Michael D. Diodato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael D. Diodato has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Anson M. Lee
Cardiothoracic Surgery, Cardiovascular Research Center, Stanford University, Palo Alto, CA (A.M.L.).
1 shared publication Dany Berube
1 shared publication- Edgar G. Chedrawy
Department of Surgery, Weiss Memorial Hospital, Chicago, IL, USA.
1 shared publication Gregory D. Byrd
1 shared publicationJegan Gopal
1 shared publicationRalph J. Damiano Jr.
1 shared publication
Latest Publications
- Open Access
- 2 January 2014
- Published by Wiley in Surgery Research and Practice
- Vol. 2014, 1-6
Coronary Artery Bypass Graft Surgery: The Past, Present, and Future of Myocardial Revascularisation
The development of the heart-lung machine ushered in the era of modern cardiac surgery. Coronary artery bypass graft surgery (CABG) remains the most common operation performed by cardiac surgeons today. From its infancy in the 1950s till today, CABG has undergone many developments both technically and clinically. Improvements in intraoperative technique and perioperative care have led to CABG being offered to a more broad patient profile with less complications and adverse events. Our review outlines the rich history and promising future of myocardial revascularization.
- 2 January 2014
- Published by Wiley in Surgery Research and Practice
- Vol. 2014, 1-6
Open AccessCoronary Artery Bypass Graft Surgery: The Past, Present, and Future of Myocardial Revascularisation
The development of the heart-lung machine ushered in the era of modern cardiac surgery. Coronary artery bypass graft surgery (CABG) remains the most common operation performed by cardiac surgeons today. From its infancy in the 1950s till today, CABG has undergone many developments both technically and clinically. Improvements in intraoperative technique and perioperative care have led to CABG being offered to a more broad patient profile with less complications and adverse events. Our review outlines the rich history and promising future of myocardial revascularization.
- 29 August 2005
- Published by IMR Press in The Heart Surgery Forum
- Vol. 8 (5) , 331-336
Dose Response Curves for Microwave Ablation in the Cardioplegia-Arrested Porcine Heart
Introduction: Microwave ablation has been used clinically for the surgical treatment of atrial fibrillation, particularly during valve procedures. However, dose- response curves have not been established for this surgical environment. The purpose of this study was to examine dosimetry curves for the Flex 4 and Flex 10 microwave devices in an acute cardioplegia-arrested porcine model. Methods: Twelve domestic pigs (40-45 kg) were acutely subjected to Flex 4 (n = 6) and Flex 10 (n = 6) ablations. On a cardioplegically arrested heart maintained at 10-15oC, six endocardial atrial and seven epicardial ventricular lesions were created in each animal. Ablations were performed for 15 s, 30 s, 45 s, 60 s, 90 s, 120 s, and 150 s (65 W, 2.45 GHz). The tissue was stained with 2,3,5-triphenyl-tetrazolium chloride and lesions were sectioned at 5 mm intervals. Lesion depth and width were determined from digital photomicrographs of each lesion (resolution .03 mm). Results: Average atrial thickness was 2.88 .4 mm (range 1.0 to 8.0 mm). 94% of ablated atrial sections created by the FLEX 4 (n = 16) and the FLEX 10 (n = 16) were transmural at 45 seconds. 100% of atrial sections were transmural at 90 seconds with the FLEX 10 (n = 14) and at 60 seconds with the Flex 4 device (n = 15). Lesion width and depth increased with duration of application. Conclusion: Both devices were capable of producing transmural lesions on the cardioplegically arrested heart at 65 W. These curves will allow surgeons to ensure transmural ablation by tailoring energy delivery to the specific atrial geometry.
- 29 August 2005
- Published by IMR Press in The Heart Surgery Forum
- Vol. 8 (5) , 331-336
Dose Response Curves for Microwave Ablation in the Cardioplegia-Arrested Porcine Heart
Introduction: Microwave ablation has been used clinically for the surgical treatment of atrial fibrillation, particularly during valve procedures. However, dose- response curves have not been established for this surgical environment. The purpose of this study was to examine dosimetry curves for the Flex 4 and Flex 10 microwave devices in an acute cardioplegia-arrested porcine model. Methods: Twelve domestic pigs (40-45 kg) were acutely subjected to Flex 4 (n = 6) and Flex 10 (n = 6) ablations. On a cardioplegically arrested heart maintained at 10-15oC, six endocardial atrial and seven epicardial ventricular lesions were created in each animal. Ablations were performed for 15 s, 30 s, 45 s, 60 s, 90 s, 120 s, and 150 s (65 W, 2.45 GHz). The tissue was stained with 2,3,5-triphenyl-tetrazolium chloride and lesions were sectioned at 5 mm intervals. Lesion depth and width were determined from digital photomicrographs of each lesion (resolution .03 mm). Results: Average atrial thickness was 2.88 .4 mm (range 1.0 to 8.0 mm). 94% of ablated atrial sections created by the FLEX 4 (n = 16) and the FLEX 10 (n = 16) were transmural at 45 seconds. 100% of atrial sections were transmural at 90 seconds with the FLEX 10 (n = 14) and at 60 seconds with the Flex 4 device (n = 15). Lesion width and depth increased with duration of application. Conclusion: Both devices were capable of producing transmural lesions on the cardioplegically arrested heart at 65 W. These curves will allow surgeons to ensure transmural ablation by tailoring energy delivery to the specific atrial geometry.