Chingis Kharmyssov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chingis Kharmyssov has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Zhandos N. Utegulov
Department of Physics, School of Sciences and Humanities, Nazarbayev University, Astana 010000, Kazakhstan
3 shared publications - Abduzhappar Gaipov
Department of Medicine, School of Medicine, Nazarbayev University, Astana, Kazakhstan
1 shared publication - Abhishek Jain
Department of Biomedical Engineering, College of Engineering, Texas A&M University, College Station, USA
1 shared publication - Ankit Kumar
Department of Biomedical Engineering, Texas A&M University 1 , College Station, Texas 77840
1 shared publication - Brian Sanders
Department of Physics and Astronomy, Texas A&M University 2 , College Station, Texas 77840
1 shared publication - Evren Oktem
Department of Biomedical Engineering, Texas A&M University 1 , College Station, Texas 77840
1 shared publication
Latest Publications
- 2 November 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (18)
Microfluidic Brillouin platform for frequency-resolved mechanics of complex fluids
We introduce an integrated microfluidic platform that combines pressure-flow rheology with depth-resolved Brillouin microspectroscopy to investigate complex fluids in extensive frequency ranges. Apparent viscosity is measured via calibrated pressure-flow in a rectangular polydimethylsiloxane microchannel, while GHz-frequency Brillouin spectroscopy probes longitudinal mechanics under identical steady-flow conditions. Using semi-dilute methylcellulose solutions in a cell-culture medium as a model, we reveal mild shear-thinning behavior, whereas the Brillouin frequency shift and linewidth values remain constant throughout the flow rate range, mainly influenced by polymer concentration. This confirms the decoupling between steady-shear and GHz-frequency acoustic responses observed previously. The platform offers a compact, calibrated approach for frequency-resolved mechanical analysis of flowing soft materials and perfused media.
- 2 November 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 129 (18)
Microfluidic Brillouin platform for frequency-resolved mechanics of complex fluids
We introduce an integrated microfluidic platform that combines pressure-flow rheology with depth-resolved Brillouin microspectroscopy to investigate complex fluids in extensive frequency ranges. Apparent viscosity is measured via calibrated pressure-flow in a rectangular polydimethylsiloxane microchannel, while GHz-frequency Brillouin spectroscopy probes longitudinal mechanics under identical steady-flow conditions. Using semi-dilute methylcellulose solutions in a cell-culture medium as a model, we reveal mild shear-thinning behavior, whereas the Brillouin frequency shift and linewidth values remain constant throughout the flow rate range, mainly influenced by polymer concentration. This confirms the decoupling between steady-shear and GHz-frequency acoustic responses observed previously. The platform offers a compact, calibrated approach for frequency-resolved mechanical analysis of flowing soft materials and perfused media.
- Open Access
- 30 July 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (8) , 371
Brillouin Biosensing of Viscoelasticity across Phase Transitions in Ovine Cornea
Noninvasive in situ monitoring of viscoelastic characteristics of corneal tissue at elevated temperatures is pivotal for mechanical property-informed refractive surgery techniques, including thermokeratoplasty and photorefractive keratectomy, requiring precise thermal modifications of the corneal structure during these surgical procedures. This study harnesses Brillouin light scattering spectroscopy as a biosensing platform to noninvasively probe the viscoelastic properties of ovine corneas across a temperature range of 25–64 °C. By submerging the tissue samples in silicone oil, consistent hydration and immiscibility are maintained, allowing for their accurate sensing of temperature-dependent mechanical behaviors. We identify significant phase transitions in the corneal tissue, particularly beyond 40 °C, likely due to collagen unfolding, marking the beginning of thermal destabilization. A subsequent transition, observed beyond 60 °C, correlates with collagen denaturation. These phase transformations highlight the cornea’s sensitivity to both physiologically reversible and irreversible viscoelastic changes induced by mild to high temperatures. Our findings underscore the potential of the Brillouin biosensing technique for real-time diagnostics of corneal biomechanics during refractive surgeries to attain optimized therapeutic outcomes.
- 30 July 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (8) , 371
Open AccessBrillouin Biosensing of Viscoelasticity across Phase Transitions in Ovine Cornea
Noninvasive in situ monitoring of viscoelastic characteristics of corneal tissue at elevated temperatures is pivotal for mechanical property-informed refractive surgery techniques, including thermokeratoplasty and photorefractive keratectomy, requiring precise thermal modifications of the corneal structure during these surgical procedures. This study harnesses Brillouin light scattering spectroscopy as a biosensing platform to noninvasively probe the viscoelastic properties of ovine corneas across a temperature range of 25–64 °C. By submerging the tissue samples in silicone oil, consistent hydration and immiscibility are maintained, allowing for their accurate sensing of temperature-dependent mechanical behaviors. We identify significant phase transitions in the corneal tissue, particularly beyond 40 °C, likely due to collagen unfolding, marking the beginning of thermal destabilization. A subsequent transition, observed beyond 60 °C, correlates with collagen denaturation. These phase transformations highlight the cornea’s sensitivity to both physiologically reversible and irreversible viscoelastic changes induced by mild to high temperatures. Our findings underscore the potential of the Brillouin biosensing technique for real-time diagnostics of corneal biomechanics during refractive surgeries to attain optimized therapeutic outcomes.
- Open Access
- 27 May 2024
- Published by MDPI AG in Preprints.org
Brillouin Biosensing of Viscoelasticity Across Phase Transitions in Ovine Cornea
Noninvasive in-situ monitoring of viscoelastic characteristics of corneal tissue at elevated temperatures are pivotal for mechanical property-informed refractive surgery techniques, including thermokeratoplasty and photorefractive keratectomy, requiring precise thermal modifications of the corneal structure during these surgical procedures. This study harnesses Brillouin light scattering spectroscopy as a biosensing platform to non-invasively probe the viscoelastic properties of ovine corneas across a temperature range of 25 - 70°C. By submerging the tissue samples in silicone oil, consistent hydration is maintained, allowing for their accurate sensing of temperature-dependent mechanical behaviors. We identify significant phase transitions in the corneal tissue, particularly beyond 40°C, likely due to collagen unfolding, marking the beginning of thermal destabilization. A subsequent transition, observed beyond 60°C, correlates with collagen denaturation. These phase transformations highlight the cornea's sensitivity to both physiologically reversible and irreversible viscoelastic changes induced by mild to high temperatures. Our findings underscore the potential of Brillouin biosensing technique for real-time diagnostics of corneal biomechanics during refractive surgeries to attain optimized therapeutic outcomes.
- 27 May 2024
- Published by MDPI AG in Preprints.org
Open AccessBrillouin Biosensing of Viscoelasticity Across Phase Transitions in Ovine Cornea
Noninvasive in-situ monitoring of viscoelastic characteristics of corneal tissue at elevated temperatures are pivotal for mechanical property-informed refractive surgery techniques, including thermokeratoplasty and photorefractive keratectomy, requiring precise thermal modifications of the corneal structure during these surgical procedures. This study harnesses Brillouin light scattering spectroscopy as a biosensing platform to non-invasively probe the viscoelastic properties of ovine corneas across a temperature range of 25 - 70°C. By submerging the tissue samples in silicone oil, consistent hydration is maintained, allowing for their accurate sensing of temperature-dependent mechanical behaviors. We identify significant phase transitions in the corneal tissue, particularly beyond 40°C, likely due to collagen unfolding, marking the beginning of thermal destabilization. A subsequent transition, observed beyond 60°C, correlates with collagen denaturation. These phase transformations highlight the cornea's sensitivity to both physiologically reversible and irreversible viscoelastic changes induced by mild to high temperatures. Our findings underscore the potential of Brillouin biosensing technique for real-time diagnostics of corneal biomechanics during refractive surgeries to attain optimized therapeutic outcomes.
- Open Access
Mechano-Chemistry across Phase Transitions in Heated Albumin Protein Solutions
The presence of certain proteins in biofluids such as synovial fluid, blood plasma, and saliva gives these fluids non-Newtonian viscoelastic properties. The amount of these protein macromolecules in biofluids is an important biomarker for the diagnosis of various health conditions, including Alzheimer’s disease, cardiovascular disorders, and joint quality. However, existing technologies for measuring the behavior of macromolecules in biofluids have limitations, such as long turnaround times, complex protocols, and insufficient sensitivity. To address these issues, we propose non-contact, optical Brillouin and Raman spectroscopy to assess the viscoelasticity and chemistry of non-Newtonian solutions, respectively, at different temperatures in several minutes. In this work, bovine and human serum albumin solution-based biopolymers were studied to obtain both their collective dynamics and molecular chemical evolution across heat-driven phase transitions at various protein concentrations. The observed phase transitions at elevated temperatures could be fully delayed in heated biopolymers by appropriately raising the level of protein concentration. The non-contact optical monitoring of viscoelastic and chemical property evolution could represent novel potential mechano-chemical biomarkers for disease diagnosis and subsequent treatment applications, including hyperthermia.
Open AccessMechano-Chemistry across Phase Transitions in Heated Albumin Protein Solutions
The presence of certain proteins in biofluids such as synovial fluid, blood plasma, and saliva gives these fluids non-Newtonian viscoelastic properties. The amount of these protein macromolecules in biofluids is an important biomarker for the diagnosis of various health conditions, including Alzheimer’s disease, cardiovascular disorders, and joint quality. However, existing technologies for measuring the behavior of macromolecules in biofluids have limitations, such as long turnaround times, complex protocols, and insufficient sensitivity. To address these issues, we propose non-contact, optical Brillouin and Raman spectroscopy to assess the viscoelasticity and chemistry of non-Newtonian solutions, respectively, at different temperatures in several minutes. In this work, bovine and human serum albumin solution-based biopolymers were studied to obtain both their collective dynamics and molecular chemical evolution across heat-driven phase transitions at various protein concentrations. The observed phase transitions at elevated temperatures could be fully delayed in heated biopolymers by appropriately raising the level of protein concentration. The non-contact optical monitoring of viscoelastic and chemical property evolution could represent novel potential mechano-chemical biomarkers for disease diagnosis and subsequent treatment applications, including hyperthermia.
- 26 April 2019
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (7) , 1591-1603
Optic nerve head damage relation to intracranial pressure and corneal properties of eye in glaucoma risk assessment
This work presents results from numerical simulations of optic nerve head’s (ONH) biomechanical behavior during exposure to elevated intraocular (IOP) and/or intracranial pressure (ICP) for ocular hypertension conditions. At the same time, a range of geometric and material properties of the eye structure and their interrelation with elevated IOP and ICP values are investigated. These simulations are performed on a generic model of the eye, which allows parametrical modification of geometric and material properties. Our main interest is in measuring ONH’s potential damage in ocular hypertension due to intracranial pressure. Simulation results indicate a significant role of ICP in post-laminar neural tissue failure and a possible role of central corneal thickness (CCT) and scleral modulus in clinical assessment and treatment of patients with ocular hypertension (OHT). Specifically, CCT was found to affect ONH at early stages of damage in ocular hypertension conditions, and high scleral modulus seems to result in reduced shear failure in lamina cribrosa in a similar OHT state. These findings suggest that CCT could be a risk factor for glaucoma in OHT patients at initial stage along with cornea stiffness.
- 26 April 2019
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 57 (7) , 1591-1603
Optic nerve head damage relation to intracranial pressure and corneal properties of eye in glaucoma risk assessment
This work presents results from numerical simulations of optic nerve head’s (ONH) biomechanical behavior during exposure to elevated intraocular (IOP) and/or intracranial pressure (ICP) for ocular hypertension conditions. At the same time, a range of geometric and material properties of the eye structure and their interrelation with elevated IOP and ICP values are investigated. These simulations are performed on a generic model of the eye, which allows parametrical modification of geometric and material properties. Our main interest is in measuring ONH’s potential damage in ocular hypertension due to intracranial pressure. Simulation results indicate a significant role of ICP in post-laminar neural tissue failure and a possible role of central corneal thickness (CCT) and scleral modulus in clinical assessment and treatment of patients with ocular hypertension (OHT). Specifically, CCT was found to affect ONH at early stages of damage in ocular hypertension conditions, and high scleral modulus seems to result in reduced shear failure in lamina cribrosa in a similar OHT state. These findings suggest that CCT could be a risk factor for glaucoma in OHT patients at initial stage along with cornea stiffness.
- 1 January 2019
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 17 (1)
Automated segmentation of optical coherence tomography images
- 1 January 2019
- Published by Shanghai Institute of Optics and Fine Mechanics in Chinese Optics Letters
- Vol. 17 (1)
Automated segmentation of optical coherence tomography images