Raymond Alcorn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Raymond Alcorn has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Anthony Lewis
12 shared publications- Wanan Sheng
Department of Aerospace and Mechanical Engineering, South East Technological University, Carlow, R93 V960, Ireland
12 shared publications Tony Lewis
5 shared publicationsAnne Blavette
4 shared publicationsMark Healy
3 shared publicationsMichael G. Egan
Department of Electrical Engineering, University College Cork, Cork, Ireland
3 shared publications
Latest Publications
- 17 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 7 (3) , 1216-1223
Simplified Estimation of the Flicker Level Induced by Wave Energy Farms
Wave energy farms may cause voltage flicker on the local grid to which they will be connected due to the strong fluctuations that their output power may present. IEC standard 61400-21 describes methods for estimating the flicker level for different short-circuit ratios as well as for different numbers of devices composing the farm. This method was initially developed for wind farms but is applicable to wave energy farms as well. However, besides the short-circuit ratio and the number of devices composing the farm, the grid impedance angle has also a strong influence on flicker. Despite this, no method exists in the literature for estimating flicker as a function of this variable. This paper presents the results of a study intended to fill this gap by focusing on developing a simplified method for estimating the flicker level induced by a wave energy farm as a function of the grid impedance angle. The results obtained through this method are compared with those obtained from numerical load flow simulations performed with PowerFactory. These simulations were based on experimental power output time series of a wave energy prototype deployed at sea as part of the European CORES project. The voltage profiles thus generated were then processed by means of a flickermeter compliant with IEC standard 61000-4-15.
- 17 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 7 (3) , 1216-1223
Simplified Estimation of the Flicker Level Induced by Wave Energy Farms
Wave energy farms may cause voltage flicker on the local grid to which they will be connected due to the strong fluctuations that their output power may present. IEC standard 61400-21 describes methods for estimating the flicker level for different short-circuit ratios as well as for different numbers of devices composing the farm. This method was initially developed for wind farms but is applicable to wave energy farms as well. However, besides the short-circuit ratio and the number of devices composing the farm, the grid impedance angle has also a strong influence on flicker. Despite this, no method exists in the literature for estimating flicker as a function of this variable. This paper presents the results of a study intended to fill this gap by focusing on developing a simplified method for estimating the flicker level induced by a wave energy farm as a function of the grid impedance angle. The results obtained through this method are compared with those obtained from numerical load flow simulations performed with PowerFactory. These simulations were based on experimental power output time series of a wave energy prototype deployed at sea as part of the European CORES project. The voltage profiles thus generated were then processed by means of a flickermeter compliant with IEC standard 61000-4-15.
- 1 September 2015
- Published by Elsevier in Ocean Engineering
- Vol. 105, 43-53
A new method for radiation forces for floating platforms in waves
- 1 September 2015
- Published by Elsevier in Ocean Engineering
- Vol. 105, 43-53
A new method for radiation forces for floating platforms in waves
- 1 March 2015
- Published by Elsevier in Renewable Energy
- Vol. 75, 922-934
On improving wave energy conversion, part I: Optimal and control technologies
- 1 March 2015
- Published by Elsevier in Renewable Energy
- Vol. 75, 922-934
On improving wave energy conversion, part I: Optimal and control technologies
- 1 March 2015
- Published by Elsevier in Renewable Energy
- Vol. 75, 935-944
On improving wave energy conversion, part II: Development of latching control technologies
- 1 March 2015
- Published by Elsevier in Renewable Energy
- Vol. 75, 935-944
On improving wave energy conversion, part II: Development of latching control technologies
- 1 September 2014
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 6 (5) , 053114
Assessment of primary energy conversions of oscillating water columns. II. Power take-off and validations
This is the second part of the assessment of primary energy conversions of oscillating water columns (OWCs) wave energy converters. In the first part of the research work, the hydrodynamic performance of OWC wave energy converter has been extensively examined, targeting on a reliable numerical assessment method. In this part of the research work, the application of the air turbine power take-off (PTO) to the OWC device leads to a coupled model of the hydrodynamics and thermodynamics of the OWC wave energy converters, in a manner that under the wave excitation, the varying air volume due to the internal water surface motion creates a reciprocating chamber pressure (alternative positive and negative chamber pressure), whilst the chamber pressure, in turn, modifies the motions of the device and the internal water surface. To do this, the thermodynamics of the air chamber is first examined and applied by including the air compressibility in the oscillating water columns for different types of the air turbine PTOs. The developed thermodynamics is then coupled with the hydrodynamics of the OWC wave energy converters. This proposed assessment method is then applied to two generic OWC wave energy converters (one bottom fixed and another floating), and the numerical results are compared to the experimental results. From the comparison to the model test data, it can be seen that this numerical method is capable of assessing the primary energy conversion for the oscillating water column wave energy converters.
- 1 September 2014
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 6 (5) , 053114
Assessment of primary energy conversions of oscillating water columns. II. Power take-off and validations
This is the second part of the assessment of primary energy conversions of oscillating water columns (OWCs) wave energy converters. In the first part of the research work, the hydrodynamic performance of OWC wave energy converter has been extensively examined, targeting on a reliable numerical assessment method. In this part of the research work, the application of the air turbine power take-off (PTO) to the OWC device leads to a coupled model of the hydrodynamics and thermodynamics of the OWC wave energy converters, in a manner that under the wave excitation, the varying air volume due to the internal water surface motion creates a reciprocating chamber pressure (alternative positive and negative chamber pressure), whilst the chamber pressure, in turn, modifies the motions of the device and the internal water surface. To do this, the thermodynamics of the air chamber is first examined and applied by including the air compressibility in the oscillating water columns for different types of the air turbine PTOs. The developed thermodynamics is then coupled with the hydrodynamics of the OWC wave energy converters. This proposed assessment method is then applied to two generic OWC wave energy converters (one bottom fixed and another floating), and the numerical results are compared to the experimental results. From the comparison to the model test data, it can be seen that this numerical method is capable of assessing the primary energy conversion for the oscillating water column wave energy converters.
- 1 September 2014
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 6 (5) , 053113
Assessment of primary energy conversions of oscillating water columns. I. Hydrodynamic analysis
This is an investigation on the development of a numerical assessment method for the hydrodynamic performance of an oscillating water column (OWC) wave energy converter. In the research work, a systematic study has been carried out on how the hydrodynamic problem can be solved and represented reliably, focusing on the phenomena of the interactions of the wave-structure and the wave-internal water surface. These phenomena are extensively examined numerically to show how the hydrodynamic parameters can be reliably obtained and used for the OWC performance assessment. In studying the dynamic system, a two-body system is used for the OWC wave energy converter. The first body is the device itself, and the second body is an imaginary “piston,” which replaces part of the water at the internal water surface in the water column. One advantage of the two-body system for an OWC wave energy converter is its physical representations, and therefore, the relevant mathematical expressions and the numerical simulation can be straightforward. That is, the main hydrodynamic parameters can be assessed using the boundary element method of the potential flow in frequency domain, and the relevant parameters are transformed directly from frequency domain to time domain for the two-body system. However, as it is shown in the research, an appropriate representation of the “imaginary” piston is very important, especially when the relevant parameters have to be transformed from frequency-domain to time domain for a further analysis. The examples given in the research have shown that the correct parameters transformed from frequency domain to time domain can be a vital factor for a successful numerical simulation.
- 1 September 2014
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 6 (5) , 053113
Assessment of primary energy conversions of oscillating water columns. I. Hydrodynamic analysis
This is an investigation on the development of a numerical assessment method for the hydrodynamic performance of an oscillating water column (OWC) wave energy converter. In the research work, a systematic study has been carried out on how the hydrodynamic problem can be solved and represented reliably, focusing on the phenomena of the interactions of the wave-structure and the wave-internal water surface. These phenomena are extensively examined numerically to show how the hydrodynamic parameters can be reliably obtained and used for the OWC performance assessment. In studying the dynamic system, a two-body system is used for the OWC wave energy converter. The first body is the device itself, and the second body is an imaginary “piston,” which replaces part of the water at the internal water surface in the water column. One advantage of the two-body system for an OWC wave energy converter is its physical representations, and therefore, the relevant mathematical expressions and the numerical simulation can be straightforward. That is, the main hydrodynamic parameters can be assessed using the boundary element method of the potential flow in frequency domain, and the relevant parameters are transformed directly from frequency domain to time domain for the two-body system. However, as it is shown in the research, an appropriate representation of the “imaginary” piston is very important, especially when the relevant parameters have to be transformed from frequency-domain to time domain for a further analysis. The examples given in the research have shown that the correct parameters transformed from frequency domain to time domain can be a vital factor for a successful numerical simulation.
- 26 August 2014
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 33 (5) , 1678-1704
Challenges and lessons learned in the deployment of an offshore oscillating water column
Purpose: – The purpose of this paper is to disseminate the lessons learned from the successful deployment of a wave energy converter (WEC) and accelerate growth in the field of ocean energy. Design/methodology/approach: – A thorough, well structured, documented, industrial approach was taken to the deployment because of the depth and scale of the task required. This approach is shown throughout the paper, which reflects the importance of a comprehensive project plan in success as well as failure. Findings: – The findings demonstrate the viability of the use of off shore WEC to generate electricity and that such a project can be completed on time and on budget. Research limitations/implications: – The research implications of the paper include the importance of an enhanced, integrated supervisory system control in terms of efficiency, operation and maintenance, and long-term viability of WECs. This paper can be used to help guide the direction of further research in similar areas. Practical implications: – The practical implications include proof that WEC deployments can be carried out both on time and under budget. It highlights much of the practical data collected throughout the course of the project and presents it so that it might be used as a guide for future projects. Originality/value: – At the time of this paper, successful deployment of off shore WECs has been a rare accomplishment. Because the project was publicly funded, the data collected during this project, both technical and practical, is freely available.
- 26 August 2014
- Published by Emerald Publishing in COMPEL - The international journal for computation and mathematics in electrical and electronic engineering
- Vol. 33 (5) , 1678-1704
Challenges and lessons learned in the deployment of an offshore oscillating water column
Purpose: – The purpose of this paper is to disseminate the lessons learned from the successful deployment of a wave energy converter (WEC) and accelerate growth in the field of ocean energy. Design/methodology/approach: – A thorough, well structured, documented, industrial approach was taken to the deployment because of the depth and scale of the task required. This approach is shown throughout the paper, which reflects the importance of a comprehensive project plan in success as well as failure. Findings: – The findings demonstrate the viability of the use of off shore WEC to generate electricity and that such a project can be completed on time and on budget. Research limitations/implications: – The research implications of the paper include the importance of an enhanced, integrated supervisory system control in terms of efficiency, operation and maintenance, and long-term viability of WECs. This paper can be used to help guide the direction of further research in similar areas. Practical implications: – The practical implications include proof that WEC deployments can be carried out both on time and under budget. It highlights much of the practical data collected throughout the course of the project and presents it so that it might be used as a guide for future projects. Originality/value: – At the time of this paper, successful deployment of off shore WECs has been a rare accomplishment. Because the project was publicly funded, the data collected during this project, both technical and practical, is freely available.
- 1 July 2014
- Published by Elsevier in Ocean Engineering
- Vol. 84, 29-36
Physical modelling of wave energy converters
- 1 July 2014
- Published by Elsevier in Ocean Engineering
- Vol. 84, 29-36
Physical modelling of wave energy converters
- 8 June 2014
- Published by ASME International
Numerical Assessment on Primary Wave Energy Conversion of Oscillating Water Columns
Oscillating water column (OWC) wave energy converters (WECs) are probably the simplest and most promising wave energy converters due to their good feasibility, reliability and survivability in practical wave energy conversions and also regarded as the most studied and developed when compared to other types of the wave energy converters. This research aims to develop a reliable numerical tool to assess the performance of the OWC wave energy converters, particularly in the primary wave energy conversion. In the numerical assessment tool, the hydrodynamics of the device and thermodynamics of the air chamber can be studied separately. However, for the complete dynamic system when a power takeoff (PTO) system is applied, these two dynamic systems are fully coupled in time-domain, in which the PTO can have a simple mathematical expression as the relation between the pressure difference across the PTO (the chamber pressure) and its flowrate through the PTO. And the application of a simple PTO pressure-flowrate relation very much simplifies the complicated aerodynamics and thermodynamics in the air turbine system so the whole dynamic system can be simplified. The methodology has been applied to a generic OWC device and the simulation results have been compared to the experimental data. It is shown that the developed numerical method is reliable in and capable of assessing the primary wave energy conversion of oscillating water columns.
- 8 June 2014
- Published by ASME International
Numerical Assessment on Primary Wave Energy Conversion of Oscillating Water Columns
Oscillating water column (OWC) wave energy converters (WECs) are probably the simplest and most promising wave energy converters due to their good feasibility, reliability and survivability in practical wave energy conversions and also regarded as the most studied and developed when compared to other types of the wave energy converters. This research aims to develop a reliable numerical tool to assess the performance of the OWC wave energy converters, particularly in the primary wave energy conversion. In the numerical assessment tool, the hydrodynamics of the device and thermodynamics of the air chamber can be studied separately. However, for the complete dynamic system when a power takeoff (PTO) system is applied, these two dynamic systems are fully coupled in time-domain, in which the PTO can have a simple mathematical expression as the relation between the pressure difference across the PTO (the chamber pressure) and its flowrate through the PTO. And the application of a simple PTO pressure-flowrate relation very much simplifies the complicated aerodynamics and thermodynamics in the air turbine system so the whole dynamic system can be simplified. The methodology has been applied to a generic OWC device and the simulation results have been compared to the experimental data. It is shown that the developed numerical method is reliable in and capable of assessing the primary wave energy conversion of oscillating water columns.