Arnaud Guertin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Arnaud Guertin has a total of 367 co-authors. Here are the top co-authors by number of shared publications:
- Ferid Haddad
GIP ARRONAX, 1 rue Aronnax, CS10112
34 shared publications - Vincent Metivier
Laboratoire SUBATECH, IMT Atlantique, CNRS/IN2P3, Université de Nantes, Nantes, France
24 shared publications - Nathalie Michel
SUBATECH, Ecole des Mines de Nantes, Université de Nantes, CNRS/IN2P3, Nantes, France; GIP Arronax, 1 rue Aronnax, 44817 Saint-Herblain, France
17 shared publications - Charbel Koumeir
GIP Arronax, Saint-Herblain, France
13 shared publications V. Blideanu
9 shared publicationsY. Foucher
9 shared publications
Latest Publications
- Open Access
- 14 April 2026
- Published by Elsevier in SSRN Electronic Journal
High-fluence light-ion irradiation effects on CVD diamond detectors: Charge Collection Efficiency degradation, defect formation and annealing recovery
The use of pulsed ion beams in physics, materials science, and medical applications requires detectors capable of providing fast, reliable signals under extreme irradiation conditions [1, 2]. Successive ion bunches delivered at high repetition rates result in intense instantaneous particle fluxes, demanding detectors with thin, radiation-hard active volumes [3]. Diamond is a material of choice for such applications due to its wide bandgap, high carrier mobility, and intrinsic radiation hardness [4, 5, 6, 7, 8, 9, 10]. However, cumulative exposure to high-fluence ion beams creates lattice defects, such as vacancies and vacancy complexes, that degrade the charge collection efficiency (CCE) and limit detector performance [11]. To address these challenges, the DIAMMONI detector was developed. Diamond active volumes were characterized under 68 MeV proton and 64 MeV helium ion irradiation using three complementary techniques: alpha-source spectroscopy to evaluate the CCE [12, 13], Raman spectroscopy to identify irradiation-induced defects, and X-ray Beam-Induced Current (XBIC) mapping at the ESRF [14]. This systematic approach enables a quantitative assessment of diamond detector performance under high-fluence irradiation, including the determination of a radiation damage constant. The effect of thermal annealing on CCE recovery was also investigated, providing a comprehensive understanding of defect dynamics and guidance for the design of robust diamond-based detectors for pulsed ion beam applications.
- 14 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHigh-fluence light-ion irradiation effects on CVD diamond detectors: Charge Collection Efficiency degradation, defect formation and annealing recovery
The use of pulsed ion beams in physics, materials science, and medical applications requires detectors capable of providing fast, reliable signals under extreme irradiation conditions [1, 2]. Successive ion bunches delivered at high repetition rates result in intense instantaneous particle fluxes, demanding detectors with thin, radiation-hard active volumes [3]. Diamond is a material of choice for such applications due to its wide bandgap, high carrier mobility, and intrinsic radiation hardness [4, 5, 6, 7, 8, 9, 10]. However, cumulative exposure to high-fluence ion beams creates lattice defects, such as vacancies and vacancy complexes, that degrade the charge collection efficiency (CCE) and limit detector performance [11]. To address these challenges, the DIAMMONI detector was developed. Diamond active volumes were characterized under 68 MeV proton and 64 MeV helium ion irradiation using three complementary techniques: alpha-source spectroscopy to evaluate the CCE [12, 13], Raman spectroscopy to identify irradiation-induced defects, and X-ray Beam-Induced Current (XBIC) mapping at the ESRF [14]. This systematic approach enables a quantitative assessment of diamond detector performance under high-fluence irradiation, including the determination of a radiation damage constant. The effect of thermal annealing on CCE recovery was also investigated, providing a comprehensive understanding of defect dynamics and guidance for the design of robust diamond-based detectors for pulsed ion beam applications.
- Open Access
- 10 April 2026
- Published by Elsevier in SSRN Electronic Journal
Molecular Plating for targetry: proof of concept using natGd(p,x)155Tb cross section measurements
The production of radionuclides for nuclear medicine is crucial for advancements in both diagnosis and therapy. 155Tb stands out as a promising candidate for SPECT imaging and as counterpart of the therapeutic radionuclide 161Tb in a theranostics approach. This work focuses on the gadolinium target fabrication process via molecular plating (MP) and its uses to study the production and identification of activation products when irradiated with proton. A particular attention is devoted on the quality of the produced targets using different analytical techniques. These findings contribute to ongoing efforts to establish reliable production routes for 155Tb. Our results show good agreement with the literature and simulation data, providing new experimental data to the production of 155Tb and other co-products or impurities via the bombardment of natGd targets and the contribution of (p,x) nuclear reactions, thus validating the MP technique for cross section measurements. This paves the way to fabricate enriched lanthanides target to explore extensively the production of radio-lanthanides.
- 10 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMolecular Plating for targetry: proof of concept using natGd(p,x)155Tb cross section measurements
The production of radionuclides for nuclear medicine is crucial for advancements in both diagnosis and therapy. 155Tb stands out as a promising candidate for SPECT imaging and as counterpart of the therapeutic radionuclide 161Tb in a theranostics approach. This work focuses on the gadolinium target fabrication process via molecular plating (MP) and its uses to study the production and identification of activation products when irradiated with proton. A particular attention is devoted on the quality of the produced targets using different analytical techniques. These findings contribute to ongoing efforts to establish reliable production routes for 155Tb. Our results show good agreement with the literature and simulation data, providing new experimental data to the production of 155Tb and other co-products or impurities via the bombardment of natGd targets and the contribution of (p,x) nuclear reactions, thus validating the MP technique for cross section measurements. This paves the way to fabricate enriched lanthanides target to explore extensively the production of radio-lanthanides.
- 4 December 2025
- Published by Wiley in X-Ray Spectrometry
- Vol. 55 (3) , 454-464
Study of Bremsstrahlung X‐Rays Emitted During Monoenergetic and Spread‐Out Bragg Peak Proton Irradiations in Preclinical Conditions
Hadrontherapy treatments generally take advantage of the finite path of the ions in matter to limit healthy tissue irradiation. The absence of a transmitted beam, however, complicates the online assessment of the targeting. This verification becomes even more crucial with low‐energy ion beams used for small animal preclinical irradiations, easily disrupted by changes in the tissues or in the position of the animal, and when comparing different irradiation techniques, such as irradiation in the Bragg plateau of a monoenergetic beam and irradiation in the spread‐out Bragg peak (SOBP). The bremsstrahlung X‐rays emitted during irradiation by a 68 MeV proton beam were studied along a mouse‐sized cylindrical phantom on a realistic beamline, including a ridge filter allowing passive shaping of the SOBP. A compact semiconductor spectrometer was positioned orthogonally to the beam propagation direction. The detector's field of view was controlled using a 2 mm diameter collimator fixed on a tailored tungsten shield. More than 1000 X‐rays/Gy were detected, even in the Bragg peak regions for both monoenergetic and SOBP beams. The absorbed dose at a fixed position in the Bragg curve's plateau can be accurately determined (< 1.5% at 1 Gy) using X‐ray energy spectrum integrals. Furthermore, partial integral ratios, X‐ray average energy and X‐ray energy at the maximum amplitude of the spectrum showed a similar variation with proton mean energy in the field of view for both modalities. Bremsstrahlung X‐rays are a promising probe to monitor in real time the irradiation of small animals at preclinical absorbed doses.
- 4 December 2025
- Published by Wiley in X-Ray Spectrometry
- Vol. 55 (3) , 454-464
Study of Bremsstrahlung X‐Rays Emitted During Monoenergetic and Spread‐Out Bragg Peak Proton Irradiations in Preclinical Conditions
Hadrontherapy treatments generally take advantage of the finite path of the ions in matter to limit healthy tissue irradiation. The absence of a transmitted beam, however, complicates the online assessment of the targeting. This verification becomes even more crucial with low‐energy ion beams used for small animal preclinical irradiations, easily disrupted by changes in the tissues or in the position of the animal, and when comparing different irradiation techniques, such as irradiation in the Bragg plateau of a monoenergetic beam and irradiation in the spread‐out Bragg peak (SOBP). The bremsstrahlung X‐rays emitted during irradiation by a 68 MeV proton beam were studied along a mouse‐sized cylindrical phantom on a realistic beamline, including a ridge filter allowing passive shaping of the SOBP. A compact semiconductor spectrometer was positioned orthogonally to the beam propagation direction. The detector's field of view was controlled using a 2 mm diameter collimator fixed on a tailored tungsten shield. More than 1000 X‐rays/Gy were detected, even in the Bragg peak regions for both monoenergetic and SOBP beams. The absorbed dose at a fixed position in the Bragg curve's plateau can be accurately determined (< 1.5% at 1 Gy) using X‐ray energy spectrum integrals. Furthermore, partial integral ratios, X‐ray average energy and X‐ray energy at the maximum amplitude of the spectrum showed a similar variation with proton mean energy in the field of view for both modalities. Bremsstrahlung X‐rays are a promising probe to monitor in real time the irradiation of small animals at preclinical absorbed doses.
- Open Access
- 13 November 2025
- Published by IOP Publishing in Journal of Physics G: Nuclear and Particle Physics
- Vol. 52 (11) , 115102
Nuclear cross-section of the nat Eu( α , x ) reactions up to 65 MeV: focus on the production of theranostic radioisotopes of terbium
Terbium is considered a promising element for theranostic applications in nuclear medicine due to its four medically-relevant radioisotopes: 149 Tb, 152 Tb, 155 Tb and 161 Tb, each suited for different diagnostic or therapeutic uses. Despite its potential, the clinical adoption of terbium is hindered by the lack of large-scale production methods for these isotopes. This work presents the first comprehensive study of nuclear cross-sections for nat Eu( α , x ) reactions, using europium oxide targets, in the energy range of 20–65 MeV for 155 Tb production. Theoretical simulations using TALYS 1.96 were performed, highlighting the need for further model refinements. Additionally, we employed the Non-dominated Sorting Genetic algorithm II (NSGA-II) to optimize the production parameters for 155 Tb on enriched 153 Eu targets.These findings contribute to optimizing production routes for terbium isotopes, supporting future developments in nuclear medicine.
- 13 November 2025
- Published by IOP Publishing in Journal of Physics G: Nuclear and Particle Physics
- Vol. 52 (11) , 115102
Open AccessNuclear cross-section of the nat Eu( α , x ) reactions up to 65 MeV: focus on the production of theranostic radioisotopes of terbium
Terbium is considered a promising element for theranostic applications in nuclear medicine due to its four medically-relevant radioisotopes: 149 Tb, 152 Tb, 155 Tb and 161 Tb, each suited for different diagnostic or therapeutic uses. Despite its potential, the clinical adoption of terbium is hindered by the lack of large-scale production methods for these isotopes. This work presents the first comprehensive study of nuclear cross-sections for nat Eu( α , x ) reactions, using europium oxide targets, in the energy range of 20–65 MeV for 155 Tb production. Theoretical simulations using TALYS 1.96 were performed, highlighting the need for further model refinements. Additionally, we employed the Non-dominated Sorting Genetic algorithm II (NSGA-II) to optimize the production parameters for 155 Tb on enriched 153 Eu targets.These findings contribute to optimizing production routes for terbium isotopes, supporting future developments in nuclear medicine.
- Open Access
- 19 April 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 221
New experimental measurements of X-ray emissions induced by protons of several tens of MeV on elements with Z=22 to Z=79: Toward quantitative high-energy PIXE
- 19 April 2024
- Published by Elsevier in Radiation Physics and Chemistry
- Vol. 221
Open AccessNew experimental measurements of X-ray emissions induced by protons of several tens of MeV on elements with Z=22 to Z=79: Toward quantitative high-energy PIXE
- 16 May 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 186, 110287
Electrochemical co-deposition of Ni–Gd2O3 for composite thin targets preparation: Production of 155Tb as a case study
- 16 May 2022
- Published by Elsevier in Applied Radiation and Isotopes
- Vol. 186, 110287
Electrochemical co-deposition of Ni–Gd2O3 for composite thin targets preparation: Production of 155Tb as a case study
- Open Access
- 1 August 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 500-501, 76-82
Bremsstrahlung X-rays as a non-invasive tool for ion beam monitoring
- 1 August 2021
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 500-501, 76-82
Open AccessBremsstrahlung X-rays as a non-invasive tool for ion beam monitoring
- Open Access
A Monte Carlo Determination of Dose and Range Uncertainties for Preclinical Studies with a Proton Beam
Proton therapy (PRT) is an irradiation technique that aims at limiting normal tissue damage while maintaining the tumor response. To study its specificities, the ARRONAX cyclotron is currently developing a preclinical structure compatible with biological experiments. A prerequisite is to identify and control uncertainties on the ARRONAX beamline, which can lead to significant biases in the observed biological results and dose–response relationships, as for any facility. This paper summarizes and quantifies the impact of uncertainty on proton range, absorbed dose, and dose homogeneity in a preclinical context of cell or small animal irradiation on the Bragg curve, using Monte Carlo simulations. All possible sources of uncertainty were investigated and discussed independently. Those with a significant impact were identified, and protocols were established to reduce their consequences. Overall, the uncertainties evaluated were similar to those from clinical practice and are considered compatible with the performance of radiobiological experiments, as well as the study of dose–response relationships on this proton beam. Another conclusion of this study is that Monte Carlo simulations can be used to help build preclinical lines in other setups.
Open AccessA Monte Carlo Determination of Dose and Range Uncertainties for Preclinical Studies with a Proton Beam
Proton therapy (PRT) is an irradiation technique that aims at limiting normal tissue damage while maintaining the tumor response. To study its specificities, the ARRONAX cyclotron is currently developing a preclinical structure compatible with biological experiments. A prerequisite is to identify and control uncertainties on the ARRONAX beamline, which can lead to significant biases in the observed biological results and dose–response relationships, as for any facility. This paper summarizes and quantifies the impact of uncertainty on proton range, absorbed dose, and dose homogeneity in a preclinical context of cell or small animal irradiation on the Bragg curve, using Monte Carlo simulations. All possible sources of uncertainty were investigated and discussed independently. Those with a significant impact were identified, and protocols were established to reduce their consequences. Overall, the uncertainties evaluated were similar to those from clinical practice and are considered compatible with the performance of radiobiological experiments, as well as the study of dose–response relationships on this proton beam. Another conclusion of this study is that Monte Carlo simulations can be used to help build preclinical lines in other setups.
- 1 September 2020
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 479, 120-124
High energy PIXE: New experimental K-shell ionization cross sections for silver and gold and comparison with theoretical values from ECPSSR/RECPSSR models
- 1 September 2020
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
- Vol. 479, 120-124
High energy PIXE: New experimental K-shell ionization cross sections for silver and gold and comparison with theoretical values from ECPSSR/RECPSSR models