Srikrishna Parthasarathi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Srikrishna Parthasarathi has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Arun Kumar Singh
Microwave Tube Research and Development Centre (DRDO)
2 shared publications - Siddharth Nagarajan
MTRDC, DRDO, Bangalore, India
2 shared publications - Venkat
MTRDC, DRDO, Bangalore - 560013, Karnataka
2 shared publications C. Suresh
Defence Research and Development Organisation
1 shared publicationC.H. Vijay Kumar
Department of Mechanical Engineering, Microwave Tube Research and Development Centre, Bangalore, India
1 shared publicationG. S. V. L. Narasimham
Department of Mechanical Engineering, Indian Institute of Science
1 shared publication
Latest Publications
- 14 October 2023
- Published by Taylor & Francis in Advances in Materials and Processing Technologies
- Vol. 10 (4) , 3741-3763
Micro-electro discharge machining characteristics of tungsten-copper for electronic devices
- 14 October 2023
- Published by Taylor & Francis in Advances in Materials and Processing Technologies
- Vol. 10 (4) , 3741-3763
Micro-electro discharge machining characteristics of tungsten-copper for electronic devices
- 5 May 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 57 (11) , 1871-1892
Effect of bend radius and insulation on adiabatic section on the performance of a single closed loop pulsating heat pipe: experimental study and heat transfer correlation
- 5 May 2021
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 57 (11) , 1871-1892
Effect of bend radius and insulation on adiabatic section on the performance of a single closed loop pulsating heat pipe: experimental study and heat transfer correlation
- 18 March 2019
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 55 (9) , 2637-2649
Experimental investigation of flat plate closed loop pulsating heat pipe
- 18 March 2019
- Published by Springer Nature in Heat and Mass Transfer
- Vol. 55 (9) , 2637-2649
Experimental investigation of flat plate closed loop pulsating heat pipe
- 11 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 65 (6) , 2218-2226
Thermal Analysis of High-Average Power Helix Traveling-Wave Tube
The thermal simulation using ANSYS was carried out for estimating the maximum temperature and the temperature distribution in a high-average power broadband helix traveling-wave tube (TWT). The simulation was first carried out independently for the subassemblies such as the slow-wave structure, the output coupler, and the depressed collector; and the combined effect on the overall temperature inside the TWT was estimated subsequently. The simulation was carried out using several options of thermal interface resistances such as 100% contact and 50% contact, apart from considering various structural configurations, and an optimal thermal management solution was evolved for the device under consideration.
- 11 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 65 (6) , 2218-2226
Thermal Analysis of High-Average Power Helix Traveling-Wave Tube
The thermal simulation using ANSYS was carried out for estimating the maximum temperature and the temperature distribution in a high-average power broadband helix traveling-wave tube (TWT). The simulation was first carried out independently for the subassemblies such as the slow-wave structure, the output coupler, and the depressed collector; and the combined effect on the overall temperature inside the TWT was estimated subsequently. The simulation was carried out using several options of thermal interface resistances such as 100% contact and 50% contact, apart from considering various structural configurations, and an optimal thermal management solution was evolved for the device under consideration.
- 15 March 2017
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 46 (7) , 4414-4419
Experimental Evaluation and Comparison of Thermal Conductivity of High-Voltage Insulation Materials for Vacuum Electronic Devices
- 15 March 2017
- Published by Springer Nature in Journal of Electronic Materials
- Vol. 46 (7) , 4414-4419
Experimental Evaluation and Comparison of Thermal Conductivity of High-Voltage Insulation Materials for Vacuum Electronic Devices
- Open Access
- 22 September 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (34)
Vibration Analysis of Printed Circuit Board Plate with Varying Boundary Conditions
Objectives: The Young’s Modulus (E) plays key role in the vibration response of any structure. Hence its estimate with reasonable accuracy is of paramount importance. The Printed Circuit Board (PCB) used in military application consists of more than 6 layers, with pre-peg and copper composition. Methods/Statistical Analysis: The multiple layers PCB E value will vary from one design to other as it depends on the composition of layers. These PCB plates are subjected to vibration loads – sine, random and shock. A detailed work has been carried out to quantify the mechanical property of Young’s Modulus (E) of the PCB plate both analytically and experimentally. Findings: This E value obtained was used in the FEM analysis (using ANSYS 16) to solve the vibration response of the PCB. The study also includes analytical calculation and experimental estimation of natural frequency of the PCB plate for different boundary conditions. The natural frequency estimation through analytical and experimental methods show good correlation thus validating the estimation procedure of E of the PCB as well. Application: This work gives us a robust method for estimating Young’s modulus of Multi-layer PCB which find application in variety of military electronics.
- 22 September 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (34)
Open AccessVibration Analysis of Printed Circuit Board Plate with Varying Boundary Conditions
Objectives: The Young’s Modulus (E) plays key role in the vibration response of any structure. Hence its estimate with reasonable accuracy is of paramount importance. The Printed Circuit Board (PCB) used in military application consists of more than 6 layers, with pre-peg and copper composition. Methods/Statistical Analysis: The multiple layers PCB E value will vary from one design to other as it depends on the composition of layers. These PCB plates are subjected to vibration loads – sine, random and shock. A detailed work has been carried out to quantify the mechanical property of Young’s Modulus (E) of the PCB plate both analytically and experimentally. Findings: This E value obtained was used in the FEM analysis (using ANSYS 16) to solve the vibration response of the PCB. The study also includes analytical calculation and experimental estimation of natural frequency of the PCB plate for different boundary conditions. The natural frequency estimation through analytical and experimental methods show good correlation thus validating the estimation procedure of E of the PCB as well. Application: This work gives us a robust method for estimating Young’s modulus of Multi-layer PCB which find application in variety of military electronics.
- Open Access
- 20 September 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (34)
Design, Analysis and Testing of Multi-axis Vibration Fixture for Electronic Devices
Objectives: Any device required to operate under vibration environment has to be tested for the same. The mounting pattern of vibration shaker is fixed. Hence a fixture as adaptor is needed for mounting the Device Under Test (DUT). Method/Analysis: These fixtures are to be stiff (natural frequency > highest frequency of test spectrum) to avoid fixture resonance leading to amplification of loads. In the present study, two fixtures – 1) with single mount 3 orientation capability and 2) capable of for 3 axes simultaneous loading were designed, analysed (using ANSYS16) and developed with the aim of reducing time in a single test and effort during testing. Findings: The fixtures were tested by regular vibration shaker as well as a hand held analyser. The analysis and testing yielded good correlation for the natural frequency estimate (< 15% deviation).Using fixture-1, 4 units with 3 orientations can be tested simultaneously and each of the devices can be tested for the remaining orientations during the subsequent tests. With fixture-2 one can test the device for all 3 axes loading in a single test thus reducing the testing time when accounted across a number of devices. Applications: As most of the time and effort during vibration testing goes in change of orientation and arrangement of slip-table (assembly and dis-assembly of the fixture-DUT) the fixtures designed can go a long way in minimising the time and manual labour when accounted across many units.
- 20 September 2016
- Published by Indian Society for Education and Environment in Indian Journal of Science and Technology
- Vol. 9 (34)
Open AccessDesign, Analysis and Testing of Multi-axis Vibration Fixture for Electronic Devices
Objectives: Any device required to operate under vibration environment has to be tested for the same. The mounting pattern of vibration shaker is fixed. Hence a fixture as adaptor is needed for mounting the Device Under Test (DUT). Method/Analysis: These fixtures are to be stiff (natural frequency > highest frequency of test spectrum) to avoid fixture resonance leading to amplification of loads. In the present study, two fixtures – 1) with single mount 3 orientation capability and 2) capable of for 3 axes simultaneous loading were designed, analysed (using ANSYS16) and developed with the aim of reducing time in a single test and effort during testing. Findings: The fixtures were tested by regular vibration shaker as well as a hand held analyser. The analysis and testing yielded good correlation for the natural frequency estimate (< 15% deviation).Using fixture-1, 4 units with 3 orientations can be tested simultaneously and each of the devices can be tested for the remaining orientations during the subsequent tests. With fixture-2 one can test the device for all 3 axes loading in a single test thus reducing the testing time when accounted across a number of devices. Applications: As most of the time and effort during vibration testing goes in change of orientation and arrangement of slip-table (assembly and dis-assembly of the fixture-DUT) the fixtures designed can go a long way in minimising the time and manual labour when accounted across many units.