Ehsan Abadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ehsan Abadi has a total of 192 co-authors. Here are the top co-authors by number of shared publications:
- Ehsan Samei
Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705
43 shared publications - William Paul Segars
Duke University
16 shared publications Ehsan Samei
Department of Radiology, Duke University, Durham, USA
14 shared publicationsShobhit Sharma
Center for Virtual Imaging Trials and Carl E. Ravin Advanced Imaging Laboratories, 2424 Erwin Rd, Suite 302, Durham, NC 27705, USA; Department of Physics, Duke University, Science Drive, Durham, NC 27708, USA
7 shared publicationsBrian Harrawood
From the Department of Radiology, Duke University Hospital, 2301 Erwin Rd, Box 3808, Durham, NC 27701 (B.W.T., K.R.K., B.C.A., S.P.T., D.E.K., B.H., M.R.B., D.M., E.S., E.A.); Department of Biostatistics and Bioinformatics (N.F., S.M., A.E.) and Department of Medical Physics (W.P.S., E.S., E.A.), Duke University, Durham, NC
6 shared publications- Mojtaba Zarei
Duke University School of Medicine, 2424 Erwin Road, Durham, North Carolina, 27705, UNITED STATES
6 shared publications
Latest Publications
- 1 December 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (6)
Reproducibility of Lung Densitometry with Photon-counting Detector and Energy-integrating Detector CT: A Multi-Institutional Phantom Study
In this multi-institutional, multiphantom study, photon-counting detector CT provided more accurate and reproducible lung densitometry while maintaining comparability with energy-integrating detector CT protocols.
- 1 December 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (6)
Reproducibility of Lung Densitometry with Photon-counting Detector and Energy-integrating Detector CT: A Multi-Institutional Phantom Study
In this multi-institutional, multiphantom study, photon-counting detector CT provided more accurate and reproducible lung densitometry while maintaining comparability with energy-integrating detector CT protocols.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (11) , 3612-3623
Virtual Imaging-Guided Harmonization of Chest X-Rays Using a Generative Adversarial Neural Network
To reduce variability in chest radiography (CXR) from acquisition and post-processing, and assess whether harmonization improves image quality and down-stream diagnostic performance. A generative adversarial network (GAN) was trained exclusively on virtual images produced by a Virtual Imaging Trial (VIT). The model maps non-harmonized CXRs to noise-free, unprocessed references using a dual U-Net with contrastive loss. Evaluation spanned virtual, physical-phantom, and clinical data using generic (GIQMs) and chest-specific (CIQMs) metrics. A phantom benchmark compared the method with ComBat harmonization and a conventional denoising algorithm. Clinical generalization was tested on VinDr-CXRs, examining feature compactness via Uniform Manifold Approximation and Projection (UMAP). We also assessed NIH-CXRs, quantifying diagnostic accuracy with bootstrap uncertainty. Compared with non-harmonized images, harmonized CXRs yielded approximately 89% lower NRMSE, 50% higher PSNR, and 86% higher SSIM. On phantom data, CIQM variability fell from 0.255 to 0.026 and was reduced more consistently than with ComBat or denoising. Clinical analyses on VinDr-CXRs showed tighter UMAP clusters for harmonized features, indicating suppression of acquisition-related variability. On NIH-CXRs, training and testing a classifier in the harmonized domain improved diagnostic accuracy over the non-harmonized domain and lowered cross-domain sensitivity; pleural and cardiac categories showed consistent gains, while texture-dependent labels exhibited task-dependent effects. VIT-guided training enables a GAN to harmonize CXRs toward a raw reference, improving quantification variability and harmonizing image representations across systems. The proposed virtual-to-clinical strategy is scalable and generalizable, offering a practical path to standardized CXR appearance and reliable downstream detection across institutions.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 73 (11) , 3612-3623
Virtual Imaging-Guided Harmonization of Chest X-Rays Using a Generative Adversarial Neural Network
To reduce variability in chest radiography (CXR) from acquisition and post-processing, and assess whether harmonization improves image quality and down-stream diagnostic performance. A generative adversarial network (GAN) was trained exclusively on virtual images produced by a Virtual Imaging Trial (VIT). The model maps non-harmonized CXRs to noise-free, unprocessed references using a dual U-Net with contrastive loss. Evaluation spanned virtual, physical-phantom, and clinical data using generic (GIQMs) and chest-specific (CIQMs) metrics. A phantom benchmark compared the method with ComBat harmonization and a conventional denoising algorithm. Clinical generalization was tested on VinDr-CXRs, examining feature compactness via Uniform Manifold Approximation and Projection (UMAP). We also assessed NIH-CXRs, quantifying diagnostic accuracy with bootstrap uncertainty. Compared with non-harmonized images, harmonized CXRs yielded approximately 89% lower NRMSE, 50% higher PSNR, and 86% higher SSIM. On phantom data, CIQM variability fell from 0.255 to 0.026 and was reduced more consistently than with ComBat or denoising. Clinical analyses on VinDr-CXRs showed tighter UMAP clusters for harmonized features, indicating suppression of acquisition-related variability. On NIH-CXRs, training and testing a classifier in the harmonized domain improved diagnostic accuracy over the non-harmonized domain and lowered cross-domain sensitivity; pleural and cardiac categories showed consistent gains, while texture-dependent labels exhibited task-dependent effects. VIT-guided training enables a GAN to harmonize CXRs toward a raw reference, improving quantification variability and harmonizing image representations across systems. The proposed virtual-to-clinical strategy is scalable and generalizable, offering a practical path to standardized CXR appearance and reliable downstream detection across institutions.
- 9 September 2026
- Published by Springer Nature in European Radiology
- p. 1-15
Segmentation-based deep learning emphysema quantification using chest CT: improved accuracy and robustness vs LAA-950
Objectives To develop a deep learning segmentation algorithm to enable accurate, reliable emphysema quantification while improving agreement with radiologist assessments and pulmonary function tests. Materials and methods The model was developed using retrospective virtual and clinical datasets. Virtual data enabled pre-training using ground truth across controlled parameters, including scanners, doses, and reconstruction kernels, while clinical data enabled fine-tuning with expert-annotated emphysema masks. Segmentation accuracy was quantified using the Dice coefficient, and robustness was quantified using emphysema percentage consistency across imaging conditions. Model-based emphysema percentage was correlated with Fleischner visual scores (ordinal; 0–5) and pulmonary function tests (DLCO, FEV1pp, and FEV1/FVC) and compared to LAA-950. Statistical analysis included univariate/multivariate correlations. Quantitative assessment included Dice, bias, limits of agreement, and reproducibility coefficient. Results Virtual data included 20 human models (mean age: 43 years ± 11 [SD], 10 men), and clinical data included multi-center cohorts of 101 patients (C1; 57 years ± 8, 54 men), 23 patients (C2; 57 years ± 7, 14 men), and 1159 patients (C3; 65 years ± 9, 586 men). The model outperformed LAA-950 in segmentation accuracy, achieving higher Dice scores across virtual (76.6% ± 8.8 vs 51.5% ± 23.5), C1 (48.4% ± 24.2 vs 22.5% ± 20.2), and C2 (64.8% ± 9.3 vs 32.7% ± 16.8) cohorts. Furthermore, analysis showed improved bias and limits of agreement (C1; 1.0% ± 4.3 vs 2.1% ± 15.1) and stronger correlations with visual scoring (C1; 0.77 vs 0.47) and pulmonary function tests (C3; DLCO multivariate R²: 0.31–0.32 vs 0.21–0.25). Conclusion The proposed model provided a promising, clinically relevant alternative to LAA-950, improving accuracy and consistency in emphysema quantification and further aligning with radiologist assessments and lung function metrics. Key Points Question Can deep learning-based emphysema segmentation on CT improve the accuracy and robustness of emphysema quantification relative to the traditional LAA-950 biomarker? Findings The deep learning model outperformed LAA-950 in terms of accuracy and reproducibility and demonstrated stronger correlations with visual emphysema scores and pulmonary function tests. Clinical relevance The improved performance of the deep learning approach enables more reliable emphysema quantification across imaging conditions, with closer agreement to radiologist assessments and pulmonary function tests. Graphical Abstract
- 9 September 2026
- Published by Springer Nature in European Radiology
- p. 1-15
Segmentation-based deep learning emphysema quantification using chest CT: improved accuracy and robustness vs LAA-950
Objectives To develop a deep learning segmentation algorithm to enable accurate, reliable emphysema quantification while improving agreement with radiologist assessments and pulmonary function tests. Materials and methods The model was developed using retrospective virtual and clinical datasets. Virtual data enabled pre-training using ground truth across controlled parameters, including scanners, doses, and reconstruction kernels, while clinical data enabled fine-tuning with expert-annotated emphysema masks. Segmentation accuracy was quantified using the Dice coefficient, and robustness was quantified using emphysema percentage consistency across imaging conditions. Model-based emphysema percentage was correlated with Fleischner visual scores (ordinal; 0–5) and pulmonary function tests (DLCO, FEV1pp, and FEV1/FVC) and compared to LAA-950. Statistical analysis included univariate/multivariate correlations. Quantitative assessment included Dice, bias, limits of agreement, and reproducibility coefficient. Results Virtual data included 20 human models (mean age: 43 years ± 11 [SD], 10 men), and clinical data included multi-center cohorts of 101 patients (C1; 57 years ± 8, 54 men), 23 patients (C2; 57 years ± 7, 14 men), and 1159 patients (C3; 65 years ± 9, 586 men). The model outperformed LAA-950 in segmentation accuracy, achieving higher Dice scores across virtual (76.6% ± 8.8 vs 51.5% ± 23.5), C1 (48.4% ± 24.2 vs 22.5% ± 20.2), and C2 (64.8% ± 9.3 vs 32.7% ± 16.8) cohorts. Furthermore, analysis showed improved bias and limits of agreement (C1; 1.0% ± 4.3 vs 2.1% ± 15.1) and stronger correlations with visual scoring (C1; 0.77 vs 0.47) and pulmonary function tests (C3; DLCO multivariate R²: 0.31–0.32 vs 0.21–0.25). Conclusion The proposed model provided a promising, clinically relevant alternative to LAA-950, improving accuracy and consistency in emphysema quantification and further aligning with radiologist assessments and lung function metrics. Key Points Question Can deep learning-based emphysema segmentation on CT improve the accuracy and robustness of emphysema quantification relative to the traditional LAA-950 biomarker? Findings The deep learning model outperformed LAA-950 in terms of accuracy and reproducibility and demonstrated stronger correlations with visual emphysema scores and pulmonary function tests. Clinical relevance The improved performance of the deep learning approach enables more reliable emphysema quantification across imaging conditions, with closer agreement to radiologist assessments and pulmonary function tests. Graphical Abstract
- Open Access
- 29 August 2026
- Published by Oxford University Press (OUP) in PNAS Nexus
- Vol. 5 (9)
Complementary roles of virtual and real trials in medicine: An interplay of virtuous spirals
Virtual trials provide medical knowledge and practical methods for generating evidence through computational methods. But extending beyond those advantages, they offer epistemic opportunities to add mechanistic explainability to predictive inference of real trials. Relating the distinct contributions and ontology of virtual and real trials enables a transformative convergence of biological and clinical insights that they embody.
- 29 August 2026
- Published by Oxford University Press (OUP) in PNAS Nexus
- Vol. 5 (9)
Open AccessComplementary roles of virtual and real trials in medicine: An interplay of virtuous spirals
Virtual trials provide medical knowledge and practical methods for generating evidence through computational methods. But extending beyond those advantages, they offer epistemic opportunities to add mechanistic explainability to predictive inference of real trials. Relating the distinct contributions and ontology of virtual and real trials enables a transformative convergence of biological and clinical insights that they embody.
- 1 April 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (2) , e250124
Precise Lung Density Quantification with a Physics-based CT Harmonizer
A physics-based image harmonization method was developed and validated; it improved CT-based lung density reproducibility by aligning images to a reference quality index of noise, resolution, and lung volume.
- 1 April 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (2) , e250124
Precise Lung Density Quantification with a Physics-based CT Harmonizer
A physics-based image harmonization method was developed and validated; it improved CT-based lung density reproducibility by aligning images to a reference quality index of noise, resolution, and lung volume.
- 17 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (7)
Optimizing energy settings in CdTe, CZT, and Si photon-counting CT for material separation and detection
Objective: The performance of photon-counting CT (PCCT) depends on how detector energy thresholds or bins (collectively referred to as energy settings) are defined. This study aimed to identify optimal energy settings for various PCCT technologies to enhance spectral separability and spatial detectability of materials relevant to diagnostic imaging. Approach: We modeled vendor-neutral PCCT scanners with cadmium telluride (CdTe), cadmium zinc telluride (CZT), and silicon (Si) based detectors using an in-silico imaging framework. The scanner models incorporated scanner geometries and spatio-energetic detector responses to account for inter-pixel and inter-energy crosstalk and noise correlation. Using these models, we imaged two sizes of a cylindrical phantom containing inserts with various concentrations of calcium, iodine, and gadolinium across various energy settings and two dose levels. Other settings were held constant, including tube voltage (120 kV), pitch (1), gantry rotation speed (0.5 rot/second), and reconstruction settings. Image quality was quantified in terms of separability index (s') and contrast-to-noise ratio (CNR). The scanner-specific optimal energy settings were determined by ranking the measured s' values using a rank-sum method and evaluating them with the Friedman test. Main results:The optimal energy settings varied primarily with the phantom size and material pairs to separate (Ca-I, Ca-Gd, I-Gd) rather than the dose level. When aggregated across all imaging tasks and conditions, the optimal energy settings were 30-65 keV and 20-35-50-70 keV for two-and four-threshold CdTe-, 20-35-50-70 keV for four-threshold CZT-, and 5-35-50-80-120 keV for four-bin Si-based PCCT systems. Optimization of energy settings significantly improved material decomposition accuracy for Ca, I, and Gd across PCCT systems, particularly under low-concentration conditions, reducing percent differences from as high as 422.0% to within 17.0%. Significance:This work presents a simulation-based framework for optimizing energy settings of photon-counting detectors used in PCCT scanners, providing clinically translatable insights towards clinical adoption for accurate and standardized spectral imaging.
- 17 March 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (7)
Optimizing energy settings in CdTe, CZT, and Si photon-counting CT for material separation and detection
Objective: The performance of photon-counting CT (PCCT) depends on how detector energy thresholds or bins (collectively referred to as energy settings) are defined. This study aimed to identify optimal energy settings for various PCCT technologies to enhance spectral separability and spatial detectability of materials relevant to diagnostic imaging. Approach: We modeled vendor-neutral PCCT scanners with cadmium telluride (CdTe), cadmium zinc telluride (CZT), and silicon (Si) based detectors using an in-silico imaging framework. The scanner models incorporated scanner geometries and spatio-energetic detector responses to account for inter-pixel and inter-energy crosstalk and noise correlation. Using these models, we imaged two sizes of a cylindrical phantom containing inserts with various concentrations of calcium, iodine, and gadolinium across various energy settings and two dose levels. Other settings were held constant, including tube voltage (120 kV), pitch (1), gantry rotation speed (0.5 rot/second), and reconstruction settings. Image quality was quantified in terms of separability index (s') and contrast-to-noise ratio (CNR). The scanner-specific optimal energy settings were determined by ranking the measured s' values using a rank-sum method and evaluating them with the Friedman test. Main results:The optimal energy settings varied primarily with the phantom size and material pairs to separate (Ca-I, Ca-Gd, I-Gd) rather than the dose level. When aggregated across all imaging tasks and conditions, the optimal energy settings were 30-65 keV and 20-35-50-70 keV for two-and four-threshold CdTe-, 20-35-50-70 keV for four-threshold CZT-, and 5-35-50-80-120 keV for four-bin Si-based PCCT systems. Optimization of energy settings significantly improved material decomposition accuracy for Ca, I, and Gd across PCCT systems, particularly under low-concentration conditions, reducing percent differences from as high as 422.0% to within 17.0%. Significance:This work presents a simulation-based framework for optimizing energy settings of photon-counting detectors used in PCCT scanners, providing clinically translatable insights towards clinical adoption for accurate and standardized spectral imaging.
- 5 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
Truth-based physics informed estimation of material composition in spectral CT in terms of density and effective atomic number
Objective: Spectral CT data from Photon-Counting CT (PCCT) enables material decomposition. Mechanistic approaches such as Maximum Likelihood Estimation (MLE) are noise sensitive. Deep learning alternatives mitigate this issue, but their accuracy remains limited due to lack of incorporation of underlying physics principles and lack of ground truth data. This study aims to develop and validate a physics-informed deep-learning model, trained on validated simulated data, to decompose spectral CT images into density\ (\rho) and effective atomic number (Zeff) maps. Methods: The training dataset included simulated abdominal PCCT scans from 32 human models with corresponding ground truth. The scans were obtained at two clinical dose levels, four detector energy thresholds, different iodinated contrast agent concentrations and reconstructed using three clinically-used kernels. A Generative Adversarial Network (GAN) was trained with and without a physics-informed regularization loss to estimate ρ and Zeff maps. Model performance was evaluated on 16 computational phantoms and validated on 6 clinical cases. A reader study was performed on 30 image slices to assess the comparative performance of ρ and Zeff maps to multi-rendered Virtual Monochromatic Images (VMIs) for assessing liver lesion conspicuity. Main Results: With physics-informed regularization, NRMSE of 1.29% and 0.68%, SSIM of 0.99 and 0.99, and PSNR of 29.8dB and 29.04dB were achieved. A maximum RMSE of 5.45% was achieved on clinical data. Reader study results showed ρ and Zeff images had higher conspicuity scores compared to VMIs (median: 4.52 vs. 4.13; 95% CIs: [4.19, 4.52] vs. [4.01, 4.31]). The study showed equivalent conspicuity between VMIs and material images within a ±0.5 margin, though the small sample limits generalization. Significance: This study demonstrates the feasibility of material decomposition using a physics-informed GAN model trained on realistic simulated data. The maps provided equivalent conspicuity under a clinically acceptable margin, with a significantly small number of images for interpretation.
- 5 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (3)
Truth-based physics informed estimation of material composition in spectral CT in terms of density and effective atomic number
Objective: Spectral CT data from Photon-Counting CT (PCCT) enables material decomposition. Mechanistic approaches such as Maximum Likelihood Estimation (MLE) are noise sensitive. Deep learning alternatives mitigate this issue, but their accuracy remains limited due to lack of incorporation of underlying physics principles and lack of ground truth data. This study aims to develop and validate a physics-informed deep-learning model, trained on validated simulated data, to decompose spectral CT images into density\ (\rho) and effective atomic number (Zeff) maps. Methods: The training dataset included simulated abdominal PCCT scans from 32 human models with corresponding ground truth. The scans were obtained at two clinical dose levels, four detector energy thresholds, different iodinated contrast agent concentrations and reconstructed using three clinically-used kernels. A Generative Adversarial Network (GAN) was trained with and without a physics-informed regularization loss to estimate ρ and Zeff maps. Model performance was evaluated on 16 computational phantoms and validated on 6 clinical cases. A reader study was performed on 30 image slices to assess the comparative performance of ρ and Zeff maps to multi-rendered Virtual Monochromatic Images (VMIs) for assessing liver lesion conspicuity. Main Results: With physics-informed regularization, NRMSE of 1.29% and 0.68%, SSIM of 0.99 and 0.99, and PSNR of 29.8dB and 29.04dB were achieved. A maximum RMSE of 5.45% was achieved on clinical data. Reader study results showed ρ and Zeff images had higher conspicuity scores compared to VMIs (median: 4.52 vs. 4.13; 95% CIs: [4.19, 4.52] vs. [4.01, 4.31]). The study showed equivalent conspicuity between VMIs and material images within a ±0.5 margin, though the small sample limits generalization. Significance: This study demonstrates the feasibility of material decomposition using a physics-informed GAN model trained on realistic simulated data. The maps provided equivalent conspicuity under a clinically acceptable margin, with a significantly small number of images for interpretation.
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (01) , 1-16
Utility of the virtual imaging trials methodology for objective characterization of AI systems and training data
PurposeThe credibility of artificial intelligence (AI) models for medical imaging continues to be a challenge, affected by the diversity of models, the data used to train the models, and the applicability of their combination to produce reproducible results for new data. We aimed to explore whether emerging virtual imaging trial (VIT) methodologies can provide an objective resource to approach this challenge.ApproachWe conducted this study for the case example of COVID-19 diagnosis using clinical and virtual computed tomography (CT) and chest radiography (CXR) processed with convolutional neural networks. Multiple AI models were developed and tested using 3D ResNet-like and 2D EfficientNetv2 architectures across diverse datasets.ResultsModel performance was evaluated using the area under the curve (AUC) and the DeLong method for AUC confidence intervals. The models trained on the most diverse datasets showed the highest external testing performance, with AUC values ranging from 0.73 to 0.76 for CT and 0.70 to 0.73 for CXR. Internal testing yielded higher AUC values (0.77 to 0.85 for CT and 0.77 to 1.0 for CXR), highlighting a substantial drop in performance during external validation, which underscores the importance of diverse and comprehensive training and testing data. Most notably, the VIT approach provided an objective assessment of the utility of diverse models and datasets while offering insight into the influence of dataset characteristics, patient factors, and imaging physics on AI efficacy.ConclusionsThe VIT approach enhances model transparency and reliability, offering nuanced insights into the factors driving AI performance and bridging the gap between experimental and clinical settings.
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (01) , 1-16
Utility of the virtual imaging trials methodology for objective characterization of AI systems and training data
PurposeThe credibility of artificial intelligence (AI) models for medical imaging continues to be a challenge, affected by the diversity of models, the data used to train the models, and the applicability of their combination to produce reproducible results for new data. We aimed to explore whether emerging virtual imaging trial (VIT) methodologies can provide an objective resource to approach this challenge.ApproachWe conducted this study for the case example of COVID-19 diagnosis using clinical and virtual computed tomography (CT) and chest radiography (CXR) processed with convolutional neural networks. Multiple AI models were developed and tested using 3D ResNet-like and 2D EfficientNetv2 architectures across diverse datasets.ResultsModel performance was evaluated using the area under the curve (AUC) and the DeLong method for AUC confidence intervals. The models trained on the most diverse datasets showed the highest external testing performance, with AUC values ranging from 0.73 to 0.76 for CT and 0.70 to 0.73 for CXR. Internal testing yielded higher AUC values (0.77 to 0.85 for CT and 0.77 to 1.0 for CXR), highlighting a substantial drop in performance during external validation, which underscores the importance of diverse and comprehensive training and testing data. Most notably, the VIT approach provided an objective assessment of the utility of diverse models and datasets while offering insight into the influence of dataset characteristics, patient factors, and imaging physics on AI efficacy.ConclusionsThe VIT approach enhances model transparency and reliability, offering nuanced insights into the factors driving AI performance and bridging the gap between experimental and clinical settings.
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (01) , 1-19
Airway quantifications of bronchitis patients with photon-counting and energy-integrating computed tomography
PurposeAccurate airway measurement is critical for bronchitis quantification with computed tomography (CT), yet optimal protocols and the added value of photon-counting CT (PCCT) over energy-integrating CT (EICT) for reducing bias remain unclear. We quantified biomarker accuracy across modalities and protocols and assessed strategies to reduce bias.ApproachA virtual imaging trial with 20 bronchitis anthropomorphic models was scanned using a validated simulator for two systems (EICT: SOMATOM Flash; PCCT: NAEOTOM Alpha) at 6.3 and 12.6 mGy. Reconstructions varied algorithm, kernel sharpness, slice thickness, and pixel size. Pi10 (square-root wall thickness at 10-mm perimeter) and WA% (wall-area percentage) were compared against ground-truth airway dimensions obtained from the 0.1-mm-precision anatomical models prior to CT simulation. External validation used clinical PCCT (n=22) and EICT (n=80).ResultsSimulated airway dimensions agreed with pathological references (R=0.89−0.93). PCCT had lower errors than EICT across segmented generations (p<0.05). Under optimal parameters, PCCT improved Pi10 and WA% accuracy by 26.3% and 64.9%. Across the tested PCCT and EICT imaging protocols, improvements were associated with sharper kernels (25.8% Pi10, 33.0% WA%), thinner slices (23.9% Pi10, 49.8% WA%), smaller pixels (17.0% Pi10, 23.1% WA%), and higher dose (≤3.9%). Clinically, PCCT achieved higher maximum airway generation (8.8±0.5 versus 6.0±1.1) and lower variability, mirroring trends in virtual results.ConclusionsPCCT improves the accuracy and consistency of airway biomarker quantification relative to EICT, particularly with optimized protocols. The validated virtual platform enables modality-bias assessment and protocol optimization for accurate, reproducible bronchitis measurements.
- 1 January 2026
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 13 (01) , 1-19
Airway quantifications of bronchitis patients with photon-counting and energy-integrating computed tomography
PurposeAccurate airway measurement is critical for bronchitis quantification with computed tomography (CT), yet optimal protocols and the added value of photon-counting CT (PCCT) over energy-integrating CT (EICT) for reducing bias remain unclear. We quantified biomarker accuracy across modalities and protocols and assessed strategies to reduce bias.ApproachA virtual imaging trial with 20 bronchitis anthropomorphic models was scanned using a validated simulator for two systems (EICT: SOMATOM Flash; PCCT: NAEOTOM Alpha) at 6.3 and 12.6 mGy. Reconstructions varied algorithm, kernel sharpness, slice thickness, and pixel size. Pi10 (square-root wall thickness at 10-mm perimeter) and WA% (wall-area percentage) were compared against ground-truth airway dimensions obtained from the 0.1-mm-precision anatomical models prior to CT simulation. External validation used clinical PCCT (n=22) and EICT (n=80).ResultsSimulated airway dimensions agreed with pathological references (R=0.89−0.93). PCCT had lower errors than EICT across segmented generations (p<0.05). Under optimal parameters, PCCT improved Pi10 and WA% accuracy by 26.3% and 64.9%. Across the tested PCCT and EICT imaging protocols, improvements were associated with sharper kernels (25.8% Pi10, 33.0% WA%), thinner slices (23.9% Pi10, 49.8% WA%), smaller pixels (17.0% Pi10, 23.1% WA%), and higher dose (≤3.9%). Clinically, PCCT achieved higher maximum airway generation (8.8±0.5 versus 6.0±1.1) and lower variability, mirroring trends in virtual results.ConclusionsPCCT improves the accuracy and consistency of airway biomarker quantification relative to EICT, particularly with optimized protocols. The validated virtual platform enables modality-bias assessment and protocol optimization for accurate, reproducible bronchitis measurements.