i udenafil uncoupled this association. Finally, baseline ADMA and symmetric dimethyl arginine concentrations predicted response to PDE5is among patients with subnormal peak oxygen uptake. Conclusions: Plasma concentrations of metabolites that inhibit NO flux are associated with negative clinical outcomes and worse exercise capacity. Moreover, metabolite shifts over time associated with increased NO flux are associated with improved exercise capacity. In patients with a Fontan circulation, the NO pathway modulators ADMA and symmetric dimethyl arginine may be useful as biomarkers of clinical status and predictive of response to PDE5is.
- 1 April 2025
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 14 (7) , e038061
Open AccessMethylated Arginine Metabolites as Biomarkers for Clinical Status and Response to Type 5 Phosphodiesterase Inhibition in Patients With Fontan Circulation
Background: There is significant interest in NO pathway modulators, specifically type 5 phosphodiesterase inhibitors (PDE5is), to treat patients with a Fontan circulation. Trials, however, have had mixed results. The relationship between the NO pathway and clinical status in patients with Fontan circulation is a significant knowledge gap. Methods and Results: We performed targeted metabolomic analysis using liquid chromatography coupled to mass spectrometry to quantify plasma NO pathway metabolite concentrations from 2 well‐characterized populations of patients with Fontan circulation: the Boston Adult Congenital Heart Disease Biobank and Fontan Udenafil Exercise Longitudinal studies. We investigated associations between NO metabolite concentrations and clinical outcomes, exercise capacity, and response to PDE5is. Increased plasma concentration of asymmetric dimethyl arginine (ADMA), an inhibitor of NO production, was associated with risk for hospitalization or death. Increased ADMA and symmetric dimethyl arginine (another inhibitor of NO production) concentrations were associated with decreased baseline exercise capacity among patients with Fontan circulation with <90% predicted peak oxygen uptake, and change in ADMA and symmetric dimethyl arginine concentrations were predictive of change in exercise capacity over time. Treatment with the PDE5i udenafil uncoupled this association. Finally, baseline ADMA and symmetric dimethyl arginine concentrations predicted response to PDE5is among patients with subnormal peak oxygen uptake. Conclusions: Plasma concentrations of metabolites that inhibit NO flux are associated with negative clinical outcomes and worse exercise capacity. Moreover, metabolite shifts over time associated with increased NO flux are associated with improved exercise capacity. In patients with a Fontan circulation, the NO pathway modulators ADMA and symmetric dimethyl arginine may be useful as biomarkers of clinical status and predictive of response to PDE5is.
- 7 August 2024
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 40 (10) , 1880-1896
Emerging Analytical Approaches for Personalized Medicine Using Machine Learning In Pediatric and Congenital Heart Disease
- 7 August 2024
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 40 (10) , 1880-1896
Emerging Analytical Approaches for Personalized Medicine Using Machine Learning In Pediatric and Congenital Heart Disease
- Open Access
- 3 May 2023
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 7 (1) , e40524
Data Quality Degradation on Prediction Models Generated From Continuous Activity and Heart Rate Monitoring: Exploratory Analysis Using Simulation
Background: Limited data accuracy is often cited as a reason for caution in the integration of physiological data obtained from consumer-oriented wearable devices in care management pathways. The effect of decreasing accuracy on predictive models generated from these data has not been previously investigated. Objective: The aim of this study is to simulate the effect of data degradation on the reliability of prediction models generated from those data and thus determine the extent to which lower device accuracy might or might not limit their use in clinical settings. Methods: Using the Multilevel Monitoring of Activity and Sleep in Healthy People data set, which includes continuous free-living step count and heart rate data from 21 healthy volunteers, we trained a random forest model to predict cardiac competence. Model performance in 75 perturbed data sets with increasing missingness, noisiness, bias, and a combination of all 3 perturbations was compared to model performance for the unperturbed data set. Results: The unperturbed data set achieved a mean root mean square error (RMSE) of 0.079 (SD 0.001) in predicting cardiac competence index. For all types of perturbations, RMSE remained stable up to 20%-30% perturbation. Above this level, RMSE started increasing and reached the point at which the model was no longer predictive at 80% for noise, 50% for missingness, and 35% for the combination of all perturbations. Introducing systematic bias in the underlying data had no effect on RMSE. Conclusions: In this proof-of-concept study, the performance of predictive models for cardiac competence generated from continuously acquired physiological data was relatively stable with declining quality of the source data. As such, lower accuracy of consumer-oriented wearable devices might not be an absolute contraindication for their use in clinical prediction models.
- 3 May 2023
- Published by JMIR Publications Inc. in JMIR Cardio
- Vol. 7 (1) , e40524
Open AccessData Quality Degradation on Prediction Models Generated From Continuous Activity and Heart Rate Monitoring: Exploratory Analysis Using Simulation
Background: Limited data accuracy is often cited as a reason for caution in the integration of physiological data obtained from consumer-oriented wearable devices in care management pathways. The effect of decreasing accuracy on predictive models generated from these data has not been previously investigated. Objective: The aim of this study is to simulate the effect of data degradation on the reliability of prediction models generated from those data and thus determine the extent to which lower device accuracy might or might not limit their use in clinical settings. Methods: Using the Multilevel Monitoring of Activity and Sleep in Healthy People data set, which includes continuous free-living step count and heart rate data from 21 healthy volunteers, we trained a random forest model to predict cardiac competence. Model performance in 75 perturbed data sets with increasing missingness, noisiness, bias, and a combination of all 3 perturbations was compared to model performance for the unperturbed data set. Results: The unperturbed data set achieved a mean root mean square error (RMSE) of 0.079 (SD 0.001) in predicting cardiac competence index. For all types of perturbations, RMSE remained stable up to 20%-30% perturbation. Above this level, RMSE started increasing and reached the point at which the model was no longer predictive at 80% for noise, 50% for missingness, and 35% for the combination of all perturbations. Introducing systematic bias in the underlying data had no effect on RMSE. Conclusions: In this proof-of-concept study, the performance of predictive models for cardiac competence generated from continuously acquired physiological data was relatively stable with declining quality of the source data. As such, lower accuracy of consumer-oriented wearable devices might not be an absolute contraindication for their use in clinical prediction models.
- Open Access
- 24 June 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Data Quality Degradation on Prediction Models Generated From Continuous Activity and Heart Rate Monitoring: Exploratory Analysis Using Simulation (Preprint)
BACKGROUND Limited data accuracy is often cited as a reason for caution in the integration of physiological data obtained from consumer-oriented wearable devices in care management pathways. The effect of decreasing accuracy on predictive models generated from these data has not been previously investigated. OBJECTIVE The aim of this study is to simulate the effect of data degradation on the reliability of prediction models generated from those data and thus determine the extent to which lower device accuracy might or might not limit their use in clinical settings. METHODS Using the Multilevel Monitoring of Activity and Sleep in Healthy People data set, which includes continuous free-living step count and heart rate data from 21 healthy volunteers, we trained a random forest model to predict cardiac competence. Model performance in 75 perturbed data sets with increasing missingness, noisiness, bias, and a combination of all 3 perturbations was compared to model performance for the unperturbed data set. RESULTS The unperturbed data set achieved a mean root mean square error (RMSE) of 0.079 (SD 0.001) in predicting cardiac competence index. For all types of perturbations, RMSE remained stable up to 20%-30% perturbation. Above this level, RMSE started increasing and reached the point at which the model was no longer predictive at 80% for noise, 50% for missingness, and 35% for the combination of all perturbations. Introducing systematic bias in the underlying data had no effect on RMSE. CONCLUSIONS In this proof-of-concept study, the performance of predictive models for cardiac competence generated from continuously acquired physiological data was relatively stable with declining quality of the source data. As such, lower accuracy of consumer-oriented wearable devices might not be an absolute contraindication for their use in clinical prediction models.
- 24 June 2022
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessData Quality Degradation on Prediction Models Generated From Continuous Activity and Heart Rate Monitoring: Exploratory Analysis Using Simulation (Preprint)
BACKGROUND Limited data accuracy is often cited as a reason for caution in the integration of physiological data obtained from consumer-oriented wearable devices in care management pathways. The effect of decreasing accuracy on predictive models generated from these data has not been previously investigated. OBJECTIVE The aim of this study is to simulate the effect of data degradation on the reliability of prediction models generated from those data and thus determine the extent to which lower device accuracy might or might not limit their use in clinical settings. METHODS Using the Multilevel Monitoring of Activity and Sleep in Healthy People data set, which includes continuous free-living step count and heart rate data from 21 healthy volunteers, we trained a random forest model to predict cardiac competence. Model performance in 75 perturbed data sets with increasing missingness, noisiness, bias, and a combination of all 3 perturbations was compared to model performance for the unperturbed data set. RESULTS The unperturbed data set achieved a mean root mean square error (RMSE) of 0.079 (SD 0.001) in predicting cardiac competence index. For all types of perturbations, RMSE remained stable up to 20%-30% perturbation. Above this level, RMSE started increasing and reached the point at which the model was no longer predictive at 80% for noise, 50% for missingness, and 35% for the combination of all perturbations. Introducing systematic bias in the underlying data had no effect on RMSE. CONCLUSIONS In this proof-of-concept study, the performance of predictive models for cardiac competence generated from continuously acquired physiological data was relatively stable with declining quality of the source data. As such, lower accuracy of consumer-oriented wearable devices might not be an absolute contraindication for their use in clinical prediction models.
- Open Access
- 1 March 2019
- Published by Elsevier in Photoacoustics
- Vol. 13, 85-94
Multiview spatial compounding using lens-based photoacoustic imaging system
- 1 March 2019
- Published by Elsevier in Photoacoustics
- Vol. 13, 85-94
Open AccessMultiview spatial compounding using lens-based photoacoustic imaging system
- Open Access
- 1 June 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (6) , 066019-5
Photoacoustic imaging with an acoustic lens detects prostate cancer cells labeled with PSMA-targeting near-infrared dye-conjugates
The clinical management of early stage, organ-confined prostate cancer (PrCa) is challenging. The introduction of serum prostate-specific antigen (PSA) screening in the 1980s led to a spike in the apparent incidence of PrCa, due to the detection of previously underdiagnosed indolent cancers, which grow slowly and do not affect lifespan.1 While PSA screening has declined from its peak, most PrCa is still screen-detected and, therefore, likely to be indolent, requiring no treatment. Unfortunately, there is no reliable technology to identify the rare aggressive cancers among the mass of indolent screen-detected PrCa, which has led to frequent overtreatment by surgery or radiation. A lot of effort has been focused on the development of tissue or serum biomarkers to differentiate indolent from aggressive disease, but this has not yet yielded sensitive and specific clinical tools. Consequently, the current clinical paradigm for screen-detected PrCa is active surveillance2,3 (AS): monitoring by serum PSA testing and serial prostate biopsies to determine the grade (Gleason score) and extent of tumor.
- 1 June 2016
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 21 (6) , 066019-5
Open AccessPhotoacoustic imaging with an acoustic lens detects prostate cancer cells labeled with PSMA-targeting near-infrared dye-conjugates
The clinical management of early stage, organ-confined prostate cancer (PrCa) is challenging. The introduction of serum prostate-specific antigen (PSA) screening in the 1980s led to a spike in the apparent incidence of PrCa, due to the detection of previously underdiagnosed indolent cancers, which grow slowly and do not affect lifespan.1 While PSA screening has declined from its peak, most PrCa is still screen-detected and, therefore, likely to be indolent, requiring no treatment. Unfortunately, there is no reliable technology to identify the rare aggressive cancers among the mass of indolent screen-detected PrCa, which has led to frequent overtreatment by surgery or radiation. A lot of effort has been focused on the development of tissue or serum biomarkers to differentiate indolent from aggressive disease, but this has not yet yielded sensitive and specific clinical tools. Consequently, the current clinical paradigm for screen-detected PrCa is active surveillance2,3 (AS): monitoring by serum PSA testing and serial prostate biopsies to determine the grade (Gleason score) and extent of tumor.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Fabrication of a novel C-scan photoacoustic imaging camera
Our objective is to provide researchers with an inexpensive and fast photoacoustic imaging (PAI) device for exvivo studies. We implement this using an acoustic lens based focusing idea together with photoacoustic technology, resulting in a prototype imaging system. A complete photoacoustic imaging system simulation modeling is presented. The system resolution is evaluated through simulation and experiment. Imaging capability with the prototype system is demonstrated.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Fabrication of a novel C-scan photoacoustic imaging camera
Our objective is to provide researchers with an inexpensive and fast photoacoustic imaging (PAI) device for exvivo studies. We implement this using an acoustic lens based focusing idea together with photoacoustic technology, resulting in a prototype imaging system. A complete photoacoustic imaging system simulation modeling is presented. The system resolution is evaluated through simulation and experiment. Imaging capability with the prototype system is demonstrated.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7968, 79680C-79680C-7
Development of a c-scan photoacoutsic imaging probe for prostate cancer detection
Prostate cancer is the second leading cause of death in American men after lung cancer. The current screening procedures include Digital Rectal Exam (DRE) and Prostate Specific Antigen (PSA) test, along with Transrectal Ultrasound (TRUS). All suffer from low sensitivity and specificity in detecting prostate cancer in early stages. There is a desperate need for a new imaging modality. We are developing a prototype transrectal photoacoustic imaging probe to detect prostate malignancies in vivo that promises high sensitivity and specificity. To generate photoacoustic (PA) signals, the probe utilizes a high energy 1064 nm laser that delivers light pulses onto the prostate at 10Hz with 10ns duration through a fiber optic cable. The designed system will generate focused C-scan planar images using acoustic lens technology. A 5 MHz custom fabricated ultrasound sensor array located in the image plane acquires the focused PA signals, eliminating the need for any synthetic aperture focusing. The lens and sensor array design was optimized towards this objective. For fast acquisition times, a custom built 16 channel simultaneous backend electronics PCB has been developed. It consists of a low-noise variable gain amplifier and a 16 channel ADC. Due to the unavailability of 2d ultrasound arrays, in the current implementation several B-scan (depth-resolved) data is first acquired by scanning a 1d array, which is then processed to reconstruct either 3d volumetric images or several C-scan planar images. Experimental results on excised tissue using a in-vitro prototype of this technology are presented to demonstrate the system capability in terms of resolution and sensitivity.
- 3 March 2011
- Published by SPIE-Intl Soc Optical Eng
- Vol. 7968, 79680C-79680C-7
Development of a c-scan photoacoutsic imaging probe for prostate cancer detection
Prostate cancer is the second leading cause of death in American men after lung cancer. The current screening procedures include Digital Rectal Exam (DRE) and Prostate Specific Antigen (PSA) test, along with Transrectal Ultrasound (TRUS). All suffer from low sensitivity and specificity in detecting prostate cancer in early stages. There is a desperate need for a new imaging modality. We are developing a prototype transrectal photoacoustic imaging probe to detect prostate malignancies in vivo that promises high sensitivity and specificity. To generate photoacoustic (PA) signals, the probe utilizes a high energy 1064 nm laser that delivers light pulses onto the prostate at 10Hz with 10ns duration through a fiber optic cable. The designed system will generate focused C-scan planar images using acoustic lens technology. A 5 MHz custom fabricated ultrasound sensor array located in the image plane acquires the focused PA signals, eliminating the need for any synthetic aperture focusing. The lens and sensor array design was optimized towards this objective. For fast acquisition times, a custom built 16 channel simultaneous backend electronics PCB has been developed. It consists of a low-noise variable gain amplifier and a 16 channel ADC. Due to the unavailability of 2d ultrasound arrays, in the current implementation several B-scan (depth-resolved) data is first acquired by scanning a 1d array, which is then processed to reconstruct either 3d volumetric images or several C-scan planar images. Experimental results on excised tissue using a in-vitro prototype of this technology are presented to demonstrate the system capability in terms of resolution and sensitivity.