Ravi Chandra Bakaraju
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ravi Chandra Bakaraju has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Klaus Ehrmann
Brien Holden Vision Institute, Sydney, NSW, Australia; School of Optometry and Vision Sciences, UNSW, Sydney, NSW, Australia
11 shared publicationsVarghese Thomas
Brien Holden Vision Institute, Sydney, New South Wales, Australia
11 shared publicationsCathleen Fedtke
Brien Holden Vision Institute, Sydney, NSW, Australia; School of Optometry and Vision Sciences, UNSW, Sydney, NSW, Australia
8 shared publications- Daniel Tilia
University of New South Wales
6 shared publications Arthur Ho
Brien Holden Vision Institute, Sydney, Australia; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia
5 shared publicationsJennie Diec
Brien Holden Vision Institute, Sydney, New South Wales, Australia
5 shared publications
Latest Publications
- Open Access
- 1 October 2021
- Published by Wiley in Optometry and Vision Science
- Vol. 98 (10) , 1160-1168
Associations between Binocular Vision Disorders and Contact Lens Dissatisfaction
SIGNIFICANCE: These data demonstrate that binocular vision disorders (BVDs) contribute to contact lens (CL) dissatisfaction independently of CL discomfort (CLD) in myopic, pre‐presbyopic, adult, single‐vision CL wearers. PURPOSE: This study aimed to determine whether BVDs contribute to CL dissatisfaction and whether this contribution is independent of CLD. METHODS: Participants attended one clinical visit while wearing their habitual CLs. Symptoms from CLD and BVDs were measured with the Contact Lens Dry Eye Questionnaire‐8 (CLDEQ‐8) and Convergence Insufficiency Syndrome Survey (CISS), respectively. A comprehensive binocular vision (BV) assessment was performed. The Ocular Surface Disease Index (OSDI) was used to measure CL dissatisfaction from CLD and BVDs based on reported correlations between the CLDEQ‐8 and the CISS with the OSDI. Participants were categorized according to their CL comfort status (CLD [≥12 on CLDEQ‐8] or non‐CLD [P <. 001) and CISS (18.7 ± 7.7 vs. 11.9 ± 5.9, P =. 001), but not the CLDEQ‐8 ( P =. 25). Those categorized as having CLD scored higher than did those categorized as having non‐CLD for the OSDI (19.0 ± 12.3 vs. 9.3 ± 5.9, P =. 003) and CISS (16.1 ± 6.8 vs. 11.0 ± 6.2, P =. 001). There were no significant interactions between BV status and CL comfort status for any questionnaire ( P >. 08). CONCLUSIONS: Higher scores for OSDI in those with CLD or BVD indicate that both conditions contribute to CL dissatisfaction. Higher scores for the CISS in those with CLD suggest a degree of overlap for some BVD symptoms. Nonsignificant differences between BVD and non‐BVD for the CLDEQ‐8 suggest that BVDs contribute to CL dissatisfaction independently of CLD.
- 1 October 2021
- Published by Wiley in Optometry and Vision Science
- Vol. 98 (10) , 1160-1168
Open AccessAssociations between Binocular Vision Disorders and Contact Lens Dissatisfaction
SIGNIFICANCE: These data demonstrate that binocular vision disorders (BVDs) contribute to contact lens (CL) dissatisfaction independently of CL discomfort (CLD) in myopic, pre‐presbyopic, adult, single‐vision CL wearers. PURPOSE: This study aimed to determine whether BVDs contribute to CL dissatisfaction and whether this contribution is independent of CLD. METHODS: Participants attended one clinical visit while wearing their habitual CLs. Symptoms from CLD and BVDs were measured with the Contact Lens Dry Eye Questionnaire‐8 (CLDEQ‐8) and Convergence Insufficiency Syndrome Survey (CISS), respectively. A comprehensive binocular vision (BV) assessment was performed. The Ocular Surface Disease Index (OSDI) was used to measure CL dissatisfaction from CLD and BVDs based on reported correlations between the CLDEQ‐8 and the CISS with the OSDI. Participants were categorized according to their CL comfort status (CLD [≥12 on CLDEQ‐8] or non‐CLD [P <. 001) and CISS (18.7 ± 7.7 vs. 11.9 ± 5.9, P =. 001), but not the CLDEQ‐8 ( P =. 25). Those categorized as having CLD scored higher than did those categorized as having non‐CLD for the OSDI (19.0 ± 12.3 vs. 9.3 ± 5.9, P =. 003) and CISS (16.1 ± 6.8 vs. 11.0 ± 6.2, P =. 001). There were no significant interactions between BV status and CL comfort status for any questionnaire ( P >. 08). CONCLUSIONS: Higher scores for OSDI in those with CLD or BVD indicate that both conditions contribute to CL dissatisfaction. Higher scores for the CISS in those with CLD suggest a degree of overlap for some BVD symptoms. Nonsignificant differences between BVD and non‐BVD for the CLDEQ‐8 suggest that BVDs contribute to CL dissatisfaction independently of CLD.
- Open Access
- 1 January 2020
- Published by Elsevier in Journal of Optometry
- Vol. 13 (1) , 15-28
Peripheral refraction and spherical aberration profiles with single vision, bifocal and multifocal soft contact lenses
- 1 January 2020
- Published by Elsevier in Journal of Optometry
- Vol. 13 (1) , 15-28
Open AccessPeripheral refraction and spherical aberration profiles with single vision, bifocal and multifocal soft contact lenses
- 1 April 2019
- Published by Wiley in Optometry and Vision Science
- Vol. 96 (4) , 283-290
The Relationship between Visual Acuity, Subjective Vision, and Willingness to Purchase Simultaneous‐image Contact Lenses
Supplemental digital content is available in the text. SIGNIFICANCE: This study reports that subjective vision ratings are better indicators of willingness to purchase simultaneous‐image contact lenses than visual acuities and are more valuable in evaluating contact lens performance. PURPOSE: The purpose of this study was to investigate the relationship between visual acuities, subjective vision ratings, and willingness to purchase simultaneous‐image contact lenses in presbyopes. METHODS: A retrospective analysis of visual acuities, subjective vision ratings, and willingness to purchase from final visits of two masked, crossover clinical trials of nine prototype and four commercially available simultaneous‐image contact lenses in 141 presbyopes was performed. Pearson correlation and area under the receiver operating characteristic curve determined correlations between variables. RESULTS: Most subjective vision ratings were weakly correlated ( r < 0.3) with visual acuity at all distances and illumination. Moderate correlations ( r , 95% confidence intervals) were found between overall vision satisfaction ratings with visual acuity at 40 (−0.34, −0.28 to −0.40) and 50 cm (−0.33, −0.27 to −0.39), near‐vision ratings (daytime) with visual acuity at 40 (−0.48, −0.43 to −0.53) and 50 cm (−0.46; −0.41 to −0.51), and intermediate‐vision ratings (daytime) with visual acuity at 40 (−0.39, −0.33 to −0.45) and 50 cm (−0.41, −0.35 to −0.46). Highest discrimination for willingness to purchase was with overall vision satisfaction (area under curve, 0.93) and vision stability (daytime; area under curve, 0.77). Ratings from 4 to 9 for vision satisfaction showed a linear increase in willingness to purchase: a 1‐unit increase in vision satisfaction increased willingness to purchase by 20%. Ratings lower than 4 had 0% willingness to purchase. Other subjective ratings showed similar relationships, albeit only 10 to 15% increase in willingness to purchase per unit increase for ratings higher than 4. CONCLUSIONS: Subjective vision ratings are a better indicator of simultaneous‐image contact lens performance than visual acuity. Overall vision satisfaction and vision stability are key predictors of willingness to purchase. Subjective vision ratings should be used to evaluate performance rather than visual acuity alone.
- 1 April 2019
- Published by Wiley in Optometry and Vision Science
- Vol. 96 (4) , 283-290
The Relationship between Visual Acuity, Subjective Vision, and Willingness to Purchase Simultaneous‐image Contact Lenses
Supplemental digital content is available in the text. SIGNIFICANCE: This study reports that subjective vision ratings are better indicators of willingness to purchase simultaneous‐image contact lenses than visual acuities and are more valuable in evaluating contact lens performance. PURPOSE: The purpose of this study was to investigate the relationship between visual acuities, subjective vision ratings, and willingness to purchase simultaneous‐image contact lenses in presbyopes. METHODS: A retrospective analysis of visual acuities, subjective vision ratings, and willingness to purchase from final visits of two masked, crossover clinical trials of nine prototype and four commercially available simultaneous‐image contact lenses in 141 presbyopes was performed. Pearson correlation and area under the receiver operating characteristic curve determined correlations between variables. RESULTS: Most subjective vision ratings were weakly correlated ( r < 0.3) with visual acuity at all distances and illumination. Moderate correlations ( r , 95% confidence intervals) were found between overall vision satisfaction ratings with visual acuity at 40 (−0.34, −0.28 to −0.40) and 50 cm (−0.33, −0.27 to −0.39), near‐vision ratings (daytime) with visual acuity at 40 (−0.48, −0.43 to −0.53) and 50 cm (−0.46; −0.41 to −0.51), and intermediate‐vision ratings (daytime) with visual acuity at 40 (−0.39, −0.33 to −0.45) and 50 cm (−0.41, −0.35 to −0.46). Highest discrimination for willingness to purchase was with overall vision satisfaction (area under curve, 0.93) and vision stability (daytime; area under curve, 0.77). Ratings from 4 to 9 for vision satisfaction showed a linear increase in willingness to purchase: a 1‐unit increase in vision satisfaction increased willingness to purchase by 20%. Ratings lower than 4 had 0% willingness to purchase. Other subjective ratings showed similar relationships, albeit only 10 to 15% increase in willingness to purchase per unit increase for ratings higher than 4. CONCLUSIONS: Subjective vision ratings are a better indicator of simultaneous‐image contact lens performance than visual acuity. Overall vision satisfaction and vision stability are key predictors of willingness to purchase. Subjective vision ratings should be used to evaluate performance rather than visual acuity alone.
- 1 December 2018
- Published by Wiley in Optometry and Vision Science
- Vol. 95 (12) , 1096-1104
Visual Performance of Daily‐disposable Multifocal Soft Contact Lenses: A Randomized, Double‐blind Clinical Trial
SIGNIFICANCE: The present study highlights the differences between modern daily‐disposable multifocal soft contact lenses to assist eye care practitioners in fitting presbyopic contact lens wearers. PURPOSE: The purpose of this study was to compare visual performance of three daily‐disposable multifocal contact lenses. METHODS: Presbyopes (n = 72) wore 1‐Day Acuvue Moist Multifocal, BioTrue ONEday for Presbyopia, and Dailies AquaComfort Plus Multifocal for 1 week in a prospective, randomized, double‐blind, crossover clinical trial. After 1 week, high‐ and low‐contrast visual acuities (HCVA, LCVA) were measured between 6 m and 40 cm and stereopsis at 40 cm. Subjective performance was assessed with 1‐ to 10‐point rating scales for clarity, ghosting, driving vision, vision stability, ease of focusing, overall vision satisfaction, and ocular comfort. Willingness to purchase was reported with categorical responses. Linear mixed models and χ 2 tests were used for analysis, and level of significance was set at 5%. RESULTS: BioTrue provided better HCVA and LCVA at distance than did Acuvue Moist ( P ≤. 03). Subjectively, Acuvue Moist was rated lowest for distance clarity, distance ghosting, and driving vision ( P ≤. 05). Acuvue Moist provided better HCVA at 70 to 40 cm and LCVA at 1 m to 40 cm than did BioTrue ( P ≤. 01) and better LCVA at 1 m to 50 cm than did AquaComfort Plus ( P ≤. 02). AquaComfort Plus also provided better HCVA and LCVA at 50 and 40 cm than did BioTrue ( P ≤. 03). Acuvue Moist provided better stereopsis than did BioTrue ( P =. 02). Subjectively, BioTrue was rated lowest for near clarity ( P ≤. 007) and lower than Acuvue Moist for intermediate clarity and near ghosting ( P ≤. 04). No other differences were found between lenses ( P >. 05). CONCLUSIONS: BioTrue had better distance performance compared with near, whereas Acuvue Moist performed conversely. AquaComfort Plus performed reasonably overall.
- 1 December 2018
- Published by Wiley in Optometry and Vision Science
- Vol. 95 (12) , 1096-1104
Visual Performance of Daily‐disposable Multifocal Soft Contact Lenses: A Randomized, Double‐blind Clinical Trial
SIGNIFICANCE: The present study highlights the differences between modern daily‐disposable multifocal soft contact lenses to assist eye care practitioners in fitting presbyopic contact lens wearers. PURPOSE: The purpose of this study was to compare visual performance of three daily‐disposable multifocal contact lenses. METHODS: Presbyopes (n = 72) wore 1‐Day Acuvue Moist Multifocal, BioTrue ONEday for Presbyopia, and Dailies AquaComfort Plus Multifocal for 1 week in a prospective, randomized, double‐blind, crossover clinical trial. After 1 week, high‐ and low‐contrast visual acuities (HCVA, LCVA) were measured between 6 m and 40 cm and stereopsis at 40 cm. Subjective performance was assessed with 1‐ to 10‐point rating scales for clarity, ghosting, driving vision, vision stability, ease of focusing, overall vision satisfaction, and ocular comfort. Willingness to purchase was reported with categorical responses. Linear mixed models and χ 2 tests were used for analysis, and level of significance was set at 5%. RESULTS: BioTrue provided better HCVA and LCVA at distance than did Acuvue Moist ( P ≤. 03). Subjectively, Acuvue Moist was rated lowest for distance clarity, distance ghosting, and driving vision ( P ≤. 05). Acuvue Moist provided better HCVA at 70 to 40 cm and LCVA at 1 m to 40 cm than did BioTrue ( P ≤. 01) and better LCVA at 1 m to 50 cm than did AquaComfort Plus ( P ≤. 02). AquaComfort Plus also provided better HCVA and LCVA at 50 and 40 cm than did BioTrue ( P ≤. 03). Acuvue Moist provided better stereopsis than did BioTrue ( P =. 02). Subjectively, BioTrue was rated lowest for near clarity ( P ≤. 007) and lower than Acuvue Moist for intermediate clarity and near ghosting ( P ≤. 04). No other differences were found between lenses ( P >. 05). CONCLUSIONS: BioTrue had better distance performance compared with near, whereas Acuvue Moist performed conversely. AquaComfort Plus performed reasonably overall.
- Open Access
- 1 July 2018
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 10, 75-86
Visual performance of myopia control soft contact lenses in non-presbyopic myopes
Purpose: To compare the visual performance of soft contact lenses reported to reduce myopia progression. Methods: In a double-blind, randomized, crossover trial, 30 non-presbyopic myopes wore MiSight™, center-distance Proclear® Multifocal (+2.00 D add), and two prototype lenses for 1 week each. High- and low-contrast visual acuities at 6 m, and 70 and 40 cm; stereopsis at 40 cm; accommodative facility at 33 cm; and horizontal phoria at 3 m and 33 cm were measured after 1 week. Subjective performance was assessed on a numeric rating scale for vision clarity, lack of ghosting, vision stability, haloes, overall vision satisfaction, and ocular comfort. Frequency of eye-strain symptoms and willingness to purchase lenses were also reported with categorical responses. Participants reported wearing times (total and visually acceptable). Linear mixed models and chi-square tests were employed in analysis with level of significance set at 5%. Theoretical optical performance of all lenses was assessed with schematic myopic model eyes (−1.00, −3.00, and −6.00 D) by comparing the slope of the edge spread function (ESF), an indicator for optical performance/resolution and the blur patch size of the line spread function, an indicator for contrast, between the lenses. Results: Proclear Multifocal and MiSight provided the best distance acuities. However, the prototype lenses were rated significantly higher for many subjective variables, and there were no subjective variables where commercial lenses were rated significantly higher than the prototypes. Theoretical optical performance showed steeper slopes of the ESF and greater blur patch sizes of the LSP with commercial lenses, supporting the clinical findings of better visual acuities but reduced subjective performance. Participants wore prototypes longer and reported their vision acceptable for longer each day compared to MiSight. Both prototypes had the highest willingness-to-purchase rate. Conclusions: The prototypes were better tolerated by myopes compared to the commercial soft contact lenses currently used for slowing myopia progression.
- 1 July 2018
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 10, 75-86
Open AccessVisual performance of myopia control soft contact lenses in non-presbyopic myopes
Purpose: To compare the visual performance of soft contact lenses reported to reduce myopia progression. Methods: In a double-blind, randomized, crossover trial, 30 non-presbyopic myopes wore MiSight™, center-distance Proclear® Multifocal (+2.00 D add), and two prototype lenses for 1 week each. High- and low-contrast visual acuities at 6 m, and 70 and 40 cm; stereopsis at 40 cm; accommodative facility at 33 cm; and horizontal phoria at 3 m and 33 cm were measured after 1 week. Subjective performance was assessed on a numeric rating scale for vision clarity, lack of ghosting, vision stability, haloes, overall vision satisfaction, and ocular comfort. Frequency of eye-strain symptoms and willingness to purchase lenses were also reported with categorical responses. Participants reported wearing times (total and visually acceptable). Linear mixed models and chi-square tests were employed in analysis with level of significance set at 5%. Theoretical optical performance of all lenses was assessed with schematic myopic model eyes (−1.00, −3.00, and −6.00 D) by comparing the slope of the edge spread function (ESF), an indicator for optical performance/resolution and the blur patch size of the line spread function, an indicator for contrast, between the lenses. Results: Proclear Multifocal and MiSight provided the best distance acuities. However, the prototype lenses were rated significantly higher for many subjective variables, and there were no subjective variables where commercial lenses were rated significantly higher than the prototypes. Theoretical optical performance showed steeper slopes of the ESF and greater blur patch sizes of the LSP with commercial lenses, supporting the clinical findings of better visual acuities but reduced subjective performance. Participants wore prototypes longer and reported their vision acceptable for longer each day compared to MiSight. Both prototypes had the highest willingness-to-purchase rate. Conclusions: The prototypes were better tolerated by myopes compared to the commercial soft contact lenses currently used for slowing myopia progression.
- 1 June 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41, S22-S23
Visual performance with commercial soft multifocal contact lenses
- 1 June 2018
- Published by Elsevier in Contact Lens and Anterior Eye
- Vol. 41, S22-S23
Visual performance with commercial soft multifocal contact lenses
- Open Access
- 1 January 2018
- Published by Elsevier in Journal of Optometry
- Vol. 11 (1) , 10-20
Extended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics
- 1 January 2018
- Published by Elsevier in Journal of Optometry
- Vol. 11 (1) , 10-20
Open AccessExtended depth of focus contact lenses vs. two commercial multifocals: Part 1. Optical performance evaluation via computed through-focus retinal image quality metrics
- Open Access
- 1 January 2018
- Published by Elsevier in Journal of Optometry
- Vol. 11 (1) , 21-32
Extended depth of focus contact lenses vs. two commercial multifocals: Part 2. Visual performance after 1 week of lens wear
- 1 January 2018
- Published by Elsevier in Journal of Optometry
- Vol. 11 (1) , 21-32
Open AccessExtended depth of focus contact lenses vs. two commercial multifocals: Part 2. Visual performance after 1 week of lens wear
- Open Access
- 1 January 2018
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 10, 9-17
Effects of relative negative spherical aberration in single vision contact lens visual performance
Objective: The study aimed to compare the visual performance of contact lenses with and without negative spherical aberration (SA) over 5 days of wear. Methods: At baseline, 32 myopic participants (aged 18–33 years) were fitted in a randomized order with two lenses (test lens with minimal or no SA and 1-Day Acuvue Moist designed with negative SA) for 5 days (minimum 6 hours wear/day). Participants returned for a follow-up visit. This consisted of on-axis SA measurements; high- and low-contrast visual acuities at 6 m; high-contrast acuities at 70 and 40 cm; low-illumination, low-contrast acuity at 6 m; stereopsis at 40 cm; horizontal phorias at 3 m and 33 cm; and ±2.00 D monocular accommodative facility at 33 cm. Participants also rated (1–10 scale) vision quality (clarity and lack of ghosting for distance, intermediate, near, driving vision and vision stability during day- and night-time), overall vision satisfaction, ocular comfort, and willingness to purchase (yes/no response). Results: 1-Day Acuvue Moist induced significantly (p0.05) in acuity, binocular vision, and all subjective metrics except vision stability between lenses where the test lens was rated to provide more stable vision (p Conclusion: Contrary to expectations, incorporating negative SA in single vision soft contact lenses did not improve visual performance in non-presbyopic adult myopes.
- 1 January 2018
- Published by Taylor & Francis in Clinical Optometry
- Vol. ume 10, 9-17
Open AccessEffects of relative negative spherical aberration in single vision contact lens visual performance
Objective: The study aimed to compare the visual performance of contact lenses with and without negative spherical aberration (SA) over 5 days of wear. Methods: At baseline, 32 myopic participants (aged 18–33 years) were fitted in a randomized order with two lenses (test lens with minimal or no SA and 1-Day Acuvue Moist designed with negative SA) for 5 days (minimum 6 hours wear/day). Participants returned for a follow-up visit. This consisted of on-axis SA measurements; high- and low-contrast visual acuities at 6 m; high-contrast acuities at 70 and 40 cm; low-illumination, low-contrast acuity at 6 m; stereopsis at 40 cm; horizontal phorias at 3 m and 33 cm; and ±2.00 D monocular accommodative facility at 33 cm. Participants also rated (1–10 scale) vision quality (clarity and lack of ghosting for distance, intermediate, near, driving vision and vision stability during day- and night-time), overall vision satisfaction, ocular comfort, and willingness to purchase (yes/no response). Results: 1-Day Acuvue Moist induced significantly (p0.05) in acuity, binocular vision, and all subjective metrics except vision stability between lenses where the test lens was rated to provide more stable vision (p Conclusion: Contrary to expectations, incorporating negative SA in single vision soft contact lenses did not improve visual performance in non-presbyopic adult myopes.
- Open Access
- 1 January 2017
- Published by Elsevier in Journal of Optometry
- Vol. 10 (1) , 14-25
Short-term comparison between extended depth-of-focus prototype contact lenses and a commercially-available center-near multifocal
- 1 January 2017
- Published by Elsevier in Journal of Optometry
- Vol. 10 (1) , 14-25
Open AccessShort-term comparison between extended depth-of-focus prototype contact lenses and a commercially-available center-near multifocal