Zafer Gemici
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zafer Gemici has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Aliihsan Koca
Istanbul Teknik Üniversitesi
5 shared publications - Baris Burak Kanbur
Section of Mechanical Engineering, Institute of Mechanical and Electrical Engineering, University of Southern Denmark (SDU), Odense, Denmark
3 shared publications - Şevket Özgür Atayılmaz
Thermodynamics and Heat Technology Division, Department of Mechanical Engineering, Yildiz Technical University, Yildiz, Turkey
3 shared publications - Ahmet Selim Dalkilic
Yıldız Technical University
2 shared publications - Emre Arpaci
Department of Mechanical Engineering, Faculty of Mechanical Engineering, Yildiz Technical University, Yildiz, Türkiye
2 shared publications Funda Erdem Şahnali
Mechanical Engineering Department, Yıldız Technical University
2 shared publications
Latest Publications
- Open Access
- 14 May 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 151 (9) , 8131-8150
Numerical analysis and transient thermal modeling of microwave dehydration of tomato: validation with experimental results
In this study, a model of microwave dehydration of tomato slices was created. The model illustrates the temperature variations during the microwave dehydration of tomatoes by accounting for the moisture transport effect, while also demonstrating the electric field distribution and volume loss density. Model validation was carried out by experimental tests, and the absolute mean error was found to be 3.55 and 5.73 °C for 210 and 350W power levels, respectively. To reach more precise solutions, the thermophysical and dielectric properties of tomatoes were assumed to be temperature dependent. To explore drying kinetics and moisture transport in microwave drying, experimental results of tomato slices (5 mm thick) dried at 210 and 350W power are compared with four models, including three thin-layer drying models (Henderson–Pabis, Page, and Wang & Singh) and Fick’s diffusion model. The Page and Wang Sing model was found to be in outstanding consensus with the empirical data in microwave drying process. The reasons for the poorer fit of the Fick model compared to the other models were explained. In addition, the difficulties of microwave dehydration CFD modeling and future recommendations were explained in detail. The findings and frameworks presented herein offer substantial knowledge that may broaden the investigative horizons of researchers within this subject.
- 14 May 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 151 (9) , 8131-8150
Open AccessNumerical analysis and transient thermal modeling of microwave dehydration of tomato: validation with experimental results
In this study, a model of microwave dehydration of tomato slices was created. The model illustrates the temperature variations during the microwave dehydration of tomatoes by accounting for the moisture transport effect, while also demonstrating the electric field distribution and volume loss density. Model validation was carried out by experimental tests, and the absolute mean error was found to be 3.55 and 5.73 °C for 210 and 350W power levels, respectively. To reach more precise solutions, the thermophysical and dielectric properties of tomatoes were assumed to be temperature dependent. To explore drying kinetics and moisture transport in microwave drying, experimental results of tomato slices (5 mm thick) dried at 210 and 350W power are compared with four models, including three thin-layer drying models (Henderson–Pabis, Page, and Wang & Singh) and Fick’s diffusion model. The Page and Wang Sing model was found to be in outstanding consensus with the empirical data in microwave drying process. The reasons for the poorer fit of the Fick model compared to the other models were explained. In addition, the difficulties of microwave dehydration CFD modeling and future recommendations were explained in detail. The findings and frameworks presented herein offer substantial knowledge that may broaden the investigative horizons of researchers within this subject.
- Open Access
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- Vol. 30 (5 Part B) , 3753-3766
Experimental validation and optimization of PLC-controlled hybrid solar-diesel heating systems in extreme high-altitude climates
Integrating renewable energy technologies in severe environments presents formidable operational and thermodynamic challenges. This study investigates the performance of a large-scale hybrid solar-diesel heating system for a facility in Van, Turkiye, characterized by an extreme altitude of 2,300 m and a design outdoor temperature of –27°C. The research quantifies the thermodynamic efficiency gains of transitioning from conventional manual operation to a programmable logic controller (PLC) based automated cascade control regime. A high-fidelity digital twin model was validated against a continuous 20-day spring transition window (April 23-May 13, 2026) using empirical supervisory control and data acquisition temperature logs recorded at 15 minutes intervals. Statistical validation confirmed model reliability with a mean bias error of 7.34% and a coefficient of variation of the root mean square error of 8.26%, strictly adhering to international building energy modeling calibration standards. The automated differential cascade control effectively eliminated human operational errors and inefficient boiler short-cycling. Transitioning to full automation achieved a weather-normalized reduction of 53.7% in monthly diesel fuel consumption and mitigated approximately 5.35 tons of \mathrm{CO_2} CO2 equivalent emissions per month. This research establishes a highly reproducible validation framework for hybrid industrial facilities operating under severe environmental and instrumentation constraints.
- 1 January 2026
- Published by National Library of Serbia in Thermal Science
- Vol. 30 (5 Part B) , 3753-3766
Open AccessExperimental validation and optimization of PLC-controlled hybrid solar-diesel heating systems in extreme high-altitude climates
Integrating renewable energy technologies in severe environments presents formidable operational and thermodynamic challenges. This study investigates the performance of a large-scale hybrid solar-diesel heating system for a facility in Van, Turkiye, characterized by an extreme altitude of 2,300 m and a design outdoor temperature of –27°C. The research quantifies the thermodynamic efficiency gains of transitioning from conventional manual operation to a programmable logic controller (PLC) based automated cascade control regime. A high-fidelity digital twin model was validated against a continuous 20-day spring transition window (April 23-May 13, 2026) using empirical supervisory control and data acquisition temperature logs recorded at 15 minutes intervals. Statistical validation confirmed model reliability with a mean bias error of 7.34% and a coefficient of variation of the root mean square error of 8.26%, strictly adhering to international building energy modeling calibration standards. The automated differential cascade control effectively eliminated human operational errors and inefficient boiler short-cycling. Transitioning to full automation achieved a weather-normalized reduction of 53.7% in monthly diesel fuel consumption and mitigated approximately 5.35 tons of \mathrm{CO_2} CO2 equivalent emissions per month. This research establishes a highly reproducible validation framework for hybrid industrial facilities operating under severe environmental and instrumentation constraints.
- 27 November 2025
- Published by ASME International in Journal of Fluids Engineering
- Vol. 148 (3)
Evaluation of the Spalart–Allmaras and k – ω GEKO Turbulence Models Relative to k – ω Shear Stress Transport for Centrifugal Pump Simulations With Experimental Validation
This study examines the efficacy of the Spalart–Allmaras and k–ω Generalized k-ω (GEKO) turbulence models in modeling centrifugal pumps in comparison to the commonly utilized k–ω shear stress transport (SST) model. To guarantee precision and reliability, numerical simulations were conducted utilizing computational fluid dynamics (CFD), and the results were juxtaposed with experimental data. The research is segmented into two phases. The initial phase involves numerical experimentation utilizing the pump's computer-aided design models, succeeded by simulations of various flow circumstances employing all three turbulence models. The subsequent step involves laboratory validation, wherein prototypes are tested under identical settings to assess the correlation between numerical predictions and experimental outcomes. The assessment emphasizes essential performance indicators, including velocity and pressure distributions, pump efficiency, and computational duration. The results indicate that the k–ω GEKO and k–ω SST models yield similar conclusions, albeit with differing levels of accuracy depending on the flowrate. At high flow rates, the Spalart–Allmaras model demonstrates the lowest error of 2.71%, succeeded by k–ω SST at 14.74%, and k–ω GEKO at 15.64%. At low flow rates, the k–ω SST model has the maximum accuracy with a 4.08% error, closely succeeded by the Spalart–Allmaras model at 4.57%, but the k–ω GEKO model displays a higher inaccuracy of 6.20%. Furthermore, the Spalart–Allmaras model functions with almost twice the computing efficiency of both GEKO and SST. This study underscores the importance of selecting an appropriate turbulence model, offering valuable insights for engineers and academics engaged in pump design and optimization. These findings highlight the significant impact of turbulence model selection on the accuracy and computational cost of centrifugal pump simulations.
- 27 November 2025
- Published by ASME International in Journal of Fluids Engineering
- Vol. 148 (3)
Evaluation of the Spalart–Allmaras and k – ω GEKO Turbulence Models Relative to k – ω Shear Stress Transport for Centrifugal Pump Simulations With Experimental Validation
This study examines the efficacy of the Spalart–Allmaras and k–ω Generalized k-ω (GEKO) turbulence models in modeling centrifugal pumps in comparison to the commonly utilized k–ω shear stress transport (SST) model. To guarantee precision and reliability, numerical simulations were conducted utilizing computational fluid dynamics (CFD), and the results were juxtaposed with experimental data. The research is segmented into two phases. The initial phase involves numerical experimentation utilizing the pump's computer-aided design models, succeeded by simulations of various flow circumstances employing all three turbulence models. The subsequent step involves laboratory validation, wherein prototypes are tested under identical settings to assess the correlation between numerical predictions and experimental outcomes. The assessment emphasizes essential performance indicators, including velocity and pressure distributions, pump efficiency, and computational duration. The results indicate that the k–ω GEKO and k–ω SST models yield similar conclusions, albeit with differing levels of accuracy depending on the flowrate. At high flow rates, the Spalart–Allmaras model demonstrates the lowest error of 2.71%, succeeded by k–ω SST at 14.74%, and k–ω GEKO at 15.64%. At low flow rates, the k–ω SST model has the maximum accuracy with a 4.08% error, closely succeeded by the Spalart–Allmaras model at 4.57%, but the k–ω GEKO model displays a higher inaccuracy of 6.20%. Furthermore, the Spalart–Allmaras model functions with almost twice the computing efficiency of both GEKO and SST. This study underscores the importance of selecting an appropriate turbulence model, offering valuable insights for engineers and academics engaged in pump design and optimization. These findings highlight the significant impact of turbulence model selection on the accuracy and computational cost of centrifugal pump simulations.
- 9 November 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (24) , 20117-20136
Numerical and experimental design of a fuel heat exchanger for unmanned aerial vehicles, fabricable by additive manufacturing to enhance performance and mass efficiency
- 9 November 2025
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (24) , 20117-20136
Numerical and experimental design of a fuel heat exchanger for unmanned aerial vehicles, fabricable by additive manufacturing to enhance performance and mass efficiency
- 30 October 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 282
A second-law analysis-based analytical method for insulation thickness optimization in a space with constant insulation volume
- 30 October 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 282
A second-law analysis-based analytical method for insulation thickness optimization in a space with constant insulation volume
- 16 October 2024
- Published by Springer Nature in Food and Bioprocess Technology
- p. 1-28
Exploring Mathematical Modeling and CFD in Convective Drying of Fruits and Vegetables: A Review
- 16 October 2024
- Published by Springer Nature in Food and Bioprocess Technology
- p. 1-28
Exploring Mathematical Modeling and CFD in Convective Drying of Fruits and Vegetables: A Review
- 2 May 2024
- Published by Taylor & Francis in Numerical Heat Transfer, Part A: Applications
- Vol. 86 (19) , 6785-6807
Numerical modeling and experimental validation of air-side forced convection on a Wire-on-tube condenser for a domestic refrigerator
- 2 May 2024
- Published by Taylor & Francis in Numerical Heat Transfer, Part A: Applications
- Vol. 86 (19) , 6785-6807
Numerical modeling and experimental validation of air-side forced convection on a Wire-on-tube condenser for a domestic refrigerator
- Open Access
- 29 February 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 55
Numerical analysis of the heat transfer and pressure drop of a wavy fin and Kammtail tube condenser: An investigative study
- 29 February 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 55
Open AccessNumerical analysis of the heat transfer and pressure drop of a wavy fin and Kammtail tube condenser: An investigative study
- Open Access
- 30 November 2023
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 39 (2) , 1017-1028
Yapay sinir ağları yöntemiyle İstanbul ili doğal gaz tüketiminin tahmini ve şehir giriş istasyonlarının planlanması
Bu çalışmada, Yapay Sinir Ağları kullanılarak İstanbul Asya yakası ve Avrupa yakası için günlük ve saatlik doğal gaz talep tahmin modelleri oluşturulmuştur. Doğal gaz kullanımını etkileyen parametreler; tüketici sayısı, ortalama günlük sıcaklık, minimum günlük sıcaklık, resmî tatiller, ısıtma derece gün sayısı olarak belirlenmiştir. 2008'den 2018'in sonuna kadar elde edilen veriler kullanılarak MATLAB yazılımı ile talep tahmin modelleri oluşturulmuş ve İstanbul’da son yüzyıl içerisinde yaşanmış en soğuk gün olan 9 Şubat 1929 günlük en düşük -16oC ve günlük ortalama -7oC sıcaklık değerlerine göre 2027 yılına kadar doğal gaz talebi tahmini yapılmıştır. Bu çalışma neticesinde, doğal gaz talep tahmini ile hangi yıl doğal gaz şehir giriş istasyonunun kurulacağına karar verilmektedir. Doğal gaz dağıtım şirketi tarafından bakıldığında, doğru tahmin yapılabilirliği sistemde oluşabilecek hataları azaltır ve gaz dağıtım planlamasını daha isabetli olanak sağlar. Bu şekilde, gaz sistemleri çok daha gerçekçi ve karlı hale gelir. Müşteri tarafından bakıldığında ise doğru tahmin değerleri, sistemde oluşabilecek hataları azaltacağı için bu da müşterilerin gazsız kalma olasılığını minimize eder. Ayrıca, Synergi Gas yazılımı ile İstanbul Asya ve Avrupa bölgelerinde yer alan dağıtım ağının hız ve basınç kriterleri dikkate alınarak, talep tahminine dayalı olası kötü senaryolar için doğal gaz şehir giriş istasyonlarının nereye kurulacağı öngörülmüştür. Elde edilen sonuçlara göre İstanbul Gaz Dağıtım A.Ş. tarafından doğal gaz şehir giriş istasyonları projelendirme çalışması yapılmıştır.
- 30 November 2023
- Published by Journal of the Faculty of Engineering and Architecture of Gazi University in Gazi Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi
- Vol. 39 (2) , 1017-1028
Open AccessYapay sinir ağları yöntemiyle İstanbul ili doğal gaz tüketiminin tahmini ve şehir giriş istasyonlarının planlanması
Bu çalışmada, Yapay Sinir Ağları kullanılarak İstanbul Asya yakası ve Avrupa yakası için günlük ve saatlik doğal gaz talep tahmin modelleri oluşturulmuştur. Doğal gaz kullanımını etkileyen parametreler; tüketici sayısı, ortalama günlük sıcaklık, minimum günlük sıcaklık, resmî tatiller, ısıtma derece gün sayısı olarak belirlenmiştir. 2008'den 2018'in sonuna kadar elde edilen veriler kullanılarak MATLAB yazılımı ile talep tahmin modelleri oluşturulmuş ve İstanbul’da son yüzyıl içerisinde yaşanmış en soğuk gün olan 9 Şubat 1929 günlük en düşük -16oC ve günlük ortalama -7oC sıcaklık değerlerine göre 2027 yılına kadar doğal gaz talebi tahmini yapılmıştır. Bu çalışma neticesinde, doğal gaz talep tahmini ile hangi yıl doğal gaz şehir giriş istasyonunun kurulacağına karar verilmektedir. Doğal gaz dağıtım şirketi tarafından bakıldığında, doğru tahmin yapılabilirliği sistemde oluşabilecek hataları azaltır ve gaz dağıtım planlamasını daha isabetli olanak sağlar. Bu şekilde, gaz sistemleri çok daha gerçekçi ve karlı hale gelir. Müşteri tarafından bakıldığında ise doğru tahmin değerleri, sistemde oluşabilecek hataları azaltacağı için bu da müşterilerin gazsız kalma olasılığını minimize eder. Ayrıca, Synergi Gas yazılımı ile İstanbul Asya ve Avrupa bölgelerinde yer alan dağıtım ağının hız ve basınç kriterleri dikkate alınarak, talep tahminine dayalı olası kötü senaryolar için doğal gaz şehir giriş istasyonlarının nereye kurulacağı öngörülmüştür. Elde edilen sonuçlara göre İstanbul Gaz Dağıtım A.Ş. tarafından doğal gaz şehir giriş istasyonları projelendirme çalışması yapılmıştır.
- 2 October 2023
- Published by Springer Nature
- p. 174-187
Fuzzy Logic Based Heating and Cooling Control in Buildings Using Intermittent Energy
- 2 October 2023
- Published by Springer Nature
- p. 174-187
Fuzzy Logic Based Heating and Cooling Control in Buildings Using Intermittent Energy