JMJan Michálek

Jan Michálek

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jan Michálek has a total of 478 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Smooth dynamic T2* mapping in fMRI based on a novel, total variation-minimizing algorithm for efficient multi-echo BOLD time series denoising with high signal-to-noise and contrast-to-noise ratios

    by Jan Michálek, Michal Mikl

    Introduction: This report deals with advanced processing of blood oxygenation-dependent (BOLD) functional magnetic resonance imaging (fMRI) signals. It does not address functional characteristics of the human cortex, such as functional connectivity. fMRI is based on measurement of BOLD variations of transverse relaxation time T2* or T2. T2* or T2 can be calculated when multiple echoes of the MRI signal are recorded and may be more resistant to artifacts or better characterize tissue properties than the echoes themselves.Objectives: To develop a robust-to-noise algorithm for dynamic T2* mapping from a three gradient-echo (GRE) signal, allowing exploration of the potential of quantitative T2* mapping.Methods: fMRI resting-state and block-design visual task three-echo data were acquired from nine healthy volunteers. A significant problem in multi-echo T2* fitting is the noise in the echoes. The majority of BOLD-denoising methods first pinpoint some source of noise and subsequently remove the respective noise time series. We instead first postulated that the blood oxygenation changes smoothly and consequently developed a state-of-the-art denoising algorithm that minimizes total variation (TV), enforcing smoothness in the processed BOLD echoes while preserving local temporal signal means. To ensure that calculated T2* time courses are also smooth, they were estimated from TV-denoised echoes. We used a denoising approach initially proposed by Professor Stanley Osher for two-dimensional (2D) images that has been very successful, most prominently in space research, where it enabled the reconstruction of the first-ever image of a black hole. To our knowledge, Osher’s approach has so far not been used elsewhere for the denoising of one-dimensional fMRI time series.Results: Signal-to-noise and contrast-to-noise distributions of the denoised echoes, as well as of the T2* time series, were superior to those obtained by the current fMRI denoising methods (3dDespike, tedana, NORDIC). The denoised echoes and the T2* time courses match the shape of the theoretical hemodynamic function much better than previous results.Conclusion: The TV-minimizing fMRI time series denoising algorithm yields denoised echoes of unprecedented quality, enabling estimation of smooth, dynamic T2* maps, i.e., a transition from qualitative-only fMRI echoes to fMRI signals endowed with time units.


  • Top Cited Papers
    Open Access

    Towards fair decentralized benchmarking of healthcare AI algorithms with the Federated Tumor Segmentation (FeTS) challenge

    by Maximilian Zenk, Ujjwal Baid, Sarthak Pati, Akis Linardos, Brandon Edwards, Micah Sheller, Patrick Foley, Alejandro Aristizabal, David Zimmerer, Alexey Gruzdev, et al.

    Computational competitions are the standard for benchmarking medical image analysis algorithms, but they typically use small curated test datasets acquired at a few centers, leaving a gap to the reality of diverse multicentric patient data. To this end, the Federated Tumor Segmentation (FeTS) Challenge represents the paradigm for real-world algorithmic performance evaluation. The FeTS challenge is a competition to benchmark (i) federated learning aggregation algorithms and (ii) state-of-the-art segmentation algorithms, across multiple international sites. Weight aggregation and client selection techniques were compared using a multicentric brain tumor dataset in realistic federated learning simulations, yielding benefits for adaptive weight aggregation, and efficiency gains through client sampling. Quantitative performance evaluation of state-of-the-art segmentation algorithms on data distributed internationally across 32 institutions yielded good generalization on average, albeit the worst-case performance revealed data-specific modes of failure. Similar multi-site setups can help validate the real-world utility of healthcare AI algorithms in the future.


  • Open Access

    Author Correction: Federated learning enables big data for rare cancer boundary detection

    by Sarthak Pati, Ujjwal Baid, Brandon Edwards, Micah Sheller, Shih-Han Wang, G Anthony Reina, Patrick Foley, Alexey Gruzdev, Deepthi Karkada, Christos Davatzikos, et al.


  • Top Cited Papers
    Open Access

    Federated learning enables big data for rare cancer boundary detection

    by Sarthak Pati, Ujjwal Baid, Brandon Edwards, Micah Sheller, Shih-Han Wang, G. Anthony Reina, Patrick Foley, Alexey Gruzdev, Deepthi Karkada, Christos Davatzikos, et al.

    Although machine learning (ML) has shown promise across disciplines, out-of-sample generalizability is concerning. This is currently addressed by sharing multi-site data, but such centralization is challenging/infeasible to scale due to various limitations. Federated ML (FL) provides an alternative paradigm for accurate and generalizable ML, by only sharing numerical model updates. Here we present the largest FL study to-date, involving data from 71 sites across 6 continents, to generate an automatic tumor boundary detector for the rare disease of glioblastoma, reporting the largest such dataset in the literature (n = 6, 314). We demonstrate a 33% delineation improvement for the surgically targetable tumor, and 23% for the complete tumor extent, over a publicly trained model. We anticipate our study to: 1) enable more healthcare studies informed by large diverse data, ensuring meaningful results for rare diseases and underrepresented populations, 2) facilitate further analyses for glioblastoma by releasing our consensus model, and 3) demonstrate the FL effectiveness at such scale and task-complexity as a paradigm shift for multi-site collaborations, alleviating the need for data-sharing.


  • Quantitative Assessment of Anti-Cancer Drug Efficacy From Coregistered Mass Spectrometry and Fluorescence Microscopy Images of Multicellular Tumor Spheroids

    by Jan Michálek, Karel Štěpka, Michal Kozubek, Jarmila Navrátilová, Barbora Pavlatovská, Markéta Machálková, Jan Preisler, Adam Pruška

    Spheroids—three-dimensional aggregates of cells grown from a cancer cell line—represent a model of living tissue for chemotherapy investigation. Distribution of chemotherapeutics in spheroid sections was determined using the matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI). Proliferating or apoptotic cells were immunohistochemically labeled and visualized by laser scanning confocal fluorescence microscopy (LSCM). Drug efficacy was evaluated by comparing coregistered MALDI MSI and LSCM data of drug-treated spheroids with LSCM only data of untreated control spheroids. We developed a fiducial-based workflow for coregistration of low-resolution MALDI MS with high-resolution LSCM images. To allow comparison of drug and cell distribution between the drug-treated and untreated spheroids of different shapes or diameters, we introduced a common diffusion-related coordinate, the distance from the spheroid boundary. In a procedure referred to as “peeling”, we correlated average drug distribution at a certain distance with the average reduction in the affected cells between the untreated and the treated spheroids. This novel approach makes it possible to differentiate between peripheral cells that died due to therapy and the innermost cells which died naturally. Two novel algorithms—for MALDI MS image denoising and for weighting of MALDI MSI and LSCM data by the presence of cell nuclei—are also presented.


  • Fast and accurate compensation of signal offset for T2 mapping

    by Jan Michálek, Pavla Hanzlíková, Tuan Trinh, Dalibor Pacík

    Objective T2 maps are more vendor independent than other MRI protocols. Multi-echo spin-echo signal decays to a non-zero offset due to imperfect refocusing pulses and Rician noise, causing T2 overestimation by the vendor’s 2-parameter algorithm. The accuracy of the T2 estimate is improved, if the non-zero offset is estimated as a third parameter. Three-parameter Levenberg–Marquardt (LM) T2 estimation takes several minutes to calculate, and it is sensitive to initial values. We aimed for a 3-parameter fitting algorithm that was comparably accurate, yet substantially faster. Methods Our approach gains speed by converting the 3-parameter minimisation problem into an empirically unimodal univariate problem, which is quickly minimised using the golden section line search (GS). Results To enable comparison, we propose a novel noise-masking algorithm. For clinical data, the agreement between the GS and the LM fit is excellent, yet the GS algorithm is two orders of magnitude faster. For synthetic data, the accuracy of the GS algorithm is on par with that of the LM fit, and the GS algorithm is significantly faster. The GS algorithm requires no parametrisation or initialisation by the user. Discussion The new GS T2 mapping algorithm offers a fast and much more accurate off-the-shelf replacement for the inaccurate 2-parameter fit in the vendor’s software.


  • Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise in 3D Reconstruction from Optical Projection Tomography

    by Jan Michálek

    Optical projection tomography (OPT) is a computed tomography technique at optical frequencies for samples of 0.5–15 mm in size, which fills an important “imaging gap” between confocal microscopy (for smaller samples) and large-sample methods such as fluorescence molecular tomography or micro magnetic resonance imaging. OPT operates in either fluorescence or transmission mode. Two-dimensional (2D) projections are taken over 360° with a fixed rotational increment around the vertical axis. Standard 3D reconstruction from 2D OPT uses the filtered backprojection (FBP) algorithm based on the Radon transform. FBP approximates the inverse Radon transform using a ramp filter that spreads reconstructed pixels to neighbor pixels thus producing streak and other types of artifacts, as well as noise. Artifacts increase the variation of grayscale values in the reconstructed images. We present an algorithm that improves the quality of reconstruction even for a low number of projections by simultaneously minimizing the sum of absolute brightness changes in the reconstructed volume (the total variation) and the error between measured and reconstructed data. We demonstrate the efficiency of the method on real biological data acquired on a dedicated OPT device.


  • 3D Microscopic Imaging and Evaluation of Tubular Tissue Architecture

    by J. Janáček, M. Čapek, J. Michálek, P. Karen, L. Kubínová

    3D microscopy and image analysis provide reliable measurements of length, branching, density, tortuosity and orientation of tubular structures in biological samples. We present a survey of methods for analysis of large samples by measurement of local differences in geometrical characteristics. The methods are demonstrated on the structure of the capillary bed in a rat brain.


  • Matching of irreversibly deformed images in microscopy based on piecewise monotone subgradient optimization using parallel processing

    by Jan Michálek, Martin Čapek, Jiří Janáček, Xiao W. Mao, Lucie Kubínová

    Image registration tasks are often formulated in terms of minimization of a functional consisting of a data fidelity term penalizing the mismatch between the reference and the target image, and a term enforcing smoothness of shift between neighboring pairs of pixels (a min-sum problem). For registration of neighboring physical slices of microscopy specimens with discontinuities, Janacek [1] proposed earlier an L1-distance data fidelity term and a total variation (TV) smoothness term, and used a graph-cut based iterative steepest descent algorithm for minimization. The L1-TV functional is in general non-convex, and thus a steepest descent algorithm is not guaranteed to converge to the global minimum. Schlesinger et. aI. [10] presented an equivalent transformation of max-sum problems to the problem of minimizing a dual quantity called problem power, which is - contrary to the original max-sum (min-sum) functional - convex (concave). We applied Schlesinger's approach to develop an alternative, multi-label, L1-TV minimization algorithm by maximization of the dual problem. We compared experimentally results obtained by the multi-label dual solution with a graph cut based minimization. For Schlesinger's subgradient algorithm we proposed a step control heuristics which considerably enhances both speed and accuracy compared with known stepsize strategies for subgradient methods. The registration algorithm is easily parallelizable, since the dynamic programming maximization of the functional along a horizontal (resp. vertical) gridline is independent of maximization along any other horizontal (resp. vertical) gridlines. We have implemented it both on Core Quad or Core Duo PCs and CUDA Graphic Processing Unit, thus significantly speeding up the computation.

  • Nonrigid Registration of CLSM Images of Physical Sections with Discontinuous Deformations

    by Jan Michálek, Martin Čapek, Lucie Kubínová

    When biological specimens are cut into physical sections for three-dimensional (3D) imaging by confocal laser scanning microscopy, the slices may get distorted or ruptured. For subsequent 3D reconstruction, images from different physical sections need to be spatially aligned by optimization of a function composed of a data fidelity term evaluating similarity between the reference and target images, and a regularization term enforcing transformation smoothness. A regularization term evaluating the total variation (TV), which enables the registration algorithm to account for discontinuities in slice deformation (ruptures), while enforcing smoothness on continuously deformed regions, was proposed previously. The function with TV regularization was optimized using a graph-cut (GC) based iterative solution. However, GC may generate visible registration artifacts, which impair the 3D reconstruction. We present an alternative, multilabel TV optimization algorithm, which in the examined samples prevents the artifacts produced by GC. The algorithm is slower than GC but can be sped up several times when implemented in a multiprocessor computing environment. For image pairs with uneven brightness distribution, we introduce a reformulation of the TV-based registration, in which intensity-based data terms are replaced by comparison of salient features in the reference and target images quantified by local image entropies.