    Calibration of Gamma Ray Impacts in Monolithic-Based Detectors Using Voronoi Diagrams

    by Marta Freire, Andrea Gonzalez-Montoro, Filomeno Sanchez, Jose M. Benlloch, Antonio J. Gonzalez

    Molecular imaging systems, such as positron emission tomography (PET), use detectors providing energy and a 3-D interaction position of a gamma ray within a scintillation block. Monolithic crystals are becoming an alternative to crystal arrays in PET. However, calibration processes are required to correct for nonuniformities, mainly produced by the truncation of the scintillation light distribution at the edges. We propose a calibration method based on the Voronoi diagrams. We have used 50 × 50 × 15 mm3 LYSO blocks coupled to a 12 × 12 SiPMs array. We have first studied two different interpolation algorithms: 1) weighted average method (WAM) and 2) natural neighbor (NN). We have compared them with an existing calibration based on 1-D monomials. Here, the crystal was laterally black painted and a retroreflector (RR) layer added to the entrance face. The NN exhibited the best results in terms of XY impact position, depth of Interaction, and energy, allowing us to calibrate the whole scintillation volume. Later, the NN interpolation has been tested against different crystal surface treatments, allowing always to correct edge effects. Best energy resolutions were observed when using the reflective layers (12%- 14%). However, better linearity was observed with the treatments using black paint. In particular, we obtained the best overall performance when lateral black paint is combined with the RR.


  • Characterization of LYSO and CeBr3 Detectors with Lateral Sides Readout for a Multilayer Compton-PET

    by John Barrio, Neus Cucarella, Antonio J. Gonzalez, Sergio Aguilar, Andrea Gonzalez-Montoro, Victor Ilisie, Efthymios Lamprou, Filomeno Sanchez, Jose M. Benlloch

    Two of the limitation factors of current PET scanners are their low sensitivity and lack of high image contrast. In order to improve these parameters, Compton interactions, which are usually discarded or unavoidably averaged, must be distinguished and included in the image reconstruction process. To achieve this, one of our proposals is a multi-layer detector approach employing thin scintillation layers with photodetectors coupled to all four lateral sides of the crystal. In the work presented here, a characterization of detectors based on LYSO and CeBr 3 crystals with lateral sides readout has been performed. Both crystals have an active volume of 51×51×3 mm 3 , resulting in a very high aspect ratio of 17. The CeBr 3 crystal also includes a 5 mm thick quartz glass frame due to encapsulation constraints. The obtained results show an energy resolution of 12.1% and 9.1% FWHM for the LYSO and CeBr 3 detectors, respectively. Pilot spatial resolutions ranging from 2.7 mm up to 4.3 mm for the LYSO crystal and from 4.1 mm up to 11.2 mm for the CeBr 3 crystal were observed. These results suggest that the quartz glass frame surrounding the CeBr 3 crystal significantly affects the light distribution of the optical photons reaching the photodetectors, worsening the performance of this kind of encapsulated detector.

  • TOF studies for dedicated PET with open geometries

    by L. Moliner, V. Ilisie, A. Gonzalez, S. Oliver, V. Gimenez-Alventosa, G. Cañizares, E. Lamprou, J. Alamo, F. Sanchez, M.J. Rodriguez, et al.

    Recently, two novel PET devices have been developed with open geometries, namely: breast and prostate-dedicated scanners. The breast-dedicated system comprises two detector rings of twelve modules with a field of view of 170 mm × 170 mm × 94 mm. Each module consists of a continuous trapezoidal LYSO crystal and a PSPMT. The system has the capability to vary the opening of the rings up to 60 mm in order to allow the insertion of a needle to perform a biopsy procedure. The prostate system has an open geometry consisting on two parallel plates separated 28 cm. One panel includes 18 detectors organized in a 6 × 3 matrix while the second one comprises 6 detectors organized in a 3 × 2 matrix. All detectors are formed by continuous LYSO crystals of 50 mm × 50 mm × 15 mm, and a SiPM array of 12 × 12 individual photo-detectors. The system geometry is asymmetric maximizing the sensitivity of the system at the prostate location, located at about 2/3 in the abdomen-anus distance. The reconstructed images for PET scanners with open geometries present severe artifacts due to this peculiarity. These artifacts can be minimized using Time Of Flight information (TOF). In this work we present a TOF resolution study for open geometries. With this aim, the dedicated breast and prostate systems have been simulated using GATE (8.1 version) with different TOF resolutions in order to determine the image quality improvements that can be achieved with the existing TOF-dedicated electronics currently present in the market. The images have been reconstructed using the LMOS algorithm including TOF modeling in the calculation of the voxel-Line Of Response emission probabilities.


  • Detector block performance based on a monolithic LYSO crystal using a novel signal multiplexing method

    by Andrea González-Montoro, Filomeno Sánchez, Rosana Martí, Liczandro Hernández, Albert Aguilar, Julio Barberá, Juan V. Catret, Gabriel Cañizares, Pablo Conde, Efthymios Lamprou, et al.


  • PET detector block with accurate 4D capabilities

    by Efthymios Lamprou, Albert Aguilar, Andrea González-Montoro, Jose M. Monzó, Gabriel Cañizares, Sofia Iranzo, Luis F. Vidal, Liczandro Hernández, Pablo Conde, Sebastian Sánchez, et al.


  • Open Access

    Feasibility Study of a Small Animal PET Insert Based on a Single LYSO Monolithic Tube

    by Antonio J. Gonzalez, Stuart S. Berr, Gabriel Cañizares, Andrea Gonzalez-Montoro, Abel Orero, Carlos Correcher, Ahmadreza Rezaei, Johan Nuyts, Filomeno Sanchez, Stan Majewski, et al.

    There are drawbacks with using a Positron Emission Tomography (PET) scanner design employing the traditional arrangement of multiple detectors in an array format. Typically PET systems are constructed with many regular gaps between the detector modules in a ring or box configuration, with additional axial gaps between the rings. Although this has been significantly reduced with the use of the compact high granularity SiPM photodetector technology, such a scanner design leads to a decrease in the number of annihilation photons that are detected causing lower scanner sensitivity. Moreover, the ability to precisely determine the line of response (LOR) along which the positron annihilated is diminished closer to the detector edges because the spatial resolution there is degraded due to edge effects. This happens for both monolithic based designs, caused by the truncation of the scintillation light distribution, but also for detector blocks that use crystal arrays with a number of elements that are larger than the number of photosensors and, therefore, make use of the light sharing principle. In this report we present a design for a small-animal PET scanner based on a single monolithic annulus-like scintillator that can be used as a PET insert in high-field Magnetic Resonance systems. We provide real data showing the performance improvement when edge-less modules are used. We also describe the specific proposed design for a rodent scanner that employs facetted outside faces in a single LYSO tube. In a further step, in order to support and prove the proposed edgeless geometry, simulations of that scanner have been performed and lately reconstructed showing the advantages of the design.


  • Organ-Dedicated Molecular Imaging Systems

    by Antonio J. Gonzalez, Filomeno Sanchez, Jose M. Benlloch

    In this review, we will cover both clinical and technical aspects of the advantages and disadvantages of organ specific (dedicated) molecular imaging (MI) systems, namely positron emission tomography (PET) and single photon emission computed tomography, including gamma cameras. This review will start with the introduction to the organ-dedicated MI systems. Thereafter, we will describe the differences and their advantages/disadvantages when compared with the standard large size scanners. We will review time evolution of dedicated systems, from first attempts to current scanners, and the ones that ended in clinical use. We will review later the state of the art of these systems for different organs, namely: breast, brain, heart, and prostate. We will also present the advantages offered by these systems as a function of the special application or field, such as in surgery, therapy assistance and assessment, etc. Their technological evolution will be introduced for each organ-based imager. Some of the advantages of dedicated devices are: higher sensitivity by placing the detectors closer to the organ, improved spatial resolution, better image contrast recovery (by reducing the noise from other organs), and also lower cost. Designing a complete ring-shaped dedicated PET scanner is sometimes difficult and limited angle tomography systems are preferable as they have more flexibility in placing the detectors around the body/organ. Examples of these geometries will be presented for breast, prostate and heart imaging. Recently achievable excellent time of flight capabilities below 300-ps full width at half of the maximum reduce significantly the impact of missing angles on the reconstructed images.


  • QR-Factorization Algorithm for Computed Tomography (CT): Comparison With FDK and Conjugate Gradient (CG) Algorithms

    by Maria Jose Rodriguez-Alvarez, Filomeno Sanchez, Antonio Soriano, Laura Moliner, Sebastian Sanchez, José María Benlloch

    Even though QR-factorization of the system matrix for tomographic devices has been already used for medical imaging, to date, no satisfactory solution has been found for solving large linear systems, such as those used in computed tomography (CT) (in the order of 10 6 equations). In CT, the Feldkamp, Davis, and Kress back projection algorithm (FDK) and iterative methods like conjugate gradient (CG) are the standard methods used for image reconstruction. As the image reconstruction problem can be modeled by a large linear system of equations, QR-factorization of the system matrix could be used to solve this system. Current advances in computer science enable the use of direct methods for solving such a large linear system. The QR-factorization is a numerically stable direct method for solving linear systems of equations, which is beginning to emerge as an alternative to traditional methods, bringing together the best from traditional methods. QR-factorization was chosen because the core of the algorithm, from the computational cost point of view, is precalculated and stored only once for a given CT system, and from then on, each image reconstruction only involves a backward substitution process and the product of a vector by a matrix. Image quality assessment was performed comparing contrast to noise ratio and noise power spectrum; performances regarding sharpness were evaluated by the reconstruction of small structures using data measured from a small animal 3-D CT. Comparisons of QR-factorization with FDK and CG methods show that QR-factorization is able to reconstruct more detailed images for a fixed voxel size.