RBRichard A. Bone

Richard A. Bone

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Richard A. Bone has a total of 18 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Efficacy of Commercially Available Nutritional Supplements: Analysis of Serum Uptake, Macular Pigment Optical Density and Visual Functional Response

    by Richard A. Bone, Pinakin Gunvant Davey, Betzabe O. Roman, David W. Evans

    Purpose: To compare the change in serum carotenoids, macular pigment optical density (MPOD) and visual function with the intake of two commercially available nutritional supplements. Methods: Participants were given a 24-week supply of a lipid-based micronized liquid medical food, Lumega-Z™ (LM), containing 28 mg of the macular carotenoids lutein (L), zeaxanthin (Z) and meso-zeaxanthin (MZ), or given PreserVision™ AREDS 2 Formula (gel-caps; PV) containing 12 mg of the macular carotenoids L and Z, but no reported MZ. Serum levels of L, Z and MZ were obtained at baseline and after 12 weeks. Macular pigment optical densities (MPOD) and visual function were assessed at baseline and after 24 weeks. Results: Average blood serum concentrations of L, Z and MZ in the two groups at baseline were similar. The increases in L, Z and MZ were 0.434, 0.063 and 0.086 µmol/L vs. 0.100, 0.043 and 0.001 µmol/L, respectively, in the LM vs. PV group. From baseline to week 24, average MPOD in the LM-group increased by 0.064 from 0.418 to 0.482, whereas in the PV-group, it was essentially unchanged (0.461 to 0.459;). Although log-contrast sensitivity was improved in all groups under three conditions (photopic, mesopic and mesopic with glare), the change in log-contrast sensitivity was not statistically significant. Conclusion: Despite only a 2.3-fold higher carotenoid concentration than PV, LM supplementation provides approximately 3–4-fold higher absorption, which leads to a significant elevation of MPOD levels.


  • Open Access

    Efficacy of Diacetate Esters of Macular Carotenoids: Effect of Supplementation on Macular Pigment

    by Richard A. Bone, John T. Landrum, Anirbaan Mukherjee

    The accumulation of the carotenoids lutein, zeaxanthin, and mesozeaxanthin in the center of the human retina, and known as the macula lutea or macular pigment, is believed to protect the retina from age-related macular degeneration. Since the macular pigment is of dietary origin, supplements containing the relevant carotenoids are readily available. In this study, we compared the changes in macular pigment over a 24-week supplementation period for two groups of 24 subjects each assigned to either of two supplement formulations, 20 mg/day of lutein or 20 mg equivalent free carotenoids of a combination of diacetate esters of the macular carotenoids. The latter group responded with a larger increase (0.0666 ± 0.0481) in macular pigment optical density than the former group (0.0398 ± 0.0430), driven largely by the older subjects. The difference was statistically significant (p=0.0287). There was a general trend towards smaller increases in macular pigment for those subjects whose baseline value was high. However, the trend was only significant (p<0.05) for subjects in the diacetate group. No differences in response could be attributed to the gender of the subjects. We also observed no indication that the use of statin drugs by a few of the older subjects influenced their responses.


  • Open Access

    Lens density measurements by two independent psychophysical techniques

    by Anirbaan Mukherjee, Richard A. Bone

    Cataract, a leading cause of vision impairment, is due to the lens becoming excessively optically dense. Change in the lens optical density (LOD) could be a useful indicator of incipient nuclear cataract and would necessitate the development of accurate measurement techniques. Mapcat sf™ is a heterochromatic flicker photometer for measuring macular pigment optical density (MPOD) under photopic conditions. In the process, it also measures LOD that is needed in the calculation of MPOD. LOD is then converted by the instrument to “lens equivalent age” (LEA). However, varying cone photoreceptor ratios among individuals could affect the LEA measurement. Scotopic vision is mediated by rod photoreceptors; therefore, LEA measurement under scotopic conditions potentially provides a reliable standard for assessing other methods. The study was conducted to test the level of agreement between the LEA data obtained under photopic and scotopic conditions for a sample population. We also comment on factors that might contribute to any disagreement. LEAs were obtained by Mapcat sf for 25 subjects and compared with those obtained under absolute scotopic threshold conditions. The mean scotopic LEA for the subjects was 2.7 years higher than the mean photopic LEA, but this difference was not statistically significant. Measurements by the two methods were reasonably correlated (r2 = 0.59, p < 0.0001). Significant individual differences in LEA by the two methods were found for six of the 25 subjects. Although our calculations included a standard long- to medium-wavelength-sensitive cone ratio, we found that different ratios could be found that rendered the differences in LEA insignificant for two of these six subjects. Variability in pupil diameter during scotopic measurements was considered another potential source of discrepancy between LEAs by the two methods. The absolute threshold technique, with long adaptation times, is probably impractical for routine lens density measurement, whereas Mapcat sf provided a rapid, straightforward test that may find its application in optometric/ophthalmic practice.

  • Open Access

    Light distributions on the retina: relevance to macular pigment photoprotection.

    by Richard A Bone, Jorge C Gibert, Anirbaan Mukherjee

    Light exposure has been implicated in age-related macular degeneration (AMD). This study was designed to measure cumulative light distribution on the retina to determine whether it peaked in the macula. An eye-tracker recorded the subject's field of view and pupil size, and superimposed the gaze position. Fifteen naïve subjects formed a test group; 5 formed a control group. In phase 1, all subjects viewed a sequence of photographic images. In phase 2, the naïve subjects observed a video; in phase 3, they performed computer tasks; in phase 4, the subjects walked around freely. In phase 1, control subjects were instructed to gaze at bright features in the field of view and, in a second test, at dark features. Test group subjects were allowed to gaze freely for all phases. Using the subject's gaze coordinates, we calculated the cumulative light distribution on the retina. As expected for control subjects, cumulative retinal light distributions peaked and dipped in the fovea when they gazed at bright or dark features respectively in the field of view. The light distribution maps obtained from the test group showed a consistent tendency to peak in the macula in phase 3, a variable tendency in phase 4, but little tendency in phases 1 and 2. We conclude that a tendency for light to peak in the macula is a characteristic of some individuals and of certain tasks. In these situations, risk of AMD could be increased but, at the same time, mitigated by the presence of macular carotenoids.


  • Optical anisotropy of the human cornea determined with a polarizing microscope

    by Richard A. Bone, Grenville Draper

    We have investigated the optical anisotropy of the human cornea using a polarizing microscope normally used for optical mineralogy studies. The central part of the cornea was removed from 14 eyes (seven donors). With the sample placed on the microscope stage, we consistently observed hyperbolic isogyres characteristic of a negative biaxial material. The angle between the optic axes, generally similar in both eyes, ranged from 12° to 40° (mean±SD=31°±8°). The optic axial plane always inclined downward in the nasal direction at 1°–45° below the horizontal (mean±SD=22±13°). The retardance produced by the corneas was estimated to be less than 200  nm. In conclusion, the human cornea possesses the anisotropy of a negative biaxial material. Both the angle between the optic axes and the retardance were fairly constant among the majority of samples, suggestive of uniformity in corneal structure.


  • Open Access

    Macular pigment response to a supplement containing meso-zeaxanthin, lutein and zeaxanthin

    by Richard A Bone, John T Landrum, Yisi Cao, Alan N Howard, Francesca Alvarez-Calderon

    Age-related macular degeneration (AMD) is a disease with multiple risk factors, many of which appear to involve oxidative stress. Macular pigment, with its antioxidant and light-screening properties, is thought to be protective against AMD. A result has been the appearance of dietary supplements containing the macular carotenoids, lutein and zeaxanthin. More recently, a supplement has been marketed containing, in addition, the third major carotenoid of the macular pigment, meso-zeaxanthin. The purpose of the study was to determine the effectiveness of such a supplement in raising macular pigment density in human subjects.


  • Macular pigment and the edge hypothesis of flicker photometry

    by Richard A. Bone, John T. Landrum, Jorge C. Gibert