Baichuan Jiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Baichuan Jiang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Emad M. Boctor
Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Whiting School of Engineering, Baltimore, Maryland, USA
5 shared publications Keshuai Xu
Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA
3 shared publications- Peter Kazanzides
Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD 21218, USA
3 shared publications - Russell H. Taylor
Department of Computer Science, Johns Hopkins University
3 shared publications Thomas C. Lee
Department of Neuroradiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, USA
3 shared publicationsWenpeng Gao
School of Life Science and Technology, Harbin Institute of Technology, Harbin, 150001, China
3 shared publications
Latest Publications
- Open Access
- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (07) , 076004-19
Automatic photoacoustic monitoring of perinatal brain hypoxia with superior sagittal sinus detection
Perinatal hypoxic-ischemic encephalopathy (HIE) is estimated to affect approximately one to three per 1000 live full-term births and can lead to severe neuropsychological sequelae or death. It was reported that of the affected newborns will develop severe sequelae, including cerebral palsy, mental retardation, epilepsy, or increased hyperactivity, and 15% to 20% will die in the postnatal period.1- 1 July 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (07) , 076004-19
Open AccessAutomatic photoacoustic monitoring of perinatal brain hypoxia with superior sagittal sinus detection
Perinatal hypoxic-ischemic encephalopathy (HIE) is estimated to affect approximately one to three per 1000 live full-term births and can lead to severe neuropsychological sequelae or death. It was reported that of the affected newborns will develop severe sequelae, including cerebral palsy, mental retardation, epilepsy, or increased hyperactivity, and 15% to 20% will die in the postnatal period.1 - 27 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (4) , 966-977
Wearable Mechatronic Ultrasound-Integrated AR Navigation System for Lumbar Puncture Guidance
As one of the most commonly performed spinal interventions in routine clinical practice, lumbar punctures are usually done with only hand palpation and trial-and-error. Failures can prolong procedure time and introduce complications such as cerebrospinal fluid leaks and headaches. Therefore, an effective needle insertion guidance method is desired. In this work, we present a complete lumbar puncture guidance system with the integration of (1) a wearable mechatronic ultrasound imaging device, (2) volume-reconstruction and bone surface estimation algorithms and (3) two alternative augmented reality user interfaces for needle guidance, including a HoloLens-based and a tablet-based solution. We conducted a quantitative evaluation of the end-to-end navigation accuracy, which shows that our system can achieve an overall needle navigation accuracy of 2.83 mm and 2.76 mm for the Tablet-based and the HoloLens-based solutions, respectively. In addition, we conducted a preliminary user study to qualitatively evaluate the effectiveness and ergonomics of our system on lumbar phantoms. The results show that users were able to successfully reach the target in an average of 1.12 and 1.14 needle insertion attempts for Tablet-based and HoloLens-based systems, respectively, exhibiting the potential to reduce the failure rates of lumbar puncture procedures with the proposed lumbar-puncture guidance.
- 27 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 5 (4) , 966-977
Wearable Mechatronic Ultrasound-Integrated AR Navigation System for Lumbar Puncture Guidance
As one of the most commonly performed spinal interventions in routine clinical practice, lumbar punctures are usually done with only hand palpation and trial-and-error. Failures can prolong procedure time and introduce complications such as cerebrospinal fluid leaks and headaches. Therefore, an effective needle insertion guidance method is desired. In this work, we present a complete lumbar puncture guidance system with the integration of (1) a wearable mechatronic ultrasound imaging device, (2) volume-reconstruction and bone surface estimation algorithms and (3) two alternative augmented reality user interfaces for needle guidance, including a HoloLens-based and a tablet-based solution. We conducted a quantitative evaluation of the end-to-end navigation accuracy, which shows that our system can achieve an overall needle navigation accuracy of 2.83 mm and 2.76 mm for the Tablet-based and the HoloLens-based solutions, respectively. In addition, we conducted a preliminary user study to qualitatively evaluate the effectiveness and ergonomics of our system on lumbar phantoms. The results show that users were able to successfully reach the target in an average of 1.12 and 1.14 needle insertion attempts for Tablet-based and HoloLens-based systems, respectively, exhibiting the potential to reduce the failure rates of lumbar puncture procedures with the proposed lumbar-puncture guidance.
- Open Access
Insonification Angle-based Ultrasound Volume Reconstruction for Spine Intervention
Ultrasound-guided spine interventions, such as lumbar-puncture procedures, often suffer from the reduced visibility of key anatomical features such as the inter-spinous process space, due to the complex shape of the self-shadowing vertebra. Therefore, we propose to design a wearable 3D ultrasound device capable of imaging the vertebra from multiple insonification angles to improve the 3D bone surface visualization for interventional guidance. In this work, we aim to equip the imaging platform with a reconstruction algorithm taking advantage of the redundant ultrasound beam angles. Specifically, we try to weight each beam's contribution for the same reconstructed voxel during the reconstruction process based on its incidence angle to the estimated bone surface. To validate our approach, we acquired multi-angle ultrasound image data on a spine phantom with a tracked phased array transducer. The results show that with the proposed method the bone surface contrast can be significantly enhanced, providing clearer visual guidance for the clinician to perform spine intervention.
Open AccessInsonification Angle-based Ultrasound Volume Reconstruction for Spine Intervention
Ultrasound-guided spine interventions, such as lumbar-puncture procedures, often suffer from the reduced visibility of key anatomical features such as the inter-spinous process space, due to the complex shape of the self-shadowing vertebra. Therefore, we propose to design a wearable 3D ultrasound device capable of imaging the vertebra from multiple insonification angles to improve the 3D bone surface visualization for interventional guidance. In this work, we aim to equip the imaging platform with a reconstruction algorithm taking advantage of the redundant ultrasound beam angles. Specifically, we try to weight each beam's contribution for the same reconstructed voxel during the reconstruction process based on its incidence angle to the estimated bone surface. To validate our approach, we acquired multi-angle ultrasound image data on a spine phantom with a tracked phased array transducer. The results show that with the proposed method the bone surface contrast can be significantly enhanced, providing clearer visual guidance for the clinician to perform spine intervention.
- Open Access
Feature-aggregated spatiotemporal spine surface estimation for wearable patch ultrasound volumetric imaging
Clear identification of bone structures is crucial for ultrasound-guided lumbar interventions, but it can be challenging due to the complex shapes of the self-shadowing vertebra anatomy and the extensive background speckle noise from the surrounding soft tissue structures. Therefore, we propose to use a patch-like wearable ultrasound solution to capture the reflective bone surfaces from multiple imaging angles and create 3D bone representations for interventional guidance. In this work, we will present our method for estimating the vertebra bone surfaces by using a spatiotemporal U-Net architecture learning from the B-Mode image and aggregated feature maps of hand-crafted filters. The methods are evaluated on spine phantom image data collected by our proposed miniaturized wearable "patch" ultrasound device, and the results show that a significant improvement on baseline method can be achieved with promising accuracy. Equipped with this surface estimation framework, our wearable ultrasound system can potentially provide intuitive and accurate interventional guidance for clinicians in augmented reality setting.
Open AccessFeature-aggregated spatiotemporal spine surface estimation for wearable patch ultrasound volumetric imaging
Clear identification of bone structures is crucial for ultrasound-guided lumbar interventions, but it can be challenging due to the complex shapes of the self-shadowing vertebra anatomy and the extensive background speckle noise from the surrounding soft tissue structures. Therefore, we propose to use a patch-like wearable ultrasound solution to capture the reflective bone surfaces from multiple imaging angles and create 3D bone representations for interventional guidance. In this work, we will present our method for estimating the vertebra bone surfaces by using a spatiotemporal U-Net architecture learning from the B-Mode image and aggregated feature maps of hand-crafted filters. The methods are evaluated on spine phantom image data collected by our proposed miniaturized wearable "patch" ultrasound device, and the results show that a significant improvement on baseline method can be achieved with promising accuracy. Equipped with this surface estimation framework, our wearable ultrasound system can potentially provide intuitive and accurate interventional guidance for clinicians in augmented reality setting.
- 18 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (3) , 1287-1294
Real-Time Intraoperative Surgical Guidance System in the da Vinci Surgical Robot Based on Transrectal Ultrasound/Photoacoustic Imaging With Photoacoustic Markers: An Ex Vivo Demonstration
This letter introduces the first integrated real-time intraoperative surgical guidance system, in which an endoscope camera of da Vinci surgical robot and a transrectal ultrasound (TRUS) transducer are co-registered using photoacoustic markers that are detected in both fluorescence (FL) and photoacoustic (PA) imaging. The co-registered system enables the TRUS transducer to track the laser spot illuminated by a pulsed-laser-diode attached to the surgical instrument, providing both FL and PA images of the surgical region-of-interest (ROI). As a result, the generated photoacoustic marker is visualized and localized in the da Vinci endoscopic FL images, and the corresponding tracking can be conducted by rotating the TRUS transducer to display the PA image of the marker. A quantitative evaluation revealed that the average registration and tracking errors were 0.84 mm and 1.16°, respectively. This study shows that the co-registered photoacoustic marker tracking can be effectively deployed intraoperatively using TRUS+PA imaging providing functional guidance of the surgical ROI.
- 18 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 8 (3) , 1287-1294
Real-Time Intraoperative Surgical Guidance System in the da Vinci Surgical Robot Based on Transrectal Ultrasound/Photoacoustic Imaging With Photoacoustic Markers: An Ex Vivo Demonstration
This letter introduces the first integrated real-time intraoperative surgical guidance system, in which an endoscope camera of da Vinci surgical robot and a transrectal ultrasound (TRUS) transducer are co-registered using photoacoustic markers that are detected in both fluorescence (FL) and photoacoustic (PA) imaging. The co-registered system enables the TRUS transducer to track the laser spot illuminated by a pulsed-laser-diode attached to the surgical instrument, providing both FL and PA images of the surgical region-of-interest (ROI). As a result, the generated photoacoustic marker is visualized and localized in the da Vinci endoscopic FL images, and the corresponding tracking can be conducted by rotating the TRUS transducer to display the PA image of the marker. A quantitative evaluation revealed that the average registration and tracking errors were 0.84 mm and 1.16°, respectively. This study shows that the co-registered photoacoustic marker tracking can be effectively deployed intraoperatively using TRUS+PA imaging providing functional guidance of the surgical ROI.
- 7 February 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (4) , 573-583
Kalman filter-based EM-optical sensor fusion for needle deflection estimation
In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle’s tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects.
- 7 February 2018
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 13 (4) , 573-583
Kalman filter-based EM-optical sensor fusion for needle deflection estimation
In many clinical procedures such as cryoablation that involves needle insertion, accurate placement of the needle’s tip at the desired target is the major issue for optimizing the treatment and minimizing damage to the neighboring anatomy. However, due to the interaction force between the needle and tissue, considerable error in intraoperative tracking of the needle tip can be observed as needle deflects.
- 3 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10135, 101350U
Real-time MRI-guided needle intervention for cryoablation: a phantom study
MRI-guided needle intervention for cryoablation is a promising way to relieve the pain and treat the cancer. However, the limited size of MRI bore makes it impossible for clinicians to perform the operation in the bore. The patients had to be moved into the bore for scanning to verify the position of the needle’s tip and out for adjusting the needle’s trajectory. Real-time needle tracking and shown in MR images is of importance for clinicians to perform the operation more efficiently. In this paper, we have instrumented the cryotherapy needle with a MRI-safe electromagnetic (EM) sensor and optical sensor to measure the needle’s position and orientation. To overcome the limitation of line-of-sight for optical sensor and the poor dynamic performance of the EM sensor, Kalman filter based data fusion is developed. Further, we developed a navigation system in open-source software, 3D Slicer, to provide accurate visualization of the needle and the surrounding anatomy. Experiment of simulation the needle intervention at the entrance was performed with a realistic spine phantom to quantify the accuracy of the navigation using the retrospective analysis method. Eleven trials of needle insertion were performed independently. The target accuracy with the navigation using only EM sensor, only optical sensor and data fusion are 2.27 ±1.60 mm, 4.11 ± 1.77 mm and 1.91 − 1.10 mm, respectively.
- 3 March 2017
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10135, 101350U
Real-time MRI-guided needle intervention for cryoablation: a phantom study
MRI-guided needle intervention for cryoablation is a promising way to relieve the pain and treat the cancer. However, the limited size of MRI bore makes it impossible for clinicians to perform the operation in the bore. The patients had to be moved into the bore for scanning to verify the position of the needle’s tip and out for adjusting the needle’s trajectory. Real-time needle tracking and shown in MR images is of importance for clinicians to perform the operation more efficiently. In this paper, we have instrumented the cryotherapy needle with a MRI-safe electromagnetic (EM) sensor and optical sensor to measure the needle’s position and orientation. To overcome the limitation of line-of-sight for optical sensor and the poor dynamic performance of the EM sensor, Kalman filter based data fusion is developed. Further, we developed a navigation system in open-source software, 3D Slicer, to provide accurate visualization of the needle and the surrounding anatomy. Experiment of simulation the needle intervention at the entrance was performed with a realistic spine phantom to quantify the accuracy of the navigation using the retrospective analysis method. Eleven trials of needle insertion were performed independently. The target accuracy with the navigation using only EM sensor, only optical sensor and data fusion are 2.27 ±1.60 mm, 4.11 ± 1.77 mm and 1.91 − 1.10 mm, respectively.
- 2 October 2016
- Published by Springer Nature
- p. 457-464
Kalman Filter Based Data Fusion for Needle Deflection Estimation Using Optical-EM Sensor
- 2 October 2016
- Published by Springer Nature
- p. 457-464
Kalman Filter Based Data Fusion for Needle Deflection Estimation Using Optical-EM Sensor