Bin'EN Nie
Bin'EN Nie has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Bing Yue
Department of Bone and Joint Surgery Department of Orthopedics Renji Hospital Shanghai Jiaotong University School of Medicine Shanghai China
4 shared publications Teng Long
Department of Bone and Joint Surgery, Renji Hospital, Shanghai Jiaotong University School of Medicine, PR China
3 shared publicationsHui Li
Department of Bone and Joint Surgery, Renji Hospital, Shanghai Jiaotong University School of Medicine, PR China
2 shared publicationsShutao Zhang
Department of Bone and Joint Surgery, Renji Hospital, Shanghai Jiaotong University School of Medicine, PR China
2 shared publications- You Wang
Department of Bone and Joint Surgery, Renji Hospital, School of Medicine Shanghai Jiao Tong University Shanghai China
2 shared publications Bing Yue
Department of Bone and Joint Surgery
1 shared publication
Latest Publications
- 30 September 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 8 (44) , 10190-10204
KR-12 coating of polyetheretherketone (PEEK) surface via polydopamine improves osteointegration and antibacterial activity in vivo
Polyetheretherketone (PEEK) is considered to be a promising bone implant material owing to its biocompatibility and elastic modulus, which is similar to that of natural bone. However, the clinical potential of PEEK is severely limited by its bioinertness, which leads to poor osseointegration, and the lack of antibacterial properties. In this study, the antimicrobial peptide, KR-12, was immobilized on the surface of PEEK implants with the assistance of polydopamine (PDA) to inhibit bacterial infection as well as to promote osteogenesis and osseointegration. Compared to unmodified PEEK, the PEEK with immobilized KR-12 showed significantly improved antibacterial activity against Staphylococcus aureus (ATCC 25923), both in vitro and in vivo. For the in vitro and in vivo evaluation of the osteogenic properties of modified PEEK, rat bone mesenchymal stem cells (rBMSCs) and a rat femoral defect model were used, respectively. The in vitro studies showed that compared to rBMSCs treated with unmodified PEEK, those treated with KR-12-coated PEEK exhibited improved adhesion, proliferation, and osteogenic differentiation. Moreover, micro-computed tomography and histological analysis suggested that the KR-12 coating promoted osteointegration in vivo in rat femurs. Taken together, these results suggest that the KR-12 coating could improve the antibacterial ability of pure or PDA-coated PEEK against Staphylococcus aureus (ATCC 25923), both in vitro and in vivo. Overall, KR-12 combined with the PDA film coating synergistically induced osteogenic effects both in vitro and in vivo. Thus, the surface-modified material, which exhibits both anti-bacterial and osteointegration properties, shows considerable potential for use as an orthopedic implant.
- 30 September 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 8 (44) , 10190-10204
KR-12 coating of polyetheretherketone (PEEK) surface via polydopamine improves osteointegration and antibacterial activity in vivo
Polyetheretherketone (PEEK) is considered to be a promising bone implant material owing to its biocompatibility and elastic modulus, which is similar to that of natural bone. However, the clinical potential of PEEK is severely limited by its bioinertness, which leads to poor osseointegration, and the lack of antibacterial properties. In this study, the antimicrobial peptide, KR-12, was immobilized on the surface of PEEK implants with the assistance of polydopamine (PDA) to inhibit bacterial infection as well as to promote osteogenesis and osseointegration. Compared to unmodified PEEK, the PEEK with immobilized KR-12 showed significantly improved antibacterial activity against Staphylococcus aureus (ATCC 25923), both in vitro and in vivo. For the in vitro and in vivo evaluation of the osteogenic properties of modified PEEK, rat bone mesenchymal stem cells (rBMSCs) and a rat femoral defect model were used, respectively. The in vitro studies showed that compared to rBMSCs treated with unmodified PEEK, those treated with KR-12-coated PEEK exhibited improved adhesion, proliferation, and osteogenic differentiation. Moreover, micro-computed tomography and histological analysis suggested that the KR-12 coating promoted osteointegration in vivo in rat femurs. Taken together, these results suggest that the KR-12 coating could improve the antibacterial ability of pure or PDA-coated PEEK against Staphylococcus aureus (ATCC 25923), both in vitro and in vivo. Overall, KR-12 combined with the PDA film coating synergistically induced osteogenic effects both in vitro and in vivo. Thus, the surface-modified material, which exhibits both anti-bacterial and osteointegration properties, shows considerable potential for use as an orthopedic implant.
- Open Access
- 24 April 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (28) , 15547-15557
The antimicrobial peptide KR-12 promotes the osteogenic differentiation of human bone marrow stem cells by stimulating BMP/SMAD signaling
KR-12 is the smallest fragment of human antimicrobial peptide cathelicidin (LL-37), and could play key roles in the treatment of multiple infections, including osteomyelitis.
- 24 April 2018
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 8 (28) , 15547-15557
Open AccessThe antimicrobial peptide KR-12 promotes the osteogenic differentiation of human bone marrow stem cells by stimulating BMP/SMAD signaling
KR-12 is the smallest fragment of human antimicrobial peptide cathelicidin (LL-37), and could play key roles in the treatment of multiple infections, including osteomyelitis.
- Open Access
- 10 July 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (55) , 34321-34330
A comparative analysis of antibacterial properties and inflammatory responses for the KR-12 peptide on titanium and PEGylated titanium surfaces
Covalent immobilisation of antimicrobial peptides on titanium (Ti) surfaces has been widely performed to inhibit bacterial adhesion and biofilm formation, however, it is unclear whether a spacer is necessary in this process for anti-bacteria adhesion, while still exhibiting good biocompatibility. We investigated the antibacterial properties and inflammatory response of Ti and PEGylated Ti with covalently immobilized KR-12 peptide on the surfaces. The KR-12 peptide was derived from LL-37, which is bactericidal and bacteriostatic in solution. Successful covalent immobilisation was determined by X-ray photoelectron spectrometry, contact angle measurements, and atomic force microscopy. KR-12 incorporation significantly decreased the bacterial adhesion to the Ti surface. Compared to the Ti-KR-12, the KR-12 immobilisation via a PEG spacer increased anti-microbial efficiency and reduced in vitro adhesion and biofilm formation of Staphylococcus epidermidis. Activated macrophages deprived from THP-1 cells with long filopodia were observed on the titanium surface, which was in agreement with increased TNF-α and IL-1β secretion. The KR-12-modified Ti surface and PEGylated Ti surface significantly decreased TNF-α and IL-1β secretion and macrophages remained in inactivated round states. The grafting of a PEG spacer prior to KR-12 immobilisation on the Ti surface improved the antibacterial properties and reduced macrophage activation, and may also decrease overall inflammatory responses. Thus, this approach showed the potential to biofunctionalize Ti for anti-bacteria adhesion and reducing macrophage inflammation.
- 10 July 2017
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 7 (55) , 34321-34330
Open AccessA comparative analysis of antibacterial properties and inflammatory responses for the KR-12 peptide on titanium and PEGylated titanium surfaces
Covalent immobilisation of antimicrobial peptides on titanium (Ti) surfaces has been widely performed to inhibit bacterial adhesion and biofilm formation, however, it is unclear whether a spacer is necessary in this process for anti-bacteria adhesion, while still exhibiting good biocompatibility. We investigated the antibacterial properties and inflammatory response of Ti and PEGylated Ti with covalently immobilized KR-12 peptide on the surfaces. The KR-12 peptide was derived from LL-37, which is bactericidal and bacteriostatic in solution. Successful covalent immobilisation was determined by X-ray photoelectron spectrometry, contact angle measurements, and atomic force microscopy. KR-12 incorporation significantly decreased the bacterial adhesion to the Ti surface. Compared to the Ti-KR-12, the KR-12 immobilisation via a PEG spacer increased anti-microbial efficiency and reduced in vitro adhesion and biofilm formation of Staphylococcus epidermidis. Activated macrophages deprived from THP-1 cells with long filopodia were observed on the titanium surface, which was in agreement with increased TNF-α and IL-1β secretion. The KR-12-modified Ti surface and PEGylated Ti surface significantly decreased TNF-α and IL-1β secretion and macrophages remained in inactivated round states. The grafting of a PEG spacer prior to KR-12 immobilisation on the Ti surface improved the antibacterial properties and reduced macrophage activation, and may also decrease overall inflammatory responses. Thus, this approach showed the potential to biofunctionalize Ti for anti-bacteria adhesion and reducing macrophage inflammation.