Adam Williamson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Adam Williamson has a total of 243 co-authors. Here are the top co-authors by number of shared publications:
Emma Acerbo
Department of Neurosurgery, Emory University School of Medicine, Atlanta, GA, USA; Department of Neurology, Emory University School of Medicine, Atlanta, GA, USA
15 shared publicationsBoris Botzanowski
Institut de Neurosciences Des Systèmes (INS), UMR_1106, INSERM, Aix-Marseille Université, Marseille, France
13 shared publicationsFlorian Missey
International Clinical Research Center, St. Anne’s University Hospital Brno, Brno, Czechia
13 shared publicationsEsra Neufeld
Foundation for Research on Information Technologies in Society (IT'IS), Zurich, Switzerland
10 shared publications- George G. Malliaras
Department of Engineering, University of Cambridge, Cambridge, UK
10 shared publications Viktor Jirsa
Aix-Marseille Universite, Inserm, Institut de Neurosciences des Systemes (INS) UMR_S 1106, Marseille, France
10 shared publications
Latest Publications
- Open Access
- 8 October 2026
- Published by JMIR Publications Inc. in JMIR Mental Health
- Vol. 13, e98925
Ensemble of Domain-Specific Natural Language Processing and Large Language Models for Detecting Suicidal Ideation and Mental Health Conditions in Social Media Text: Development and Evaluation Study
Background: Mental illness contributes substantially to global disability, and public adoption of AI for mental health support is accelerating without commensurate safety evaluation. General-purpose large language models can fail to recognize naturalistic text expressing suicidal ideation, with immediate clinical consequences. Domain-specific natural language processing methods offer a contrasting approach, but ensembles integrating the two have not been formally characterized. Objective: We aimed to (1) benchmark 5 modeling approaches for classifying mental health–related social media text, (2) develop and optimize ensembles integrating a domain-specific natural language processing classifier with a fine-tuned large language model, and (3) derive a closed-form framework constraining ensemble weighting in safety-critical classification. Methods: We analyzed 60,889 publicly available Reddit and Twitter texts spanning 9 categories (anxiety, bipolar disorder, depression, a normal baseline, personality disorder, stress, suicidal ideation, attention-deficit/hyperactivity disorder, and autism spectrum disorder). Labels were derived from the originating subreddit or a self-stated condition and are not clinical diagnoses. Five architectures were compared: prompt-engineered base GPT-4o-mini; fine-tuned GPT-4o-mini; a domain-specific classifier (support vector machine over symptom-informed lexical features); and 2 ensembles of these models, hybrid probability–indicator fusion and soft probability fusion. Data were split into 70%, 10%, and 20% at the post level (n=42,622, n=6089, and n=12,178); weights were selected on the validation split and all reported performance comes from the held-out test split. Closed-form bounds on permissible language model weights were derived for both strategies. CIs are paired bootstrap intervals (n=10,000 replicates); accuracy differences were tested with exact McNemar tests. Results: The domain-specific classifier achieved 91.9% accuracy (95% CI 91.4%-92.4%), exceeding the base (58.7%) and fine-tuned (88.6%) large language models. Both ensembles outperformed either constituent model, reaching 93.9% (soft fusion; 95% CI 93.5%-94.3%) and 93.8% (hybrid fusion; 95% CI 93.4%-94.2%) at a weighting of 60% classifier to 40% fine-tuned model, selected on validation (P<.001 for both against the classifier alone; the 2 ensembles did not differ from each other [P=.16]). The hybrid ensemble reduced the miss rate for the suicidal ideation category from 32.5% (650/2000) to 1.9% (37/2000), a 17.6-fold reduction relative to the base model, although its advantage over the classifier alone within that category was not significant (P=.68). Accuracy fell discontinuously above a 50% language model weight, where the hybrid ensemble reduced exactly to the fine-tuned model; the selected weight satisfies the derived instance-level bound of 44.0%. Conclusions: Domain-specific clinical grounding remained necessary for stable ensemble performance in this corpus, and probabilistic fusion outperformed both constituent models when language model weight was bounded by a derivable, model-agnostic constraint. Because labels were community-inferred and only one corpus was analyzed, these results are hypotheses requiring external validation on clinically characterized data before use in decision support.
- 8 October 2026
- Published by JMIR Publications Inc. in JMIR Mental Health
- Vol. 13, e98925
Open AccessEnsemble of Domain-Specific Natural Language Processing and Large Language Models for Detecting Suicidal Ideation and Mental Health Conditions in Social Media Text: Development and Evaluation Study
Background: Mental illness contributes substantially to global disability, and public adoption of AI for mental health support is accelerating without commensurate safety evaluation. General-purpose large language models can fail to recognize naturalistic text expressing suicidal ideation, with immediate clinical consequences. Domain-specific natural language processing methods offer a contrasting approach, but ensembles integrating the two have not been formally characterized. Objective: We aimed to (1) benchmark 5 modeling approaches for classifying mental health–related social media text, (2) develop and optimize ensembles integrating a domain-specific natural language processing classifier with a fine-tuned large language model, and (3) derive a closed-form framework constraining ensemble weighting in safety-critical classification. Methods: We analyzed 60,889 publicly available Reddit and Twitter texts spanning 9 categories (anxiety, bipolar disorder, depression, a normal baseline, personality disorder, stress, suicidal ideation, attention-deficit/hyperactivity disorder, and autism spectrum disorder). Labels were derived from the originating subreddit or a self-stated condition and are not clinical diagnoses. Five architectures were compared: prompt-engineered base GPT-4o-mini; fine-tuned GPT-4o-mini; a domain-specific classifier (support vector machine over symptom-informed lexical features); and 2 ensembles of these models, hybrid probability–indicator fusion and soft probability fusion. Data were split into 70%, 10%, and 20% at the post level (n=42,622, n=6089, and n=12,178); weights were selected on the validation split and all reported performance comes from the held-out test split. Closed-form bounds on permissible language model weights were derived for both strategies. CIs are paired bootstrap intervals (n=10,000 replicates); accuracy differences were tested with exact McNemar tests. Results: The domain-specific classifier achieved 91.9% accuracy (95% CI 91.4%-92.4%), exceeding the base (58.7%) and fine-tuned (88.6%) large language models. Both ensembles outperformed either constituent model, reaching 93.9% (soft fusion; 95% CI 93.5%-94.3%) and 93.8% (hybrid fusion; 95% CI 93.4%-94.2%) at a weighting of 60% classifier to 40% fine-tuned model, selected on validation (P<.001 for both against the classifier alone; the 2 ensembles did not differ from each other [P=.16]). The hybrid ensemble reduced the miss rate for the suicidal ideation category from 32.5% (650/2000) to 1.9% (37/2000), a 17.6-fold reduction relative to the base model, although its advantage over the classifier alone within that category was not significant (P=.68). Accuracy fell discontinuously above a 50% language model weight, where the hybrid ensemble reduced exactly to the fine-tuned model; the selected weight satisfies the derived instance-level bound of 44.0%. Conclusions: Domain-specific clinical grounding remained necessary for stable ensemble performance in this corpus, and probabilistic fusion outperformed both constituent models when language model weight was bounded by a derivable, model-agnostic constraint. Because labels were community-inferred and only one corpus was analyzed, these results are hypotheses requiring external validation on clinically characterized data before use in decision support.
- Open Access
- 1 July 2026
- Published by Springer Nature in Communications Medicine
- Vol. 6 (1)
Enhancement of sleep slow wave activity using transcranial electrical stimulation with temporal interference: an interim analysis of the STRENGTHEN study
Background: Slow waves are oscillations that reflect rhythmic alternation of neuronal activity and mediate key restorative functions of non-rapid eye movement (NREM) sleep. Left ventromedial prefrontal cortex regions are a “hot spot” for slow wave generation. The enhancement of slow wave activity (SWA, 0.5-4 Hz) has been shown to be beneficial, as in improving memory performance. To overcome limitations of current techniques, we assessed the ability of a non-invasive neuromodulatory tool, Transcranial Electrical Stimulation with Temporal Interference (TES-TI), to enhance SWA during NREM sleep overnight in healthy humans. Methods: The current study is an interim analysis focused on the effects of TES-TI during NREM sleep in a laboratory setting. Two high frequency carriers with 1 Hz difference (TES 15kHz -TI 1Hz ) produced amplitude-modulated temporal interference at 1Hz. Data were collected at the University of Wisconsin-Madison as part of the STRENGTHEN study (ClinicalTrials.gov, NCT06267521, 02/12/2024, single-blind, non-random allocation). Eligible participants were healthy adults (ages 18–50) assigned in parallel to one of four groups: (Group 1) TES 15kHz (0 Hz difference frequency) 2 nights per week and meditation; (Group 2) TES 15kHz -TI 1Hz (1 Hz difference frequency) 2 nights per week and sham meditation; (Group 3) TES 15kHz -TI 1Hz 1 night per week and meditation; (Group 4) TES 15kHz -TI 1Hz 2 nights per week and meditation. Stimulation targeting left ventromedial prefrontal cortex occurred during NREM sleep over repeated nights ( ~ 10 stimulation periods, 3-min each, first half of night, 1-2 nights/week, 4-week protocol). Twenty-one participants (Groups 2, 3, 4) received TES 15kHz -TI 1Hz and seven participants received TES 15kHz (Group 1). SWA was measured using simultaneous high-density electroencephalography with polysomnography. Results: We show that SWA is increased with TES 15kHz -TI 1Hz ( N = 21 total; N = 5 Group 2, N = 10 Group 3, N = 6 Group 4), and the effect outlasts the stimulation period; higher frequencies (sigma and beta) decrease. During stimulation, SWA is greater in TES 15kHz -TI 1Hz than pure TES 15kHz ( N = 7 Group 1). The incremental effects of TES 15kHz -TI 1Hz on SWA between first and last intervention night are positively associated with subjective ratings of restorative sleep. Conclusions: To our knowledge, this is the first study demonstrating that TES-TI enhances SWA and potentially its restorative function.
- 1 July 2026
- Published by Springer Nature in Communications Medicine
- Vol. 6 (1)
Open AccessEnhancement of sleep slow wave activity using transcranial electrical stimulation with temporal interference: an interim analysis of the STRENGTHEN study
Background: Slow waves are oscillations that reflect rhythmic alternation of neuronal activity and mediate key restorative functions of non-rapid eye movement (NREM) sleep. Left ventromedial prefrontal cortex regions are a “hot spot” for slow wave generation. The enhancement of slow wave activity (SWA, 0.5-4 Hz) has been shown to be beneficial, as in improving memory performance. To overcome limitations of current techniques, we assessed the ability of a non-invasive neuromodulatory tool, Transcranial Electrical Stimulation with Temporal Interference (TES-TI), to enhance SWA during NREM sleep overnight in healthy humans. Methods: The current study is an interim analysis focused on the effects of TES-TI during NREM sleep in a laboratory setting. Two high frequency carriers with 1 Hz difference (TES 15kHz -TI 1Hz ) produced amplitude-modulated temporal interference at 1Hz. Data were collected at the University of Wisconsin-Madison as part of the STRENGTHEN study (ClinicalTrials.gov, NCT06267521, 02/12/2024, single-blind, non-random allocation). Eligible participants were healthy adults (ages 18–50) assigned in parallel to one of four groups: (Group 1) TES 15kHz (0 Hz difference frequency) 2 nights per week and meditation; (Group 2) TES 15kHz -TI 1Hz (1 Hz difference frequency) 2 nights per week and sham meditation; (Group 3) TES 15kHz -TI 1Hz 1 night per week and meditation; (Group 4) TES 15kHz -TI 1Hz 2 nights per week and meditation. Stimulation targeting left ventromedial prefrontal cortex occurred during NREM sleep over repeated nights ( ~ 10 stimulation periods, 3-min each, first half of night, 1-2 nights/week, 4-week protocol). Twenty-one participants (Groups 2, 3, 4) received TES 15kHz -TI 1Hz and seven participants received TES 15kHz (Group 1). SWA was measured using simultaneous high-density electroencephalography with polysomnography. Results: We show that SWA is increased with TES 15kHz -TI 1Hz ( N = 21 total; N = 5 Group 2, N = 10 Group 3, N = 6 Group 4), and the effect outlasts the stimulation period; higher frequencies (sigma and beta) decrease. During stimulation, SWA is greater in TES 15kHz -TI 1Hz than pure TES 15kHz ( N = 7 Group 1). The incremental effects of TES 15kHz -TI 1Hz on SWA between first and last intervention night are positively associated with subjective ratings of restorative sleep. Conclusions: To our knowledge, this is the first study demonstrating that TES-TI enhances SWA and potentially its restorative function.
- Open Access
- 21 April 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Ensemble of Domain-Specific Natural Language Processing and Large Language Models for Detecting Suicidal Ideation and Mental Health Conditions in Social Media Text: Development and Evaluation Study (Preprint)
BACKGROUND Mental illness contributes substantially to global disability, and public adoption of AI for mental health support is accelerating without commensurate safety evaluation. General-purpose large language models can fail to recognize naturalistic text expressing suicidal ideation, with immediate clinical consequences. Domain-specific natural language processing methods offer a contrasting approach, but ensembles integrating the two have not been formally characterized. OBJECTIVE We aimed to (1) benchmark 5 modeling approaches for classifying mental health–related social media text, (2) develop and optimize ensembles integrating a domain-specific natural language processing classifier with a fine-tuned large language model, and (3) derive a closed-form framework constraining ensemble weighting in safety-critical classification. METHODS We analyzed 60,889 publicly available Reddit and Twitter texts spanning 9 categories (anxiety, bipolar disorder, depression, a normal baseline, personality disorder, stress, suicidal ideation, attention-deficit/hyperactivity disorder, and autism spectrum disorder). Labels were derived from the originating subreddit or a self-stated condition and are not clinical diagnoses. Five architectures were compared: prompt-engineered base GPT-4o-mini; fine-tuned GPT-4o-mini; a domain-specific classifier (support vector machine over symptom-informed lexical features); and 2 ensembles of these models, hybrid probability–indicator fusion and soft probability fusion. Data were split into 70%, 10%, and 20% at the post level (n=42,622, n=6089, and n=12,178); weights were selected on the validation split and all reported performance comes from the held-out test split. Closed-form bounds on permissible language model weights were derived for both strategies. CIs are paired bootstrap intervals (n=10,000 replicates); accuracy differences were tested with exact McNemar tests. RESULTS The domain-specific classifier achieved 91.9% accuracy (95% CI 91.4%-92.4%), exceeding the base (58.7%) and fine-tuned (88.6%) large language models. Both ensembles outperformed either constituent model, reaching 93.9% (soft fusion; 95% CI 93.5%-94.3%) and 93.8% (hybrid fusion; 95% CI 93.4%-94.2%) at a weighting of 60% classifier to 40% fine-tuned model, selected on validation (P<.001 for both against the classifier alone; the 2 ensembles did not differ from each other [P=.16]). The hybrid ensemble reduced the miss rate for the suicidal ideation category from 32.5% (650/2000) to 1.9% (37/2000), a 17.6-fold reduction relative to the base model, although its advantage over the classifier alone within that category was not significant (P=.68). Accuracy fell discontinuously above a 50% language model weight, where the hybrid ensemble reduced exactly to the fine-tuned model; the selected weight satisfies the derived instance-level bound of 44.0%. CONCLUSIONS Domain-specific clinical grounding remained necessary for stable ensemble performance in this corpus, and probabilistic fusion outperformed both constituent models when language model weight was bounded by a derivable, model-agnostic constraint. Because labels were community-inferred and only one corpus was analyzed, these results are hypotheses requiring external validation on clinically characterized data before use in decision support.
- 21 April 2026
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessEnsemble of Domain-Specific Natural Language Processing and Large Language Models for Detecting Suicidal Ideation and Mental Health Conditions in Social Media Text: Development and Evaluation Study (Preprint)
BACKGROUND Mental illness contributes substantially to global disability, and public adoption of AI for mental health support is accelerating without commensurate safety evaluation. General-purpose large language models can fail to recognize naturalistic text expressing suicidal ideation, with immediate clinical consequences. Domain-specific natural language processing methods offer a contrasting approach, but ensembles integrating the two have not been formally characterized. OBJECTIVE We aimed to (1) benchmark 5 modeling approaches for classifying mental health–related social media text, (2) develop and optimize ensembles integrating a domain-specific natural language processing classifier with a fine-tuned large language model, and (3) derive a closed-form framework constraining ensemble weighting in safety-critical classification. METHODS We analyzed 60,889 publicly available Reddit and Twitter texts spanning 9 categories (anxiety, bipolar disorder, depression, a normal baseline, personality disorder, stress, suicidal ideation, attention-deficit/hyperactivity disorder, and autism spectrum disorder). Labels were derived from the originating subreddit or a self-stated condition and are not clinical diagnoses. Five architectures were compared: prompt-engineered base GPT-4o-mini; fine-tuned GPT-4o-mini; a domain-specific classifier (support vector machine over symptom-informed lexical features); and 2 ensembles of these models, hybrid probability–indicator fusion and soft probability fusion. Data were split into 70%, 10%, and 20% at the post level (n=42,622, n=6089, and n=12,178); weights were selected on the validation split and all reported performance comes from the held-out test split. Closed-form bounds on permissible language model weights were derived for both strategies. CIs are paired bootstrap intervals (n=10,000 replicates); accuracy differences were tested with exact McNemar tests. RESULTS The domain-specific classifier achieved 91.9% accuracy (95% CI 91.4%-92.4%), exceeding the base (58.7%) and fine-tuned (88.6%) large language models. Both ensembles outperformed either constituent model, reaching 93.9% (soft fusion; 95% CI 93.5%-94.3%) and 93.8% (hybrid fusion; 95% CI 93.4%-94.2%) at a weighting of 60% classifier to 40% fine-tuned model, selected on validation (P<.001 for both against the classifier alone; the 2 ensembles did not differ from each other [P=.16]). The hybrid ensemble reduced the miss rate for the suicidal ideation category from 32.5% (650/2000) to 1.9% (37/2000), a 17.6-fold reduction relative to the base model, although its advantage over the classifier alone within that category was not significant (P=.68). Accuracy fell discontinuously above a 50% language model weight, where the hybrid ensemble reduced exactly to the fine-tuned model; the selected weight satisfies the derived instance-level bound of 44.0%. CONCLUSIONS Domain-specific clinical grounding remained necessary for stable ensemble performance in this corpus, and probabilistic fusion outperformed both constituent models when language model weight was bounded by a derivable, model-agnostic constraint. Because labels were community-inferred and only one corpus was analyzed, these results are hypotheses requiring external validation on clinically characterized data before use in decision support.
- Top Cited PapersOpen Access
- 13 November 2025
- Published by Elsevier in Brain Stimulation
- Vol. 19 (1) , 102981
Non-invasive temporal interference stimulation of the hippocampus suppresses epileptic biomarkers in patients with Epilepsy: biophysical differences between kilohertz and amplitude modulated stimulation
- 13 November 2025
- Published by Elsevier in Brain Stimulation
- Vol. 19 (1) , 102981
Top Cited PapersOpen AccessNon-invasive temporal interference stimulation of the hippocampus suppresses epileptic biomarkers in patients with Epilepsy: biophysical differences between kilohertz and amplitude modulated stimulation
- Open Access
Enhancement of Sleep Slow Wave Activity using Transcranial Electrical Stimulation with Temporal Interference
Slow waves mediate restorative functions of non-rapid eye movement (NREM) sleep. To enhance slow wave activity (SWA, 0.5-4 Hz) non-invasively, we employed a novel neuromodulatory tool, Transcranial Electrical Stimulation with Temporal Interference (TES-TI). Healthy participants (n=21) received TES-TI during NREM sleep over several nights (∼10 stimulation periods, 3min each, first half of night, 4-week protocol), targeting left ventromedial prefrontal cortex—a “hot spot” of slow wave generation. Two high frequency carriers with 1Hz difference (TES 15kHz -TI 1Hz ) produced amplitude modulated temporal interference at 1Hz. SWA, measured with simultaneous high-density electroencephalography (hd-EEG), was increased by TES 15kHz -TI 1Hz , with the effect outlasting the stimulation period. Higher frequencies (sigma and beta) decreased. Pure TES 15kHz did not have comparable effects. The incremental effects of TES 15kHz -TI 1Hz on SWA between first and last intervention night were positively correlated with subjective ratings of restorative sleep. This is the first study demonstrating that TES-TI can enhance sleep and its restorative function.
Open AccessEnhancement of Sleep Slow Wave Activity using Transcranial Electrical Stimulation with Temporal Interference
Slow waves mediate restorative functions of non-rapid eye movement (NREM) sleep. To enhance slow wave activity (SWA, 0.5-4 Hz) non-invasively, we employed a novel neuromodulatory tool, Transcranial Electrical Stimulation with Temporal Interference (TES-TI). Healthy participants (n=21) received TES-TI during NREM sleep over several nights (∼10 stimulation periods, 3min each, first half of night, 4-week protocol), targeting left ventromedial prefrontal cortex—a “hot spot” of slow wave generation. Two high frequency carriers with 1Hz difference (TES 15kHz -TI 1Hz ) produced amplitude modulated temporal interference at 1Hz. SWA, measured with simultaneous high-density electroencephalography (hd-EEG), was increased by TES 15kHz -TI 1Hz , with the effect outlasting the stimulation period. Higher frequencies (sigma and beta) decreased. Pure TES 15kHz did not have comparable effects. The incremental effects of TES 15kHz -TI 1Hz on SWA between first and last intervention night were positively correlated with subjective ratings of restorative sleep. This is the first study demonstrating that TES-TI can enhance sleep and its restorative function.
- Top Cited PapersOpen Access
- 9 April 2025
- Published by Wiley in Movement Disorders
- Vol. 40 (6) , 1051-1060
Noninvasive Temporal Interference Stimulation of the Subthalamic Nucleus in Parkinson's Disease Reduces Beta Activity
Background: Temporal interference stimulation (TIS) is a novel noninvasive electrical stimulation technique to focally modulate deep brain regions; a minimum of two high‐frequency signals (f1 and f2 > 1 kHz) interfere to create an envelope‐modulated signal at a deep brain target with the frequency of modulation equal to the difference frequency: Δf = |f2 – f1|.Objective: The goals of this study were to verify the capability of TIS to modulate the subthalamic nucleus (STN) with Δf and to compare the effect of TIS and conventional deep brain stimulation (DBS) on the STN beta oscillations in patients with Parkinson's disease (PD).Methods: DBS leads remained externalized after implantation, allowing local field potentials (LFPs) recordings in eight patients with PD. TIS was performed initially by two pairs (f1 = 9.00 kHz; f2 = 9.13 kHz, 4 mA peak‐peak per pair maximum) of scalp electrodes placed in temporoparietal regions to focus the envelope signal maximum (Δf = 130 Hz) at the motor part of the STN target.Results: The comparison between the baseline LFPs and recordings after TIS and conventional DBS sessions showed substantial suppression of high beta power peak after both types of stimulation in all patients.Conclusions: TIS has the potential to effectively modulate the STN and reduce the beta oscillatory activity in a completely noninvasive manner, as is traditionally possible only with intracranial DBS. Future studies should confirm the clinical effectiveness of TIS and determine whether TIS could be used to identify optimal DBS candidates and individualize DBS targets. © 2025 The Author(s). Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.
- 9 April 2025
- Published by Wiley in Movement Disorders
- Vol. 40 (6) , 1051-1060
Top Cited PapersOpen AccessNoninvasive Temporal Interference Stimulation of the Subthalamic Nucleus in Parkinson's Disease Reduces Beta Activity
Background: Temporal interference stimulation (TIS) is a novel noninvasive electrical stimulation technique to focally modulate deep brain regions; a minimum of two high‐frequency signals (f1 and f2 > 1 kHz) interfere to create an envelope‐modulated signal at a deep brain target with the frequency of modulation equal to the difference frequency: Δf = |f2 – f1|.Objective: The goals of this study were to verify the capability of TIS to modulate the subthalamic nucleus (STN) with Δf and to compare the effect of TIS and conventional deep brain stimulation (DBS) on the STN beta oscillations in patients with Parkinson's disease (PD).Methods: DBS leads remained externalized after implantation, allowing local field potentials (LFPs) recordings in eight patients with PD. TIS was performed initially by two pairs (f1 = 9.00 kHz; f2 = 9.13 kHz, 4 mA peak‐peak per pair maximum) of scalp electrodes placed in temporoparietal regions to focus the envelope signal maximum (Δf = 130 Hz) at the motor part of the STN target.Results: The comparison between the baseline LFPs and recordings after TIS and conventional DBS sessions showed substantial suppression of high beta power peak after both types of stimulation in all patients.Conclusions: TIS has the potential to effectively modulate the STN and reduce the beta oscillatory activity in a completely noninvasive manner, as is traditionally possible only with intracranial DBS. Future studies should confirm the clinical effectiveness of TIS and determine whether TIS could be used to identify optimal DBS candidates and individualize DBS targets. © 2025 The Author(s). Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.
- Top Cited PapersOpen Access
- 27 March 2025
- Published by Springer Nature in Bioelectronic Medicine
- Vol. 11 (1) , 1-15
Focal control of non-invasive deep brain stimulation using multipolar temporal interference
Temporal interference (TI) is a method of non-invasive brain stimulation using transcutaneous electrodes which allows the targeting and modulation of deeper brain structures, not normally associated with non-invasive simulation, while avoiding unwanted stimulation of shallower cortical structures. The properties of TI have been previously demonstrated, however, the problem of decoupling stimulation focality from stimulation intensity has not yet been well addressed. In this paper, we provide a possible novel solution, multipolar TI (mTI), which allows increased independent control over both the size of the stimulated region and the stimulation intensity. The mTI method uses multiple carrier frequencies to create multiple overlapping amplitude-modulated envelopes, rather than using one envelope as in standard TI. The study presents an explanation of the concept of mTI along with experimental data gathered from Rhesus macaques and mice. We improved the focality at depth in anesthetized mice and monkeys, and using the new focality in awake monkeys, evoked targeted activity at depth in the superior colliculus. The mTI method could be an interesting and potentially useful new tool alongside other forms of non-invasive brain stimulation. Teaser Multipolar Temporal Interference Stimulation can produce a more focal brain stimulation at depth compared to Temporal Interference.
- 27 March 2025
- Published by Springer Nature in Bioelectronic Medicine
- Vol. 11 (1) , 1-15
Top Cited PapersOpen AccessFocal control of non-invasive deep brain stimulation using multipolar temporal interference
Temporal interference (TI) is a method of non-invasive brain stimulation using transcutaneous electrodes which allows the targeting and modulation of deeper brain structures, not normally associated with non-invasive simulation, while avoiding unwanted stimulation of shallower cortical structures. The properties of TI have been previously demonstrated, however, the problem of decoupling stimulation focality from stimulation intensity has not yet been well addressed. In this paper, we provide a possible novel solution, multipolar TI (mTI), which allows increased independent control over both the size of the stimulated region and the stimulation intensity. The mTI method uses multiple carrier frequencies to create multiple overlapping amplitude-modulated envelopes, rather than using one envelope as in standard TI. The study presents an explanation of the concept of mTI along with experimental data gathered from Rhesus macaques and mice. We improved the focality at depth in anesthetized mice and monkeys, and using the new focality in awake monkeys, evoked targeted activity at depth in the superior colliculus. The mTI method could be an interesting and potentially useful new tool alongside other forms of non-invasive brain stimulation. Teaser Multipolar Temporal Interference Stimulation can produce a more focal brain stimulation at depth compared to Temporal Interference.
- Open Access
Non-invasive Temporal Interference Stimulation of the Hippocampus Suppresses Epileptic Biomarkers in Patients with Epilepsy: Biophysical Differences between Kilohertz and Amplitude Modulated Stimulation
Medication-refractory focal epilepsy creates a significant challenge, with approximately 30% of patients ineligible for surgery due to the involvement of eloquent cortex in the epileptogenic network. For such patients with limited surgical options, electrical neuromodulation represents a promising alternative therapy. In this study, we investigate the potential of non-invasive temporal interference (TI) electrical stimulation to reduce epileptic biomarkers in patients with epilepsy by comparing intracerebral recordings obtained before, during, and after TI stimulation, to recordings during low and high kHz frequency (HF) sham stimulation. Thirteen patients with symptoms of mesiotemporal epilepsy (MTLE) and implanted with stereoelectroencephalography (sEEG) depth electrodes received TI stimulation with an amplitude modulation (AM) frequency of 130Hz (Δf), where the AM was delivered with lower frequency kHz carriers (1kHz + 1.13kHz), or higher frequency carriers (9kHz + 9.13kHz), targeting the hippocampus – a common epileptic focus and consequently stimulation target in MTLE. Our results show that TI stimulation yields a statistically significant decrease in interictal epileptiform discharges (IEDs) and pathological high-frequency oscillations (HFOs) – specifically fast-ripples (FR) –, where the suppression is apparent in the hippocampal focus and propagation from the focus is reduced brain-wide. HF sham stimulation at 1kHz frequency also impacted the IED rate in the cortex, but without reaching the hippocampal focus. The HF sham effect diminished with increasing frequencies (2, 5, and 9kHz, respectively), specifically as a function of depth into the cortex. This depth dependence was not observed with the TI, independent of the employed carrier frequency (low or high kHz). Furthermore, a strong carry-over effect, i.e., suppression of epileptic biomarkers for a period of time after the end of stimulation, was observed for TI but not for kHz. Our findings underscore the possible application of TI in epilepsy, as an additional non-invasive brain stimulation tool, potentially offering opportunities to assess brain region response to electrical neuromodulation before committing to a deep brain stimulation (DBS) or responsive neurostimulation (RNS) implants. Our results further demonstrate distinct biophysical differences between kHz and focal AM stimulation. Graphical
Open AccessNon-invasive Temporal Interference Stimulation of the Hippocampus Suppresses Epileptic Biomarkers in Patients with Epilepsy: Biophysical Differences between Kilohertz and Amplitude Modulated Stimulation
Medication-refractory focal epilepsy creates a significant challenge, with approximately 30% of patients ineligible for surgery due to the involvement of eloquent cortex in the epileptogenic network. For such patients with limited surgical options, electrical neuromodulation represents a promising alternative therapy. In this study, we investigate the potential of non-invasive temporal interference (TI) electrical stimulation to reduce epileptic biomarkers in patients with epilepsy by comparing intracerebral recordings obtained before, during, and after TI stimulation, to recordings during low and high kHz frequency (HF) sham stimulation. Thirteen patients with symptoms of mesiotemporal epilepsy (MTLE) and implanted with stereoelectroencephalography (sEEG) depth electrodes received TI stimulation with an amplitude modulation (AM) frequency of 130Hz (Δf), where the AM was delivered with lower frequency kHz carriers (1kHz + 1.13kHz), or higher frequency carriers (9kHz + 9.13kHz), targeting the hippocampus – a common epileptic focus and consequently stimulation target in MTLE. Our results show that TI stimulation yields a statistically significant decrease in interictal epileptiform discharges (IEDs) and pathological high-frequency oscillations (HFOs) – specifically fast-ripples (FR) –, where the suppression is apparent in the hippocampal focus and propagation from the focus is reduced brain-wide. HF sham stimulation at 1kHz frequency also impacted the IED rate in the cortex, but without reaching the hippocampal focus. The HF sham effect diminished with increasing frequencies (2, 5, and 9kHz, respectively), specifically as a function of depth into the cortex. This depth dependence was not observed with the TI, independent of the employed carrier frequency (low or high kHz). Furthermore, a strong carry-over effect, i.e., suppression of epileptic biomarkers for a period of time after the end of stimulation, was observed for TI but not for kHz. Our findings underscore the possible application of TI in epilepsy, as an additional non-invasive brain stimulation tool, potentially offering opportunities to assess brain region response to electrical neuromodulation before committing to a deep brain stimulation (DBS) or responsive neurostimulation (RNS) implants. Our results further demonstrate distinct biophysical differences between kHz and focal AM stimulation. Graphical
- Open Access
- 4 September 2024
- Published by Springer Nature in Research Square
Virtual brain twins for stimulation in epilepsy
Estimating the epileptogenic zone network (EZN) is an important part of the diagnosis of drug-resistant focal epilepsy and plays a pivotal role in treatment and intervention. Virtual brain twins, based on personalized whole brain modeling, provide a formal method for personalized diagnosis and treatment. They integrate patient-specific brain topography with structural connectivity from anatomical neuroimaging such as MRI, and dynamic activity from functional recordings such as EEG and stereo-EEG (SEEG). Seizures demonstrate rich spatial and temporal features in functional recordings, which can be exploited to estimate the EZN. Stimulation-induced seizures can provide important and complementary information. We consider invasive SEEG stimulation as the most practical current approach, and temporal interference (TI) stimulation as a potential future approach for non-invasive diagnosis and treatment. This paper offers a virtual brain twin framework for EZN diagnosis based on stimulation-induced seizures. This framework estimates the EZN and validated the results on synthetic data with ground-truth. It provides an important methodological and conceptual basis for a series of ongoing scientific studies and clinical usage, which are specified in this paper. This framework also provides the necessary step to go from invasive to non-invasive diagnosis and treatment of drug-resistant focal epilepsy.
- 4 September 2024
- Published by Springer Nature in Research Square
Open AccessVirtual brain twins for stimulation in epilepsy
Estimating the epileptogenic zone network (EZN) is an important part of the diagnosis of drug-resistant focal epilepsy and plays a pivotal role in treatment and intervention. Virtual brain twins, based on personalized whole brain modeling, provide a formal method for personalized diagnosis and treatment. They integrate patient-specific brain topography with structural connectivity from anatomical neuroimaging such as MRI, and dynamic activity from functional recordings such as EEG and stereo-EEG (SEEG). Seizures demonstrate rich spatial and temporal features in functional recordings, which can be exploited to estimate the EZN. Stimulation-induced seizures can provide important and complementary information. We consider invasive SEEG stimulation as the most practical current approach, and temporal interference (TI) stimulation as a potential future approach for non-invasive diagnosis and treatment. This paper offers a virtual brain twin framework for EZN diagnosis based on stimulation-induced seizures. This framework estimates the EZN and validated the results on synthetic data with ground-truth. It provides an important methodological and conceptual basis for a series of ongoing scientific studies and clinical usage, which are specified in this paper. This framework also provides the necessary step to go from invasive to non-invasive diagnosis and treatment of drug-resistant focal epilepsy.
- Open Access
- 1 August 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (8) , 085109
NeuroRoots, a bio-inspired, seamless brain machine interface for long-term recording in delicate brain regions
Scalable electronic brain implants with long-term stability and low biological perturbation are crucial technologies for high-quality brain–machine interfaces that can seamlessly access delicate and hard-to-reach regions of the brain. Here, we created “NeuroRoots,” a biomimetic multi-channel implant with similar dimensions (7 μm wide and 1.5 μm thick), mechanical compliance, and spatial distribution as axons in the brain. Unlike planar shank implants, these devices consist of a number of individual electrode “roots,” each tendril independent from the other. A simple microscale delivery approach based on commercially available apparatus minimally perturbs existing neural architectures during surgery. NeuroRoots enables high density single unit recording from the cerebellum in vitro and in vivo. NeuroRoots also reliably recorded action potentials in various brain regions for at least 7 weeks during behavioral experiments in freely-moving rats, without adjustment of electrode position. This minimally invasive axon-like implant design is an important step toward improving the integration and stability of brain–machine interfacing.
- 1 August 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (8) , 085109
Open AccessNeuroRoots, a bio-inspired, seamless brain machine interface for long-term recording in delicate brain regions
Scalable electronic brain implants with long-term stability and low biological perturbation are crucial technologies for high-quality brain–machine interfaces that can seamlessly access delicate and hard-to-reach regions of the brain. Here, we created “NeuroRoots,” a biomimetic multi-channel implant with similar dimensions (7 μm wide and 1.5 μm thick), mechanical compliance, and spatial distribution as axons in the brain. Unlike planar shank implants, these devices consist of a number of individual electrode “roots,” each tendril independent from the other. A simple microscale delivery approach based on commercially available apparatus minimally perturbs existing neural architectures during surgery. NeuroRoots enables high density single unit recording from the cerebellum in vitro and in vivo. NeuroRoots also reliably recorded action potentials in various brain regions for at least 7 weeks during behavioral experiments in freely-moving rats, without adjustment of electrode position. This minimally invasive axon-like implant design is an important step toward improving the integration and stability of brain–machine interfacing.