Rodolfo E. Perez-Roa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rodolfo E. Perez-Roa has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Marc A. Anderson
7 shared publications- Daniel R. Noguera
Great Lakes Bioenergy Research Center, University of Wisconsin-Madison
3 shared publications Jesse J. Wouters
3 shared publicationsM. Isabel Tejedor-Tejedor
3 shared publicationsDan Rittschof
Duke University Marine Laboratory, Duke University , Beaufort , NC , USA
2 shared publications- Julio. J. Lado
Electrochemical Processes Unit, IMDEA Energy, Avda. Ramón de la Sagra 3, 28935 Móstoles, Madrid, Spain
2 shared publications
Latest Publications
- 1 August 2016
- Published by Elsevier in Journal of Energy Storage
- Vol. 7, 147-158
Performance of metal oxide nanoparticle sols as binders in activated carbon electrodes
- 1 August 2016
- Published by Elsevier in Journal of Energy Storage
- Vol. 7, 147-158
Performance of metal oxide nanoparticle sols as binders in activated carbon electrodes
- 1 December 2015
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 3 (4) , 2358-2367
Continuous cycling of an asymmetric capacitive deionization system: An evaluation of the electrode performance and stability
- 1 December 2015
- Published by Elsevier in Journal of Environmental Chemical Engineering
- Vol. 3 (4) , 2358-2367
Continuous cycling of an asymmetric capacitive deionization system: An evaluation of the electrode performance and stability
- 1 August 2014
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 35 (1) , 37-43
Contribution of metals, sulfur-dioxide and phenolic compounds to the antioxidant capacity of Carménère wines
- 1 August 2014
- Published by Elsevier in Journal of Food Composition and Analysis
- Vol. 35 (1) , 37-43
Contribution of metals, sulfur-dioxide and phenolic compounds to the antioxidant capacity of Carménère wines
- 30 April 2013
- Published by Elsevier in Electrochimica Acta
- Vol. 104, 314-321
Electrochemical response of titania, zirconia, and alumina electrodes to phosphate adsorption
- 30 April 2013
- Published by Elsevier in Electrochimica Acta
- Vol. 104, 314-321
Electrochemical response of titania, zirconia, and alumina electrodes to phosphate adsorption
- 5 December 2012
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 160 (2) , H105-H112
Effects of pH on Phosphate Adsorption to Hematite as Studied with Cyclic Voltammetry and Electrochemical Impedance Spectroscopy
Nanoporous hematite (α-Fe2O3) coated electrodes were applied for the investigation of the electrochemical effects of pH on adsorption of the phosphate ion to iron oxide in concentrations commonly found in natural waters. The hematite electrode was tested with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods in NaClO4 solution and in 10−8 – 10−4 M phosphate over the pH range 6.00 – 8.75. In cyclic voltammograms, the current features attributed to specific adsorption of H+ or OH− were accentuated by phosphate addition. Impedance studies indicated that hematite behaved like a blocking electrode with deviations to blocking behavior occurring at higher pH and with increased phosphate. Resultant spectra were modeled with an analog electric circuit with a resistor in series with three parallel lines consisting of resistive, capacitive, and constant phase elements (CPEs) highlighting processes over sections of the applied EIS frequency range. This analysis of the phosphate-hematite system may assist with the production of an electrochemical sensor for phosphate at environmentally relevant pH.
- 5 December 2012
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 160 (2) , H105-H112
Effects of pH on Phosphate Adsorption to Hematite as Studied with Cyclic Voltammetry and Electrochemical Impedance Spectroscopy
Nanoporous hematite (α-Fe2O3) coated electrodes were applied for the investigation of the electrochemical effects of pH on adsorption of the phosphate ion to iron oxide in concentrations commonly found in natural waters. The hematite electrode was tested with cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) methods in NaClO4 solution and in 10−8 – 10−4 M phosphate over the pH range 6.00 – 8.75. In cyclic voltammograms, the current features attributed to specific adsorption of H+ or OH− were accentuated by phosphate addition. Impedance studies indicated that hematite behaved like a blocking electrode with deviations to blocking behavior occurring at higher pH and with increased phosphate. Resultant spectra were modeled with an analog electric circuit with a resistor in series with three parallel lines consisting of resistive, capacitive, and constant phase elements (CPEs) highlighting processes over sections of the applied EIS frequency range. This analysis of the phosphate-hematite system may assist with the production of an electrochemical sensor for phosphate at environmentally relevant pH.
- 30 April 2009
- Published by Taylor & Francis in Biofouling
- Vol. 25 (6) , 563-571
Involvement of reactive oxygen species in the electrochemical inhibition of barnacle (Amphibalanus amphitrite) settlement
The role of reactive oxygen species (ROS) in electrochemical biofouling inhibition was investigated using a series of abiotic tests and settlement experiments with larvae of the barnacle Amphibalanus amphitrite, a cosmopolitan fouler. Larval settlement, a measure of biofouling potential, was reduced from 43% ± 14% to 5% ± 6% upon the application of pulsed electric signals. The application of ROS scavengers such as glutathione and catalase counteracted the inhibitory effects of the electric signals, allowing settlement, and thus indicating that ROS are antifouling agents. Based on the experimental evidence, the proposed mechanism for ROS-based fouling prevention with interdigitated electrodes involved the electrochemical generation of hydrogen peroxide by oxygen reduction, and its likely reduction to hydroxyl radicals. Either hydroxyl radicals or products of hydroxyl radical reactions appeared to be the main deterrents of larval settlement.
- 30 April 2009
- Published by Taylor & Francis in Biofouling
- Vol. 25 (6) , 563-571
Involvement of reactive oxygen species in the electrochemical inhibition of barnacle (Amphibalanus amphitrite) settlement
The role of reactive oxygen species (ROS) in electrochemical biofouling inhibition was investigated using a series of abiotic tests and settlement experiments with larvae of the barnacle Amphibalanus amphitrite, a cosmopolitan fouler. Larval settlement, a measure of biofouling potential, was reduced from 43% ± 14% to 5% ± 6% upon the application of pulsed electric signals. The application of ROS scavengers such as glutathione and catalase counteracted the inhibitory effects of the electric signals, allowing settlement, and thus indicating that ROS are antifouling agents. Based on the experimental evidence, the proposed mechanism for ROS-based fouling prevention with interdigitated electrodes involved the electrochemical generation of hydrogen peroxide by oxygen reduction, and its likely reduction to hydroxyl radicals. Either hydroxyl radicals or products of hydroxyl radical reactions appeared to be the main deterrents of larval settlement.
- 17 March 2008
- Published by Taylor & Francis in Biofouling
- Vol. 24 (3) , 177-184
Inhibition of barnacle (Amphibalanus amphitrite) cyprid settlement by means of localized, pulsed electric fields
The increasing needs for environmental friendly antifouling coatings have led to investigation of new alternatives for replacing copper and TBT-based paints. In this study, results are presented from larval settlement assays of the barnacle Amphibalanus (= Balanus) amphitrite on planar, interdigitated electrodes (IDE), having 8 or 25 μm of inter-electrode spacing, upon the application of pulsed electric fields (PEF). Using pulses of 100 ms in duration, 200 Hz in frequency and 10 V in pulse amplitude, barnacle settlement below 5% was observed, while similar IDE surfaces without pulse application had an average of 40% settlement. The spacing between the electrodes did not affect cyprid settlement. Assays with lower PEF amplitudes did not show significant settlement inhibition. On the basis of the settlement assays, the calculated minimum energy requirement to inhibit barnacle settlement is 2.8 W h m−2.
- 17 March 2008
- Published by Taylor & Francis in Biofouling
- Vol. 24 (3) , 177-184
Inhibition of barnacle (Amphibalanus amphitrite) cyprid settlement by means of localized, pulsed electric fields
The increasing needs for environmental friendly antifouling coatings have led to investigation of new alternatives for replacing copper and TBT-based paints. In this study, results are presented from larval settlement assays of the barnacle Amphibalanus (= Balanus) amphitrite on planar, interdigitated electrodes (IDE), having 8 or 25 μm of inter-electrode spacing, upon the application of pulsed electric fields (PEF). Using pulses of 100 ms in duration, 200 Hz in frequency and 10 V in pulse amplitude, barnacle settlement below 5% was observed, while similar IDE surfaces without pulse application had an average of 40% settlement. The spacing between the electrodes did not affect cyprid settlement. Assays with lower PEF amplitudes did not show significant settlement inhibition. On the basis of the settlement assays, the calculated minimum energy requirement to inhibit barnacle settlement is 2.8 W h m−2.
- 1 January 2006
- Published by Elsevier in Atmospheric Environment
- Vol. 40 (1) , 109-125
Air-pollution modelling in an urban area: Correlating turbulent diffusion coefficients by means of an artificial neural network approach
- 1 January 2006
- Published by Elsevier in Atmospheric Environment
- Vol. 40 (1) , 109-125
Air-pollution modelling in an urban area: Correlating turbulent diffusion coefficients by means of an artificial neural network approach
- 1 January 2006
- Published by Taylor & Francis in Biofouling
- Vol. 22 (6) , 383-390
Effects of localised, low-voltage pulsed electric fields on the development and inhibition ofPseudomonas aeruginosabiofilms
This work describes the use of low-voltage (0.5 – 5 V) pulsed electric fields to prevent Pseudomonas aeruginosa biofilm development. Interdigitated electrodes (IDEs) with 29-μm spacing between 22-μm-wide electrodes, were used as a platform where the effect of localised, high-strength electric fields could be tested. Alternating current, square-wave pulses were applied to the IDEs in 1 sec intervals. A two-level, three-variable factorial design experiment was used to detect the effects of applied voltage, frequency, and pulse duty ratio (i.e. percentage of pulsing time over one cycle) on the inhibition of biofilm formation. The observations indicated that a pulse configuration of 1% duty ratio, 5 V, and 200 Hz frequency reduced the area of the electrodes covered by biofilm by 50%. In general, the application of low-duty ratio pulses had a positive effect on preventing biofouling. Comparatively, frequency and applied voltage were observed to have less influence on biofouling.
- 1 January 2006
- Published by Taylor & Francis in Biofouling
- Vol. 22 (6) , 383-390
Effects of localised, low-voltage pulsed electric fields on the development and inhibition ofPseudomonas aeruginosabiofilms
This work describes the use of low-voltage (0.5 – 5 V) pulsed electric fields to prevent Pseudomonas aeruginosa biofilm development. Interdigitated electrodes (IDEs) with 29-μm spacing between 22-μm-wide electrodes, were used as a platform where the effect of localised, high-strength electric fields could be tested. Alternating current, square-wave pulses were applied to the IDEs in 1 sec intervals. A two-level, three-variable factorial design experiment was used to detect the effects of applied voltage, frequency, and pulse duty ratio (i.e. percentage of pulsing time over one cycle) on the inhibition of biofilm formation. The observations indicated that a pulse configuration of 1% duty ratio, 5 V, and 200 Hz frequency reduced the area of the electrodes covered by biofilm by 50%. In general, the application of low-duty ratio pulses had a positive effect on preventing biofouling. Comparatively, frequency and applied voltage were observed to have less influence on biofouling.